| Brand | Harry Gestigkeit |
|---|---|
| Origin | Germany |
| Model | SVD95/P |
| Power | 2500 W |
| Voltage | 220 V |
| External Dimensions | 450 × 310 × 180 mm |
| Maximum Temperature | 950 °C |
| Heating Time (RT → 950 °C) | < 5 min |
| Crucible Capacity | 8 × Ø34 mm or up to 4 × Ø50 mm |
| Ashing Bed Length | 400 mm |
| Timer Range | 0–120 min with audible alarm |
| Safety Interlock | Lid-activated power cutoff |
| Construction Material | Grade G stainless steel |
| Compliance | CE-marked, designed for ISO 562 / ASTM D3174 / AOAC 942.05 ash content determination |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | HAPC |
| Instrument Type | Micro-syringe Pump |
| Flow Rate Range | 0.54 pL/min – 215.8 mL/min |
| Accuracy | ±0.35% |
| Repeatability | ±0.05% |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Heat Therapy Pump |
| Connector Type | Click-Tight or Colder |
| Flow Rate | 9–14 gal/hr |
| Operating Temperature Range | 85–107 °F |
| Hose Length | 10 ft (3 m) |
| Power Supply | 120 VAC, 60 Hz or 220 VAC, 50 Hz |
| Dimensions (W × D × H) | 8.5 × 5.6 × 6.25 in (20.6 × 14.3 × 16.2 cm) |
| Weight | 5.2 lb (2.6 kg) |
| Accuracy | ±2 °F |
| Mobility | Four swivel casters + integrated carrying basket |
| Brand | Harvard Apparatus |
|---|---|
| Model | Homeothermic Blanket System |
| Origin | USA |
| Control Range | 35–40 °C (95–104 °F) |
| Preset Temperature | 37 °C |
| Probe Types | Flexible (2 mm Ø, 100 mm length) & Rigid Stainless Steel (1.6 mm Ø) |
| Blanket Sizes | Small (15 × 20 cm), Medium (45 × 70 cm), Large (60 × 90 cm) |
| Cable Length | 2 m (blanket & probe) |
| Power Delivery | Proportional DC control |
| Display | Front-panel LCD + LED power bar graph |
| Electrical Isolation | Floating design with optional grounding switch |
| Compliance | Designed for GLP-compliant in vivo physiological studies |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Nanomite Pump |
| Drive Type | Microprocessor-Controlled Syringe Pump |
| Infusion/Withdrawal | Programmable |
| Accuracy | ±0.5% |
| Repeatability | ±0.05% |
| Syringe Capacity | 0.5 µL – 10 mL |
| Flow Rate Range | 0.54 pL/min – 11.7 mL/min |
| Display | 4.3" WQVGA TFT Color Touchscreen |
| Linear Force | 5 kg (11 lbf) |
| Step Resolution | 0.198 µm/step |
| Input Voltage | 12–30 VDC |
| Dimensions (Controller) | 22.6 × 17.78 × 15 cm |
| Weight | 1.96 kg |
| Compliance | CE, ETL (UL/CSA), WEEE, EU RoHS, CB Scheme |
| Interfaces | RS-232, USB, TTL Footswitch, RS-485, IEEE-1394, 15-pin D-Sub, Mini-Phono Jack |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | New PHD ULTRA Constant Pressure Syringe Pump |
| Syringe Capacity Range | 0.5 µL to 200 mL |
| Minimum Flow Rate | 1.50 pL/min |
| Maximum Flow Rate | 216.0 mL/min |
| Maximum Linear Force | 454.5 kg |
| Interface | USB |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | P1500 |
| Flow Rate Range | 0.01–1,500 mL/min |
| Maximum Speed | 235 rpm |
| Drive Motor Compatibility | Interchangeable P-70 / P-230 / P-1500 Modules |
| Display | Full-color LCD touchscreen interface |
| Control Interfaces | USB, RS-485, 15-pin digital I/O, analog input, footswitch port |
