Environmental Monitoring Instruments
Filter
Showing 6601–6630 of 9029 results
| Brand | SciTech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GC2002-N/PDHID |
| Detection Capability | ppb-level trace impurities in ultra-high-purity bulk and specialty gases (e.g., H₂, N₂, O₂, Ar, He, Ne, Kr, Xe, SiH₄, PH₃, B₂H₆, NF₃, Cl₂, F₂, HCl, HF) |
| Detector | VICI Pulsed Discharge Helium Ionization Detector (PDHID) with integrated high-voltage pulse generator and helium purifier |
| Valve System | Four-valve, multi-column configuration with carrier gas purge protection |
| Column Configuration | Separated temperature-controlled pre-column and analytical column |
| Sample Introduction | Pre-flush injection system with low dead-volume sampling loop |
| Communication Interface | Ethernet (10/100 Mbps), PC remote control, embedded chromatography workstation |
| Brand | SDL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | MODEL 9001 |
| Application | Real-time in-situ chlorophyll a monitoring in surface water bodies |
| Brand | SDL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MODEL 9880 |
| Instrument Type | Online Analyzer |
| Biological Sensing Element | Electroactive Bacteria (Exoelectrogens) |
| Repeatability | ±30% |
| Detection Principle | Microbial Fuel Cell (MFC)-Based Current Response to Toxic/Nutrient Perturbations |
| Communication Interfaces | RS485, Modbus TCP, 4–20 mA Output, Optional 3G/4G LTE |
| Display Interface | Chinese-Language Touchscreen HMI |
| Compliance Framework | Designed for ISO 11348-3 and ASTM D5664 alignment in operational context |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SDT-XP-3160 |
| Pricing | Upon Request |
| Detection Principle | Catalytic Bead (Pellistor) Combustion |
| Detection Range | 0–5000 ppm or 0–1 vol% |
| Accuracy | ±5% FS (H-range), ±10% FS (L-range) |
| Alarm Setpoints | 250 ppm / 500 ppm |
| Display | Backlit LCD with Digital + Bar Graph |
| Power | 4× AA Alkaline Batteries or Optional Ni-Cd Rechargeable Pack |
| Operating Temperature | −20 °C to +50 °C |
| Explosion Protection | Exibd IIB T3 |
| Dimensions | 82 × 162 × 36 mm |
| Weight | 450 g (battery-free) |
| Flow Self-Check Function | Yes |
| Auto-Ranging | Yes |
| Data Logging | Built-in (optional download via USB) |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Ranger EXP |
| Price Range | USD 1,400–2,800 (est.) |
| Instrument Class | Dose Rate / Survey Meter |
| Form Factor | Portable |
| Measurable Radiation Types | α, β, γ, and X-rays |
| Dose Rate Range | 0.001–1,000 µSv/hr |
| Sensitivity | 3,340 CPM per mR/hr (referenced to Cs-137) |
| Detector | External LND 7317 halogen-quenched Geiger-Müller tube, 1.77″ (45 mm) active diameter, mica window density 1.4–2.0 mg/cm² |
| Display | Backlit 4-digit LCD, 3-second update interval (adaptive averaging) |
| Accuracy | ±10% to ±15% |
| Alarm Thresholds | Adjustable 0.001–50 mR/hr or 1–160,000 CPM |
| Audio/Visual Alert | 70 dB @ 1 m, red LED flash per count |
| Data Interface | Mini-USB (data logging & bus-powered operation) |
| Power | Two AA batteries |
| Operating Temperature | 0–50 °C |
| Dimensions | 140 × 68 × 33 mm |
| Weight | 220 g (body only) |
| Compliance | CE, NIM (China National Institute of Metrology) certified |
| Preloaded Nuclides | S-35, Sr-90/Y-90, Cs-137, P-32, C-14, I-131, Co-60, α-emitters |
