Energy Dispersive X-Ray Fluorescence Spectrometer
Filter
Showing 91–120 of 318 results
| Brand | Bruker |
|---|---|
| Origin | Italy |
| Model | S1 TITAN |
| Application | Handheld/Portable |
| Element Range | Mg–U |
| Detection Limit | 1 ppm – 99.99% |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability | ±0.1% RSD |
| Detector | Silicon Drift Detector (SDD) |
| Weight | 1.5 kg |
| Compliance | API RP 578, ASTM E2857, ISO 21043, GLP/GMP-ready data audit trail |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S1 TITA |
| Application | Handheld/Portable |
| Element Range | Na (11) – U (92) |
| Detection Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Detector | Silicon Drift Detector (SDD) |
| Weight | 1.5 kg |
| Compliance | API RP 578, ASTM E2857, ISO 17025 (when operated under accredited conditions), FDA 21 CFR Part 11–ready software configuration |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S1 TITAN |
| Application | Handheld/Portable |
| Industry-Specific Use | Soil and Atmospheric Environmental Monitoring |
| Elemental Range | Mg to U |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV (Mn Kα) |
| Detector | Silicon Drift Detector (SDD) |
| Compliance | ASTM D7213, ISO 18562-2, EPA Method 6200 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S1 TITAN600 |
| Application | Handheld/Portable |
| Element Range | Na–U |
| Detection Limit | 1 ppm |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Detector | Silicon Drift Detector (SDD) |
| Regulatory Compliance | RoHS II (2011/65/EU), CPSIA 2008, EPA Method 6200, California Proposition 65, US Safe Drinking Water Act |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S1TITAN Soil |
| Application | Handheld/Portable |
| Industry-Specific Use | Soil and Atmospheric Environmental Monitoring |
| Elemental Analysis Range | Mg to U |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability | XRF-based statistical repeatability per ASTM E2783 |
| Detector | Silicon Drift Detector (SDD) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Configuration | Benchtop TXRF System |
| Element Range | Al (13) to U (92) |
| Detection Limit | down to 2 pg |
| Quantification Range | sub-ppb to 100% w/w |
| Energy Resolution | <125 eV at Mn Kα (FWHM, 100 kcps) |
| Repeatability | ≤0.1% RSD |
| Detector | Fourth-generation XFlash® Silicon Drift Detector (SDD) with Peltier cooling |
| Sample Volume | 1–50 µL (liquids/suspensions) |
| Automation Options | 1-position or 25-position autosamplers |
| Compliance | Fully compatible with ISO 17025, ASTM E2486, and EU Directive 2009/48/EC for elemental migration testing |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S2 PICOFOX |
| Detector | 4th-generation XFlash® silicon drift detector (SDD) with Peltier cooling |
| Energy resolution | 160 eV at Mn Kα (100 kcps) |
| Elemental range | Al (13) to U (92) |
| Sample volume | 1–50 µL (liquid/suspension), ≤10 µg (powder) |
| Automation options | 1-position or 25-position autosampler |
| Compliance | Fully compliant with ISO 8258 (control charts), ISO/IEC 17025 (testing laboratories), and supports GLP/GMP data integrity requirements per FDA 21 CFR Part 11 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S2 PICOFOX |
| Configuration | Benchtop |
| Application Type | General Purpose |
| Elemental Range | Al (13) to U (92) |
| Detection Limit | down to 2 pg |
| Quantification Range | sub-ppb to 100% |
| Energy Resolution | <125 eV at Mn Kα (low count rate), <135 eV at Mn Kα (high count rate, 100 kcps) |
| Repeatability | ≤0.1% RSD |
| Detector | Fourth-generation XFlash® Silicon Drift Detector (SDD) with Peltier cooling |
| Sample Volume | 1–50 µL (liquids/suspensions), ≤10 µg (powders) |