| Operating Modes | Constant Flow, Flow Ramp, Stepped, Pulsatile, Concentration-based dosing |
| Calibration Support | User-defined tubing ID/ID-OD, automatic flow calibration per tube type |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PC2 Series (P-70 / P-230 / P-1500 Motor Drives) |
| Flow Rate Range | 0.001–1500 mL/min |
| Speed Range | 50–100 rpm (P-70), 50–100 rpm (P-230), 50–100 rpm (P-1500) |
| Accuracy | ±1.0% |
| Tubing ID Compatibility | 0.13–4.8 mm |
| Rotor Configurations | 8-channel/5-roller, 8-channel/4-roller, 4-channel/1-roller |
| Interface | RS-232 serial, USB |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Peristaltic Pump 66 and Peristaltic Pump 77 |
| Rotor Configuration | 3-roller, single-channel |
| Tubing ID Range | 1.6–3.2 mm (Model 66) / 3.2–6.4 mm (Model 77) |
| Minimum Flow Rate | 0.01 mL/min |
| Maximum Flow Rate | 210 mL/min (Model 66) / 750 mL/min (Model 77) |
| Flow Accuracy | ±1.0% |
| Communication Interface | RS-232C |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PHD 22/2000 Hpsi |
| Injection Capacity | up to 800 mL (4 × 200 mL syringes) |
| Max Force Output | 197 kg (433 lbf) |
| Accuracy | ±0.5% (stability), ±0.05% (repeatability) |
| Syringe Range | 20–200 mL stainless steel only |
| Flow Rate | 1.5 µL/hr – 112 mL/min |
| Drive Resolution | 0.0397 µm/step |
| Input Voltage | 100–240 VAC, 50/60 Hz |
| Communication | RS-232 (9-pin D-Sub), TTL, RJ11-4 |
| Control Box Dimensions | 9.5 × 27.9 × 22.9 cm |
| Syringe Mount Dimensions | 22.9 × 43.2 × 30.5 cm |
| Cable Length | 1.5 m (standard), optional 9.1 m extension |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PHD 22/2000 |
| Stability Accuracy | ±0.35% |
| Reproducibility Accuracy | ±0.05% |
| Syringe Volume Range | 0.5 µL to 140 mL |
| Flow Rate Range | 0.0001 µL/hr to 220.82 mL/min |
| Non-Volatile Memory | Yes |
| Communication Interfaces | RS-232 (RJ11-4), TTL (9-pin D-Sub) |
| Stepper Motor | 1.8°, microstepping from 1/2 to 1/32 |
| Linear Drive Resolution | 0.082 µm/step |
| Plunger Speed Range | 0.18 µm/min to 190.676 mm/min |
| Max Push Force | 66 lbf |
| Power Input | 95–130 VAC, 60 Hz or 220–260 VAC, 50 Hz |
| Dimensions (H×W×D) | 15.9 × 22.8 × 27.9 cm |
| Weight | 4.5 kg |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PHD ULTRA 4400 / HPSI / XF |
| Syringe Compatibility | Stainless steel, plastic, glass |
| Min Syringe Volume | 0.5 µL |
| Max Syringe Volume | 200 mL |
| Min Flow Rate | 3.06 pL/min |
| Max Flow Rate | 216.0 mL/min |
| Max Linear Force | 454 kg |
| Interface | USB + RS-232 |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PHD ULTRA 4400 |
| Flow Rate | 3.06 pL/min to 215.8 mL/min |
| Accuracy | ±0.25% |
| Repeatability | ±0.05% |
| Linear Force | 91 kg (200 lbf) |
| Injector Compatibility | 0.5 µL–140 mL stainless steel syringes |
| Control Interfaces | RS-232, RS-485, IEEE-1394 (FireWire), USB Type-B, TTL I/O (15-pin D-Sub) |
| Power | 100–240 VAC, 50/60 Hz, 50 W |
| Dimensions (Standalone) | 30.48 × 21.59 × 18.4 cm |
| Weight (Standalone) | 5.5 kg |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PHD ULTRA CP |
| Pump Type | Programmable Dual-Mode (Constant Pressure & Constant Flow) Peristaltic Infusion Pump |
