Environmental Monitoring Instruments
Filter
Showing 6301–6330 of 9049 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Quantus HP100 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Quantus LP100 |
| Pricing | Available Upon Request |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | QUESTemp |
| Certification | Intrinsically Safe Options Available |
| Sensor Technology | Traditional Wet-Bulb (Models 32/34/36) or Waterless Wet-Bulb (Models 44/46/48N) |
| Compliance | Meets ISO 7243, ACGIH TLV®, OSHA & NIOSH Heat Stress Guidelines |
| Protection Rating | IP54 |
| WBGT Calculation Method | Weighted combination of natural wet-bulb, globe, and dry-bulb temperatures |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 05103 |
| Instrument Type | Propeller Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–100 m/s |
| Accuracy | ±0.3 m/s or ±1% of reading |
| Operating Temperature | −50°C to +50°C |
| Relative Humidity Range | 0–100% RH |
| Startup Wind Speed (Propeller) | 1.0 m/s |
| Startup Wind Speed (Vane) | 1.1 m/s |
| Wind Direction Range | 360° mechanical, 355° electronic (5° dead zone) |
| Wind Direction Accuracy | ±3° |
| Output Options | AC pulse (3 pulses/rev), 0–5 VDC (05103V), or 4–20 mA (05103L) |
| Power Supply | 15 VDC (sensor only) |
| Housing Material | UV-stabilized polymer with stainless steel and anodized aluminum hardware |
| Bearing Type | Precision stainless steel ball bearings |
| Mounting | Standard 1-inch NPT pipe thread |
| Weight | 1.0 kg (sensor), 2.3 kg (shipping) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 05106 |
| Instrument Type | Propeller Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–100 m/s |
| Accuracy | ±3% of reading or ±0.3 m/s (whichever is greater) |
| Operating Temperature | −50°C to +60°C |
| Relative Humidity Range | 0–100% RH |
| Wind Direction Range | 360° mechanical, 355° electronic (5° dead zone) |
| Wind Direction Accuracy | ±3° |
| Startup Wind Speed | 1.0 m/s (propeller), 1.1 m/s (vane) |
| Output | Magnetic pulse (3 pulses/rev) for wind speed |
| Power Supply | 15 VDC excitation (sensor) |
| Dimensions | 55 cm length × 37 cm height × 18 cm propeller diameter |
| Mounting | Standard 1-inch NPT pipe thread |
| Weight | 1.0 kg (sensor only), 2.3 kg (shipping) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 05108 |
| Instrument Type | Propeller Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–100 m/s |
| Accuracy | ±3% of reading |
| Operating Temperature | −50°C to +60°C |
| Operating Humidity | 0–100% RH |
| Bearing Material | Ultra-durable ceramic |
| Output | Magnetic pulse (3 pulses/rev, 1 rev = 0.5 m air travel) |
| Propeller Diameter | 18 cm |
| Sensor Height | 40 cm |
| Total Length | 57 cm |
| Mounting Tube Diameter | 34 mm (1-inch standard pipe) |
| Weight | 1.0 kg |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 05108-45 |
| Instrument Type | Cup Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–100 m/s |
| Accuracy | ±3% of reading or ±0.3 m/s (whichever is greater) |
| Operating Temperature | −50°C to +60°C |
| Operating Humidity | 0–100% RH |
| Bearing Material | High-Wear-Resistant Ceramic |
| Output Signal | Magnetic pulse (3 pulses per revolution |
| Propeller Diameter | 18 cm |
| Overall Height | 40 cm |
| Length (including propeller) | 57 cm |
| Mounting Tube Diameter | 34 mm (1-inch standard pipe) |
| Weight | 1.0 kg |
| Ice-Resistant Coating | Yes |
| Color Finish | Matte Black (enhances solar heating for passive de-icing) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 05305 |
| Instrument Type | Cup Anemometer & Wind Vane Sensor |
| Resolution | 0.1 m/s |
| Measurement Range | 0–50 m/s (wind speed), 0–360° (wind direction) |
