| Brand | Heidolph |
|---|---|
| Origin | Germany |
| Model | Hei-PLATE Mix 'n' Heat Core+ |
| Instrument Type | Magnetic Stirrer |
| Max. Stirring Volume | 20 L (H₂O) |
| Speed Range | 100–1400 rpm |
| Speed Accuracy | ±2% |
| Temperature Range | 20–300 °C |
| Heating Power | 800 W |
| Temperature Setting Accuracy | ±1 °C |
| Temperature Control Accuracy (with external Pt1000 sensor) | ±1 °C |
| Plate Diameter | 135 / 145 mm |
| Plate Material | Kera-Disk® (silicon-aluminum alloy core + ceramic coating) |
| Protection Class | IP42 (DIN EN 60529) |
| Safety Cut-off | Activated at >25 °C above plate surface temperature |
| Residual Heat Indicator | Optical LED (activated >50 °C) |
| Interface | Analog/Digital optional |
| Timer | Optional |
| Soft Start | Yes |
| Lock Function | Yes |
| Brand | Heidolph |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Hei-PLATE Mix 'n' Heat Core+ |
| Price | Upon Request |
| Speed Range | 100–1,400 rpm |
| Speed Accuracy | ±2 % |
| Max. Stirring Volume (H₂O) | 20 L |
| Heating Plate Temperature Range | 20–300 °C |
| Heating Power | 800 W |
| Temp. Setting Accuracy | ±1 °C |
| Temp. Control Accuracy (with External Pt1000 Sensor) | ±1 °C |
| Safety Cut-off | Activated at >25 °C above Set Plate Temperature |
| Plate Diameter | 135/145 mm |
| Plate Material | Kera-Disk® (Al-Si Alloy Core + Ceramic Coating) |
| Temperature Sensor | Integrated Pt1000 |
| Sensor Breakage Protection | Yes |
| Residual Heat Indicator | Yes |
| Soft Start Function | Yes |
| Analog/Digital Interface | None |
| Timer | Not Integrated |
| Ingress Protection Rating | IP42 (per DIN EN 60529) |
| Brand | Heidolph |
|---|---|
| Origin | Germany |
| Model | 501-60410-00 |
| Stirrer Type | Electric Overhead Stirrer |
| Max. Mixing Volume | 25 L (water) |
| Speed Range | 20–2000 rpm |
| Max. Torque | 40 N·cm |
| Max. Viscosity Handling | 10,000 mPa·s |
| Timer Function | Yes |
| Operating Temperature | 5–31 °C (≤80% RH), 35–40 °C (≤50% RH) |
| Protection Class | IP42 (DIN EN 60529) |
| Motor Power | 105 W |
| Weight | 2.3 kg |
| Dimensions (W×H×D) | 70 × 281 × 195 mm |
| Max. Stirrer Shaft Diameter | 10.5 mm |
| Display | 2" monochrome digital LCD |
| Speed Control | Electronic, knob-adjusted with confirmation step |
| Overheat Protection | Automatic shutdown |
| Operation Mode | Continuous |
| Gearbox Stages | 1 |
| Brand | Heidolph |
|---|---|
| Origin | Germany |
| Model | Hei-TORQUE Core |
| Instrument Type | Electric Overhead Stirrer |
| Maximum Mixing Volume | 25 L |
| Speed Range | 20–2000 rpm |
| Torque Output | 40 N·cm |
| Power Input | 105 W |
| Viscosity Handling | up to 10,000 mPa·s |
| Shaft Diameter Compatibility | up to 10.5 mm |
| Protection Rating | IP42 |
| Display | Digital LCD with Real-Time Torque Trend Graph |
| Control | Microprocessor-Based Speed Regulation |
| Operating Modes | Continuous or Timer-Programmed |
| Safety Features | Overload Protection, Thermal Cut-Off, Audible Mounting Confirmation, Corrosion-Resistant Polymer Chuck |
| Maintenance | Brushless Motor, Sealed Housing, No Routine Lubrication Required |
| Brand | Heidolph |
|---|---|
| Origin | Germany |
| Model | Hei-VAP Core HL G3 / ML G3 |
| Capacity | 50–5000 mL |
| Ultimate Vacuum | 2 mbar |
| Rotation Speed | 10–280 rpm |
| Bath Temperature Range | 20–210 °C |
| Temperature Control Accuracy | ±1 °C |
| Condenser Cooling Surface Area | 2,200 cm² |
| Brand | Heidolph |
|---|---|
| Origin | Germany |
| Model | Hei-VAP Expert Control ML G3 |
| Capacity | 50–5000 mL |
| Ultimate Vacuum | 2 mbar |
| Rotation Speed | 10–280 rpm |
