Environmental Monitoring Instruments
Filter
Showing 6391–6420 of 9029 results
| Brand | Rikari |
|---|---|
| Origin | Japan |
| Model | DO-11Z |
| Instrument Type | Portable |
| Measurement Principle | Galvanic Cell Electrochemical Probe |
| Measurement Range | 0–20 mg/L |
| Accuracy | ±2% of reading |
| Repeatability | ±2% of reading |
| Detection Limit | 0.01 mg/L |
| Sensor Type | Cylindrical OXNIT Galvanic Probe with Replaceable Membrane |
| Enclosure Rating | IP67 |
| Display Resolution | Adjustable between 0.01 mg/L and 0.1 mg/L |
| Brand | Rikari |
|---|---|
| Origin | Japan |
| Model | RC-3F |
| Instrument Type | Portable |
| Measurement Principle | DPD Spectrophotometry |
| Measured Parameter | Free Chlorine (as Cl₂) |
| Range | 0–500 mg/L |
| Accuracy | ±2% of reading |
| Repeatability | ±2% RSD |
| Resolution | 1 mg/L |
| LOD | 1 mg/L |
| Power | 4 × AAA alkaline batteries (DC 6 V) |
| Operating Temperature | 5–35 °C |
| Dimensions | 75 × 180 × 38 mm (W × D × H) |
| Sample Volume | 5 mL |
| Reagent | HOCl-K-1 powder packet (single-use, pre-dosed) |
| Display | 3-digit LCD |
| Auto-off | 5 seconds after measurement |
| Hold function | Yes |
| Over-range alert | Flashing display above 550 mg/L |
| Brand | Rikari |
|---|---|
| Origin | Japan |
| Model | RC-V7 |
| Instrument Type | Portable |
| Measurement Principle | UV-LED Absorption Photometry (Deep UV, 254 nm) |
| Measured Parameter | Residual Chlorine (as Cl₂), Chlorine Dioxide (ClO₂) |
| Range Mode 1 | 0–1000 mg/L |
| Range Mode 2 | 0–500 mg/L |
| Accuracy | ±1% of reading |
| Repeatability | ±2% (under controlled conditions) |
| Resolution | 1 mg/L |
| LOD | 1 mg/L |
| Operating Temperature | 1–35 °C |
| Power Supply | 4 × AA alkaline batteries (DC 6 V) |
| Weight | ~310 g |
| Brand | Rikari |
|---|---|
| Origin | Japan |
| Model | TRC-30 |
| Measurement Principle | Dual-Beam Transmittance Photometry (Spectrophotometric Method) |
| Turbidity Range | 0.0–50.0 NTU (Polystyrene Standard) |
| Color Range | 0.0–50.0 Pt-Co Units (Platinum-Cobalt Scale) |
| Resolution | 0.01 unit (0.0–9.99), 0.1 unit (10.0–50.0) |
| Repeatability | ±0.2 units under specified conditions |
| Operating Temperature | 5–35 °C |
| Protection Rating | IP63 (Dust-Resistant & Drip-Protected) |
| Power Supply | 4 × AA Alkaline Batteries (DC 6 V) |
| Dimensions | 54 × 38 × 350 mm |
| Weight | Approx. 300 g |
| Calibration | Zero-point with deionized water |
| Compliance | Aligns with MHLW Ordinance on Water Quality Standards for Public Water Supply (Japan), Industrial Water Testing Methods, and JIS K 0102 Annex B (Transmittance Method) |
| Brand | Riken |
|---|---|
| Origin | Japan |
| Model | FP-30MK2(C) |
| Detection Principle | Photometric Colorimetry (based on acetylacetone reaction) |
| Measurement Range | 0.000–0.50 mg/m³ (TAB No.008) |
| Resolution | 0.01 mg/m³ (TAB No.008) |
| Repeatability | ≤ ±7% of reading |
| Sampling Method | Pump-aspirated |
| Response Time | 900 s (15 min) for TAB No.009 |
| Operating Temperature | −10 to +40 °C |
| Operating Humidity | ≤90% RH (non-condensing) |
| Flow Rate | 0.5 L/min |
