Environmental Monitoring Instruments
Filter
Showing 6421–6450 of 9029 results
| Brand | ROCKER |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (Taiwan) |
| Model | CR25 |
| Price Range | USD 850–1,150 |
| Digestion Method | Rapid Closed-Reflex Digestion |
| Heating Module | Single Aluminum Block |
| Batch Capacity | 25 Samples |
| Temperature Range | Ambient +5°C to 200°C |
| Temperature Accuracy | ±2°C |
| Temperature Stability | ±1°C |
| Sample Vial Capacity | 15 mL |
| Vial Diameter Compatibility | Ø16 mm |
| Timer Range | 1–999 min (countdown) or continuous mode |
| Preset Programs | COD (150°C/120 min), COD2 (165°C/20 min), TP (150°C/30 min), TN (105°C/30 min), TPN (120°C/30 min), TOC (105°C/120 min) |
| Custom Program Storage | 2 user-defined protocols |
| Power Rating | 350 W |
| Display | OLED screen |
| Net Weight | 5.1 kg |
| Dimensions (L×W×H) | 31 × 19 × 12 cm |
| Input Voltage Options | 110 V / 60 Hz or 220–240 V / 50 Hz |
| Safety Certifications | CE compliant |
| Standard Compliance | NIEA W517.52B (Taiwan EPA), US EPA Method 410.4, ISO 15705:2002 (ST-COD) |
| Brand | Rocker |
|---|---|
| Origin | Taiwan |
| Model | WD100 |
| Instrument Type | Portable |
| Measurement Principle | UV-Vis Absorption Spectrophotometry |
| Wavelengths | 420 nm, 610 nm (auto-selected) |
| Measurement Range | 10–5000 mg/L |
| Accuracy | ≤ ±10% |
| Repeatability | ≤ 0.005 Abs / 30 min |
| LOD | 0.1 mg/L |
| Measurement Time | 3 seconds |
| Sample Throughput | 1 cuvette per assay |
| Display | Backlit LCD |
| Light Source | LED |
| Data Storage | 100 records |
| Data Fields | Parameter, Wavelength, Concentration, Sample ID, Timestamp |
| Power Supply | DC 9 V battery or AC adapter (100–240 V AC input) |
| Dimensions | 23 × 13 × 9 cm |
| Certifications | CE |
| Origin | Non-China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | ROW |
| Price | Upon Request |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | RPB |
| Pricing | Upon Request |
| Brand | RPR |
|---|---|
| Origin | United Kingdom |
| Model | WS15A |
| Sensor Type | Ultrasonic (no moving parts) |
| Measurement Range | Wind Speed 0.02–60 m/s |
| Wind Direction | 0–360° continuous |
| Output Interfaces | RS232 (≤15 m), RS232/422/485 (≥15 m or EMI-prone environments), Optional Analog Output (0–5 V / 4–20 mA) |
| Data Storage | WindLogger with MMC card (up to 2 GB) |
| Display | Integrated WS-15A real-time LCD display |
| Alarm Output | Configurable digital alarm relay |
| Start-up Threshold | 0.02 m/s |
| Enclosure Rating | IP66 |
| Operating Temperature | −30°C to +70°C |
| Compliance | CE, RoHS, EN 61326-1 (EMC), EN 61000-6-2/6-3 |
| Brand | LANYO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | RTTC-10 |
| Sampling Depth | 2 m |
| Unit Weight | 6 kg (main unit) |
| Power Source | Rechargeable Lithium Battery |
| Sampling Method | Percussion-driven Core Sampling |
| Optional Accessory | Removable Liner Tube for Cohesive Soils |
| Operation Mode | Single-operator Portable System |
| Compliance | Designed for field-deployable ISO 10381-2 and ASTM D1586-compliant soil sampling |
| Brand | Ruinen Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Product Type | Online Gas Analyzer |
