Flash Point Ignition Point Instrument
Filter
Showing 61–90 of 92 results
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SYP1001-V-J |
| Test Method | Cleveland Open Cup (COC) |
| Standards Compliance | GB/T 3536, ASTM D92, ISO 2592, SY/T 5645 |
| Cleveland Cup Material | H62 Brass |
| Cup Inner Diameter | Φ63.5 ± 0.5 mm |
| Ignition Source | Liquefied Petroleum Gas (LPG), Butane, or Town Gas |
| Igniter Orifice Diameter | 0.8 mm |
| Flame Sphere Diameter | φ4 mm |
| Heating Element Power | 400 W |
| Temperature Sensor | PT100, Range: 0–410 °C |
| Thermometer | GB/T 514 compliant, -6 to 400 °C, 2 °C graduation |
| Remote Control Distance | ≥10 m |
| Auto-Stop Conditions | 21 °C above expected flash point or sample temperature >400 °C |
| Voltage Compensation | Yes (maintains consistent heating rate under fluctuating line voltage) |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SYP1002B-IV |
| Test Method | Closed-Cup (Pensky-Martens) |
| Standards Compliance | GB/T 261, ISO 2719, ASTM D93, IP 34 |
| Heating Power | 500 W |
| Temperature Range | −5°C to 370°C (with three calibrated thermometer ranges) |
| Stirring Speeds | 90–120 rpm and 250 ±10 rpm |
| Ignition Motor Speed | 24 rpm |
| Cooling Rate | 12–14 °C/min |
| Cup Type | Standard Pensky-Martens closed cup (GB/T 261 compliant) |
| Ignition Orifice Diameter | 0.7 mm |
| Voltage Control Range | 0–220 V (digitally set, 3½-digit LCD display) |
| Flame Adjustment | Via adjustable gas flow valve for butane, propane, or town gas |
| Brand | SPECTRA INVENT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-FP1100 |
| Detection Method | Closed Cup (Pensky-Martens) |
| Operation Mode | Manual with Touchscreen Interface |
| Temperature Range | Ambient to 300 °C |
| Ignition Source | Electronic Spark Igniter |
| Repeatability | ≤2 °C |
| Compliant Standards | GB/T 261, GB/T 21615, ASTM D93 |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (PRC-manufactured) |
| Model | HX-FP1110 |
| Detection Method | Closed Cup (Pensky-Martens Principle) |
| Operation Mode | Manual |
| Ignition Source | Pressurized Gas Flame (Propane/Butane) |
| Compliant Standards | GB/T 261–2021, ASTM D93–22 |
| Brand | SPECTRA INVENT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-FP1110A |
| Detection Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient to 350°C |
| Ignition Source | Electronic Spark & Adjustable Gas Flame |
| Repeatability | ≤2°C |
| Applicable Standard | GB/T 261-2008 |
| Brand | SPECTRA INVENT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-FP1120A |
| Detection Method | Cleveland Open-Cup (COC) |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient to 400 °C |
| Ignition Method | Electronic Spark Ignition |
| Repeatability | ≤4 °C |
| Applicable Standards | ASTM D92, GB/T 3536 |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ABL-8 |
| Test Method | Closed-Cup (Abel) |
| Operation Mode | Fully Automatic |
| Applicable Standards | GB/T 21789, IP 170, ISO 13736, ISO 1516, ISO 1523 |
| Temperature Range | −30 °C to +80 °C |
| Ignition System | Dual-mode (Gas Flame & Electric Spark) |
| Repeatability | High |
| Cooling Method | Peltier-based Semiconductor Cooling |
| Display | 5.7-inch Color LCD |
| Data Storage Capacity | 200 Test Records |
| Atmospheric Pressure Compensation | Integrated Barometric Sensor |
| Safety Features | Auto Fire Suppression, Fault Diagnostics, Wind Shield Enclosure |
| Compliance Support | ASTM D3278, ISO/IEC 17025 Traceability Framework, GLP Audit Trail Ready |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ACO-100 |
| Test Method | Cleveland Open Cup (COC) |
| Operation Mode | Fully Automatic |
| Applicable Standards | ISO 2592, ASTM D92, IP 36 |
