| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHGGMS4000 |
| Detection Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Target Gases & Measurement Ranges | CO₂ (0–5000 ppm), CH₄ (0–100 ppm), N₂O (0–50 ppm) |
| Compliance | GB/T 38997–2020, HJ 1013–2018, ISO 14064-1, ASTM D6522 |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | XHN2000B |
| Detection Principle | Gas-Phase Chemiluminescence |
| Measured Species | NO, NO₂ (via catalytic conversion), NOₓ (sum) |
| Compliance | Certified by China Environmental Monitoring Instrument Quality Supervision & Inspection Center |
| Brand | SAIL HERO |
|---|---|
| Model | XHN2100B |
| Measurement Principle | Chemiluminescence Detection (CLD) with NO–O₃ Reaction |
| Target Analyte | NH₃ (derived via TNₓ–NOₓ differential) |
| Compliance | Designed for continuous ambient air quality monitoring per China’s HJ 654-2013 and compatible with EPA Method 7010 / ISO 11088:2021 frameworks |
| Output Options | RS232, RS485, 0–5 V analog, 4–20 mA current loop (optional) |
| Environmental Compensation | Integrated temperature & pressure sensors with real-time correction |
| Calibration | Manual or remote zero/span calibration capability |
| Display & Interface | Touchscreen GUI with multilingual support (default Chinese, English firmware-ready) |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Operating Temperature | 0–40 °C |
| Enclosure Rating | IP54 |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | XHOZ2000B |
| Pollutant Measured | O₃ |
| Measurement Principle | UV Absorption at 254 nm |
| Calibration | Manual and Remote Zero/Span Calibration |
| Optical Path Material | PTFE (Teflon) |
| Certification | CEPAA Environmental Product Certification |
| Verification | CMA-Accredited Testing Report from Ministry of Ecology and Environment Environmental Monitoring Instrument Quality Supervision & Inspection Center |
| Temperature Control | Closed-Loop Thermostatic Regulation of UV Lamp |
| Detection Technology | Dual-Beam Ratio Measurement |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHPM2000E |
| Measurement Principle | Beta-ray attenuation with dynamic heating system |
| Measured Parameter | PM₂.₅ mass concentration |
| Measurement Range | 0–0.1, 0.2, 1, 2, 5, or 10 mg/m³ (user-selectable full-scale ranges) |
| Measurement Cycle | 30 min to 60 min (configurable) |
| Sampling Flow Rate | 16.7 L/min ±2.5% |
| Limit of Detection (24-hr avg) | 5 µg/m³ |
| Compliance | Certified per Chinese EPA requirements for radioactive source management, HJ 653–2013, HJ 93–2013, and GB/T 34672–2017 |
| Regulatory Approvals | CEPAA Environmental Product Certification, CNEMC Calibration & Performance Verification Report, CIPAC Technical Appraisal Certificate for PM₂.₅ Separation Inlet |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | XHPM2000E |
| Measurement Method | Beta-ray Absorption (β-ray) with Dynamic Heating System |
| Measured Parameter | PM₁₀ |
| Measurement Range | 0–0.1, 0.2, 1, 2, 5, or 10 mg/m³ (user-selectable full-scale) |
| Sampling Interval | 30 min to 1 h (configurable) |
| Sample Flow Rate | 16.7 L/min ±2.5% |
| Limit of Detection (24-h avg) | 1 µg/m³ |
| Compliance | EPA EQPM-0805-154 (equivalent), HJ 653–2013, HJ 93–2013, HJ 978–2018 |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | XHPM2001 |
| Measurement Principle | Beta-ray Absorption (β-ray) |
| Measured Parameters | TSP, PM10, PM2.5, PM1 |
| Sampling Flow Rate | 16.7 L/min |
| Display | 7-inch High-Brightness TFT Touchscreen with Windows-based GUI |
| Calibration Method | Standardized Calibration Foil |
| Compliance | Certified by China Environmental Monitoring Station (CEMS) for PM10 Portability |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | XHS2100B |
| Measured Pollutant | H₂S |
| Detection Principle | Catalytic Thermal Conversion + UV Fluorescence (SO₂) |
| Conversion Efficiency | >96% |
| Zero/Span Calibration | Manual or Remote Automated |
| Data Storage | Internal Dynamic Memory ≥1 Year (1-Minute Averages) |
| Environmental Compensation | Automatic Temperature & Pressure Correction |