| Model | GC3900N |
| Detection Targets | Total Hydrocarbons (THC), Methane (CH₄), Non-Methane Hydrocarbons (NMHC) |
| Measurement Range | CH₄ (0.1–10,000 ppm), NMHC (0.05–10,000 ppm) |
| LOD | ≤0.1 ppm (CH₄), ≤0.05 ppm (NMHC) |
| Repeatability | RSD ≤2% |
| Cycle Time | ≤40 s (single-channel), ≤20 s (dual-channel) |
| Detector | FID (Flame Ionization Detector) |
| Carrier Gas | Ultra-High-Purity Nitrogen or Zero-Air (≥99.999%) |
| Fuel Gas | Ultra-High-Purity Hydrogen (≥99.999%) |
| Make-up/Support Air | Zero-Air (hydrocarbon <20 ppb) |
| Sampling | Automated Six-Port Valve with Fixed-Volume Loop |
| Sample Temp. Range | Ambient to 180 °C |
| Sample Flow Rate | ≥0.5 L/min or Pressure ≥0.1 MPa |
| Particle-Free Requirement | Yes |
| Form Factor | 6U 19″ Rack-Mount Chassis |
| Power | <400 W, 220 V AC / 50 Hz |
| Analog Output | 4–20 mA |
| Digital Interface | RS232 / RS485 |
| Operating Environment | –10 to +50 °C, 10–100% RH |
| Brand | Ruinen Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Model | RNZ-1000Z |
| Zero Air Purity | NO < 0.1 ppb |
| Flow Rate | 1000 mL/min |
| Output Pressure Range | 0–0.6 MPa |
| Dew Point | −20 °C |
| Hydrocarbon Content (Output) | < 0.1 ppm |
| Max. Inlet Hydrocarbon Concentration | < 100 ppm |
| Inlet Pressure Range | 0–0.6 MPa |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Power Consumption | 350 W |
| Catalyst Operating Temperature | 350–400 °C |
| Ambient Operating Temperature | 0–40 °C |
| Ambient Humidity | < 85 % RH |
| Required Inlet Air | Clean, Dry Compressed Air |
| Communication Interface | RS-485 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | SZ-8D |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Detection Parameters | Ammonia-N, Total Phosphorus, Total Nitrogen, COD (Cr), Residual Chlorine, Total Chlorine, Dissolved Oxygen, Volatile Phenols, Chlorine Dioxide |
| Display | 4.3-inch Color TFT Touchscreen |
| Absorbance Range | 0.000–4.000 AU |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 AU |
| Photometric Accuracy | ±2.0% T |
| Photometric Repeatability | ≤0.2% T |
| Baseline Stability | ≤0.3% (3 min) |
| Communication Interface | USB |
| Power Supply | AC 220 V / DC 5 V / Rechargeable Lithium Battery |
| Brand | RuiXin |
|---|---|
| Origin | Shanghai, China |
| Model | SZ-CL |
| Instrument Type | Portable |
| Measurement Parameter | Residual Chlorine |
| Detection Range | 0.05–10.00 mg/L |
| Accuracy | ≤5% |
| Repeatability | ≤2% |
| Resolution | 0.01 mg/L |
| Limit of Detection (LOD) | 0.02 mg/L |
| Display | 4.3-inch color TFT touchscreen |
| Absorbance Range | 0.000–4.000 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy | ±2.0% (transmittance) |
| Photometric Repeatability | ≤0.2% |
| Baseline Stability | ≤0.3% (over 3 min) |
| Communication Interface | USB |
| Power Supply | AC 220 V / DC 5 V / Rechargeable Li-ion battery |
| Integrated Thermal Printer | Yes |
| Data Storage & Recall | Yes |
| Data Export Capability | Yes |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Distributor |
| Country of Origin | Domestic (China) |
| Model | SZ-RJ2 |
| Price | ¥5600 |
| Display | 4.5-inch color LCD touchscreen |
