Energy Dispersive X-Ray Fluorescence Spectrometer
Filter
Showing 181–210 of 318 results
| Brand | Malvern Panalytical |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Epsilon1 |
| Form Factor | Benchtop |
| Industry Application | Energy & Chemicals |
| Elemental Range | Na (Z=11) to Am (Z=95) |
| Quantification Range | 1 ppm to 100% w/w |
| Energy Resolution | <145 eV at Mn Kα (5.9 keV, 1000 cps) |
| Repeatability | Concentration-dependent, compliant with ISO 8258 and ASTM E1621 for precision validation |
| Brand | Malvern PANalytical |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Revontium |
| Form Factor | Benchtop/Floor-standing |
| Instrument Type | Conventional ED-XRF |
| Application Scope | General-purpose |
| Elemental Range | Na to Am (Z = 11 to Z = 95) |
| Energy Resolution | <145 eV at Mn Kα |
| Detectors | Four simultaneous silicon drift detectors (SDDs) |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Type | Domestic |
| Model | PORT-X710 Handheld ED-XRF Spectrometer |
| Application | Field-Portable |
| Instrument Class | General-Purpose |
| Industry-Specific Use | Multi-Material Alloy Analysis |
| X-ray Tube | 5 W / 50 kV / 200 µA max |
| Target Material | Rhodium (Rh) |
| Detector | Si-Pin |
| Energy Resolution | ≤185 eV |
| Operating Temperature | –10 °C to 50 °C |
| Dimensions | 240 mm (L) × 110 mm (W) × 240 mm (H) |
| Weight | 1.6 kg |
| Quantitative Method | Fundamental Parameters (FP) |
| Elemental Range | Ti to U |
| Battery | Dual Li-ion, 7.4 V / 9600 mAh |
| Runtime | ≥10 h (typical) |
| Processor | Qualcomm Snapdragon™ octa-core, 2.0 GHz, 14 nm FinFET, 1 MB L2 cache |
| OS | Android 7.1 |
| Display | 5.5-inch Full HD (1080p) capacitive touchscreen |
| Connectivity | Wi-Fi 802.11 a/b/g/n/ac, Bluetooth 4.2/LE |
| Radiation Safety | Integrated shutter, sample proximity sensor, password-protected startup, certified radiation shielding per CNAS and GBZ 188–2014 |
| Sample Compatibility | Solid metal alloys (e.g., stainless steels, low-alloy steels, Cu-based, Ni-based, Ti alloys), scrap fragments, billets, pipes, fasteners |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Type | Handheld/Portable |
| Model | PORT-X720 |
| X-ray Tube | 5 W, 50 kV, 200 µA max |
| Anode Material | Rhodium (Rh) |
| Detector | Silicon Drift Detector (SDD) |
| Energy Resolution | ≤155 eV |
| Operating Temperature | −10 °C to 50 °C |
| Dimensions | 240 × 110 × 240 mm |
| Weight | 1.6 kg |
| Measurement Elements | Mg to U |
| Battery | Dual 7.4 V / 9600 mAh Li-ion |
| Runtime | ≥10 h |
| Processor | Qualcomm Snapdragon™ Octa-core (14 nm FinFET), 2.0 GHz, 1 MB L2 cache |
| OS | Android 7.1 |
| Display | 5.5-inch Full HD (1080p) touchscreen |
| Connectivity | Wi-Fi 802.11 a/b/g/n/ac, Bluetooth 4.2/LE, USB |
| Radiation Safety | Integrated shutter, sample proximity sensor, password-protected startup, regulatory compliance per CNAS and GBZ 188–2014 |
| Analysis Algorithm | Fundamental Parameters (FP) method with user-customizable method development capability |
| Brand | Niton |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Model | XL5 |
| Application | Field-Portable |
| Industry-Specific Use | Geological & Mining Exploration |
| Elemental Range | Mg to U |
| Quantification Range | 1 ppm – 99.99% |
| Repeatability | ±0.1% RSD |
| Detector | Graphene-Enhanced Silicon Drift Detector (SDD) |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DCC-4000 |
| Portability | Handheld |
| Application Domain | Soil & Atmospheric Environmental Monitoring |
| Elemental Range | K (19) to U (92) |
| Detection Limit | 1 ppm |
| Quantification Range | 1 ppm – 100% |
| Energy Resolution | <140 eV (at Mn Kα) |
| Repeatability | ±0.1% RSD |
| Dimensions | 245 × 250 × 88 mm |
| Weight | <1.5 kg |
| Operating Temperature | −10 °C to +50 °C |
| Relative Humidity | 0–95% non-condensing |
| Excitation Source | High-power micro-focus X-ray tube (15–40 kV) |
| Detector | Si-PIN semiconductor detector with Peltier cooling to −35 °C |
| Filter System | 8-position automatic filter changer |
| Data Storage | MicroSD card (≥100,000 spectra) |
| Connectivity | USB 2.0, Bluetooth v2.1 + EDR |
| Operating System | Windows CE 6.0 |
| Battery | Dual hot-swappable Li-ion packs |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DCC2000 |
| Application | Handheld/Portable |
| Elemental Range | Mg (12) to U (92) |
| Concentration Range | 1 ppm – 100% |
| Energy Resolution | <150 eV |
| Repeatability | 0.1% |
| Dimensions | 245 × 250 × 88 mm |