| Automation Options | 1-position or 25-position auto-samplers |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | S2 PICOFOX (TXRF) |
| Configuration | Benchtop |
| Application Scope | General-Purpose |
| Elemental Range | Al (13) to U (92) |
| Detection Limit | Down to 2 pg |
| Quantification Range | ppb to 100% |
| Energy Resolution | <125 eV at Mn Kα (FWHM, 100 kcps), <135 eV typical |
| Repeatability | ≤0.1% RSD |
| Detector | Fourth-Generation XFlash® Silicon Drift Detector (SDD) with Peltier Cooling |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Configuration | Benchtop/ Floor-standing |
| Model | S2 POLAR |
| Compliance | ASTM D7220, ASTM D4294, ASTM D6481, ASTM D7751, ASTM D8252, ISO 13032, ISO 20847, ISO 8754, IP 336, IP 496, IP 532, JIS K2541-4 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Configuration | Benchtop/Polarized EDXRF |
| Element Range | Na (11) to Am (95), optional C (6) to Am (95) |
| Concentration Range | ppm to 100% |
| Energy Resolution | <135 eV (Mn Kα) |
| Repeatability | <0.1% RSD |
| Detector | HighSense™ Ultra-Low-Noise Silicon Drift Detector (SDD) |
| Compliance | ASTM D6481, ASTM D7751, ASTM D7220, ISO 13032, ASTM D4294, ISO 20847, ISO 8754, IP 336/496/532, JIS K2541-4, GB/T 11140 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S2 PUMA Series 2 |
| Configuration Options | Benchtop / Floor-standing |
| Elemental Range | C (Z=6) to Am (Z=95) |
| X-ray Tube Power | 50 W |
| Detector | HighSense™ Silicon Drift Detector (SDD) |
| Sample Chamber Dimensions | 450 × 420 × 100 mm |
| Autochanger Capacity | Up to 20 positions (XY Autochanger) or 12–18 samples (Carousel) |
| Mapping Resolution | Down to 1 mm |
| Spot Size | 1–34 mm (with collimator masks) |
| Software | SPECTRA.ELEMENTS with SMART.QUANT FP |
| Compliance | Designed for GLP/GMP environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S2 PUMA Series II |
| Element Range | Na (11) to Am (95) [C (6) to Am (95)] |
| Detection Range | ppm to 100% |
| Energy Resolution | <135 eV |
| Repeatability | <0.1% RSD |
| Detector | HighSense™ Silicon Drift Detector (SDD) |
| Configuration Options | Manual Single-Position, XY Autochanger, Carousel Autosampler |
| Sample Chamber Dimensions | 450 × 420 × 100 mm |
| X-ray Tube | 50 W Rh anode |
| Filter Changer | 10-position automatic |
| Software Suite | SPECTRA.ELEMENTS with Smart-Quant FP, Geo-Quant, Cement-Quant, and regulatory-compliant modules |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S4 TSTAR |
| Technique | Total Reflection X-Ray Fluorescence (TXRF) |
| Detection Limit | Sub-ppb for liquid, solid, and thin-film samples |
| Sample Forms | Liquids, suspensions, dried residues, wafers, microscope slides, quartz carriers, membranes, filters, and nanoparticle layers |
| Compliance Context | Supports ISO 17025-compliant workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S4 TStar |
| Configuration | Benchtop |
| Application Type | General Purpose |
| Elemental Range | Al (13) to U (92) |
| Detection Range | 0.1 pg to 100 wt% |
| Energy Resolution | <125 eV at Mn Kα (FWHM), <135 eV at Cu Kα |
| Repeatability | ≤0.1% RSD (for major elements, ≥100 s counting) |
| Detector | Silicon Drift Detector (SDD) |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | TRACER 5 |
| Application | Handheld / Portable |
| Industry Use | General-Purpose |
| Elemental Range | F to U |
| Quantification Range | ppm to wt% |
| Energy Resolution | 145 eV |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | TRACER 5g |
| Application | Handheld/Portable |
| Instrument Type | General-Purpose Research-Grade ED-XRF |
| Industry-Specific Use | Geoscience & Mineral Exploration |
