Common Laboratory Equipment
Filter
Showing 9511–9540 of 18046 results
| Brand | LAC (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PKRC55/11 |
| Furnace Type | Box-Type Muffle Furnace |
| Max Temperature | 1100 °C |
| Temperature Uniformity | ≤ ±10 °C (per DIN 17052-1, ΔT₁₀) |
| Control Accuracy | ±1 °C |
| Heating Method | Resistive Wire (NiCr Alloy) |
| Internal Chamber Dimensions | Ø272 × 410 mm (D × H) |
| Max Power | 13 kW |
| Ramp Time to 1100 °C | ~110 min |
| Atmosphere Control | Single-Gas Inlet with Manual Venting & Auto-Controlled Gas Supply Port |
| Vacuum Capability | Up to 10⁻² mbar (with optional pump) |
| Cooling Options | Forced-air or water-cooled (G1/2 interface) |
| Safety Systems | Independent Overtemperature Cut-off, Pressure Relief Valve (4–6 mbar), Door Interlock Switch, Solid-State Relay (SSR) Isolation |
| Brand | LAC |
|---|---|
| Origin | Czech Republic |
| Model | PKRC55/95 |
| Furnace Type | Box-Type Muffle Furnace |
| Max Operating Temperature | 950 °C (1100 °C optional with Inconel chamber) |
| Temperature Uniformity | Compliant with DIN 17052-1 (ΔT ≤ 10 °C) |
| Control Accuracy | ±1 °C |
| Heating Method | Resistance Wire (NiCr) |
| Internal Chamber Dimensions | Ø272 × 410 mm (diameter × depth) |
| Max Power Consumption | 13 kW |
| Time to Max Temperature | ~110 min |
| Gas Recirculation | Integrated axial fan for forced convection |
| Atmosphere Compatibility | Inert (Ar, N₂), reducing (H₂/N₂, forming gas), reactive (Cl₂), vacuum-capable (with external pump) |
| Standard Gas Interface | Single controlled inlet (no integrated vacuum pump) |
| Safety Systems | Independent overtemperature limiter, mechanical pressure relief valve (4–6 mbar), door interlock switch, solid-state relay isolation |
| Cooling Options | Forced-air or water-cooled (G1/2 thread) |
| Controller | HT205 (30 programs × 15 steps, LAN interface) |
| Optional Controller | HT200 (30 × 25 steps, LAN + USB) |
| Compliance | CE-marked |
| Brand | LAC |
|---|---|
| Origin | Czech Republic |
| Model | PP 40/85 |
| Furnace Type | Benchtop/Industrial Box Furnace |
| Max Temperature | 850°C |
| Temperature Uniformity | ±2°C (per DIN 17052-1) |
| Heating Method | Resistive Wire (NiCr) |
| Internal Dimensions | 300 × 200 × 350 mm (W×H×D) |
| Volume | 21 L |
| Power Rating | 4 kW |
| Ramp Time to 850°C | ≤20 min |
| Insulation | Mineral Fiber (High-Density Ceramic Wool) |
| Controller | HT40AL Programmable Controller (30 programs, 15 segments each) |
| Thermocouple | K-Type |
| Safety Features | Door-Interlocked Terminal Switch, Overtemperature Cut-off |
| Construction | Low-Carbon Steel Outer Casing, AISI 304 Stainless Steel Chamber |
| Air Circulation | Horizontal Forced-Air System with Rear-Mounted Fan Assembly |
| Voltage | 230 V AC, 50/60 Hz |
| Weight | 130 kg |
| Brand | LAC |
|---|---|
| Origin | Czech Republic |
| Model | PP |
| Instrument Type | High-Temperature Box Furnace |
| Temperature Range | 25–850 °C |
| Temperature Uniformity | ±2 °C |
| External Dimensions | 800 × 650 × 1050 mm |
| Internal Chamber Dimensions | 300 × 200 × 350 mm |
| Heating Power | 3.0 kW |
| Weight | 115 kg |
| Voltage | 230 V |
| Compliance | DIN 17052-1 (Temperature Uniformity in Industrial Furnaces) |
| Controller | PID Programmable with Real-Time Clock, 30 Programs × 15 Steps |
| Thermocouple | Type K |
| Relay | Solid-State Non-Contact Semiconductor Switch |
| Muffle Material | Stainless Steel |
| Air Circulation | Horizontal Forced Convection via Rear-Mounted Fan |