| Bath Temperature Range | 20–210 °C |
| Temperature Control Accuracy | ±1 °C |
| Condenser Surface Area | 2,200 cm² |
| Heating Power | 1300 W |
| IP Rating (Electrical Interface) | IP67 |
| Safety Features | Overtemperature cutoff (>5 °C above setpoint), dual-layer AISI 316L stainless steel bath, PTFE/FKM sealing system |
| Brand | Heidolph |
|---|---|
| Origin | Germany |
| Model | Hei-VAP Expert Control |
| Capacity | 5 L |
| Rotational Speed Range | 10–280 rpm |
| Condenser Surface Area | 1,400 cm² |
| Integrated Vacuum Controller | Yes |
| Dynamic AUTOaccurate (DAA) Distillation Mode | Yes |
| Heating Power | 1,300 W |
| Temperature Control | PT1000 sensor with ±0.5 °C accuracy |
| Display | 5″ color LCD graphical touchscreen |
| IP Rating | IP42 (electronics), IP67 (cable connectors) |
| Lift Mechanism | Manual or motorized |
| Safety Features | Dry-run protection, overheat cutoff (>5 °C above setpoint), safety film-coated glassware, integrated condensate detection, emergency stop via standby button |
| Brand | Heidolph |
|---|---|
| Origin | Germany |
| Model | Hei-VAP Industrial |
| Capacity | 6–20 L |
| Ultimate Vacuum | 1 mbar |
| Rotation Speed | 6–160 rpm |
| Bath Temperature Range | 20–180 °C |
| Temperature Control Accuracy | ±1 °C |
| Condenser Cooling Area | 1.2 m² |
| Heating Power | 4000 W |
| Display | 7-inch Touchscreen |
| Lift Mechanism | Motorized |
| Safety Features | Integrated Overtemperature Protection (cut-off at +5 °C above setpoint), Auto-refill System, Emergency Stop Button, IP42-rated Control Panel, Full PMMA & Metal Safety Enclosures |
| Programmability | 250 user-defined programs, up to 999 gradient steps per program |
| Compliance | Designed for GLP/GMP environments |
| Brand | Heidolph |
|---|---|
| Origin | Germany |
| Model | Hei-VAP Ultimate Control |
| Capacity | 5 L |
| Rotational Speed | 10–280 rpm |
| Condenser Surface Area | 1,400 cm² |
| Heating Power | 1,300 W |
| Integrated Vacuum Controller | Yes |
| Dynamic AUTOaccurate (DAA) Mode | Yes |
| Display | 7" Color LCD Graphical Touchscreen |
| IP Rating | IP42 (Electronics), IP67 (Cable Interface) |
| Safety Features | PT1000 Overtemperature Sensor, Dry-run Protection, Motorized Lift (Optional), Safety Film-Coated Glassware, Integrated Hei-CHILL Cooling Circulator Control |
| Compliance | CE, RoHS, ISO 9001 Manufacturing, GLP-Compatible Operation Log |
| Brand | Heidolph |
|---|---|
| Origin | Germany |
| Model | Hei-VAP Ultimate |
| Capacity | 5 L |
| Rotational Speed Range | 10 – 280 rpm |
| Condenser Surface Area | 1,400 cm² |
| Heating Power | 1,300 W |
| Display | 7" Color LCD Graphic Touchscreen |
| Protection Rating | IP42 (electronics), IP67 (cable interface) |
| Safety Features | PT1000 overtemperature sensor, dry-run protection, safety film-coated glassware, integrated splash guard, IQ/OQ documentation support |
| Control Interfaces | USB, microSD, LAN/RS232 (Lab 4.0 compliant) |
| Optional Upgrades | Hei-VAP Ultimate Control (vacuum + Hei-CHILL integration), AUTOaccurate vacuum probe, XL condenser (2,200 cm²), steam temperature sensor |
| Brand | Heidolph |
|---|---|
| Origin | Germany |
| Model | Multi Reax |
| Speed Range | 150–2000 rpm |
| Operating Modes | Continuous & Timer (1–999 min) |
| Vibration Type | Orbital Vortex |
| Amplitude | 3 mm |
| Display | LED Digital Speed Display |
| Housing Material | Anodized Aluminum Alloy |
| Max Load Capacity | 1.5 kg |
| IP Rating | IP30 |
| Standard Accessories | 12-position rack (for 16–32 mm tubes) & 26-position rack (for 10–16 mm tubes) |