| Brand | Sea-Bird Scientific |
|---|---|
| Origin | USA |
| Manufacturer | WET Labs (designed and manufactured) |
| Model | ECO Series |
| Instrument Type | Submersible Optical Sensor Platform |
| Deployment Modes | Profiling, Moored, Buoy-Mounted, Handheld (via optional interface) |
| Compliance | IP68 rated, ASTM D3921-22 (for turbidity), ISO 10264-2 (for chlorophyll-a fluorescence calibration traceability), GLP-compliant data logging |
| Brand | Sea-Bird Scientific |
|---|---|
| Origin | Imported |
| Model | ECO Series |
| Optical Excitation/Emission Wavelengths | Chl-a 470/695 nm, CDOM 370/460 nm, Fluorescein 470/530 nm, Rhodamine WT 540/570 nm, Phycoerythrin 540/570 nm, Phycocyanin 630/680 nm |
| Backscatter Wavelengths | 470, 532, 650 nm |
| Chl-a Sensitivity | 0.02 µg/L |
| Chl-a Range | 0–125 µg/L |
| Turbidity Accuracy | ±0.003 NTU (0–10 NTU) to ±0.25 NTU (0–1000 NTU) |
| Backscatter Sensitivity | 0.003 m⁻¹ |
| Backscatter Range | ~0.0024–5 m⁻¹ |
| Digital Resolution | 12–14 bit |
| RS-232 Baud Rate | 19200 |
| Analog Output | 0–5 V |
| Operating Depth | 600 m |
| Temperature Range | 0–30 °C |
| Power Supply | 7–15 VDC |
| Typical Current Draw | 50–60 mA |
| Sleep Current | 140 µA |
| Housing Material | Acetal Copolymer |
| Connector | MCBH6MP |
| Optional Features | Anti-fouling Copper Brush, Internal Battery, Onboard Memory (up to 108,000 samples), Integrated T/P Sensor |
| Brand | Sea-Bird Scientific |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | LOBO |
| Pricing | Upon Request |
| [Origin | Norway |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SD204 |
| Instrument Type | Portable/Handheld CTD Profiler |
| Measured Parameters | Conductivity, Salinity, Temperature, Depth (Pressure), Sound Velocity (Derived Density) |
| Optional Sensors | Dissolved Oxygen, Turbidity, Fluorescence (Chlorophyll-a, CDOM) |
| Max Operating Depth | 6000 m |
| Memory Capacity | 56,000 Data Sets |
| Power | Dual 3.6 V Li-ion Batteries (1-Year Typical Runtime) |
| Housing Material | Vacuum-Cast Polyurethane & Titanium Alloy |
| Communication | RS-232 (ASCII, 1200–9600 bps) |
| Software | SD200W for Windows] |
| Brand | Sea-Bird Scientific |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | SUNA V2 |
| Optical Path Length Options | 5 mm or 10 mm |
| Detection Range | 0.5–4000 µM NO₃⁻ (0.007–56 mg/L N) |
| Accuracy | ±2 µM (10 mm) or ±4 µM (5 mm), or ±10% of reading, whichever is greater |
| Short-Term Precision (3σ) | 0.3 µM (T-S-corrected freshwater/seawater) |
| Long-Term Drift | ≤0.3 µM/h (T-S-corrected) |
| Turbidity Tolerance | 625 NTU (10 mm), 1250 NTU (5 mm) |
| Wavelength Range | 190–370 nm |
| Lamp Lifetime | 900 h |
| Operating Voltage | 8–18 VDC (8–15 VDC with biofouling brush) |
| Power Consumption | 7.5 W at 12 VDC (0.625 A) |
| Housing Material | Polyoxymethylene (POM) and Titanium Alloy |
| Depth Rating | 500 m (standard) |
| Weight | 2.5 kg (standard) |
| Calibration Options | Freshwater and Seawater Modes |
| Data Interface | USB (PC/Mac compatible) |
| Software | SUNACom v3.x (Windows/macOS) |
| Brand | Sea-Bird Scientific |
|---|---|
| Manufacturer | Satlantic (Canada) |
| Model | SUNA V2 |
| Detection Principle | In-Situ Ultraviolet Spectroscopy (ISUS) |
| Measurement Target | Nitrate-N (NO₃⁻) |
| Form Factor | Submersible, Online-Ready |