| Safety Features | Door-Mounted Safety Cut-Off Switch, Mechanical Clamping Latches, Overtemperature Protection |
| Brand | LAC |
|---|---|
| Origin | Czech Republic |
| Type | Box Furnace |
| Heating Method | Electric Resistance |
| Max Temperature | 650 °C or 850 °C (model-dependent) |
| Chamber Volume | 20–70 L |
| Internal Dimensions | 300×200×350 mm to 350×400×500 mm |
| External Dimensions | 800×650×1050 mm to 950×1550×1150 mm |
| Power Input | 3.0–9.0 kW |
| Voltage | 230 V or 380 V (3-phase) |
| Weight | 115–200 kg |
| Gas Circulation | Horizontal axial fan (rear-mounted) |
| Insulation | High-density ceramic fiber |
| Heating Elements | Side-mounted FeCrAl alloy wire |
| Temperature Control | INDUSTRY PID programmable controller (30 programs × 15 segments, real-time clock, ramp/soak functionality) |
| Sensor | K-type thermocouple |
| Output Switching | Solid-state non-contact relay |
| Compliance | DIN 17052-1 (temperature uniformity class), CE-marked |
| Standard Features | Stainless steel chamber & casing, mechanical latch door with safety interlock, manual damper, adjustable shelf, base stand |
| Optional | PC interface (RS485/USB), chart recorder, inert atmosphere kit, semi-hermetic design, motorized damper, left/up-swing door, single-hand door operation, overpressure cooling system |
| Brand | LAC |
|---|---|
| Origin | Czech Republic |
| Model | PP20/45 |
| Max Temperature | 450 °C |
| Temperature Uniformity | ±1 °C |
| Max Power | 3 kW |
| Heating Time to Max Temp | 80 min |
| Heating Method | Resistance Wire |
| Internal Dimensions | 300 × 200 × 350 mm (W × H × D) |
| Controller | HT40AL (2-ramp, 2-soak) |
| Construction | Stainless Steel Chamber with Forced-Air Circulation |
| Design | Benchtop |
| Compliance | DIN 17052-1 (ΔT ≤ 10 °C) |
| Brand | LAC |
|---|---|
| Origin | Czech Republic |
| Model | PP20/65 |
| Max Temperature | 650 °C |
| Temperature Uniformity | ≤ ±1 °C (per DIN 17052-1, ΔT ≤ 10 °C) |
| Heating Method | Resistance Wire |
| Internal Chamber Dimensions | 300 × 200 × 350 mm (W × H × D) |
| Max Power | 3 kW |
| Ramp-to-Max Time | ~80 min |
| Controller | HT205 (30 programs, 15 steps each, LAN interface) |
| Cooling | Uncontrolled forced-air cooling (optional, not compatible with semi-hermetic configuration) |
| Construction | Stainless steel chamber, recirculating fan, high-resistance stainless steel baffle plates, mechanical safety interlock, manual side-hinged door |
| Compliance | Designed to meet DIN 17052-1 for industrial heat treatment and laboratory thermal processing |
| Brand | LAC |
|---|---|
| Origin | Czech Republic |
| Model | PP20/85 |
| Furnace Type | Benchtop Air-Circulating Muffle Furnace |
| Max Temperature | 850°C |
| Temperature Uniformity | ≤ ±10°C (per DIN 17052-1, ΔT at 10% volume) |
| Control Accuracy | ±1°C |
| Heating Method | Resistance Wire (NiCr Alloy) |
| Internal Chamber Dimensions | 300 × 200 × 350 mm (W × H × D) |
| Max Power Consumption | 3 kW |
| Time to Max Temp | ~80 min |
| Standard Controller | HT205 (30 programmable profiles, 15 steps/profile, LAN interface) |
| Cooling | Uncontrolled forced-air cooling (optional), controlled cooling available on non-sealed variants |
| Construction | Stainless Steel Inner Chamber, High-Resistance Ventilation Fins, Dual SS Shelving (excl. PP20), Manual Side-Hinged Door, Solid-State Relay (SSR), Door Safety Interlock |
| Compliance | Designed to meet DIN 17052-1 thermal uniformity requirements for heat treatment equipment |