| Weight | <1.5 kg |
| Operating Temperature | −10 °C to +50 °C |
| Humidity | 0–95% RH (non-condensing) |
| Excitation Source | High-power micro-focus X-ray tube (8–40 kV) |
| Detector | Si-PIN semiconductor detector with Peltier cooling (down to −35 °C) |
| Filter System | 8-position automatic filter changer |
| Power Supply | Dual hot-swappable Li-ion batteries |
| Display | High-resolution transflective color touchscreen |
| Data Storage | SD card (≥100,000 spectra) |
| Connectivity | USB 2.0, Bluetooth 2.1 (Microsoft-compatible stack) |
| OS | Windows CE 6.0 |
| Software | Delta PC Suite for remote control, report generation, and spectral library management |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DCC6500 |
| Application | Handheld / Field-Portable |
| Industry-Specific Use | Electronics Manufacturing & Compliance Testing |
| Elemental Range | Mg (12) to U (92) |
| Quantification Range | ppm to 100% |
| Energy Resolution | <150 eV |
| Repeatability | ±0.1% |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DELTA DE2000 |
| Application | Handheld / Portable |
| Industry Focus | Non-Ferrous Metals & Precious Metals |
| Elemental Detection Range | Mg to U |
| Quantification Range | 1 ppm – 100 wt% |
| Energy Resolution | <139 eV (at Mn Kα) |
| Repeatability | ≤0.1% RSD |
| Detector Type | Si-Pin Semiconductor Detector |
| Excitation Source | Ta/Au Target X-ray Tube, 4 W Max Power |
| Operating Voltage | Up to 35 kV |
| Cooling System | Peltier Thermoelectric Cooler (Operable down to −35 °C) |
| Battery | Dual Hot-Swappable Li-ion Batteries |
| Display | High-Resolution Blanview Transflective Color Touchscreen |
| Data Storage | Removable SD Card |
| Compliance | ISO 9001 Certified, NATO AQAPI Qualified |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DE2000 |
| Application | Handheld / Portable |
| Industry-Specific Use | Non-Ferrous & Ferrous Metals |
| Elemental Range | Mg to U |
| Quantification Range | 1 ppm – 99.9 wt% |
| Energy Resolution | <140 eV (at Mn Kα) |
| Repeatability | ≤0.1% RSD (for major alloying elements under controlled conditions) |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DP2000 |
| Application | Handheld/Portable |
| Industry Type | Non-Ferrous Metals |
| Elemental Range | Na (11) – U (92) |
| Concentration Range | 1 ppm – 100% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DPO2000 |
| Application | Handheld/Portable |
| Industry Type | Non-Ferrous Metals |
| Elemental Range | Mg (12) – U (92) |
| Detection Range | 1 ppm – 100% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DPO4000 |
| Element Range | Na (11) to U (92) |
| Detection Range | 1 ppm – 100% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Dimensions | 245 × 250 × 88 mm |
| Weight | <1.5 kg |
| Operating Temperature | −10 °C to 50 °C |
| Relative Humidity | 0–95% RH |
| Excitation Source | High-power micro-focus X-ray tube (15–40 kV) |
| Detector | 25 mm² Silicon Drift Detector (SDD) |
| Cooling | Peltier thermoelectric cooling (down to −35 °C) |
| Filters | 8-position automatic filter wheel |
| Battery | Dual hot-swappable Li-ion batteries |
| Display | High-resolution transflective color touchscreen |
| OS | Windows CE 6.0 |
| Data Storage | MicroSD card (≥100,000 spectra) |
| Connectivity | USB 2.0, Bluetooth 2.1 + EDR |
| Analytical Modes | Up to 25 user-configurable modes |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | DPO6500 |
| Application | Handheld / Portable |
| Industry-Specific Use | Electronics |
| Elemental Range | Na (11) to U (92) |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | < 20 eV |
| Repeatability | ±0.1% RSD |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer | Olympus Corporation |
| Type | Imported Instrument |
| Application | RoHS Compliance Screening |
| Form Factor | Handheld / Portable |
| Regulatory Scope | ASTM F2617-08, HR4040, CPSIA, CPSC, EN 71-3, WEEE, RoHS, REACH, ELV Directive |
| Element Detection Range | Mg (12) to U (92), including Ni, Pb, Cd, Hg, Cr, Br, Cl, and halogen sum (Br + Cl) |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DP4000 |
| Application | Handheld / Field-Portable |
| Industry-Specific Use | Soil and Environmental Monitoring |
| Elemental Range | Na (Z=11) to U (Z=92) |
| Detection Range | 1 ppm – 100% w/w |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability | ≤0.1% RSD (at 1000 ppm, 60 s count time) |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | DP4050 |