| Ignition Source | Electric or Gas Pilot Flame |
| Temperature Range | Ambient to 400 °C |
| Data Storage Capacity | 200 test records |
| Interface Options | USB, RS-232 |
| Optional Accessories | Thermal Printer, USB Keyboard, USB Flash Drive |
| Security | Password-protected test program |
| Safety Features | Auto-ignition detection, auto-extinguishing system (activated upon flash point confirmation or sustained flame ≥5 s) |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | APM-100 |
| Test Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Applicable Standards | ASTM D93, GB/T 261, ISO 2719 |
| Ignition Source | Dual-mode (Gas Flame & Electric Spark) |
| Temperature Range | Ambient to 370 °C |
| Data Storage Capacity | 200 test records |
| Interface | USB (for keyboard, flash drive, and LIMS export) |
| Security | Password-protected test program |
| Safety Features | Integrated thermal cutoff, flame detection interlock, and automatic lid closure |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ASC-8C |
| Test Method | Closed-Cup Equilibrium Method |
| Operating Mode | Fully Automatic |
| Applicable Standards | ISO 3679, ISO 3680, ASTM D3278, ASTM D7236, IP 534 |
| Temperature Range | −30 °C to +100 °C |
| Ignition Source | Dual-mode (electric spark or gas flame) |
| Repeatability | High |
| Atmospheric Pressure Compensation | Integrated barometric sensor |
| Data Storage Capacity | 200 test records |
| Output Options | Thermal printer, USB export, LIMS integration |
| Security | Password-protected user interface |
| Compliance | Designed for GLP-compliant laboratories and routine QC environments |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | FP-C1A |
| Temperature Range | 0–400 °C (Typical Test Range: 80–400 °C) |
| Temperature Sensor | Pt100 Platinum Resistance Thermometer |
| Atmospheric Pressure Sensor | Silicon-based Barometric Sensor |
| Flash Detection | Electrode-based Ionization Detector |
| Fire Point Detection | Infrared Sensor |
| Display | LCD Panel |
| Heater Power | 800 W |
| Cooling Method | Forced Air Cooling |
| Ignition Source | Gas-fired (Propane/Butane) |
| Interface | RS-232C Serial Port |
| Weight | 18 kg |
| Dimensions (Test Unit) | 215(W) × 410(D) × 260(H) mm |
| Dimensions (Control Unit) | 215(W) × 480(D) × 110(H) mm |
| Data Storage Capacity | 99 Test Records |
| Compliance | GB/T 3536–2008, ASTM D92–05a, ISO 2592 |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | FP-P1A |
| Temperature Range | 0–360 °C (Operating: 40–360 °C) |
| Temperature Sensor | Pt100 Platinum Resistance Thermometer |
| Pressure Sensor | Silicon-based Barometric Sensor |
| Ignition Source | Gas-fired Pilot Flame |
| Detection Method | Thermocouple-based Flash Detection |
| Display | LCD Panel |
| Heater Power | 500 W |
| Cooling | Forced Air |
| Interface | RS-232C Serial Port |
| Dimensions (Test Unit) | 215(W) × 410(D) × 270(H) mm |
| Dimensions (Control Unit) | 215(W) × 480(D) × 110(H) mm |
| Weight | 16 kg |
| Compliance | GB/T 261–2008, ASTM D93 (Methods A & B) |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | FP92 |
| Detection Method | Cleveland Open Cup (ASTM D92 / ISO 2592) |
| Operation Mode | Fully Automatic |
| Temperature Range | 80–400 °C |
| Ignition Method | Fully Automatic Gas Flame |
| Compliant Standards | GB/T 3536-2022, ISO 2592:2021, ASTM D92-22, IP 36/07, JIS K 2265:2014 |
| Display | VFD Fluorescent Screen |
| Temperature Sensor | Pt100 Platinum Resistance Thermometer |
| Flash Detection | Ionization Ring (O-Ring Type) |
| Fire Point Capability | Yes (FIRE Mode with Integrated Extinguishing Function) |
| Pressure Compensation | Manual (ACOC) or Auto (ACOCH) |