| Data Storage | 99 measurement records with timestamp |
| Power Supply | 4 × AA alkaline batteries |
| Battery Life | Approx. 12 h (at 20 °C, no backlight, no alarm) |
| Dimensions | 80 × 150 × 40 mm (W×H×D, excluding protrusions) |
| Weight | ~250 g (excluding batteries) |
| Brand | Riken Keiki |
|---|---|
| Origin | Japan |
| Model | CL-502 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Solid-State Membrane Chloride-Selective Electrode (CSE) |
| Measuring Range | 10–1000 mg/L (customizable up to >1000 mg/L) |
| Detection Limit | 1 mg/L |
| Response Time | ≤1 s |
| Accuracy | ±1% of full scale |
| Repeatability | ±2% FS |
| pH Operating Range | 3.0–10.0 |
| Output Signal | Isolated DC 4–20 mA (load ≤500 Ω, three selectable ranges: 0–100 / 0–500 / 0–1000 mg/L) |
| Power Supply | AC 85–240 V, 50/60 Hz |
| Operating Environment | 0–40 °C, ≤85% RH |
| Dimensions | 96 W × 96 H × 163 D mm |
| Weight | ~1.3 kg |
| Compliance | Designed for continuous industrial water monitoring per ISO 5667-3 and ASTM D3370 guidelines |
| Electrode Configuration | Dual-junction reference electrode with solid-state chloride-selective membrane, maintenance-free internal electrolyte |
| Brand | Riken Keiki |
|---|---|
| Model | F-10Z |
| Type | Portable Fluoride-Specific Ion Analyzer |
| Measurement Principle | Solid-State Lanthanum Fluoride (LaF₃) Single-Crystal Membrane Electrode |
| Measuring Range | 0–2000 mg/L F⁻ |
| Detection Limit | 1 mg/L F⁻ |
| Resolution | 0.1 mg/L (0.1–99.9 mg/L), 1 mg/L (100–2000 mg/L) |
| Accuracy | ±1% of reading |
| Response Time | ≤10 s (t₉₀) |
| Temperature Compensation | Automatic, semiconductor-based (0–45 °C) |
| Display | 4-digit LCD (F⁻: mg/L |
| mV | −1000 to +1000 mV) |
| Reproducibility | ±2 mg/L (≤99.9 mg/L), ±5 mg/L (100–2000 mg/L) |
| Calibration | Two-point using certified F⁻ standards (2 mg/L and 200 mg/L) |
| Memory Capacity | 30 measurement records |
| Ingress Protection | IP67 |
| Power Supply | DC 4.5 V (3 × AAA LR03 batteries) |
| Auto-Power-Off | After 30 min idle |
| Dimensions | 70 × 36 × 170 mm (W × H × D) |
| Weight | ~290 g (incl. batteries) |
| Housing Material | ABS plastic |
| Compliance | RoHS-compliant, lead-free soldering |
| Brand | Riken Keiki |
|---|---|
| Origin | Japan |
| Model | FP-30MK2(C) |
| Principle | Photometric Colorimetry |
| Measurement Range | 0–0.4 ppm / 0–1.0 ppm (equivalent to 0–0.50 mg/m³ / 0–1.250 mg/m³) |
| Resolution | 0.01 mg/m³ (low range) / 0.025 mg/m³ (high range) |
| Repeatability | ±5% of reading (typical, per JIS B 7981 and GB/T 18204.2–2014) |
| Sampling Method | Pump-aspirated |
| Response Time | t₉₅% ≤ 180 s |
| Operating Temperature | −10 °C to +40 °C |
| Operating Humidity | ≤90% RH, non-condensing |
| Flow Rate | 0.5 L/min |
| Data Storage | 99 auto-saved records |
| Battery Life | ~12 h (4 × AA alkaline, 20 °C, no backlight/alarm) |
| Dimensions | 80 × 150 × 40 mm (W×H×D) |
| Weight | ~250 g (excl. batteries) |
| Certifications | CPA (China Metrology Accreditation), compliant with GB/T 18204.2–2014 and JIS B 7981 |
| Brand | RIKEN KEIKI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TAB-008 / TAB-009 |