| Pressure Control Accuracy | ±2% of setpoint |
| Pressure Units | mmHg, kPa, psi |
| Analog Input | 0–10 V DC (compatible with integrated pressure sensor/amplifier modules) |
| Communication Interface | RS-232 |
| Dual-Function | Infusion and Withdrawal |
| Warranty | 24 months |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PHD ULTRA HPSI |
| Maximum Flow Rate | 220.82 mL/min (with 140 mL syringe) |
| Max Force Output | 400 lbf |
| Syringe Compatibility | Harvard stainless steel syringes only |
| Programmable Modes | Continuous infusion, Volume-based dispensing, Auto-fill with valve manifold |
| Internal Non-Volatile Memory | Yes |
| Construction | Industrial-grade stainless steel chassis |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Certifications | CE, UL 61010-1 compliant |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤80% non-condensing |
| Dimensions (W×H×D) | 25.4 × 17.8 × 30.5 cm |
| Weight | 9.1 kg |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PHD ULTRA Infusion/Withdrawal |
| Flow Rate Range | 1.50 pL/min to 216.0 mL/min |
| Maximum Linear Force | 34 kg |
| Syringe Compatibility | Plastic, Glass, Stainless Steel |
| Interface | USB |
| Configuration Options | Standalone, Remote, Satellite, Module |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PHD ULTRA Nanomite |
| Flow Rate Range | 3.66 pL/min to 3.818 mL/min |
| Accuracy | ±0.5% |
| Repeatability | ±0.05% |
| Syringe Capacity | 0.5 µL–1 mL |
| Max Linear Force | 5 kg (11 lbs) |
| Step Resolution | 0.198 µm/µstep |
| Display | 4.3" WQVGA TFT Color Touchscreen |
| Interfaces | USB, RS-232 (optional), RS-485, TTL Digital I/O, Footswitch (9-pin D-Sub), IEEE-1394 Type B, Phono Jack |
| Compliance | CE, EU RoHS |
| Power | 100–240 VAC, 50/60 Hz, 75 W |
| Control Unit Dimensions | 30.5 × 21.6 × 11.1 cm |
| Weight | Control Unit 2.06 kg, Syringe Unit 0.458 kg |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PHD ULTRA |
| Flow Rate | 1.5 pL/min – 216 mL/min |
| Accuracy | ±0.25% |
| Repeatability | 0.05% |
| Display | 4.3" WQVGA TFT color touchscreen |
| Dimensions (L×D×H) | 12.0 × 8.5 × 7.25 in (30.48 × 21.59 × 18.42 cm) |
| Weight | 10 lb (4.5 kg) |
| Certifications | CE, UL, CSA, CB Scheme, RoHS compliant |
| Power Input | 50 W, 0.5 A fuse |
| Microstep Resolution | 12,800 microsteps per lead screw revolution |
| Minimum Plunger Speed | 0.18 µm/min |
| Maximum Plunger Speed | 190.8 mm/min |
| I/O Interface | 15-pin D-Sub TTL/RS-232/RS-485 capable |
| Non-volatile Memory | Yes |
| Syringe Capacity Range | 0.5 µL to 140 mL |
| Operating Humidity | 20–80% RH, non-condensing |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PHD ULTRA Push/Pull Infusion/Withdrawal Pump |
| Syringe Capacity | 0.5 µL – 140 mL (full stroke limited to 50 mL) |
| Minimum Flow Rate | 1.50 pL/min |
| Maximum Flow Rate | 216.0 mL/min |
| Maximum Linear Force | 34 kg |
| Interface | USB + RS-232 |
| Syringe Mounting | 4 syringes (2 per side, push/pull configuration) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PHD ULTRA XF |
| Maximum Force | 454 kg (1000 lbf) |
| Syringe Compatibility | Harvard stainless steel syringes only |