| Path Length Options | 5 mm or 10 mm |
| Detection Range | 0.5–4000 µM (0.007–56 mg/L as N) |
| Accuracy | ±2 µM (10 mm) / ±4 µM (5 mm) or ±10% |
| Short-Term Precision (3σ) | 0.3 µM (freshwater/seawater T-S corrected) |
| Long-Term Drift | ≤0.3 µM/h (T-S corrected) |
| Turbidity Tolerance | 625 NTU (10 mm), 1250 NTU (5 mm) |
| Wavelength Range | 190–370 nm |
| Lamp Lifetime | 900 h |
| Operating Voltage | 8–18 VDC (8–15 VDC with biowiper) |
| Power Consumption | 7.5 W (0.625 A @ 12 V) |
| Housing Material | Titanium / Acetal |
| Maximum Depth Rating | 500 m (100 m with biowiper) |
| Weight | 2.5 kg (3.1 kg with biowiper) |
| Brand | Sea-Bird Scientific |
|---|---|
| Origin | USA |
| Model | WQM |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | CTD (Conductivity, Temperature, Depth), Dissolved Oxygen (DO), Fluorescence (Chlorophyll-a), Turbidity (FLNTU) |
| Optional Parameters | CDOM, PAR, Phycocyanin, Phycoerythrin, pH |
| Conductivity Range | 0–9 S/m |
| Conductivity Accuracy | ±0.003 mS/cm |
| Conductivity Resolution | 0.0005 S/m |
| Temperature Range | −5 to 35 °C |
| Temperature Accuracy | ±0.002 °C |
| Temperature Resolution | 0.001 °C |
| Depth Range | 0–100 m or 0–200 m |
| Depth Accuracy | ±0.1% FS |
| DO Range | 0–120% saturation |
| DO Accuracy | ±2% saturation |
| DO Resolution | ±0.035% saturation |
| Chlorophyll Fluorescence Range | 0–30 µg/L |
| Fluorescence Accuracy | ±0.2% FS |
| Excitation/Emission | 470/695 nm |
| Turbidity Range | 0–25 NTU |
| Turbidity Accuracy | ±0.1 FS NTU |
| Detection Wavelength | 700 nm |
| Biofouling Mitigation | Pump-controlled flow, Copper anti-fouling panel, Light-shielded sample chamber, Rotating copper brush for optical surface cleaning, EPA-certified conductive cell anti-fouling ring, Bleach Injection System (BLIS) for DO and CTD channel protection |
| Brand | Sea-Bird Scientific |
|---|---|
| Manufacturer Origin | USA |
| Model | WQMX |
| Sensor Integration | CTD + FLNTU + DO + CDOM + Optional PAR/Phycocyanin/Phycoerythrin/pH |
| Depth Rating | 200 m |
| Power Input | 9–16 V DC |
| Communication | RS-232 |
| Sampling Rate | 1 Hz |
| Weight (air/water) | 6.25 kg / 1.7 kg |
| Biofouling Resistance | 3–6 months continuous deployment |
| Compliance | ASTM D888, ISO 5814, USP <643>, EPA Method 4500-O, GLP/GMP-ready data logging |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Seafloor-Based Monitoring System |
| Pricing | Available Upon Request |
| Brand | SEAL |
|---|---|
| Origin | USA |
| Model | AQ2 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Parameters | Ammonia-N, Nitrate, Nitrite, Phosphate, Total Nitrogen, Total Phosphorus, Hexavalent Chromium, Alkalinity, Color, Hardness, Chloride, Sulfate, etc. |
| Throughput | Up to 150 samples/hour |
| Reagents | 15 × 43 mL (on-board refrigerated) |
| Sample Capacity | 57 × 2 mL or 100 × 1.2 mL removable trays |
| Reaction Temperature | Precisely controlled at 37 °C |
| Optical System | 7-position interference filter wheel (standard: 405, 480, 505, 520, 578, 660, 880 nm) |
| Calibration | Linear and up to 6th-order polynomial (20 calibration points supported) |
| Data Output | CSV, HTML reports |
| Compliance | CE-marked |
| Power | 110/115 V 60 Hz or 220/240 V 50 Hz |
| Dimensions | 68 × 41 × 55 cm (W × H × D) |
| Weight | 40 kg |
| Brand | SEAL |
|---|---|
| Origin | USA |