| Pricing | Upon Request |
| Detection Principle | Photometric Colorimetry |
| Sampling Method | Pump-Driven Active Inhalation |
| Flow Rate | 0.5 L/min |
| Measurement Range | 0.000–0.500 mg/m³ (TAB-008) |
| Display Resolution | 0.01 mg/m³ (TAB-008) |
| Integration Time | 1800 s (30 min) for TAB-008 |
| Pack Size | 20 strips per pack |
| Brand | RIKEN KEIKI |
|---|---|
| Origin | Japan |
| Model | RX-8500 |
| Type | Portable Multicomponent Gas Detector |
| Detection Principles | NDIR (CH₄, CO₂), Galvanic Cell (O₂), Electrochemical (CO) |
| Response Time | ≤15 s |
| Detection Ranges | CH₄: 0–100% LEL / 5–100 vol% (auto-ranging) |
| O₂ | 0–25 vol% |
| CO | 0–1000 ppm |
| CO₂ | 0–20 vol% |
| Sampling Method | Pump-aspirated |
| Power Supply | Rechargeable Li-ion battery (≈15 h) or 3×AA alkaline batteries (≈8 h) |
| Dimensions | 154(W) × 81(H) × 163(D) mm (excl. protrusions) |
| Weight | ≈1.2 kg (Li-ion), ≈1.1 kg (AA) |
| Operating Environment | −20 to +50 °C, ≤95% RH (non-condensing) |
| Intrinsic Safety Rating | Ex ia II CT4X |
| Certifications | TIIS, ATEX, CE, SOLAS-compliant |
| Brand | RIKEN KEIKI |
|---|---|
| Origin | Japan |
| Model | SP-230 ML |
| Detection Principle | Hot-Wire Semiconductor Sensor |
| Detection Method | Draw-in (Pump-Assisted) Sampling |
| Gas Types | CH₄ (Natural Gas), i-C₄H₁₀ (LPG) |
| Measurement Range | 10–2000 ppm |
| Alarm Setpoints | 10, 30, 150, 500, 2000 ppm (default: 30 ppm) |
| Alarm Output | Visual (flashing LED), Audible (buzzer) |
| Explosion Protection | Intrinsic Safety, II 2G Ex ic IIC T4 Ga |
| IP Rating | IP67 |
| Operating Temperature | −20 to +55 °C |
| Operating Humidity | ≤95% RH (non-condensing) |
| Battery | 2 × AA alkaline, ~13 h continuous operation (25 °C, no alarm, no light, no Bluetooth) |
| Dimensions | 41 (W) × 186 (H) × 38 (D) mm (excl. probe) |
| Weight | ~220 g (excl. batteries) |
| Wireless | Bluetooth 4.2 Low Energy (BLE) |
| Brand | Rikori |
|---|---|
| Origin | Japan |
| Model | H2O2-V7 |
| Instrument Type | Portable |
| Measurement Principle | UV Absorption Photometry (254 nm LED source) |
| Measurement Parameter | Hydrogen Peroxide (H₂O₂) |
| Range | 0–4000 mg/L (ppm) |
| Accuracy | ±2% of full scale |
| Repeatability | ±2% of full scale |
| Resolution | 1 mg/L |
| Detection Limit | 0.5 mg/L |
| Response Time | ≤10 s |
| Operating Temperature | 1–35 °C |
| Power Supply | DC 6 V |
| Dimensions | 88 × 174 × 65 mm |
| Weight | 310 g |
| Compliance | Designed for industrial process monitoring per ISO 7027 principles (UV absorbance-based quantification), compatible with GLP-aligned data recording workflows |
| Brand | Rikori |
|---|---|
| Origin | Japan |
| Model | H2SO4-55 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measurement Parameter | Sulfuric Acid Concentration |
| Range | 0.0–199.9 g/L |
| Resolution | 0.1 g/L |
| Repeatability | ±5% FS |
| Reproducibility | ≤5% |
| Response Time | 5 s after power-on |
| Measurement Time | ~60 s per sample |
| Auto-Power-Off | 5 s after measurement hold |
| Calibration | Zero and span calibration required prior to use |