| Absorbance Range | 0.000–4.000 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy | ±2.0% |
| Photometric Repeatability | ≤0.2% |
| Baseline Stability | ≤0.3% (3 min) |
| DO Measurement Range | 1.0–10.0 mg/L |
| Communication Interface | USB |
| Power Supply | AC 220 V / DC 5 V / Rechargeable Li-ion battery |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | SZ-XD402 |
| Instrument Type | Portable |
| Measurement Principle | DPD Colorimetric Spectrophotometry |
| Measurable Parameters | Residual Chlorine, Total Chlorine, Chlorine Dioxide, Ozone, Dissolved Oxygen |
| Range | 0.05–5.00 mg/L (Cl₂, ClO₂, O₃, DO) |
| Accuracy | ±3% FS |
| Repeatability | ±0.05 mg/L |
| Resolution | 0.01 mg/L |
| LOD | 0.05 mg/L |
| Absorbance Range | 0.000–4.000 (Resolution: 0.001) |
| Transmittance Range | 0.00–100.00% (Resolution: 0.01%) |
| Photometric Accuracy | ±2.0% T |
| Photometric Repeatability | ≤0.2% T |
| Stability | ≤0.3% T (3 min) |
| Display | 4.5-inch color TFT touch LCD |
| Connectivity | USB interface |
| Power Supply | AC 220 V / DC 5 V / Rechargeable Li-ion battery |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | PG Series |
| Detection Principle | Electrochemical Sensors (H₂S, NH₃, CH₃SH, (CH₃)₂S, CH₃SSCH₃, CS₂, C₈H₈, (CH₃)₃N, NOₓ, O₃) + Optional PID for VOCs |
| Form Factor | Portable |
| Response Time | < 30 s (typical for electrochemical sensors) |
| Repeatability | ±2% FS (for calibrated target gases) |
| Communication Protocols | Modbus RTU/TCP, RS485, Bluetooth/Wi-Fi optional |
| Sensor Interface | Hot-swappable intelligent electrochemical & PID modules |
| Compliance | CE-marked |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | MG Series |
| Pricing | Available Upon Request |
| Measurement Principle | Electrochemical Sensing (with optional PID for VOCs) |
| Configuration | Fixed-Installation Online Analyzer |
| Response Time | < 30 s (typical for electrochemical sensors) |
| Repeatability | ±2% FS for H₂S, NH₃, CH₃SH, (CH₃)₂S, CH₃SSCH₃, CS₂, C₈H₈, (CH₃)₃N, NOₓ, O₃ |
| Detectable Gases | H₂S, NH₃, CH₃SH, (CH₃)₂S, CH₃SSCH₃, CS₂, C₈H₈, (CH₃)₃N, NOₓ, O₃, SO₂, VOCs (via PID), and derived odor unit (OU) calculation per GB/T 14675–2023 and EN 13725:2022 |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | RZL01 |
| Quotation | Upon Request |
| Instrument Type | Soil Moisture / Matric Potential Analyzer |
| Slope Adjustment Range | 0–30° |
| Actuation | Electric Motor-Driven Screw Mechanism |
| Modular Partitioning | Configurable into 2 or 4 laterally isolated test sections |
| Drainage | Perforated base for subsurface flow collection |
| Mobility | Integrated wheeled chassis for field and lab relocation |
| Brand | — |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Model | S-16 |
| Typical Configuration | Integrated Particulate Imaging Sampler |
| Dimensions | 120 × 70 × 40 mm |
| Weight | 0.35 kg |
| Power Supply | 12 V DC |
| Power Consumption | 5 W |
| Operating Temperature | 0–60 °C |
| Operating Humidity | 0–80 % RH (non-condensing) |
| Acoustic Noise | ≤10 dB(A) at 1 m |
| Battery Runtime | Up to 1.5 h (rechargeable Li-ion integrated) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | S/O-M |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S80 |