| Model | AQ400 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Parameters | COD, Ammonia-N, Nitrate-N, Nitrite-N, Orthophosphate, Hexavalent Chromium, Alkalinity, Color, Hardness |
| Compliance | EPA-Approved Methods |
| Optical Cell | Quartz, 1 cm standard pathlength (optional extended pathlength) |
| Sample/Reagent Capacity | High-throughput carousel configuration |
| Automation Level | Fully unattended operation with onboard cooling/non-cooling reagent positions |
| Detection Principle | UV-Vis Spectrophotometry (Discrete Reaction Kinetics) |
| Software | Method-driven, CFR Part 11-compliant data handling with audit trail |
| Regulatory Alignment | Designed for GLP/GMP and ISO/IEC 17025 environments |
| Brand | SEAL |
|---|---|
| Origin | USA |
| Model | AQ700 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Analytes | Ammonium, Nitrate, Nitrite, Chloride, Orthophosphate, Sulfate, Silicate, Hexavalent Chromium, Fluoride, Total Alkalinity, Total Hardness, Calcium, Magnesium, Iron, Ferrous Iron, Manganese, Aluminum |
| Compliance | ISO 15923-1 & ISO 15923-2 |
| Optical Cell | Quartz, 1 cm pathlength (optional extended pathlength available) |
| Sample Handling | 4 robotic arms, 4 sample trays, programmable sample addition during run |
| Reagent Management | Cooled and uncooled reagent positions, up to 10 working standards per calibration curve |
| Detection Principle | Fixed-position photometric absorbance measurement in static quartz cuvette |
| Reaction Control | Programmable incubation time (seconds to minutes), bubble-free segmented reaction simulation |
| Carryover Prevention | Probe external-wall washing during vertical motion, post-measurement deep-cuvette cleaning |
| Throughput | High-capacity unattended operation (overnight, multi-shift) |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | QuAAtro |
| Instrument Type | Laboratory Continuous Flow Analyzer (CFA) |
| Flow Cell ID | 1 mm |
| Temperature Control | Air-Circulating Thermostatic System (37 °C) |
| Max. Sample Throughput | 120 samples/hour |
| Optical Detection | LED-based Photometer with 24-bit ADC |
| Software | AACE v5.x (Automated Analysis Control Environment) |
| Channel Capacity | Up to 4 independent analytical channels per bench |
| Compliance | ISO 15682, EPA Methods 300.0, 353.2, 365.2, ASTM D5179, D5504 |
| Pumping System | Precision Micro-bore Peristaltic Pump with CrMoV Steel Rollers (±8 µm tolerance), Kel-F® fluidic tubing |
| Brand | Seapoint |
|---|---|
| Model | SCF |
| Origin | USA |
| Depth Rating | 6000 m |
| Excitation Wavelength | 470 nm |
| Emission Wavelength | 685 nm |
| Detection Limit | 0.02 µg/L |
| Output | 0–5.0 VDC |
| Response Time Constant | 0.1 s |
| Power Supply | 8–20 VDC, Avg. 15 mA, Max. 27 mA |
| Operating Temperature | 0–65 °C |
| Housing Material | ABS Plastic with Epoxy Underwater Connector (Push-Type AG-306/206) |
| Sensitivity Ranges | 1× (0.033 V/µg/L, 0–150 µg/L), 3× (0.1 V/µg/L, 0–50 µg/L), 10× (0.33 V/µg/L, 0–15 µg/L), 30× (1.0 V/µg/L, 0–5 µg/L) |
| Temperature Coefficient | <0.2 %/°C |
| Net Weight | 1000 g |
| Sensing Volume | 340 mm³ |
| Compatible With | Standard turbidity and fluorescence sensor interfaces |
| Brand | SEBA |
|---|---|
| Origin | Germany |
| Model | Dipper-TEC |
| Pressure Sensor Type | Ceramic |
| Measurement Principle | Compensated Piezoresistive Transduction |