| Max Fluid Volume | 800 mL (using four 200 mL syringes) |
| Standalone Programmability | Yes, full multi-step protocol control without PC |
| Construction | Industrial-grade stainless steel frame |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PHD ULTRA™ 4400 |
| Type | Microprocessor-Driven Single-Channel Syringe Pump |
| Accuracy | ±0.35% |
| Repeatability | ±0.05% |
| Syringe Volume Range | 0.5 µL to 140 mL |
| Flow Rate Range | 3.06 pL/min to 215.8 mL/min |
| Linear Force | 91 kg (200 lbs) at 100% force selection |
| Motor | 1.8° stepper motor |
| Input Voltage | 100–240 VAC, 50/60 Hz, 50 W |
| Interface Options | RS-232 (9-pin D-Sub), RS-485, IEEE-1394 (FireWire), USB Type-B, TTL I/O (15-pin D-Sub) |
| Standalone Unit Dimensions (H×W×D) | 30.48 × 21.59 × 18.4 cm |
| Remote Unit Dimensions (H×W×D) | 27.9 × 13.5 × 18.4 cm |
| Standalone Weight | 5.5 kg |
| Remote Unit Weight | 6.4 kg |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PHD ULTRA™ 703005 |
| Accuracy | ±0.25% |
| Repeatability | ±0.05% |
| Flow Range | 1.56 pL/min to 220 mL/min |
| Max Linear Force | 75 lbf |
| Display | 4.3" WQVGA TFT color touchscreen |
| Dimensions (L×D×H) | 30.48 × 21.59 × 18.42 cm |
| Weight | 4.5 kg |
| Certifications | CE, UL, CSA, CB Scheme, RoHS |
| Connectivity | RS232, USB, RS485, 15-pin D-Sub I/O with TTL |
| Power | 50 W, 0.5 A fuse |
| Stepper Resolution | 12,800 microsteps per revolution |
| Min/Max Plunger Speed | 0.18 µm/min to 190.8 mm/min |
| Syringe Capacity | 0.5 µL to 140 mL |
| Non-volatile Memory | Yes |
| Operating Humidity | 20–80% RH (non-condensing) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | Canada |
| Model | PHD ULTRA™ Gradient System |
| Drive Type | Microprocessor-controlled syringe pump |
| Operation Modes | Infuse-only, Infuse/Withdraw, Withdraw/Infuse |
| Accuracy (Stability & Reproducibility) | ±0.25% |
| Syringe Capacity | 0.5 µL – 140 mL |
| Flow Rate Range | 1.56 pL/min – 215.8 mL/min |
| Display | 4.3" WQVGA TFT color touchscreen |
| Memory | Non-volatile storage for all program settings |
| Connectivity | RS-232, RS-485, USB, TTL I/O, footswitch (9-pin D-Sub), IEEE-1394 Type B (15-pin D-Sub), phono jack |
| Linear Force | 34 kg (75 lbs) |
| Step Resolution | 0.082 µm/step |
| Power Input | 100–240 VAC, 50/60 Hz, 8 W |
| Dimensions (H×W×L) | 10.16 × 30.48 × 21.59 cm (4 × 12 × 8.5 in) |
| Weight | 4.5 kg (10 lbs) |
| Certifications | CE, ETL (UL/CSA), WEEE, EU RoHS, CB Scheme |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PUMP 11 ELITE GC |
| Type | Peristaltic Infusion Pump for Glucose Clamp Studies |
| Compliance | Designed for preclinical metabolic research |
| Software | Onboard glucose clamp protocol engine |
| Control Interface | Capacitive touchscreen with dedicated clamp workflow UI |
| Connectivity | USB host/device, RS-232, optional Ethernet |
| Channel Configuration | Single- or dual-channel operation (with optional rotary joint integration) |
| Regulatory Context | Intended for research use only (RUO), compliant with GLP-aligned documentation practices |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Pump 11 Elite Glucose Clamp Syringe Pump |