| Application | Handheld/Portable |
| Industry-Specific Use | Soil & Environmental Monitoring |
| Elemental Range | Na (11) to U (92) |
| Detection Range | 1 ppm to 100% |
| Energy Resolution | <130 eV |
| Repeatability | ±0.1% |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | DP6050 |
| Application | Handheld / Portable |
| Industry-Specific Use | Electronics |
| Elemental Range | Na (11) to U (92) |
| Quantification Range | 1 ppm to 99.9% |
| Energy Resolution | <130 eV |
| Repeatability | 0.1% |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | GoldXpert |
| Form Factor | Benchtop/Floor-standing |
| Industry Application | Non-ferrous Metals |
| Elemental Range | Na (11) to U (92) |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <50 eV (Mn Kα) |
| Repeatability | ≤0.1% RSD (for Au in certified reference materials) |
| Detector Type | Silicon Drift Detector (SDD) |
| Excitation Source | Micro-focus Rh anode X-ray tube |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Distribution Model | Authorized Distributor |
| Import Status | Imported |
| Model Series | Vanta Element |
| Application | Handheld / Portable |
| Industry Focus | Ferrous Metals |
| Elemental Range | Mg to U |
| Detection Limit | 1 ppm |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV at Mn Kα |
| Repeatability | ≤0.1% RSD (relative standard deviation) |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vanta GX |
| Form Factor | Benchtop |
| Industry Application | Non-Ferrous Metals |
| Elemental Range | Mg (12) – U (92) |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV (Mn Kα) |
| Detector | Silicon Drift Detector (SDD) |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vanta |
| Application | Handheld / Portable |
| Industry Type | General Purpose |
| Elemental Range | Mg to U |
| Detection Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vanta RoHS Series |
| Application | Handheld / Portable |
| Industry-Specific Use | Electronics |
| Elemental Range | Mg–U |
| Detection Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vanta Series |
| Application | Handheld/Portable |
| Industry-Specific Use | Soil & Environmental Monitoring |
| Elemental Range | Mg–U |
| Detection Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vanta Series Alloy Analyzer |
| Application | Handheld / Portable |
| Industry-Specific Type | Non-Ferrous Metals |
| Elemental Analysis Range | Mg to U |
| Quantitative Detection Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | ±0.1% RSD |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | X-5000 |
| Application | Field-deployable portable analysis |
| Industry Focus | Energy & Petrochemicals |
| Elemental Range | Na (11) to U (92) |
| Quantification Range | 1 ppm – 100% |
| Energy Resolution | <150 eV (FWHM at Mn Kα) |
| Repeatability | ±0.1% RSD |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | X-5000a |
| Application | Field-portable soil and sediment analysis |
| Elemental Range | Na to U |
| Detection Range | 1 ppm to 100% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Detector Type | Silicon Drift Detector (SDD) |
| Compliance | EPA Method 6200, ISO/DIS 13196, TCLP, RCRA 8 Metals, ASTM D6729, OSHA/NIOSH/NIH/HUD guidelines |
| Certifications | ISO 9001, NATO AQAPI-110 |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PeDX G5 |
| Application Form Factor | Handheld / Portable |
| Instrument Type | Conventional EDXRF |
| Industry Use | General-Purpose |
| Elemental Range | Al to U (Atomic Number 13–92) |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <136 eV at Mn Kα |
| Repeatability (RSD) | ≤0.1% for homogeneous alloy standards |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | PeDX 980 / PeDX 980S / PeDX 980CS |
| Application | Handheld / Portable |
| Instrument Type | Conventional ED-XRF |
| Industry Use | General-Purpose |
| Elemental Range | Mg to U |
| Detection Range | 1 ppm – 99.99% |
| Energy Resolution | < 136 eV (at Mn Kα) |
| Repeatability | ≤ 0.1% RSD (for repeated measurements under controlled conditions) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | Portable350 |
| Price Range | USD 7,000–14,000 (FOB) |
| Form Factor | Handheld / Field-Deployable |
| Industry-Specific Use | Environmental & Industrial Compliance Monitoring |
| Elemental Range | Mg (Z=12) to U (Z=92) |
| Quantification Range | 1 ppm to 99.99 wt% |
| Energy Resolution | 149 ± 5 eV at Mn Kα |
| Repeatability | RSD ≤ 0.05% (for Fe in certified soil matrix, 60 s measurement) |