| Water Level Range | 0–20 m (customizable up to 200 m) |
| Accuracy | ±0.05% FS (e.g., ±1 cm at 20 m range) |
| Resolution | 0.3 mm (0–10 m range) |
| Temperature Range | –5 °C to +50 °C |
| Conductivity Ranges | 0–200 µS/cm, 0–2 mS/cm, 0–20 mS/cm, or 0–200 mS/cm |
| Conductivity Accuracy | ±0.5% |
| Stability | ±0.1% FS/year |
| Data Storage | 1 MB flash memory (~480,000 records) |
| Sampling Interval | 1 min – 45 days |
| Operating Temperature | –20 °C to +70 °C |
| Battery Life | >10 years (60-min interval) |
| Housing Diameter | 22 mm |
| Length | 270 mm |
| Cable Max Length | 1000 m |
| Communication | RS485 (ASCII), optional Bluetooth |
| Enclosure Rating | IP67 (handheld unit) |
| Processor | 16-bit MCU (sensor unit) |
| Display | 240 × 320 TFT touchscreen, 1/4 VGA |
| Power | Rechargeable 3800 mAh NiMH battery (12–30 h operation) |
| Brand | SEBA |
|---|---|
| Country of Origin | Germany |
| Model | Dipper-TEC |
| Sensor Type | Ceramic Piezoresistive Pressure Transducer with Barometric Compensation |
| Water Level Range | 0–20 m (customizable up to 200 m) |
| Water Level Accuracy | ±0.05% FS (±1 cm at 20 m range) |
| Resolution | 0.3 mm (0–10 m range) |
| Long-Term Stability | ±0.1% FS/year |
| Temperature Sensor | PT1000 or NTC, Range: –5 to +50 °C, Accuracy: ±0.1 °C |
| Conductivity Sensor | 4-electrode cell, Ranges: 0–200 µS/cm, 0–2 mS/cm, 0–20 mS/cm, or 0–200 mS/cm, Accuracy: ±0.5% FS |
| Operating Temperature | –20 to +70 °C (sensor), 0 to +50 °C (conductivity cell) |
| Battery Life | >10 years @ 60-min logging interval |
| Memory | 1 MB Flash (≈480,000 data records) |
| Data Logging Interval | 1 min – 45 days |
| Communication | RS485 (ASCII), Optional Bluetooth (via handheld HAD reader) |
| Enclosure Diameter | 22 mm |
| Length | 270 mm |
| Max Cable Length | 1000 m |
| IP Rating | IP68 (sensor), IP67 (HAD reader) |
| Power Supply | Lithium primary battery (non-rechargeable) |
| Brand | SEBA |
|---|---|
| Origin | Germany |
| Model | KLL / KLL-T / KLL-Mini |
| Cable Options | 10–500 m |
| Depth Accuracy | ≤1 cm (up to 300 m) |
| Temperature Accuracy | ±0.10 °C (0–25 °C), ±0.15 °C (0–50 °C) |
| Conductivity Ranges | 4 selectable (20 μS/cm – 50 mS/cm) |
| Power | 6 V DC (KLL/KLL-T, 4 × 1.5 V AA) or 3 V DC (KLL-Mini, 2 × 1.5 V AA) |
| Operating Temp | −15 °C to +50 °C |
| Storage Temp | −40 °C to +80 °C |
| IP Rating | IP68 (probe), IP52 (reel) |
| Probe Diameter | 10–16 mm |
| Display | 8-character LCD (KLL-T) |
| Language Support | English, German, French, Spanish |
| Reel Material | Heat-resistant polymer |
| Frame Material | Anodized aluminum |
| Cable | PE-sheathed dual-steel-core corrosion-resistant cable |
| Brand | SEBA |
|---|---|
| Origin | Germany |
| Model | KLL-S |
| Sampling Capacity | 0.5 L (for 2″ wells), 1.0 L (for 4″ wells) |
| Well Diameter Compatibility | 2″ (50.8 mm) and 4″ (101.6 mm) boreholes |
| Standard Cable Length | 15–500 m (groundwater), 30 m (LNAPL, extendable) |
| Integrated Water Level Measurement | Yes |
| Optional Accessories | Tripod support frame, gasoline-powered air compressor (10 bar, 350 L/min, 3.7 kW, 72 kg), SU-2-N submersible pump system (30 m discharge hose with 50 cm graduations, mobile hose reel, venting & exhaust lines, 34 kg) |
| Brand | SEBA |
|---|---|
| Origin | Germany |
| Model | SEBAPULS |