| Brand | LAC |
|---|---|
| Origin | Czech Republic |
| Model | S-Series |
| Max Temperature | 200 °C / 300 °C (selectable by variant) |
| Chamber Volume | 60–380 L |
| External Dimensions (W×H×D) | 1050×1350×950 mm to 1400×1750×1200 mm |
| Internal Dimensions (W×H×D) | 450×300×450 mm to 800×800×600 mm |
| Power Input | 2–6 kW |
| Voltage | 230 V or 380 V (3-phase) |
| Weight | 60–350 kg |
| Air Circulation | Horizontal forced convection via side-mounted axial fan (S60/S100) or central radial fan (S250/S400) |
| Temperature Control | INDUSTRY PID programmable controller with 30 stored profiles (15 steps each), real-time clock, RS485/RS232 interface option |
| Safety | Door-mounted safety switch, K-type thermocouple, semiconductor non-contact SSR relay, independent current-limiting unit |
| Construction | Mild steel frame & outer casing |
| Ventilation | Manually adjustable damper with bottom exhaust |
| Compliance | Designed to meet DIN 17052-1 Class A uniformity requirements for laboratory ovens |
| Brand | LAC |
|---|---|
| Origin | Czech Republic |
| Model | S400/02 |
| Temperature Range | 60–300 °C |
| Temperature Uniformity | ±1 °C (per DIN 17052-1, Class C10–B13, ΔT ≤ 10 °C) |
| Internal Dimensions (W×H×D) | 800×800×600 mm |
| External Dimensions (W×H×D) | 1400×1750×1200 mm |
| Chamber Material | Stainless Steel (AISI 304) |
| Heating Method | Forced-Air Convection with Horizontal Airflow Distribution |
| Power Input | 6.0 kW |
| Voltage | 400 V, 3-phase |
| Weight | 3400 kg |
| Standard Controller | HT40AL (2 ramp/soak programs) |
| Optional Controllers | HT200 (30 programs × 25 steps, LAN/USB), HT205 (30 programs × 15 steps, LAN) |
| Compliance | DIN 17052-1, EN 61000-6-3, EN 61000-6-4, IEC 61000-4-2/4/5/6 |
| Brand | LAC |
|---|---|
| Origin | Czech Republic |
| Model | S400/03 |
| Temperature Range | 60–300 °C |
| Temperature Uniformity | ±1 °C (per DIN 17052-1 Class C10-B13, ΔT ≤ 10 °C) |
| Internal Dimensions (W×H×D) | 800×800×600 mm |
| External Dimensions (W×H×D) | 1400×1750×1200 mm |
| Chamber Material | Stainless Steel (AISI 304) |
| Heating Method | Forced-Air Convection with Horizontal Airflow Distribution |
| Power Input | 4.0 kW |
| Voltage | 400 V, 3-phase |
| Weight | 3400 kg |
| Standard Controller | HT40AL (2 ramp/soak segments) |
| Optional Controllers | HT200 (30 programs × 25 steps, USB + LAN), HT205 (30 programs × 15 steps, LAN only) |
| Safety | Door-limit switch, solid-state relay, overtemperature protection, thermal cut-off |
| Brand | LAC (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | SV1001/30 MKii |
| Temperature Range | 80–300 °C |
| Temperature Uniformity | ±1 °C |
| External Dimensions | 1800×2150×1200 mm (W×H×D) |
| Internal Chamber Dimensions | 1000×1200×800 mm (W×H×D) |
| Chamber Material | Stainless Steel (AISI 304) |
| Heating Method | Forced-Air Convection (50 air exchanges per minute) |
| Power Supply | 400 V, 3-phase, 50/60 Hz |
| Heating Power | 12 kW |
| Weight | 715 kg |
| Brand | LAC |
|---|---|
| Origin | Czech Republic |
| Model | VP |
| Type | Box-type Muffle Furnace |
| Max Temperature | 1600 °C / 1700 °C (depending on variant) |
| Chamber Volume | 2–70 L |
| Internal Dimensions (W×H×D) | 130×150×135 mm to 400×300×600 mm |
| External Dimensions (W×H×D) | 660×680×740 mm to 1100×1750×1150 mm |
| Power Input | 3–18 kW |
| Voltage | 230 V or 400 V |
| Heating Elements | Kanthal Super (MoSi₂) |
| Temperature Sensor | Type B Thermocouple (PtRh30/PtRh6) |