| Interference Mitigation | Integrated Hydrocarbon Scrubber (PAH Removal) |
| Communication Interfaces | RS232, RS485, 0–5 V Analog Output, 4–20 mA Current Loop (Optional) |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | XHTN-90 |
| Measurement Parameter | Total Nitrogen |
| Instrument Type | Online Analyzer |
| Measurement Principle | Spectrophotometry (Alkaline Potassium Persulfate Digestion + UV Absorption at 220 nm) |
| Measurement Range | 0–50 mg/L (expandable) |
| Accuracy | ±3.0% FS |
| Detection Limit | 0.1 mg/L |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | XHUV-90A |
| Measurement Wavelength | 254 nm (UV) + Visible Reference |
| Compensation | Temperature & Visible-Light Baseline Correction |
| Measurement Ranges | 0–200 m⁻¹ |
| Repeatability | ±1.5% FS |
| Zero Drift | ±1.5% FS |
| Span Drift | ±1.5% FS |
| Linearity | ±4% FS |
| Power Supply | AC 220 V, 50 Hz |
| Output Interfaces | RS232/RS485 digital communication |
| Display | Touchscreen LCD with Chinese UI |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHVOC1000 |
| Pricing | Available upon Request |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Instrument Type | Continuous Online Analyzer |
| Measurement Range | Non-Methane Hydrocarbons (NMHC): 0–5 µmol/mol (configurable) |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHVOC40 |
| Pricing | Available Upon Request |
| Brand | SAIL HERO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | XHVOC6000 |
| Detection Principle | Gas Chromatography-Mass Spectrometry (GC-MS) |
| Instrument Type | Online Analyzer |
| Typical Configuration | Multi-component VOC Monitoring System |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XHZ3000 |
| Zero Air Purity | SO₂ ≤ 0.1 nmol/mol |
| Output Pressure Range | 0.06–0.42 MPa |
| Dew Point | < −20 °C |
| Brand | Sanpu |
|---|---|
| Model | FD216 |
| Origin | Beijing, China |
| Manufacturer | Sanpu Instrument Co., Ltd. |
| Detection Principle | ZnS(Ag) Scintillation + Photomultiplier Tube (PMT) |
| Measurement Modes | Active Pump-Driven Air/Solid/Water Sampling |
| Sensitivity | ≥0.68 cpm/(Bq·m⁻³) |
| Background Count Rate | ≤0.3 cpm |
| Radon-in-Air Range | 3–100,000 Bq/m³ |
| Soil Radon Range | 300–300,000 Bq/m³ |
| Radon Exhalation Rate Range | 0.001–10.000 Bq/(m²·s) |
| Water Radon Range | 0.003–100 Bq/L |
| Repeatability Error | ≤5% (at 2000 Bq/m³, 65% RH, 25°C) |
| 8-h Drift | ≤10% |
| Power Supply | Rechargeable Li-ion battery (30 h continuous operation) or AC adapter |
| Operating Temp | −10°C to +40°C |
| Max. Relative Humidity | ≤90% at +40°C |
| Data Storage | 2000 records |
| Display | LCD |
| Interface | USB + Bluetooth printing |
| Dimensions | 330 × 210 × 170 mm |
| Weight | 5 kg (main unit) |
| Calibration & Traceability | Certified by National Institute of Metrology (NIM), China |
| Brand | Santiyiqi |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ST-T2 |
| Detection Range | 3.6 kg (instrument weight) |
| Operating System | Android (ARM Cortex-A7, RK3288, Quad-core, 1.88 GHz) |
| Display | 7-inch TFT capacitive touchscreen (1024 × 600) |
| Optical System | 4-channel fixed-wavelength cold LED光源 (680±2 nm red, 420±2 nm blue, 510±2 nm green, 590±4 nm orange) |
| Photometric Accuracy | ±0.001 Abs (2 h drift), repeatability ≤0.03% (K₂Cr₂O₇) |
| pH Measurement | 1–14, resolution 0.01, accuracy ±0.1 |
| EC/Soil Salinity | 0.01–1.00%, relative error ±5% |
| Moisture Measurement | 0–100% w/w, error <0.5% |
| Data Connectivity | Wi-Fi, 4G, GPRS, Ethernet, USB |
| Environmental Rating | IP65 |
| Battery | Rechargeable Li-ion, >10 h continuous operation |
| Dimensions | 42 × 31 × 15 cm |
| Net Weight | 3.6 kg |
| Brand | Santiyiqi |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ST-TN2 |
| Price | USD 4,200 (FOB) |
| Brand | Santiyiqi |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ST-WSYPF |
| Price | USD 820 (FOB) |
| Brand | Sanxin |
|---|---|
| Model | MP516 |
| Measurement Principle | Polarographic (Clark-type) Electrochemical Detection |
| DO Range | 0–40.00 mg/L (ppm) / 0–200.0 % saturation |
| Accuracy | ±0.10 mg/L |
| Temp. Compensation | 0–45 °C (auto) |