| Light Source | LED |
| Power Supply | 4× AAA alkaline batteries (LR03), DC 6 V |
| Dimensions | 88 × 174 × 65 mm (W×D×H) |
| Weight | ~310 g |
| Standard Accessories | Instrument body, 4× AAA batteries, three cuvettes, H2SO4-RA reagent (500 mL), span calibration cuvette (1×), 5-mL dropper, 0.1-mL micropipette, instruction manual, warranty card, carrying case |
| Brand | Rikorika |
|---|---|
| Origin | Japan |
| Model | CL-11Z |
| Instrument Type | Portable |
| Measurement Range | 0–2000 mg/L (ppm) Cl⁻ |
| Detection Limit | 0.1 mg/L |
| Response Time | 1 s |
| Accuracy | ±2% of reading |
| Temperature Compensation | Automatic (NTC thermistor) |
| Operating Temperature | 0–45 °C |
| IP Rating | IP67 |
| Display | 4-digit LCD with backlight |
| Resolution | 0.1 mg/L (0.1–99.9 mg/L), 1 mg/L (100–2000 mg/L) |
| Repeatability | ±2 mg/L (0.1–99.9 mg/L), ±5 mg/L (100–2000 mg/L) |
| Memory Capacity | 30 data points |
| Dimensions (main unit) | 70 × 40 × 173 mm (W × H × D) |
| Weight (main unit + electrode + 1 m cable) | ~430 g |
| Standard Accessories | CLD-11 chloride-selective electrode, CLSLN-10-50 & CLSLN-1000-50 standard solutions (50 mL each), CLDLQ-30 internal filling solution (30 mL), two syringes, ISAB solution (50 mL), user manual, warranty card, AA batteries |
| Brand | Rikorika |
|---|---|
| Origin | Japan |
| Model | SSTR-5Z |
| Instrument Type | Portable/HANDHELD Water Quality Analyzer |
| Measured Parameters | Turbidity (NTU), Suspended Solids (SS, mg/L) |
| Measurement Principle | Near-Infrared 90° Scattered Light Detection |
| Light Source | LED with Auto-Brightness Compensation |
| Detection Method | Ratio-metric dual-beam (sample + reference channel) |
| Display | 4-digit LCD |
| Turbidity Range | 0–500 NTU |
| SS Range | 0–500 mg/L (extendable to 1000 mg/L via range switching) |
| Resolution | 0.1 NTU/mg/L (0–199.9), 1 NTU/mg/L (200–500), 0.01 NTU/mg/L (full scale 1000) |
| Repeatability | ≤ ±2% FS (under specified conditions) |
| Zero Calibration | Deionized water or dedicated zero calibration plate |
| Span Calibration | Hydrazine-based turbidity standard (Formazin) or direct SS calibration using lab-analyzed sample |
| SS Conversion Function | Linear regression y = a + bx (user-configurable coefficients) |
| Operating Temperature | 0–40°C |
| Sample Temp. Range | 5–40°C |
| Immersion Materials | PVC, Borosilicate Glass, SUS-304 Stainless Steel |
| Probe Dimensions | Ø53 × 270 mm |
| Cable Length | 6 m |
| Weight | ~500 g (probe only, excluding cable) |
| Power Supply | 3 × AAA alkaline (LR03), auto-power-off enabled |
| Self-Diagnostic Functions | Battery voltage monitoring, calibration error detection, photodetector fault alert |
| IP Rating | IP67 (probe body) |
| Brand | Rikorika |
|---|---|
| Origin | Japan |
| Model | TCR-5Z |
| Instrument Type | Portable/HANDHELD Water Quality Analyzer |
| Measurement Parameters | Turbidity, Color (Platinum-Cobalt Scale), Absorbance |
| Measurement Principle | Dual-beam Transmittance Photometry (Spectrophotometric Method) |
| Range | Turbidity 0.0–50.0 NTU (Polystyrene Standard), Color 0.0–50.0° (Pt-Co Scale), Absorbance 0.000–1.999 Abs |