| Elemental Range | Na (Z=11) to U (Z=92) |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% RSD |
| Detector | Silicon Drift Detector (SDD) with 1 µm Graphene Window |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tracer 5i |
| Application | Handheld/Portable |
| Industry Type | General-Purpose |
| Elemental Range | Na (11) – U (92), down to F (9) under vacuum/He flush |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV (at Mn Kα) |
| Repeatability | 0.1% RSD |
| Detector | Silicon Drift Detector (SDD) |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XMS |
| Form Factor | Benchtop / Floor-Standing |
| Application Type | General-Purpose |
| Elemental Range | Mg (Z=12) to U (Z=92) |
| Quantitative Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV (at Mn Kα, −20 °C) |
| Repeatability | ≤0.1% RSD (for major elements under controlled conditions) |
| Detector | Silicon Drift Detector (SDD) |
| Brand | COX Analytical Systems |
|---|---|
| Origin | Sweden |
| Model | Itrax XRF |
| Configuration | Benchtop/Floor-standing |
| Application Domain | Geological & Sediment Core Analysis |
| Elemental Range | Na (11) – U (92) |
| Detection Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability | ≤0.1% RSD |
| Brand | Dongxi Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | XD-8010 |
| Form Factor | Benchtop/Floor-standing |
| Industry Application | Geological & Mineralogical Analysis |
| Elemental Range | S (Z=16) to U (Z=92) |
| Quantification Range | ppm to wt% |
| Filter Options | 15-position automatic filter wheel |
| Beam Diameter | 1–7 mm adjustable |
| Sample Chamber | Large-volume, non-destructive chamber |
| Software | Integrated EDXRF workstation with real-time video imaging, report customization (PDF/Excel), spectral comparison, and GLP-compliant data archiving |
| [Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | EDX 2800B |
| Form Factor | Benchtop / Floor-Standing |
| Industry-Specific Use | Electronics Manufacturing & QC |
| Elemental Range | S (16) to U (92) |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | 149 ± 5 eV (at Mn Kα) |
| Repeatability (RSD) | ≤ 0.1% for major elements |
| Measurement Time | 100–300 s per sample |
| Operating Temperature | 15–30 °C |
| Relative Humidity | 40–50% RH |
| Power Supply | AC 220 V ± 5 V, 50/60 Hz |
| Detector | Si-PIN semiconductor, Peltier-cooled |
| X-ray Tube | 50 kV max, 1 mA max, air-cooled, 50 W nominal |
| Multichannel Analyzer | 2048-channel MCA with digital pulse processing |
| Collimator Options | 8 automatic sizes (0.2–8 mm Ø) |
| Filter Options | 6 programmable primary beam filters |
| Calibration | Auto-curve selection, matrix-matched standards included |
| Software | XRAYAnalyzer v3.x, compliant with GLP data integrity requirements] |
| Brand | ESI |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | EDX9000B PLUS |
| Configuration | Benchtop/Floor-standing |
| Industry-Specific Application | Non-Ferrous Metals |
| Elemental Range | Na (Z=11) to U (Z=92) |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability (RSD) | ≤0.05% |
| Detector | Peltier-Cooled Fast Silicon Drift Detector (FSDD) |
| Brand | Evident (formerly Olympus) / EVDENT |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | DELTA DPO-2000 |
| Application | Handheld / Portable |
| Industry-Specific Use | Non-Ferrous & Specialty Alloys |
| Elemental Range | Mg to U |
| Quantification Range | ppm to wt% |
| Energy Resolution | <140 eV at Mn Kα |
| Repeatability | ≤0.1% RSD |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XAN-DPP |
| Configuration | Benchtop/Free-standing |
| Excitation Source | Rhodium anode X-ray tube |
| Detector | Peltier-cooled Si-PIN diode (≈ −30 °C) |
| Energy Resolution | 180 eV (Mn Kα) |