| Accuracy | ±0.5% |
| Repeatability | ±0.05% |
| Syringe Volume Range (single) | 0.5 µL to 50/60 mL |
| Flow Rate Range (single) | 1.26 pL/min to 88.4 mL/min |
| Max Linear Force | 16 kg at 100% output |
| Display | 4.3″ WQVGA TFT color touchscreen |
| Interfaces | RS485, IEEE-1394 (FireWire), USB Type B (6-pin), 15-pin D-sub TTL I/O |
| Footswitch | Yes |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Pump 11 Elite |
| Flow Rate | 1.28 pL/min to 88.28 mL/min |
| Accuracy | ±0.5% |
| Repeatability | 0.05% |
| Syringe Volume Range | 0.5 µL to 60 mL |
| Display | 4.3" WQVGA TFT Color Touchscreen |
| Motor Step Resolution | 0.031 µm/step |
| Linear Force | 16 kg (35 lbs) |
| Input Power | 100–240 VAC, 50/60 Hz, 8 W |
| Dimensions (H×W×D) | 22.6 × 17.78 × 15 cm |
| Weight | 2.1 kg |
| Compliance | CE, ETL (UL/CSA), WEEE, EU RoHS, CB Scheme |
| Interface Options | RS-232, USB, TTL footswitch, RS-485, IEEE-1394, 15-pin D-Sub, mini phono jack |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PUMP 11 ELITE Nanomite |
| Injection/Withdrawal Accuracy | ±0.5% |
| Repeatability | ±0.05% |
| Syringe Volume Range | 0.5 µL – 1 mL |
| Flow Rate Range | 3.66 pL/min – 3.818 mL/min |
| Motor Step Resolution | 0.198 µm/step |
| Linear Force | 5 kg (11 lbs) |
| Display | 4.3" WQVGA TFT color touchscreen |
| Connectivity | RS-232, USB, TTL footswitch, RS-485, IEEE-1394, 15-pin D-Sub, mini phono jack |
| Power Input | 12–30 VDC / 100–240 VAC, 50/60 Hz, 8 W |
| Dimensions (Controller) | 22.6 × 17.78 × 15 cm |
| Weight | 1.96 kg |
| Compliance | CE, ETL (UL/CSA), WEEE, EU RoHS, CB Scheme |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Pump 11 Elite Nanomite |
| Type | Micro-syringe Pump |
| Accuracy | ±0.5% |
| Flow Rate Range | 3.66 pL/min to 3.82 mL/min |
| Maximum Linear Force | 5 kg (11 lbf) |
| Syringe Volume Range | 0.5 µL to 1 mL |
| Display | 4.3" WQVGA TFT Color Touchscreen |
| Interfaces | RS-485, USB Type B, Digital I/O (15-pin D-Sub), Footswitch Input (3.5 mm audio jack) |
| Power Input | 12–30 VDC |
| Regulatory Certifications | CE, ETL (UL/CSA), WEEE, RoHS, CB Scheme |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Pump 11 Elite Nanomite |
| Syringe Capacity | 0.5 µL – 1 mL |
| Flow Rate Range | 3.66 pL/min – 3.82 mL/min |
| Max Linear Force | 5 kg |
| Interface | USB and RS-232 serial |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Pump 11 Elite |
| Configuration | Single- or Dual-Channel, Infusion-Only or Programmable Infusion/Withdrawal |
| Accuracy | ±0.5% |
| Repeatability | ±0.05% |
| Compatible Syringe Volumes (Single Channel) | 0.5 µL to 50/60 mL |
| Compatible Syringe Volumes (Dual Channel) | 0.5 µL to 10 mL |
| Flow Rate Range (Single Channel) | 1.26 pL/min to 88.4 mL/min |
| Flow Rate Range (Dual Channel) | 1.26 pL/min to 26.02 mL/min |
| Display | 4.3-inch WQVGA TFT Color Touchscreen |
| Communication Interfaces | RS-485, IEEE-1394 (FireWire), USB 2.0, TTL/IO via 15-pin D-sub connector |
| Footswitch Support | Yes |
| Linear Force Output | 16 kg (at 100% drive power) |
| Syringe Material Compatibility | Glass and Polypropylene (Luer-lock and non-Luer syringes) |