| Salinity Compensation | 0–45 ppt (auto) |
| Barometric Compensation | 80–105 kPa (integrated sensor) |
| Calibration Modes | Water-saturated air & air-saturated water |
| Temp. Range (sensor) | 0–45 °C |
| Temp. Accuracy | ±0.4 °C |
| Data Storage | 600 sets |
| Interface | RS232 |
| Power | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| IP Rating | IP54 |
| Electrode Type | Replaceable DO500 polarographic sensor with DO503 membrane cap and DO502 electrolyte solution |
| Includes | 901 Smart Stirrer, 602 Universal Electrode Holder, Cathode Polishing Paper |
| Brand | Sanxin Peirui |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Sodium Ion Analyzer |
| Measurement Range (Meter) | 0.00–9.00 pNa |
| (with配套 electrode system) | 1.00–7.00 pNa |
| Accuracy (Meter) | ±0.01 pX |
| (System) | ±0.02 pX |
| Temperature Range | −10 °C to 110 °C |
| Detection Limit (Static) | ≥2 ppb Na⁺ |
| (Dynamic) | ≥0.2 ppb Na⁺ |
| Units | pNa, mol/L, mg/L, ppm |
| Temperature Compensation | 0–50 °C |
| mV Range | ±1999.9 mV |
| Resolution | 0.1 mV |
| Accuracy | ±0.1% FS |
| Temp Accuracy | ±0.5 °C (5–60 °C), ±1.0 °C (elsewhere) |
| Data Storage | 600 entries |
| Interface | RS232 |
| Power | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| IP Rating | IP54 |
| Compliance | GLP-compliant architecture, supports audit-ready data logging |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Ion Measured | Fluoride (F⁻) |
| Measurement Range (Meter) | 0.00–9.00 pF |
| Measurement Range (with Electrode Pair) | 1.00–7.00 pF |
| Accuracy (Meter) | ±0.01 pF |
| Accuracy (Electrode System) | ±0.02 pF |
| Temperature Range | −10 °C to 110 °C |
| Temperature Compensation Range | 0 °C to 50 °C |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1% FS |
| Temperature Accuracy | ±0.5 °C (5–60 °C), ±1.0 °C (other ranges) |
| Data Storage | 600 sets |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| IP Rating | IP54 |
| Compliance | GLP-compliant design, dust- and splash-resistant enclosure |
| Brand | Sanxin |
|---|---|
| Model | MP521 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Water Quality Analyzer |
| Measuring Parameters | pH, mV, Conductivity (0.00 μS/cm – 200.0 mS/cm), Resistivity, TDS, Salinity |
| pH Range | −1.99 to 19.99 pH |
| pH Accuracy | ±0.01 pH |
| Temperature Compensation (pH) | 0–100 °C |
| mV Range | ±1999 mV |
| mV Accuracy | ±0.1% FS |
| Conductivity Range | 0–200.0 mS/cm (5-range auto-scaling) |
| Conductivity Accuracy | ±1.0% FS |
| Temp. Range | −10 to 110 °C |
| Temp. Accuracy | ±0.5 °C |
| Data Storage | 900 sets |
| Interface | RS232 |
| Power | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| IP Rating | IP54 |
| Compliance | GLP-compliant design, supports audit-ready data logging |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Model | MP522 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameters | pH, mV, ORP, Conductivity, Resistivity, TDS, Salinity |
| pH Range | −2.000 to 19.999 |
| pH Accuracy | ±0.002 |
| Temperature Compensation (pH) | 0–100 °C |
| mV Range | ±1999.9 mV |
| mV Accuracy | ±0.03% FS |
| Conductivity Range | 0–2000 mS/cm (6 ranges, K=1 and K=10 electrodes supported) |
| Conductivity Accuracy | ±0.5% FS |
| Temperature Range | −10 to 110 °C |
| Temp. Accuracy | ±0.4 °C |
| Resistivity | 0–100 MΩ·cm |
| TDS | 0–100 g/L |
| Salinity | 0–100 ppt |
| Data Storage | 900 sets |
| Interface | RS232 |
| Power | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| IP Rating | IP54 |
| GLP Compliance | Yes |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Model | MP523-01 |
| Instrument Type | Benchtop |
| Measurement Range | pH: −2.000–19.999 |
| Ion Concentration | 0.00–14.00 pX (equivalent to 0.01 mg/L–1000 mg/L depending on ion valence and selectivity) |
| Temperature | −10–110 °C |
| Detection Limit | 0.01 mg/L (typical for monovalent ions) |
| Response Time | ≤60 s (for ion concentration stabilization) |
| Accuracy | pH: ±0.002 pH |
| Ion | ±0.5% of reading (monovalent), ±1.0% of reading (divalent) |
| Temperature | ±0.4 °C |
| Temperature Compensation | Automatic, 0–100 °C (pH), 0–60 °C (ion) |