| Controller | INDUSTRY Programmable Controller (30 programs × 15 segments, real-time clock, ramp/soak profiling) |
| Safety | Door-mounted safety limit switch, forced-air cooling for electronics, rust-free stainless steel housing |
| Compliance | DIN 17052-1 (temperature uniformity), CE-marked |
| Key | Brand: LAC |
|---|---|
| Model | VP Series |
| Max Temperature | 1600–1700 °C |
| Chamber Volume | 2–70 L |
| Power Supply | 230 V or 380 V AC |
| Heating Element | Kanthal Super |
| Thermocouple Type | B- and S-type |
| Control System | INDUSTRY PID Programmable Controller (30 programs × 15 steps, real-time clock) |
| Cooling | Integrated axial fan |
| Safety | Door-mounted safety interlock switch |
| Compliance | CE-marked, designed for GLP-compliant thermal processing environments |
| Type | Muffle Furnace |
|---|---|
| Max Temperature | 1700 °C |
| Chamber Volume | 2 L |
| Internal Dimensions | 130 × 150 × 135 mm |
| External Dimensions | 660 × 680 × 765 mm |
| Power Rating | 3 kW |
| Weight | 90 kg |
| Voltage | 220 V |
| Heating Element | Kanthal A1 (Fe–Cr–Al) Wire |
| Temperature Sensor | Type B Thermocouple (Pt–Rh/Pt) |
| Controller | Industrial Programmable PID with Real-Time Clock, 30 Programs × 15 Segments |
| Optional Interfaces | RS-232/RS-485 |
| Compliance | CSN EN ISO 9001:2001 |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VP-10-17 |
| Temperature Range | 1700 °C |
| Chamber Volume | 10 L |
| External Dimensions | 850 × 1595 × 775 mm |
| Internal Dimensions | 200 × 200 × 250 mm |
| Power Rating | 6 kW |
| Weight | 290 kg |
| Voltage | 380 V AC, 3-phase |
| Heating Element | Kanthal Super ™ FeCrAl alloy wire |
| Temperature Sensor | Type B thermocouple (PtRh30–PtRh6) mounted at chamber top |
| Controller | Industrial programmable PID controller with real-time clock, 30 stored multi-step programs (≥15 segments each) |
| Optional Interfaces | RS-232 / RS-485 |
| Compliance | CSN EN ISO 9001:2001 certified |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VP-70-17 |
| Voltage | 380 V |
| Power | 14 kW |
| Max Temp | 1700 °C |
| Chamber Volume | 70 L |
| Internal Dimensions | 400 × 300 × 600 mm |
| External Dimensions | 1100 × 1650 × 1070 mm |
| Weight | 350 kg |
| Temperature Control Accuracy | ±1 °C (at steady state) |
| Heating Element | Kanthal Super (Fe–Cr–Al alloy) |
| Thermocouple Type | Type B (Pt–Rh/Pt–Rh), mounted at chamber top |
| Controller | Industrial programmable PID controller with real-time clock, 30 stored programs, up to 15 segments per program |
| Optional | RS-232/RS-485 interface, thermal cycle logging software, graphical temperature recorder, inert gas purge kit |
| Brand | LAC |
|---|---|
| Origin | Czech Republic |
| Model | VP02/16 |
| Max Temperature | 1600 °C |
| Temperature Uniformity | ±1 °C |
| Max Power | 3 kW |
| Ramp Time to 1600 °C | 135 min |
| Heating Element | Silicon Molybdenum (MoSi₂) Rods |
| Internal Chamber Dimensions | 130 × 150 × 135 mm (W × H × D) |
| Controller | HT205 (30 programs, 15 segments each, LAN interface) |
| Thermocouple Type | Type B |
| Door Operation | Manual side-opening with safety limit switch |
| Cooling | Integrated fan for electronics |
| Exhaust Port | Standard |
| Design | Benchtop |
| Brand | LAC |
|---|---|
| Origin | Czech Republic |
| Model | VP02/17 |
| Max Temperature | 1700 °C |
| Temperature Uniformity | ±1 °C |
| Max Power | 3 kW |
| Ramp Time to 1700 °C | 135 min |
| Heating Element | Silicon Molybdenum (MoSi₂) Rods |
| Internal Chamber Dimensions | 130 × 150 × 135 mm (W × H × D) |