| Accuracy | ±0.2 m/s or ±1% of reading (wind speed), ±3° (wind direction) |
| Startup Wind Speed | 0.4 m/s (cup), 0.5 m/s (vane) |
| Operating Temperature | −50°C to +50°C |
| Operating Humidity | 0–100% RH |
| Output Options | AC pulse (3 pulses/rev), 0–5 VDC, or 4–20 mA |
| Housing Material | UV-stabilized polymer with stainless steel and anodized aluminum hardware |
| Bearing Type | Precision stainless steel ball bearings |
| Compliance | EPA PSD Guidelines, NRC RG 1.23, ANSI/ANS-18.1 |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 05501LM |
| Instrument Type | Propeller Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–60 m/s (continuous), 0–50 m/s (rated), 100 m/s (gust) |
| Accuracy | ±0.3 m/s or ±1% of reading (wind speed), ±3° (wind direction) |
| Operating Temperature | −50°C to +50°C |
| Operating Humidity | 0–100% RH |
| Output | Dual 4–20 mA (wind speed: 0–50 m/s standard, 0–100 m/s optional |
| wind direction | 0–360°) |
| Power Supply | 8–30 VDC, ≤40 mA |
| Startup Velocity | 1.0 m/s (propeller), 1.1 m/s (vane) |
| Dynamic Response | Propeller distance constant 2.7 m, vane lag distance 1.3 m, damping ratio 0.3 |
| Construction | Stainless steel shaft & bearings, anodized aluminum housing, UV-stabilized polymer components |
| Mounting | Standard 1-inch NPT pipe thread (34 mm OD) |
| Sensor Weight | 1.0 kg |
| Shipping Weight | 2.3 kg |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 09101 |
| Instrument Type | Propeller Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–100 m/s |
| Accuracy | ±2% of reading or ±0.3 m/s (whichever is greater) |
| Operating Temperature | −50°C to +50°C |
| Operating Humidity | 0–100% RH |
| Output Interface | RS-485 serial (RMY/NCAR/NMEA protocols) |
| Startup Wind Speed | 1.0 m/s |
| Bearing Type | Precision stainless steel ball bearing |
| Mounting | Standard 1-inch NPT pipe thread |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 61402 |
| Output Options | 0–5 VDC (61402V), 4–20 mA (61402L), SDI-12, RS-232, RS-485 (61402L only) |
| Measurement Range | 500–1100 hPa |
| Digital Accuracy | ±0.2 hPa @ 25°C, ±0.3 hPa @ −50 to +60°C |
| Analog Accuracy | ±0.05% of full scale |
| Temperature Coefficient | 0.0017% FS/°C |
| Long-Term Stability | 0.08% FS/year |
| Resolution | 0.01 hPa (digital), 0.025% FS (analog) |
| Update Rate | up to 1.8 Hz |
| Power Supply | 7–30 VDC |
| Current Consumption | <4 mA (active), 2.7 µA (sleep mode) |
| Dimensions | 90 × 60 × 20 mm |
| Weight | 44 g |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 73000 |
| Weight | 8 kg |
| Operating Temperature | -40 to +60 °C |
| Supply Voltage | 10–36 VDC |
| Measurement Range | 30 m – 16 km |
| Accuracy | ±10% RMSE |
| Time Constant | 60 s |
| Scattering Angle | 42° (nominal) |
| Output Options | 0–10 VDC |
| Relay Options | 2 control relays, 1 diagnostic relay |
| Power Consumption | 6 VA (nominal), 18 VA (with heated shroud) |
| Ingress Protection | IP66 (NEMA-4X) |
| Dimensions | 889 mm × 292 mm × 305 mm (W × H × D) |
| Mounting | 48 mm (1.9″) for 1.5″ IPS pipe (standard), optional 34 mm (1.3″) for 1″ IPS pipe |
| Housing Material | Anodized aluminum frame, UV-stabilized fiberglass enclosure |
| Compliance | EN 61326-1:2010, EMC Directive 2014/30/EU, RoHS Directive 2011/65/EU |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 81000 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Wind Speed Range | 0–40 m/s |
| Accuracy | ±1% (0–30 m/s), ±3% (30–40 m/s) |
| Operating Temperature | −50 to +50 °C |
| Relative Humidity Range | 0–100% RH |
| Wind Direction Range | 0–360° |
| Elevation Angle Range | ±60° |
| Sonic Temperature Range | −50 to +50 °C |
| Output Options | RS-232 / RS-485 serial, 4-channel analog voltage (81000) |
| Sampling Rate | Up to 160 Hz |