| Input Power | 50 W |
| Sample Compatibility | Up to 26 × 10–16 mm or 12 × 16–32 mm test tubes simultaneously |
| Brand | AS ONE (Heidon) |
|---|---|
| Origin | Japan |
| Manufacturer | AS ONE Corporation |
| Model No. | 1-7124-01 |
| Instrument Type | Electric Benchtop Stirrer |
| Max. Mixing Volume | 10 L |
| Speed Range | 5–300 rpm |
| Motor Power | 40 W (BL) / 80 W (BLh) |
| Motor Insulation Class | B (130°C) |
| Torque Rating | 1.3 N·m |
| Control | Closed-loop Feedback, Forward/Reverse with Timer (5/10/20/30/45/60 s) |
| Display | 4-digit RPM, Overload Indicator, Torque Bar (20% per division) |
| Chuck | PAT Free-type Hand-Tightened Clamp for Ø8 mm Shaft |
| Safety | Current-limiting Circuit, Thermal Protector (90°C coil cutoff), Protective Housing |
| Power Supply | Single-phase 100 V, 50/60 Hz, 88 VA |
| Cord Length | 2 m |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | AutoLAB & AutoLAB Custom |
| Reactor Volume | 500 mL – 5 L |
| Material | Borosilicate Glass (Pyrex®), Stainless Steel, Corrosion-Resistant Alloys |
| Operating Pressure | Up to 200 bar (customizable) |
| Configuration | 1–8 parallel reactors |
| Modular PAT Integration | Yes |
| Software | WinISO v6.x (FDA 21 CFR Part 11 compliant, audit trail enabled) |
| Temperature Control Range | −80 °C to +250 °C (dependent on jacketed reactor & circulator) |
| Stirring | Independent digital torque-controlled overhead stirring per reactor |
| Automation Level | Fully programmable multi-parameter sequence control (T, P, agitation, dosing, sampling, pH, spectroscopy) |
| Brand | HEL |
|---|---|
| Origin | United Kingdom |
| Model | AutoLAB High Pressure |
| Reactor Volume | 500 mL – 5 L |
| Maximum Pressure | 200 bar |
| Maximum Temperature | 500 °C |
| Construction Materials | Stainless Steel (316 SS), Hastelloy, Pyrex® Borosilicate Glass |
| Reactor Configuration | Modular Parallel Reactors (1–8 stations) |
| Control Software | WinISO v7.x (FDA 21 CFR Part 11 compliant with audit trail, electronic signatures, and user access levels) |
| Stirring | Integrated overhead mechanical stirring with torque monitoring |
| Temperature Control | PID-controlled heating/cooling jackets or internal coils |
| Optional Modules | Automated liquid/gas/solid dosing, in-situ PAT (FTIR, Raman, FBRM, turbidity, pH, reaction calorimetry) |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | AutoMATE 4 |
| Reactor Type | Modular Parallel Reactor System |
| Volume Range | 10–1000 mL |
| Pressure Rating | Up to 200 bar (customizable) |
| Temperature Range | −80 °C to 250 °C |
| Control Precision | ±0.1 °C |
| Stirring Options | Magnetic, Overhead Mechanical, or Dual-mode |
| Liquid Dosing Accuracy | ±0.1% (volumetric), ±0.01 g (gravimetric) |
| Gas Dosing | Mass Flow Controlled |
| Vacuum Capability | Up to 10 MPa (absolute) |
| Construction Materials | 316 stainless steel, Hastelloy®, inert polymer seals, Pyrex® glass vessels |
| Compliance | Designed for GLP/GMP environments |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | AutoMATE High Pressure & AutoMATE Custom |
| Reactor Type | Tubular & Batch Reactor |
| Working Volume | 10–1000 mL |
| Operating Pressure | 0–10 MPa (0–100 bar, configurable up to 200 bar) |
| Temperature Range | −80 °C to 250 °C (oil bath), up to 500 °C with external circulator |
| internal heating | RT to 250 °C |
| Stirring Options | Magnetic, overhead mechanical, or dual-mode |
| Stirring Speed | 0–2000 rpm (magnetic: max torque 800 N·cm |
| overhead | max torque 80 N·cm) |
| Liquid Dosing | HPLC-grade precision pump (0.01–50 mL/min, high-pressure) |