| Price Range | USD 2,800–7,000 (FOB) |
| Instrument Type | Online Multi-Ion Analyzer |
| Measurement Range | 0.01–32,000 ppm |
| Detection Limit | 0.01 ppm |
| Response Time | ≤1 s |
| Accuracy | ±10% of reading |
| Operating Temperature | −20 °C to +70 °C |
| Brand | Sabio |
|---|---|
| Origin | USA |
| Model | 4010 |
| Flow Accuracy | ±1.0% of Full Scale |
| Flow Repeatability | ±0.15% of Full Scale |
| Flow Linearity | ±0.5% of Full Scale |
| Diluent MFC Range | 0–10 SLPM (optional 0–20 SLPM) |
| Source MFC Range | 0–100 SCCM (optional 0–50 / 0–200 / 0–500 SCCM / 0–1 SLM) |
| Input Pressure | 20–35 psig |
| Ozone Output Range | 0.05–1.5 ppm at 5 SLPM (extendable to 0.05–1.0 ppm at 15 SLPM) |
| Ozone Accuracy | ±2% of setpoint or ±3 ppb at 5 SLPM |
| Ozone Flow Control Precision | ±1 SCCM at 100 SCCM |
| 95% Setpoint Response Time | <60 s |
| Wetted Materials | 316 Stainless Steel, PTFE, PEEK, Halar |
| Seals | Viton, Kalrez |
| Optional Internal Permeation Oven | 94 cm³ Volume, 13.2 cm Length, 3.02 cm ID, Temperature Stability: ±0.1°C (setpoint +60°C above ambient), Preheat Time: <30 min |
| Brand | Sabio |
|---|---|
| Origin | Beijing, China |
| Model | 4010L |
| Diluent Flow Range | 0–10 SLM (optional up to 20 SLM) |
| Source Gas Flow Range | 0–100 SCCM / 0–10,000 SCCM |
| Flow Accuracy | ≤ ±1% FS |
| Flow Repeatability | ≤ ±0.15% FS |
| Linearity | ≤ ±0.5% FS |
| Inlet Pressure | 20–35 PSIG |
| Ozone Generator Output | 0.05–1.5 ppm at 5 SLPM |
| Ozone Generator Accuracy | ±1% of setpoint or ±2 ppb at 5 SLPM |
| UV Absorption Photometer Range | 0–0.5 / 1.0 / 2.0 ppm |
| Photometer Zero Drift | < ±1 ppb per 24 h (or 30 days) |
| Photometer Flow Rate | 1.0 LPM |
| Dilution Furnace Temperature Range | Ambient +5 °C to 65 °C |
| Temperature Stability | < ±0.1 °C |
| Calibration Programs | 20 user-configurable, time- and event-driven (7-day cycle support) |
| Input/Output | 24-bit digital I/O, 2× serial ports (RS232 standard), parallel printer port, external keyboard interface, air source control port |
| Display | High-brightness color LCD |
| Keypad | 55-key membrane panel |
| Gas Ports | 4 source gas inlets, 1 purge inlet, 1 diluent inlet, 5 calibrated outputs, 1 exhaust port |
| Brand | Sabio |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Model 2010 |
| Pricing | Upon Request |
| Diluent Mass Flow Range | 0–10 SLM (optional up to 20 SLM) |
| Source Gas Mass Flow Range | 0–100 SCCM (optional up to 2 SLM) |
| Flow Accuracy | ≤1% FS |
| Flow Repeatability | ≤±0.15% FS |
| Linearity | ≤±0.5% FS |
| Response Time | <60 s |
| Control Interfaces | Keypad, Keyboard, RS-232 Serial, USB, Ethernet |
| Predefined Calibration Paths | 20 factory-configured flow paths, each supporting up to 20 linear calibration points |
| Supported Calibration Types | Diluent gas, Ozone (O₃), Gas Phase Titration (GPT) |
| Temperature Control System | Microprocessor-based proportional PID controller |
| Temperature Sensor | Platinum RTD (Pt100) |
| Heating Zone Dimensions | Internal Diameter 3.09 cm, Length 12.7 cm |
| Temperature Range | Ambient +2 °C to 65 °C |
| Front Panel Integration | Adjustable pressure regulator, analog pressure gauge, digital temperature controller, Teflon-lined dilution furnace inlet |