| Resolution | 0.1° (0.01° selectable below 10°), 0.001 Abs |
| Repeatability | ±0.5° under specified conditions |
| IP Rating | IP66 (when probe connector is properly mated) |
| Power | 3× AAA alkaline batteries (DC 4.5 V) |
| Operating Temperature | 5–35 °C |
| Dimensions (Main Unit) | 38 × 75 × 180 mm |
| Weight (Main Unit) | ~270 g |
| (Probe TCR-5ZD) | ~350 g (excl. cable) |
| Cable Length | 2 m |
| Brand | Rikorika |
|---|---|
| Origin | Japan |
| Model | TP-10Z |
| Measurement Wavelength | 880 nm (NIR) |
| Transmittance Range | 2.0–200 cm |
| Absorbance Range | 0.000–2.000 Abs/60 mm |
| Resolution | 0.1 cm (2.0–99.9 cm), 1 cm (100–200 cm), 0.001 Abs |
| Repeatability | ±3% FS or better |
| Operating Temperature | 0–40 °C, ≤95% RH |
| IP Rating | IP67 (when probe fully mated) |
| Power Supply | 4.5 V DC (3×AAA alkaline batteries) |
| Dimensions | 70×170×36 mm |
| Weight | ~270 g (including batteries) |
| Standard Accessories | Fluoride ion sensor, shock-absorbing rubber cap, PVC sample cell, calibration filter, user manual |
| Brand | Rikorika |
|---|---|
| Model | TP-30 |
| Origin | Japan |
| Measurement Principle | Near-infrared transmittance (880 nm) |
| Optical Path Length | 60 mm |
| Measurement Range | 2.0–200 cm |
| Resolution | 0.1 cm (2.0–99.9 cm), 1 cm (100–200 cm) |
| Accuracy | ±3% FS or better |
| Repeatability | ±3% FS |
| Operating Temperature | 2–40 °C (water), 0–40 °C (ambient) |
| Humidity Limit | ≤95% RH |
| Ingress Protection | IP63 (dust-resistant and splash-proof) |
| Power Supply | 4 × AA alkaline batteries (DC 6 V) |
| Auto Power-off | Yes |
| Housing Material | POM + rubberized impact-absorbing casing |
| Dimensions | 48 × 32 × 320 mm |
| Weight | ~300 g |
| Standard Accessories | Fluoride ion sensor module, shock-absorbing protective cap, PVC sample cell, calibration filter, user manual, batteries |
| Brand | Rikorika |
|---|---|
| Origin | Japan |
| Model | TR-55 |
| Measurement Principle | 90° Nephelometric Detection with Near-Infrared Light Source |
| Range | 0.1–1000 NTU (3-range auto-scaling) |
| Resolution | 0.01 NTU (0.1–11 NTU), 0.1 NTU (11–110 NTU), 1 NTU (110–1000 NTU) |
| Accuracy | ±2% of reading |
| Light Source | 850 nm Near-Infrared LED |
| Optical Geometry | ISO 7027-compliant 90° scattered-light detection |
| Compliance | Meets ISO 7027, ASTM D6508, and EPA Method 180.1 requirements |
| Brand | Rikorika |
|---|---|
| Origin | Japan |
| Model | UV-700W |
| Instrument Type | Online Analyzer |
| Measurement Principle | Ultraviolet Absorption Spectrophotometry |
| Wavelength | 255 nm (UV) |
| Measurement Range | 0–200 mg/L COD (as KMnO₄ method equivalent) |
| Accuracy | ±2% of full scale |
| Repeatability | ≤2% RSD |
| Detection Limit | 1 mg/L COD |
| Measurement Interval | Continuous monitoring (24/7) |
| Optical Path Length | 10 mm |
| Display Resolution | 0.001 Abs/cm (UV absorbance), 1 mg/L (COD) |
| Output Signal | Isolated DC 4–20 mA (≤550 Ω load) |
| Enclosure Rating | IP65 |
| Operating Temperature | −5°C to +40°C (indoor, shaded installation) |