| Gas Dosing | Mass flow controller (MFC), pressure-regulated, or volumetric metering |
| Solid Dosing | Auger feeder (350/500 mL capacity) |
| Interface Ports | Up to 5 per reactor head (customizable) for probes (pH, FTIR, turbidity, particle size), condensers, sampling, and reagent addition |
| Compliance | Designed for GLP/GMP environments |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | BioXplorer 100 |
| Reactor Type | Benchtop & Miniature Parallel Bioreactor |
| Vessel Material | Borosilicate Glass |
| Operating Pressure | Low-Pressure (Vacuum to 1 MPa) |
| Working Volume Range | 0.03–10 L |
| Control Channels | 8 Independent Bioreactors |
| Temperature Range | 25–60 °C |
| Stirring Speed (Magnetic) | 200–1200 rpm |
| Stirring Speed (Overhead) | 50–1500 rpm |
| pH & Redox Monitoring | Yes |
| Sterilizable Sensors | Yes |
| Software Modules | Entry-level Simulation, Programmable Multi-step, Full Logic Control |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | BioXplorer 400 |
| Reactor Type | Glass Tubular Bioreactor |
| Working Volume Range | 0.03–10 L |
| Operating Pressure | Low-pressure |
| Vacuum Range | 0–1 MPa |
| Temperature Control Range | −60°C to 225°C (Standard Bioprocessing: 25°C–40°C) |
| Temperature Accuracy | ±0.1°C |
| Agitation Speed (Magnetic) | 200–1200 rpm |
| Agitation Speed (Overhead Mechanical) | 50–1500 rpm |
| Number of Independent Reactors | 4 |
| Material | Borosilicate Glass |
| Sterilization Compatibility | Autoclavable Sensors & Components |
| Brand | HEL |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BioXplorer 5000 |
| Reactor Type | Jacketed Glass Vessel |
| Working Volume | 5 L |
| Operating Pressure | Low-Pressure (0–1 MPa Vacuum Range) |
| Construction Material | Borosilicate Glass (DIN/ISO Compliant) |
| Temperature Range | 25–60 °C |
| Agitation | Electromagnetic (200–1200 rpm) or Top-Drive Mechanical (50–1500 rpm) |
| pH & Redox Monitoring | Integrated In-Line Sensors |
| Sterilization Compatibility | Autoclavable Sensors & Vessels |
| Parallel Operation Capacity | Up to 4 × 5 L Vessels |
| Control Architecture | Fully Independent Channel Management |
| Software Modules | Entry-Level Simulation, Programmable Multi-Step Sequencing, Full Logic-Based Execution |
| Brand | HEL |
|---|---|
| Origin | UK |
| Model | BioXplorer 5000 High Pressure |
| Reactor Type | Jacketed Glass Vessel |
| Working Volume | 5 L |
| Operating Pressure | Up to 1 MPa (10 bar) |
| Vacuum Range | 0–1 MPa |
| Material | Borosilicate Glass 3.3 |
| Temperature Control Range | 25–60 °C |
| Agitation | Magnetic (200–1200 rpm) or Top-Drive Mechanical (50–1500 rpm) |
| Sensor Compatibility | pH, DO, Redox, Turbidity, Level, Biomass (optical), Gas Flow (MFC), Heat Flow (optional) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Software | HEL WinISO Control Suite with 21 CFR Part 11–ready audit trail, multi-step protocol editor, real-time data visualization, and remote monitoring |
| Brand | HEL |
|---|---|
| Origin | United Kingdom |
| Model | BioXplorer Modular Automated Benchtop Bioreactor Platform |
| Vessel Material | Borosilicate Glass |
| Working Pressure | Low-Pressure (0–1 MPa vacuum range) |
| Nominal Volume | 5 L |
| Configuration | Modular, Supports 1–4 Parallel Vessels |
| Temperature Range | 25–60 °C |
| Agitation | Magnetic Stirring (200–1200 rpm) or Top-Drive Mechanical Stirring (50–1500 rpm) |
| pH & Redox Monitoring | Integrated |