| Elemental Range | Al (Z=13) to U (Z=92) |
| Collimators | Motorized, programmable: Ø0.2 mm, Ø0.6 mm, Ø1.0 mm, Ø2.0 mm |
| Measurement Chamber Internal Dimensions (incl. sloped door) | W 318 mm × D 307 mm × H 29–86 mm |
| Usable Height Zone (full-height region) | W 318 mm × D 203 mm × H 86 mm |
| Distance Compensation | Patented DCM (Distance Controlled Measurement) algorithm |
| Calibration | Standardless quantitative analysis enabled via fundamental parameters method |
| Simultaneous Output | Elemental concentration (ppm–wt%) and substrate thickness (µm) |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XDV-SDD |
| Form Factor | Benchtop |
| Elemental Range | Al (Z=13) to U (Z=92) |
| Detection Limit | 1 ppm |
| Quantification Range | 1 ppm – 100 wt% |
| Energy Resolution | ≤140 eV (Mn Kα) |
| Repeatability | ≤5% RSD |
| Sample Stage | Motorized XYZ with Programmable XY Translation and Z-Axis Lift |
| X-ray Source | Microfocus Tungsten Anode Tube with Beryllium Window |
| High Voltage | 3-step Adjustable (up to 50 kV) |
| Filter Options | 6 Interchangeable Primary Filters |
| Collimators | Motorized, Switchable Apertures |
| Optical Alignment | Integrated HD Video System with 20× Digital Zoom, Crosshair Overlay, and Laser Spot Locator |
| Software Platform | WinFTM® v8.x (FDA 21 CFR Part 11 Compliant, Audit Trail Enabled, GLP/GMP-Ready) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Model | MiX5 500 |
| Form Factor | Handheld / Portable |
| Target Materials | Ferrous Alloys |
| Pre-installed Alloy Libraries | AISI, DIN, JIS, GB (1600+ grades) |
| Detector | Silicon Drift Detector (SDD) |
| X-ray Tube | High-Performance Microfocus Tube |
| Display | 4.3-inch Color Touchscreen |
| Weight | 1.5 kg |
| Battery Life | 10–12 hours |
| IP Rating | IP54 |
| Data Storage | Up to 100,000 results with spectra and optional images |
| Output Formats | CSV, PDF |
| Connectivity | USB, Wi-Fi, Bluetooth |
| Compliance Support | GLP/GMP audit trail capability, FDA 21 CFR Part 11–ready software architecture |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MiX5 Pro |
| Form Factor | Handheld / Portable |
| Application Scope | General-Purpose Metal & Alloy Analysis |
| Elemental Range | Mg (12) to U (92) |
| Detection Limits | Sub-ppm to % level (matrix-dependent) |
| Detector | High-Performance Silicon Drift Detector (SDD) |
| Energy Resolution | ≤145 eV at Mn Kα |
| Repeatability | RSD < 1% for major elements (typical alloy matrix, ≥10 s measurement) |
| Operating Temperature | –10 °C to 50 °C |
| IP Rating | IP54 |
| Battery Life | Up to 12 hours (standard Li-ion pack) |
| Display | 5.5-inch capacitive touchscreen with sunlight-readable brightness |
| Connectivity | Wi-Fi 802.11 a/b/g/n, USB-C, optional integrated 5 MP macro camera |
| Software Compliance | Supports audit trail, user access control, and data export compliant with GLP/GMP documentation requirements |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | HORIZON |
| Configuration | Benchtop/Floor-standing |
| Application Type | General-purpose |
| Elemental Range | Na (11) to Pu (94) |
| Quantification Range | 10 pg – 100% |
| Energy Resolution | 124 eV (at Mn Kα) |
| Repeatability | ≤ 0.1% RSD |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | TX 2000 |
| Configuration | Benchtop/Floor-standing |
| Application Type | General-purpose |
| Elemental Range | Na (11) to Pu (94) |
| Quantification Range | 10 pg – 100% |
| Energy Resolution | 124 eV (at Mn Kα) |
| Repeatability | 0.1% RSD |
| Detector | Peltier-cooled Silicon Drift Detector (SDD) |
| Excitation Source | Switchable Mo/W anode X-ray tube |
| Angular Control | High-precision optical encoder stepper motor |