| Weight | ~2.5 kg (with sunshade cover) |
| Brand | Rikuri Chemical |
|---|---|
| Origin | Japan |
| Model | F-10Z |
| Measurement Principle | Solid-State Lanthanum Fluoride (LaF₃) Crystal Membrane Ion-Selective Electrode (ISE) |
| Range | 0–1999 mg/L F⁻ |
| mV Output Range | −1000 to +1000 mV |
| Resolution | 0.1 mg/L (0.1–99.9 mg/L), 1 mg/L (100–1999 mg/L) |
| Accuracy | ±5% of Full Scale (FS) |
| Display | 3½-digit LCD |
| Temperature Compensation | Automatic (NTC thermistor integrated) |
| Response Time (t₉₀) | ≤60 s |
| Ingress Protection | IP67 |
| Power Supply | DC 4.5 V (3 × AA alkaline batteries) |
| Dimensions (W×H×D) | 70 × 36 × 170 mm |
| Weight | Approx. 290 g (instrument only) |
| Brand | Rikuri |
|---|---|
| Origin | Japan |
| Model | CuNi-5Z |
| Instrument Type | Portable |
| Detection Principle | Photometric (Absorbance-based) |
| Target Analytes | Cu²⁺, Ni²⁺ |
| Measurement Range | Cu: 0.0–80.0 g/L |
| CuSO₄ | 0.0–300 g/L |
| Ni | 0.0–199.9 g/L |
| Absorbance | 0.000–1.999 AU |
| Temperature | 0.0–50.0 °C |
| Accuracy | ±2% FS |
| Resolution | 0.1 g/L (for metal ions) |
| Response Time | 1 s |
| Operating Environment | −5–45 °C, ≤85% RH |
| Power Supply | 3× AAA alkaline batteries (LR03) |
| Sensor Wetted Materials | PPS, PFA, Fluoroelastomer |
| Cable Length | 2 m |
| Brand | Rikuri |
|---|---|
| Origin | Japan |
| Model | NI-502 |
| Instrument Type | Online Multi-Ion Analyzer |
| Measurement Principle | Absorption Photometry (Visible Spectrophotometric Detection at Characteristic Wavelength) |
| Measurement Range | 0–199.9 g/L (High Range) / 0.00–19.99 g/L (Low Range) |
| Detection Limit | 1 g/L |
| Resolution | 0.1 g/L (High Range), 0.01 g/L (Low Range) |
| Accuracy | ±2% FS |
| Response Time | ≤1 s |
| Output Signal | Isolated 4–20 mA DC (3-Stage Range Selection) |
| Alarm Outputs | Dual SPDT Dry Contacts (AC 200 V, 1 A resistive load max) |
| Operating Environment | 0–40 °C, ≤85% RH |
| Power Supply | AC 85–240 V, 50/60 Hz |
| Sensor Options | High-Temperature Flow-Cell Sensor (for plating bath immersion) or Ambient-Temperature Immersion Probe |
| Compliance | Designed for continuous industrial process monitoring in electroplating and semiconductor wet processing lines |
| Brand | Rinntech |
|---|---|
| Origin | Germany |
| Model | LIGNOSTATION |
| Radiation Source | High-Frequency Electromagnetic Sensor (Non-Ionizing) |
| Max Sample Length | 500 mm |
| Spatial Resolution | ≤ 20 µm |
| Imaging Modality | Dual-Mode (Electromagnetic Density Scanning + Optical Micro-Photography) |
| Compliance | CE, RoHS, ISO/IEC 17025-compatible workflow support |
| Preprocessing Integration | Integrated surface trimming and polishing capability |
| Brand | Rivertrace |
|---|---|
| Origin | United Kingdom |
| Model | CW Series |
| Measurement Range | 0–99 ppm |
| Accuracy | ±5 ppm |
| Display | Dual-line 7-segment LED |
| Alarm Setpoints | Adjustable (1–98 ppm) |
| Alarm Delay | Alarm 1: 0–60 s |
| Alarm 2 | 10–240 s |
| Alarm Output | 8 A @ 240 V (inductive) |
| Analog Outputs | 0–20 mA / 4–20 mA (min. load 820 Ω) |
| Ambient Temperature | 1–50 °C |