| Optional Features | In-situ Turbidity Detection, Reaction Calorimetry, Spectral Product Tracking, Computer-Controlled Circulating Chiller |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | CAT 7 / CAT 18 / CAT 24 |
| Max. Operating Pressure | 100 bar |
| Max. Operating Temperature | 300 °C |
| Catalyst Bed Volume | 10 mL |
| Vessel Material | 316 Stainless Steel or Hastelloy® Alloy |
| Sample Capacity Options | 2–10 mL per vessel |
| Heating Method | External (hotplate, oil bath, or PolyBlock™ heater block) |
| Stirring | Magnetic stirring integrated |
| Temperature Monitoring | Integrated micro thermocouple |
| Cooling Option | Finger-type condenser (CAT 7 & CAT 24 only) |
| HPLC Vial Compatibility | 2 mL vials (CAT 18 only) |
| Purge & Pressurization | Manual valve-controlled inert gas purge and reactant gas pressurization (e.g., H₂) |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | ChemSCAN & ChemSCAN Custom |
| Operating Pressure | 200 bar |
| Operating Temperature | −60 °C to 200 °C |
| Catalyst Bed Volume | 120 mL |
| Reactor Configuration | 8 independently controlled parallel reactors |
| Standard Vessel Capacity | 16 mL |
| Optional Vessel Capacities | 25 mL, 50 mL, 75 mL, 120 mL, 160 mL, 300 mL, 400 mL |
| Stirring Options | Magnetic suspension stirring, overhead mechanical stirring (optional), stir-controlled per reactor |
| Gas Consumption Monitoring | Real-time, reactor-specific calculation |
| Liquid Dosing | Optional automated high-pressure liquid injection |
| Compliance | Designed for GLP/GMP-aligned R&D environments |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | CrystalSCAN & CrystalSCAN Custom |
| Reactor Type | Parallel Batch Crystallization Reactor |
| Construction Material | Stainless Steel (316 SS) |
| Operating Pressure | Up to 20 bar (High-Pressure Capable) |
| Working Volume Range | 2–500 mL |
| Temperature Range | –80 °C to +250 °C |
| Number of Independent Reaction Zones | 4 or 8 |
| Stirring Method | Suspended Mechanical Impeller (configurable) / Magnetic Stirring (for small vials) |
| Max. Viscosity Handling | 1000 cP |
| Compliance | Designed for GLP/GMP-aligned process development environments |
| Software Control | Integrated PC-based control with real-time data logging and audit trail capability |
| Brand | HEL |
|---|---|
| Origin | UK |
| Model | DigiCAT 96 |
| Max. Reaction Pressure | 100 bar |
| Max. Reaction Temperature | 200 °C |
| Catalyst Loading Volume | 1 mL per vial |
| Throughput | 96 parallel reactors |
| Heating Block Material | Aluminum |
| Stirring | Synchronized magnetic stirring per vial |
| Safety Valve Setpoint | ~35 bar (standard configuration) |
| Dimensions (W×D×H) | 350 × 300 × 400 mm |
| Pressure Vessel Dimensions | 125 × 85 × 60 mm |
| Control Interface | PC-connected software with real-time monitoring and automated sequence programming |
| Actuation | Solenoid feed & vent valves |
| Temperature Control | PID-regulated, sensor-integrated aluminum heating block |
| Compliance | Designed to meet CE marking requirements for laboratory pressure equipment (PED 2014/68/EU applicable to < 200 bar systems under Category I) |
| Brand | HEL |
|---|---|
| Origin | United Kingdom |
| Model | DigiCAT |
| Reaction Pressure | 100 bar (max. 200 bar) |
| Reaction Temperature | 200 °C (max. 300 °C) |
| Catalyst Bed Volume | 75 mL |
| Compatible Reactor Formats | CAT-7, CAT-18, CAT-24, and custom vessels (16–75 mL) |
| Control Interface | PC-based software with integrated electromagnetic inlet/outlet valves, real-time T&P monitoring, safety relief valve setpoint: ~35 bar |
| Heating Method | Bottom-mounted aluminum heating block with PID temperature control |