| Technology | 26 GHz Pulse Radar |
| Accuracy | ±3 mm (SEBAPULS 30), ±5 mm (SEBAPULS 20), ±15 mm (SEBAPULS 70) |
| Measuring Range | 0–20 m / 0–30 m / 0–70 m |
| Operating Temperature | −40 °C to +80 °C |
| Output | 4–20 mA (standard), optional voltage output & remote telemetry (GSM/GPRS, satellite, landline) |
| Antenna Type | Plastic horn (SEBAPULS 20), stainless steel horn (SEBAPULS 30/70) |
| Housing | Aluminum enclosure, IP66 |
| Minimum Distance to Surface | 50 mm |
| Minimum Distance to Mounting Bracket | 20–30 cm |
| Power Consumption | Low-power design optimized for solar/battery operation |
| Brand | SEC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 0318 |
| Instrument Type | Multi-Parameter Soil Analyzer |
| Principle | Sedimentation-Based Particle Size Distribution (Hydrometer Method per ASTM D422 / ISO 11277) |
| Weight | 11.8 kg (26 lbs) |
| Dimensions | 78.7 × 78.7 × 25.4 cm (31 × 31 × 10 in) |
| Compliance | ASTM D422, USDA Soil Taxonomy Guidelines, ISO 11277 |
| Brand | SEC (USA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 0318K1 |
| Price Range | USD 5,000–9,999 |
| Sieve Diameter | 4 in (101.6 mm) |
| Total Kit Weight | 40 lb (18.1 kg) |
| Packaging | 2 Cartons, 31 × 25 × 11 in (787 × 635 × 279 mm) each |
| Core Components | 0371K1 Sieve Shaker + 0318 Standard Soil Sieve Set |
| Brand | SEC (USA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 0371K1 |
| Price Range | USD 5,000–9,999 |
| Sieve Diameter | 4 in (101.6 mm) |
| Unit Weight | 27 lb (12.2 kg) |
| Dimensions (Shaker Base) | 31 × 21 × 10 in (787 × 533 × 254 mm) |
| Dimensions (Sieve Stack Assembly) | 19 × 15 × 7 in (483 × 381 × 178 mm) |
| Power Source | 6 × AA batteries (included) |
| Included Components | 0316D04 Vibratory Sieve Shaker, 3015D04S 4-in Sieve Set (ASTM E11-compliant stainless steel mesh), 7201W05 Precision Electronic Balance (0.01 g readability, 500 g capacity) |
| Brand | SEC (USA) |
|---|---|
| Origin | USA |
| Model | 15 Bar |
| Measurement Range | 0–15 bar |
| Resolution | Not specified |
| Power Supply | 220 V AC |
| Rated Power | 1500 W |
| Operating Environment | Ambient temperature, indoor use only |
| Display Method | Manual data recording |
| Chamber Dimensions | Variable per pressure level (1–15 bar) |
| Ceramic Disc Options | 0.5, 1, 3, 5, and 15 bar variants available |
| Compliance | Designed for ASTM D422, ISO 11277, USDA-SCS and FAO soil physics protocols |
| Software Interface | None (standalone mechanical/pressure-based system) |
| Regulatory Alignment | Compatible with GLP-compliant laboratory documentation workflows |
| Brand | SEC |
|---|---|
| Origin | USA |
| Model | 1905 |
| Outer Diameter | 2.2 cm |
| Ceramic Tip Porosity | High-flow, 1-bar (100 kPa) rated |
| Sampling Mechanism | Threaded cap extraction with compression ring |
| Extension Capability | Compatible with extendable sampling tubes |
| Brand | SEC (USA) |
|---|---|
| Origin | USA |
| Model | 1911 |
| Sampling Depth Range | 15 cm to 3 m |
| Ceramic Tip Material | High-purity alumina (Al₂O₃) |
| Bubble Point Pressure | 100 kPa (1 bar) |
| Tubing Options | 1/4" OD and 1/8" OD nylon tubing |
| Compatible Extraction Kit | SEC 1900K3 (1000 mL) |
| Vacuum Requirement | Continuous vacuum source |
| Compliance | Designed for ASTM D5088, ISO 22030, and US EPA Method 9060A applications |