| Output Frequency | User-selectable 4–32 Hz |
| Power Supply | 12–24 VDC, 110 mA |
| Dimensions | 55 cm height × 17 cm diameter |
| Weight | 1.7 kg |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 81000V |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Wind Speed Range | 0–40 m/s |
| Accuracy | ±1% (0–30 m/s), ±3% (30–40 m/s) |
| Operating Temperature | −50°C to +50°C |
| Operating Humidity | 0–100% RH |
| Wind Direction Range | 0–360° |
| Elevation Angle Range | ±60° |
| Sonic Temperature Range | −50°C to +50°C |
| Output Options | RS-232 / RS-485 serial, 4-channel analog voltage input (81000V), sampling rate up to 160 Hz, user-selectable output frequency (4–32 Hz) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 86000 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Wind Speed Range | 0–75 m/s |
| Accuracy | ±2% (0–30 m/s), ±3% (30–70 m/s), or ±0.1 m/s (whichever is greater) |
| Wind Direction Range | 0–360° |
| Wind Direction Resolution | 0.1° |
| Wind Direction Accuracy | ±2° |
| Startup Threshold | 0.01 m/s |
| Response Time | <0.25 s |
| Operating Temperature | −40°C to +60°C |
| Humidity Range | 0–100% RH |
| Output Options | RS-232/RS-485, 0–5 VDC analog, 4–20 mA current loop, SDI-12 |
| Enclosure Rating | IP65 |
| Dimensions | 29 cm H × 11 cm W |
| Weight | 0.4 kg |
| Power Supply | 10–30 VDC (standard), 24 VDC/2.5 A (heated model 86004) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 86004 |
| Instrument Type | Ultrasonic Anemometer |
| Wind Speed Range | 0–75 m/s |
| Resolution | 0.01 m/s |
| Accuracy | ±2% (0–30 m/s), ±3% (30–70 m/s) |
| Wind Direction Range | 0–360° |
| Wind Direction Resolution | 0.1° |
| Wind Direction Accuracy | ±2° |
| Startup Wind Speed | 0.01 m/s |
| Response Time | <0.25 s |
| Operating Temperature | −40 to +60 °C |
| Relative Humidity | 0–100 %RH |
| Output Options | RS-232/RS-485, ASCII/RMYT/NMEA/SDI-12, 0–5 V / 4–20 mA |
| Analog Wind Speed Range | 0–100 m/s |
| Analog Wind Direction Range | 0–360° or 0–540° |
| Output Frequency | 0.1–20 Hz |
| Power Supply | 10–30 VDC (heater: 24 VDC, 2.5 A) |
| Current Draw | <20 mA (non-heating) |
| IP Rating | IP65 |
| Dimensions | 29 cm H × 11 cm W |
| Weight | 0.4 kg (unit), 1.6 kg (shipping) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 86106 |
| Instrument Type | Ultrasonic Anemometer |
| Wind Speed Range | 0–75 m/s |
| Resolution | 0.01 m/s |
| Accuracy | ±2% (0–30 m/s), ±3% (30–70 m/s) |
| Wind Direction Range | 0–360° |
| Wind Direction Resolution | 0.1° |
| Wind Direction Accuracy | ±2° |
| Startup Threshold | 0.01 m/s |
| Response Time | <0.25 s |
| Operating Temperature | −40 to +60 °C |
| Relative Humidity | 0–100% RH |
| Output Options | NMEA 0183, RS-232/RS-485, Analog (0–5 V / 4–20 mA) |
| Enclosure Rating | IP65 |
| Dimensions | 29 cm H × 11 cm W |
| Weight | 0.4 kg |
| Power Supply | 10–30 VDC (heater: 24 VDC, 2.5 A for heated variants) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 91000 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–75 m/s |
| Accuracy | ±2% |
| Operating Temperature | −50°C to +60°C |
| Operating Humidity | 0–100% RH |
| Ingress Protection | IP66 |
| Sampling Rate | Up to 10 Hz |
| Output Protocols | SDI-12, NMEA 0183, ASCII Serial |
| Mounting | Standard 1-inch IPS pipe thread |
| Housing Material | Corrosion-resistant anodized aluminum |
| Color Options | Black or White |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 09106 |
| Instrument Type | Propeller Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–100 m/s |
| Accuracy | ±2% of reading or ±0.3 m/s (whichever is greater) |
| Operating Temperature | −50°C to +50°C |
| Relative Humidity Range | 0–100% RH |
| Wind Direction Range | 0–360° |