| Controller | HT205 (30 programs, 15 segments each, LAN interface) |
| Thermocouple Type | Type B |
| Door Operation | Manual side-opening with safety limit switch |
| Cooling | Integrated fan for electronic components |
| Exhaust Port | Standard |
| Configuration | Benchtop design |
| Brand | LAC |
|---|---|
| Origin | Czech Republic |
| Model | VP02/18 |
| Max Temperature | 1800 °C |
| Temperature Uniformity | ±1 °C |
| Max Power | 3 kW |
| Ramp Time to 1800 °C | 135 min |
| Heating Element | Silicon Molybdenum (MoSi₂) Rods |
| Internal Chamber Dimensions | 130 × 150 × 135 mm (W × H × D) |
| Controller | HT205 (30 programs, 15 segments each, LAN interface) |
| Thermocouple Type | Type B |
| Door Operation | Manual side-opening with safety limit switch |
| Cooling | Integrated fan for electronics |
| Exhaust Port | Standard |
| Design | Benchtop |
| Brand | LAC |
|---|---|
| Origin | Czech Republic |
| Model | VP1000/17 |
| Max Temperature | 1700 °C |
| Operating Temperature Range | 1400–1700 °C |
| Temperature Uniformity | ±10 °C |
| Internal Dimensions (W×H×D) | 1100 × 1000 × 1100 mm |
| Effective Working Zone (W×H×D) | 800 × 800 × 800 mm |
| Chamber Volume | 1200 L |
| Control Accuracy | ±1 °C |
| Max Power | 140 kW |
| Heating Rate to 1700 °C | 180 min |
| Heating Elements | 24 × Kanthal® MoSi₂ Rods (Vertical, Four-Sided Configuration) |
| Lift Mechanism | Motor-Driven with Gearbox & VFD Control |
| Insulation | 300 mm Compressed Ceramic Fiber Modules + Refractory Brick Base Layer |
| Electrical Supply | 3/PEN 400/230 V AC, 50 Hz |
| Weight | 3500 kg |
| Load Capacity | 200 kg |
| Cooling | Forced-Air Dual-Shell Ventilation System |
| Controller | Siemens S7-1200 PLC + TP700 Color HMI |
| Temperature Sensing | Type B Thermocouples (PtRh30/PtRh6) |
| Data Logging | 7-Day Internal Storage + USB Export |
| Compliance | CE, EN 61000-6-4 (EMC), EN 61000-6-2 (Immunity), EN 60204-1 (Safety) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CCS-100 |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4 K to 325 K |
| Temperature Stability | ±50 mK |
| Sample Environment | High Vacuum |
| Typical Cool-Down Time | 1–2 h |
| Vibration Level | Not Specified |
| Optical Window | Yes |
| Window Diameter | 83–85 mm |
| Cold Head Mounting | Flexible (User-Defined Orientation) |
| Recommended Compressor Maintenance Interval | 13,000 h |
| Approximate Height | 56–84 cm |
| Approximate Weight | 16–29 kg |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CCS-300S |
| Cooling Type | Closed-cycle cryocooler |
| Temperature Range | <4 K to 325 K |
| Sample Environment | High Vacuum |
| Typical Temperature Stability | ±50 mK |
| Cool-down Time | 1.5–2.5 h |
| Vibration Level | <40 nm (RMS) |
| Optical Window | Yes |
| Window Diameter | 38 mm to 85 mm |
| Cold Head Mounting | Flexible (user-configurable orientation) |
| Recommended Cryocooler Maintenance Interval | 13,000 hours |
| Approximate Height | 71–99 cm |
| Approximate Weight | 17–30 kg |
| Compliance | Designed for integration into ISO/IEC 17025-compliant labs and GLP/GMP-adjacent research environments |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CCS-300ST |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4 K to 325 K |
| Sample Environment | High Vacuum |
| Typical Temperature Stability | ±50 mK |
| Cooling Time | 1.5–2.5 h |
| Design | Compact, Magnet-Compatible |
| Optical Window | None |
| Cold Head Mounting | Flexible (Arbitrary Orientation) |
| Approximate Weight | 17–30 kg |