| Relative Humidity | ≤90% RH (up to +55 °C) |
| Sample Temperature | 1–50 °C |
| Sample Flow Rate | 0.1–2 L/min |
| Sample Pressure | 0.1–10 bar |
| Dimensions (W×D×H) | 215 × 242 × 73 mm |
| Weight | 2.25 kg |
| Power Supply | 230 V/50 Hz or 24 V AC |
| Power Consumption | 10 VA |
| Electrical Safety | EN 61010-1 / IEC 61000-6-4 / IEC 61000-6-2 |
| Certification | Germanischer Lloyd (GL) Type Approved |
| Optical Components | High-temperature resistant fused silica windows & fluorosilicone seals |
| Wetted Materials | Optional 316 stainless steel probe, flow cell, and sample chamber |
| Auto-cleaning | Integrated ultrasonic or mechanical cleaning module (configurable) |
| Brand | Rivertrace |
|---|---|
| Origin | United Kingdom |
| Model | Smart 50M |
| Measurement Range | 0–10 ppm (large cell) / 0–200 ppm (medium cell) |
| Accuracy | ±0.15 ppm (large cell) / ±2 ppm (medium cell) |
| Display Resolution | 0.1 ppm |
| Alarm Setpoints | Adjustable (1–10 ppm or 10–200 ppm per cell) |
| Alarm Delay | 1–15 s (Alarm 1), 1–600 s (Alarm 2) with disable option |
| Output Signal | 4–20 mA |
| Sample Temperature | +1 to +90 °C |
| Sample Flow Rate | 0.3–3 L/min |
| Sample Pressure | 0.1–10 bar |
| Ambient Operating Temperature | +1 to +50 °C |
| Ambient Humidity | ≤80 % RH, non-condensing |
| Enclosure Rating | IP55 |
| Power Supply | 230 VAC, 50 Hz, 15 VA |
| Dimensions (W×D×H) | 500 × 360 × 150 mm |
| Weight | 15 kg |
| Certifications | Germanischer Lloyd (GL) |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | RJ-3 |
| Price | USD 700 (approx.) |
| Instrument Type | Field Strength Meter / Dosimetry Rate Meter |
| Frequency Range | 20–200 MHz |
| Measurement Range | 0–450 V/m (3-range switchable: 0–30 V/m, 30–150 V/m, 50–450 V/m) |
| Overall Measurement Uncertainty | ≤ ±30% |
| Operating Temperature | −10 °C to +40 °C |
| Relative Humidity | ≤ 80% RH |
| Power Supply | Two 6 V F22 alkaline stacked batteries |
| Form Factor | Portable |
| Instrument Dimensions | 170 mm × 100 mm × 45 mm |
| Packaging Dimensions | 450 mm × 370 mm × 150 mm |
| Weight | ~3 kg |
| Frequency Range | 30 Hz–2000 Hz |
|---|---|
| Electric Field Range | 0–20,000 V/m |
| Measurement Accuracy | ≤ ±1.5 dB |
| Operating Temperature | −10 °C to +40 °C |
| Relative Humidity | ≤ 80 % RH |
| Power Supply | Rechargeable 8.4 V battery or 9 V alkaline (6F22) |
| Form Factor | Portable |
| Weight | 550 g |
| Brand | Lihero |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Roadside Mobile Source Monitoring Station |
| Pricing | Available Upon Request |
| Brand | ROCKER |
|---|---|
| Origin | Taiwan |
| Model | CD200 |
| Instrument Type | Portable |
| Measurement Principle | UV Absorption Spectrophotometry |
| Measurement Ranges | 10–150 mg/L, 100–1500 mg/L, 1000–15000 mg/L |
| Display | Backlit LCD |
| Light Source | LED |
| Measurement Time | 3 seconds |
| Data Storage Capacity | 100 records |
| Power Supply | DC 9 V battery or external AC adapter |
| Weight | 0.5 kg |
| Dimensions | 23 × 13 × 9 cm |
| Regulatory Compliance | CE Marked |
| Compatible Reagents | Hach, Lovibond, CHEMetrics, Hanna, Merck |