| Wind Direction Resolution | 1° |
| Wind Direction Accuracy | ±2° |
| Startup Wind Speed (Propeller) | 1.0 m/s |
| Output Interface | RS-485 serial (RMY, NCAR, or NMEA protocol), configurable for polled or continuous mode |
| Power Supply | 11–24 VDC, 20 mA |
| Dimensions (H × L) | 37 cm × 55 cm |
| Propeller Diameter | 18 cm |
| Mounting Tube Diameter | 34 mm (1-inch standard pipe) |
| Sensor Weight | 1.0 kg |
| Shipping Weight | 2.3 kg |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 92000 |
| Instrument Type | Portable Weather Station |
| Output Interfaces | SDI-12, NMEA 0183, ASCII Serial |
| Communication Options | RS-232 or RS-485 |
| Mounting | 1-inch IPS pipe thread |
| Housing Material | Corrosion-resistant anodized aluminum |
| Power Supply | 6–24 VDC |
| Operating Temperature | −40 °C to +70 °C |
| IP Rating | IP66 |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | RA-915J |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RADALERT100 |
| Instrument Type | Dose Rate / Exposure Rate Meter |
| Detection Capabilities | Alpha, Beta, Gamma, and X-ray Radiation |
| Calibration Source | Cs-137 (Gamma) |
| Dose Rate Range | 0.001–110.0 mR/hr or 0.01–1100 µSv/hr |
| Display | 4-digit LCD with mode indicators |
| Counting Range | CPM: 0–350,000 |
| CPS | 0–3,500 |
| Total Count | 1–9,999.00 |
| Sensitivity | 1,000 CPM per mR/hr (Cs-137) |
| Accuracy | ±10% typical, ±15% maximum |
| Audible/Visual Alarm | User-adjustable threshold up to 50 mR/hr and 160,000 CPM |
| Output Interface | Dual-purpose 3.5 mm mini-jack (CMOS-compatible TTL pulse output) |
| Power Supply | 9 V alkaline battery (2160 h typical at background |
| Dimensions & Weight | 150 × 80 × 30 mm, 225 g (including battery) |
| Compliance | CE-marked per EU Directive 2014/30/EU (EMC) and 2014/53/EU (Radio Equipment), compliant with IEC 60846-1:2014 for portable radiation protection instrumentation |
| Brand | Radcal (USA) |
|---|---|
| Origin | USA |
| Model | Rapid-Gold+ Touch Pro |
| Dimensions | 114 × 92 × 158 mm |
| Weight | 700 g |
| Display | 5″ capacitive TFT LCD (800×480) |
| Battery | 5.5 Ah Li-polymer, >8 h operation |
| Connectivity | USB 2.0 (Micro-B), Wi-Fi 802.11b/g/n (2.4 GHz, WPA2) |
| Storage | 16 GB internal flash (>100,000 exposures) |
| Compliance | IEC 61674, EN 61326-1:2013 (Group 1, Class B), EN 61000-4-x series |
| Operating Temp | 15–35 °C |
| Humidity | ≤80% RH or ≤20 g/m³ |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Radiation and Contraband Detection System |
| Model | RadEye CD |
| Detector Type | RadEye SX with NaI(Tl) Scintillation Detector |
| Measurement Capability | Simultaneous detection of concealed contraband (e.g., tobacco, explosives, alcohol) and radioactive materials |
| Measurement Range | 5–10 cps (background), 50–100 cps (contraband presence) |
| Sensitivity | ≥5 cps minimum detectable signal above background |
| Analysis Channels | Dual-channel spectral analysis |
| Typical Background Count Rate | 5 cps |
| Effective Measurement Time | 1 second per acquisition |
| Regulatory Compliance | Designed for customs, border security, and port-of-entry applications in accordance with IAEA TS-G-1.2 and ANSI N42.34 standards |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Model | RadEye GR |
| Instrument Type | Portable Dose Rate Meter |
| Detector Type | Sodium Iodide (NaI) Scintillator |
| Wireless Range | 100 m |
| Detector Battery Life | 1300 h |
| Display Unit (RadEye R) Battery Life | 600 h |
| Operating Temperature | –25 °C to +50 °C |
| Compliance | Meets ANSI N42.33, IEC 60846-1:2014, and EU Directive 2013/59/Euratom for portable radiation monitoring devices |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Radalert100 |