| Brand | Sabio |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Model 2030 |
| Price | Upon Request |
| Measurement Principle | UV Absorption at 254 nm (Beer–Lambert Law) |
| Range Options | 0–100 / 0–200 / 0–500 ppb or 0–1 / 0–2 ppm |
| Detection Limit | 1 ppb |
| Zero Noise | 0.6 ppb RMS |
| Zero Drift | <1.0 ppb/24 hr, <2.0 ppb/7 days |
| Span Drift | <1% per month |
| Response Time | 20 s (10 s delay) |
| Accuracy | ±1 ppb |
| Linearity | ±1% of full scale |
| Sample Flow Rate | 1 L/min |
| Operating Temperature | 5–45 °C |
| Power Supply | 98–132 VAC / 196–264 VAC, 50/60 Hz |
| Analog Outputs | Four independent, scalable (0.1 V / 1 V / 2 V / 5 V / 10 V) |
| Digital Interfaces | USB, RS-232/RS-485 (DB-9) |
| Display | Color LCD with touchscreen, front-panel keys, external keyboard/mouse support |
| Data Storage | Internal logging with timestamped records |
| Built-in Ozone Generator | 0.05–1.5 ppm @ 5 SLM, ±2% of setpoint or ±3 ppb @ 5 SLM |
| Auto Zero Compensation | Yes |
| Temperature & Pressure Compensation | Yes |
| Dimensions | 15.6 cm H × 36.4 cm W × 31.6 cm D |
| Weight | 9.1 kg |
| Brand | Sabio |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 6040 |
| Price | Upon Request |
| Measurement Principle | Chemiluminescence Detection |
| Range | 0–50 ppb to 0–20 ppm (user-selectable) |
| Units | ppm, ppb |
| Display | High-resolution color TFT LCD |
| Interface Options | Touchscreen, front-panel keypad, external keyboard/mouse |
| Data Logging | Internal non-volatile memory with timestamping |
| Communication | Ethernet (TCP/IP), USB 2.0 (host & device), RS-232/485 |
| Analog I/O | 4 channels, configurable voltage output (0.1 V, 1 V, 2 V, 5 V, 10 V) |
| Digital I/O | 8 standard TTL-compatible inputs/outputs |
| Environmental Compensation | Automatic temperature and pressure correction |
| EPA Certification | RFNA-0418-250 |
| Detection Limit | < 0.4 ppb |
| Noise | < 0.2 ppb |
| Zero Drift | < 0.5 ppb/24 hr |
| Accuracy | < 0.5% of full scale |
| Sample Flow Rate | 0.4–0.8 L/min |
| Operating Temperature | 5–45 °C (EPA-specified range) |
| Operating Humidity | 0–90% RH (non-condensing) |
| Power Requirement | 200 W, 100–240 VAC, 50/60 Hz |
| Dimensions (H×W×D) | 133 × 432 × 571.5 mm |
| Weight | 11.3 kg (25 lbs) |
| Protocols | Modbus RTU/TCP, SCPI-compliant command set |
| Brand | Sabio |
|---|---|
| Origin | Beijing, China |
| Model | Sabio2010 |
| Diluent Flow Range | 0–10 SLM (up to 20 SLM optional) |
| Source Gas Flow Range | 0–100 SCCM (up to 2 SLM optional) |
| Flow Accuracy | <1% FS |
| Flow Repeatability | ±0.15% FS |
| Linearity | ±0.5% FS |
| Inlet Pressure | 12–35 PSIG |
| Operating Temperature | 5–40°C |
| Dimensions | 156 mm (H) × 364 mm (W) × 316 mm (D) |
| Weight | 8.6 kg |
| Power Supply | 98–264 VAC, 100 VA, 50/60 Hz |
| Communication Interfaces | RS-232, Ethernet (TCP/IP optional) |
| Digital I/O | 8-bit TTL/contact-triggered |
| Calibration Paths | 20 preconfigured, each supporting up to 20 linear points |
| Gas Configuration | 1 diluent + 20 source gases |
| Output Ports | 3 calibrated outputs + 1 exhaust port (1 permeation port optional) |