| Recommended Cryocooler Maintenance Interval | 13,000 h |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CCS-400 |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4 K to 500 K |
| Sample Environment | High Vacuum |
| Typical Temperature Stability | ±50 mK |
| Cool-down Time | 1.5–3 h |
| Optical Window | Yes (83–85 mm diameter) |
| Vibration Level | <40 nm (RMS) |
| Recommended Cryocooler Maintenance Interval | 13,000 h |
| Dimensions (H) | 61–89 cm |
| Weight | 16–30 kg |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CCS-400H |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | 5 K to 800 K |
| Sample Environment | High-Vacuum Chamber |
| Typical Temperature Stability | ±50 mK |
| Cooling Time (to base temperature) | 2–2.5 h |
| Optical Window Diameter | 83–85 mm |
| Recommended Cryocooler Maintenance Interval | 13,000 h |
| Vibration Level | <40 nm (RMS, at sample stage) |
| Cold Head Mounting | Flexible (top-mount configuration standard) |
| Weight | 16–30 kg |
| Height | 66–94 cm |
| Compliance | Designed for ASTM E220, ISO/IEC 17025-compliant lab environments |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | CCS-800 |
| Price | Upon Request |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4.5 K to 300 K |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | Exchange Gas (He) |
| Optical Window | Optional |
| Sample Loading | Top-Access |
| Sample Chamber Inner Diameter | 38 mm |
| Rotatable Sample Stage | Yes |
| Cool-Down Time | 2–2.5 h |
| Cryocooler Mounting | Bottom-Mounted |
| Vibration-Induced Linewidth Broadening | ≤0.01 mm/s (Δv/v) |
| Approximate Height | 142–168 cm |
| Weight | 27.2 kg (cryostat only) |
| Window Block Outer Diameter | 57.2 mm |
| Recommended Cryocooler Maintenance Interval | 13,000 h |
| Sample Exchange Time | ~5 min |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CCS-900 |
| Quotation | Upon Request |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4 K to 800 K (2 K optional) |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | Exchange Gas |
| Sample Types | Solid, Liquid, Powder |
| Sample Exchange Time | <10 min |
| Rotatable Sample Stage | Yes |
| Cool-down Time | 3–4 h |
| Cold Head Position | Top-Mounted |
| Optical Window | Standard (CCS-900), Optional (CCS-900-T) |
| Approximate Height | 114 cm (CCS-900), 114–168 cm (CCS-900-T) |
| Approximate Weight | 48 kg (CCS-900), 45–50 kg (CCS-900-T) |
| Sample Chamber Diameter | 38.1 mm |
| Customizable Chamber Dimensions | 28.6 mm, 38.1 mm, 60.3 mm |
| Window Block Diameter | 95.3 mm |
| Recommended Cryocooler Maintenance Interval | 13,000 h |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | CCS-TRAP / CCS-TRAP-H |
| Pricing | Upon Request |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <8 K to 325 K / <9 K to 500 K |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | High Vacuum |
| Cool-down Time | 1–1.5 h |
| Cold Head Position | Bottom-Mounted |
| Approx. Height | 91.4 cm / 96.5 cm |
| Approx. Weight | 19.1 kg |
| Recommended Refrigerator Maintenance Interval | 13,000 h |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CCS-XG |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4 K to 325 K |
| Sample Environment | High Vacuum |
| Vibration Level | <40 nm (RMS) |
| Typical Temperature Stability | ±50 mK |
| Cool-Down Time | 2–3 h |
| Optical Window Diameter | 83–85 mm |
| Approximate Height | 66–94 cm |
| Approximate Weight | 17–30 kg |
| Recommended Cold Head Maintenance Interval | 13,000 h |