| Data Storage | 900 sets |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions & Weight | 160 × 190 × 70 mm / 880 g |
| IP Rating | IP54 |
| Compliance | GLP-compliant architecture with audit-trail-capable data logging |
| Brand | Sanxin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Principle | Electrochemical Potentiometry |
| Measurable Parameters | pH and Ion Activity/Concentration |
| pH Range | −2.000 to 19.999 pH |
| pH Accuracy | ±0.002 pH |
| Temperature Compensation (pH) | 0–100 °C |
| mV Range | ±1999.9 mV |
| mV Accuracy | ±0.03 % FS |
| Ion Range | 0.00–14.00 pX (with unit options: pX, mol/L, mg/L, ppm) |
| Ion Accuracy | ±0.5 % reading (monovalent), ±1.0 % reading (divalent) |
| Temp. Compensation (Ion) | 0–60 °C |
| Temperature Range | −10 to 110 °C |
| Temp. Accuracy | ±0.4 °C |
| Data Storage | 900 sets |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| IP Rating | IP54 |
| GLP Compliance | Yes |
| Brand | Sanxin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Model | MP523-02 |
| Ion Type | Sodium |
| Measurement Range (pNa) | 0.00–9.00 pNa (electrometer) |
| Detection Limit | ≥0.2 ppb (dynamic mode), ≥2 ppb (static mode) |
| Accuracy | ±0.01 pNa |
| Temperature Compensation | 0–50 °C |
| Data Storage | 600 sets |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| IP Rating | IP54 |
| Compliance | GLP-compliant architecture, supports audit-ready data logging |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic Lab-Based Water Quality Analyzer |
| Model | MP523-05 |
| Detection Principle | Electrochemical Potentiometry |
| Measured Parameters | pH and Chloride Ion (Cl⁻) Activity/Concentration |
| pH Range | −1.999 to 19.999 |
| pCl Range (Meter) | 0.00 to 14.00 pX (pCl scale) |
| Electrode-Specific Range | 1.0 to 4.3 pCl |
| Display Units for Cl⁻ | pCl, mol/L, mg/L, ppm |
| pH Accuracy | ±0.002 pH |
| pCl Accuracy | ±0.04 pCl |
| Temperature Compensation | pH: 0–100 °C |
| Cl⁻ | 0–50 °C |
| mV Range | ±1999.9 mV |
| Resolution | 0.1 mV |
| Accuracy | ±0.1% FS |
| Temperature Measurement | −10 to 110 °C |
| Resolution | 0.1 °C |
| Accuracy | ±0.5 °C (5–60 °C), ±1.0 °C (elsewhere) |
| Data Storage | 600 sets |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions & Weight | 160 × 190 × 70 mm / 880 g |
| Brand | Sanxin |
|---|---|
| Model | MP525 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Category | Laboratory Water Quality Analyzer |
| pH Range | −2.000 to 19.999 |
| pH Accuracy | ±0.002 pH |
| mV Range | ±1999.9 mV |
| mV Accuracy | ±0.03% FS |
| DO Range | 0–40.00 mg/L (ppm) / 0–200.0% saturation |
| DO Accuracy | ±0.10 mg/L |
| Temperature Range | −10 to 110 °C |
| Temp Accuracy | ±0.4 °C |
| Auto Compensation | Temperature (0–100 °C for pH |
| Calibration Modes | Air-saturated water, Water-saturated air |
| Data Storage | 900 sets |
| Interface | RS232 |
| Power | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| IP Rating | IP54 |
| GLP Compliance | Yes |
| Brand | SANXIN |
|---|---|
| Model | MP526 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Measurement Range (Conductivity) | 0–2000 mS/cm (6-range auto-scaling) |
| Measurement Range (DO) | 0–40.00 mg/L and 0–200.0 % saturation |
| Accuracy (Conductivity) | ±0.5% FS |
| Accuracy (DO) | ±0.10 mg/L |
| Temperature Range | −10 to 110 °C |
| Temp. Compensation (Conductivity) | 0–50 °C |
| Temp. Compensation (DO) | 0–45 °C |
| Salinity Compensation (DO) | 0–45 ppt |
| Barometric Compensation (DO) | 80–105 kPa |
| Data Storage | 900 sets |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions & Weight | 160 × 190 × 70 mm / 880 g |
| IP Rating | IP54 |
| GLP Compliance | Yes |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | PC9500 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Principle | Electrochemical Method |
| Measured Parameters | pH, mV, Conductivity, TDS, Salinity, Resistivity, Temperature |
| Measurement Ranges | pH: −2.000–20.000 |
| mV | ±2000.0 |
| Conductivity | 0.00 μS/cm–2000 mS/cm |
| TDS | 0.00 mg/L–1000 g/L |
| Salinity | 0.00–100 ppt |
| Resistivity | 0.00 Ω·cm–100 MΩ·cm |