| Stirring Mechanism | Internal magnetic stirrer drive coupled to external motor via high-strength permanent magnet array |
| Brand | HEL |
|---|---|
| Origin | United Kingdom |
| Model | FlowCAT & FlowCAT Custom |
| Operating Pressure | 200 bar |
| Operating Temperature | 550 °C |
| Catalyst Bed Volume | 30 mL |
| Reactor Materials | 316 Stainless Steel or Hastelloy |
| Standard Reactor Internal Diameter | 6 mm (¼") or 12 mm (½") |
| Active Heating Zone Length | 10 cm |
| Liquid Feed Rate Range | 0.001–10 mL/min or 0.01–50 mL/min |
| Gas Feed Control | Mass Flow Controllers (e.g., H₂) |
| Flow Modes | Trickle-Bed, Bubble-Column, Fixed-Bed Continuous Flow |
| Optional Configurations | Single or Parallel Reactor Systems |
| Compliance | Designed for GLP/GMP-aligned operation with audit-trail-capable software |
| Brand | HEL |
|---|---|
| Origin | United Kingdom |
| Model | PolyBLOCK 4 |
| Reactor Type | Modular Parallel Reaction System |
| Number of Independent Reaction Zones | 4 |
| Temperature Range | –60 °C to +230 °C (per zone) |
| Max. Temperature Differential Between Zones | 100 °C |
| Vessel Capacity | 1 mL to 500 mL (standard), up to 1000 mL (with optional adapters) |
| Construction Material | Stainless Steel (316 SS) |
| Pressure Rating | High-Pressure Compatible (up to 100 bar, dependent on vessel configuration) |
| Stirring | Hovering Mechanical Stirring (standard), with torque and speed monitoring |
| Dimensions (Platform) | 350 × 200 × 200 mm |
| Software | WinISO v8.x (Windows-based, FDA 21 CFR Part 11 compliant audit trail option) |
| Brand | HEL |
|---|---|
| Origin | United Kingdom |
| Model | PolyBLOCK 8 |
| Reactor Type | Modular Parallel Reaction System |
| Number of Independent Zones | 8 |
| Temperature Range | –60 °C to +230 °C (per zone) |
| Max. Inter-Zone ΔT | 100 °C |
| Vessel Compatibility | Standard and custom vessels (1–500 mL) |
| Vessel Diameter Limit | 48 mm |
| Vessel Depth Limit | 58 mm |
| Platform Dimensions | 350 × 200 × 200 mm |
| Stirring | Hovering mechanical stirrer (standard), configurable for heterogeneous systems and crystallization |
| Software | WinISO v7+ (Windows-based, FDA 21 CFR Part 11 compliant audit trail optional) |
| Data Export | Native .csv, .xlsx, and time-stamped binary formats |
| Optional Modules | Automated liquid dosing (multi-channel syringe pumps + multi-port valves), inline calorimetry (reaction heat flow), reflux & inert gas manifolds, pH/turbidity/pressure sensor integration |
| Brand | HEL |
|---|---|
| Origin | United Kingdom |
| Model | PolyBLOCK High Pressure |
| Reactor Type | Modular Parallel Reaction System |
| Number of Independent Reaction Zones | 4 or 8 |
| Temperature Range | –60 °C to +230 °C (per zone) |
| Max. Inter-Zone ΔT | 100 °C |
| Pressure Rating | High-Pressure Compatible (up to 100 bar, per standard configuration) |
| Vessel Capacity | 1 mL to 500 mL (standard), extendable to 1000 mL with custom vessels |
| Vessel Material | 316 Stainless Steel (standard) |
| Stirring | Magnetic and overhead mechanical stirring (hover-drive, torque-controlled) |
| Control Interface | WinISO v6.x Software (Windows-based, FDA 21 CFR Part 11 compliant audit trail option) |
| Data Output Format | CSV, Excel (.xlsx), XML |
| Compliance | CE, UKCA, ISO 9001-certified manufacturing |
| Module Compatibility | Fully modular—supports liquid dosing, inline calorimetry (RC1e-style), pH/DO/turbidity probes, reflux condensers, inert gas purging, and automated venting |
| Dimensions (4-zone base unit) | 520 × 420 × 310 mm (W × D × H) |