| Instrument Type | Portable Radiation Survey Meter |
| Detection Modes | α, β, γ, X-ray |
| Display | LCD with Dual-Unit Readout (mR/hr, µSv/hr, CPM, CPS, Total Count) |
| Measurement Ranges | 0.001–110 mR/hr |
| Timer Function | Up to 40 hours |
| Accuracy | ±10% of reading (±15% max in mR/hr and µSv/hr modes) |
| Detector | Halogen-quenched GM tube calibrated to Cs-137 (1000 cpm/mR/hr sensitivity) |
| Interface | RS-232 serial port for PC connectivity and data logging |
| Dimensions (L×W×H) | 8 × 3 × 15 cm |
| Audible/Visual Alarms | Adjustable threshold with red LED flash and piezoelectric buzzer |
| Power | 9 V alkaline battery (typical life: 2000+ hours) |
| Brand | -- |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CRM-100 |
| Instrument Type | Portable Dose Rate Meter |
| Measured Radiation Types | Alpha (α), Beta (β), Gamma (γ), and X-ray |
| Detector | Halogen-quenched Geiger-Müller Tube with Mica End-window (1.75″ / 45 mm diameter, density 1.5–2.0 mg/cm²) |
| Wall Material | 0.012″ stainless steel (Grade 446) |
| Energy Range | 20 keV – 3 MeV |
| Dose Rate Range | 0.001–110.0 mR/h or 0.01–1100 µSv/h |
| Count Rate Range | 0–3,500 CPS / 0–350,000 CPM |
| Total Count Capacity | Up to 9,999,000 counts |
| Timer Range | Up to 40 hours |
| Sensitivity | ≥1000 CPM per mR/h (referenced to Cs-137) |
| Accuracy | ±10% typical, ±15% maximum (mR/h and µSv/h modes) |
| Display | 4-digit LCD with mode indicators |
| Audio Feedback | Adjustable click-per-count (muteable) |
| Visual Feedback | LED flash per count |
| Interface | 3.5 mm output jack (CMOS-compatible TTL pulses) |
| Power | One 9 V alkaline battery (typical lifespan: 2160 hours) |
| Dimensions | 150 × 80 × 30 mm |
| Weight | 225 g (including battery) |
| Certifications | CE, RoHS, WEEE, ISO 9001:2001 & ISO 14001 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | R2D |
| Instrument Type | Dose Rate & Spectrometry Analyzer |
| Detector | 3" × 3" NaI(Tl) Scintillation Crystal |
| Energy Range | 40 keV – 2 MeV (adjustable) |
| Energy Resolution | ≤7.5% FWHM at 662 keV (¹³⁷Cs) |
| MCA Channels | 4096 |
| Maximum Throughput | 13 Mcps |
| Power Supply | USB-powered (140–300 mA) |
| Integral Nonlinearity | ≤±0.05% |
| Differential Nonlinearity | ≤1% |
| Shielding | LX705S Lead Castle — 125 mm electrolytic high-purity lead, 3 mm oxygen-free copper inner liner, lever-actuated hinged door |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RadScan 900+ |
| Price | USD 1,280 (FOB Hamburg) |
| Detection Types | α, β, γ, X-rays |
| Dose Rate Range | 0.01–1000 µSv/h |
| Pulse Rate Range | 0–30,000 cpm / 0–5,000 cps |
| Cumulative Dose Range | 0.001 µSv–999,999 Sv |
| Sensitivity | ≥108 pulses per µSv/h (Co-60) |
| Operating Temperature | −40 °C to +75 °C |
| Dimensions | 170 × 74 × 30 mm |
| Weight | 250 g |
| Power | 3 × AAA alkaline batteries (30-day continuous operation) |
| Compliance | CE Directive 2014/30/EU (EMC), 2014/53/EU (RED), FCC Part 15 Subpart B |
| Calibration Interval | 5 years (traceable to PTB standards) |
| Brand | RAE Systems Inc. (USA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PGM-5520 |
| Instrument Type | Portable |
| Detectable Gases | O₂, LEL (Combustible Gas), CO, H₂S |
| Response Time | ≤15 s |
| Measurement Resolution | 1 ppm |
| Measurement Ranges | O₂ (0–30% vol), LEL (0–100% LEL), CO (0–500 ppm), H₂S (0–100 ppm) |
| Wireless Frequency | 915 MHz |
| Integrated Sampling Pump | Yes |
| IP Rating | IP67 (per ASTM E2782 & IEC 60529) |
| Battery Life | Up to 24 h (typical, with Li-ion battery) |
| Data Logging Capacity | ≥100,000 data points |
| Simultaneous Monitoring Channels | Up to 32 units per base station |
| Mounting | Bi-Pod stand (50 cm elevation, tool-free attachment) |