| Input Interface | 42-key membrane keypad or external keyboard |
| Brand | Sable |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | DR4-Series Dynamic Respirometer |
| Pricing | Upon Request |
| Brand | Sable |
|---|---|
| Origin | USA |
| Model | SoilBox-FGA |
| Instrument Type | Multi-parameter Soil Respiration & Gas Exchange Analyzer |
| O₂ Analyzer | Fuel Cell Technology |
| CO₂ Analyzer | Nondispersive Dual-Wavelength Infrared (NDIR) |
| O₂ Range | 0–100% |
| CO₂ Range | 0–5% |
| O₂ Accuracy | ±0.1% |
| CO₂ Accuracy | ±1% of reading |
| O₂ Resolution | 0.001% |
| CO₂ Resolution | 0.0001–0.01% (range-dependent) |
| O₂ Drift | <0.02%/hr (constant temperature) |
| CO₂ Drift | <0.001%/hr (constant temperature) |
| Flow Control | Microprocessor-regulated thermal feedback loop with integrated diaphragm pump and thermal-mass flowmeter |
| Flow Range | 10–1700 mL/min |
| Flow Accuracy | ±2% |
| Flow Resolution | 0.1 mL/min (0–99.9 mL/min), 1 mL/min (>100 mL/min) |
| Data Storage | 8,190 points |
| Logging Interval | 0.1 s to 1 h (user-configurable) |
| Display | 4-line LCD (real-time CO₂, O₂, flow rate, status) |
| I/O | 2× BNC analog inputs, 3× BNC analog outputs (O₂, CO₂, user-defined), RS-232 digital interface |
| Power | 12–15 VDC, 50–500 mA |
| Operating Temperature | 0–50 °C (non-condensing) |
| Dimensions (FGA unit) | 31 × 18 × 31 cm |
| Weight (FGA unit) | 5 kg |
| Soil Chamber | Aluminum or transparent acrylic, 20 cm ID × 20 cm height, low thermal inertia design |
| Optional Sensors | Soil temperature (thermistor, –5 to 60 °C, ±0.2 °C), air humidity (±2% RH), PAR/solar radiation (±5%), soil moisture (TRIME-PICO TDR), external CH₄ analyzer (dual-wavelength IR, 0–10%, 1 ppm resolution, ±1% accuracy, pressure-compensated) |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | SoilBox-FMS |
| Instrument Type | Multifunctional Soil Analyzer |
| Key Specifications | CO₂ resolution ≤0.0001%, O₂ resolution 0.001%, H₂O resolution 0.001% RH, flow control 10–1500 mL/min (±2% accuracy), 14-channel data logger, dual-path baseline switching, integrated T/P compensation, 0.1 s–1 h user-defined logging interval, 32 GB SD storage, 12–15 VDC operation (AC adapter & optional Li-ion battery), operating temp 3–50 °C, dimensions 35 × 30 × 15 cm, weight 4 kg |
| Brand | Sable |
|---|---|
| Origin | USA |
| Model | SoilLab |
| Instrument Type | Multi-channel Laboratory Soil Respiration System |
| Gas Analyzers | CO₂ (NDIR), O₂ (Fuel Cell), Optional CH₄ (TCD), H₂O (Capacitive) |
| Channel Configurations | 4, 8, 16, or 24 channels |
| Compliance | ISO 14240-1 (Substrate-Induced Respiration for Microbial Biomass), ASTM D5039 (Soil Respiration Testing), GLP-Compatible Data Logging |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | SabreASC |
| Pricing | Upon Request |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AT-DX100 |
| Instrument Type | Portable |
| Biological Agent | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) bioluminescent bacteria |
| Operating Temperature Range | 0–70 °C |
| Reagent Storage & Usage Temperature | 0–55 °C |
| Coefficient of Variation (CV) | ≤5% |
| Batch Capacity | 1–10 samples per run |
| Detection Time | ≤5 minutes |