| Data Storage | 50 Test Records |
| Interface | RS-232C Serial Port |
| Power Supply | AC 230 V, 50 Hz, 1000 W |
| Dimensions | 231 × 456 × 386 mm (W × D × H) |
| Net Weight | 20 kg |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | FP92B |
| Test Method | Cleveland Open Cup (COC), ASTM D92-compliant |
| Operation Mode | Fully Automatic |
| Temperature Range | 79–400 °C |
| Ignition Method | Fully Automatic Gas Flame |
| Compliant Standards | GB/T 3536-2022, ISO 2592, ASTM D92, IP 36, JIS K 2265 |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | XF-170 |
| Detection Method | Closed-Cup (Abel) |
| Standards Compliance | ISO 13736, ISO 1516, ISO 1523, IP 170, GB/T 21789-2008, GB/T 27847-2011, GB/T 27848-2011 |
| Temperature Range (XF-170A) | +10 °C to +110 °C |
| Temperature Range (XF-170B) | 0 °C to +110 °C |
| Extended Range (with DW-25 chiller) | −30 °C to +80 °C |
| Cooling System | Integrated Peltier thermoelectric cooling bath |
| Stirring Speed | 0–30 rpm (adjustable) |
| Temperature Sensor | PT100 platinum resistance thermometer |
| Flash Detection | CRC-type thermocouple sensor |
| Ignition Options | Gas flame (external fuel supply) or electronic spark ignition |
| Display | Full-color capacitive touchscreen LCD |
| Power Consumption | 800 W |
| Dimensions | 400 × 380 × 350 mm (W×D×H) |
| Weight | ~20 kg |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | XF-2S |
| Detection Method | Closed-Cup Method |
| Temperature Control Accuracy | ±0.1 °C |
| Operating Temperature Range (Closed Cup) | 0–300 °C |
| Operating Temperature Range (Open Cup) | 0–400 °C |
| Compliance | ASTM D56, ASTM D92, ASTM D93, GB/T 261-2008, GB/T 3536-2008, GB/T 21929-2008, GB/T 267 |
| Display | Large LCD Screen |
| Data Output | Built-in Dot-Matrix Printer |
| Interface | RS-232C Serial Port |
| Power Consumption | 800 W × 2 |
| Dimensions (W×D×H) | 400 × 380 × 350 mm |
| Weight | ~20 kg |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | XF-4S |
| Detection Method | Cleveland Open-Cup (COC), Pensky-Martens Closed-Cup (PMCC), Tag Closed-Cup (TAG) |
| Temperature Control Range | 0–400 °C (Open-Cup), 0–300 °C (Closed-Cup), ±0.1 °C accuracy |
| Sample Capacity | Up to 8 simultaneous cups (configurable per test standard) |
| Compliance | ASTM D92, ASTM D93, ASTM D56, GB/T 261, GB/T 3536, GB/T 267 |
| Interface | RS-232C |
| Power | 2 × 800 W |
| Dimensions | 400 × 380 × 350 mm (W×D×H) |
| Weight | ~20 kg |
| Detection Principle | Flame Ionization (open-cup), High-Sensitivity Thermocouple (closed-cup) |
| Data Storage | 100 test records per method configuration |
| Display | Large LCD with real-time temperature, setpoint, and fault diagnostics |
| Printer | Built-in dot-matrix |
| Brand | XuFeng |
|---|---|
| Origin | Shanghai, China |
| Model | XF-5208 |
| Detection Method | Closed-Cup Rapid Equilibrium Method |
| Compliance | GB/T 5208–2008, ISO 3679:2004 |
| Temperature Range (XF-5208L) | –5 °C to 110 °C |
| Temperature Range (XF-5208H) | Ambient to 300 °C |
| Sample Volume (XF-5208L) | 2 mL per test |
| Sample Volume (XF-5208H) | 4 mL per test |
| Control Accuracy | ±0.5 °C |
| Interface | RS-232C |
| Power Consumption | 800 W × 2 |
| Dimensions | 280 mm (W) × 380 mm (D) × 350 mm (H) |
| Weight | ~15 kg |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | XF-56 |
| Detection Method | Closed-Cup (Tag) |
| Applicable Standards | ASTM D56, SH/T 0733, GB/T 21929-2008, ISO 1523, IP 304, JIS K 2265 |
| Temperature Control Range | 0 °C to 300 °C |
| Control Accuracy | ±0.1 °C |
| Standard Test Range | Ambient to 95 °C (water bath) |
| Cooling Source | Imported Semiconductor Cold Trap |
| Display | Full-Touch 7-inch LCD |
| Ignition Detection | Automated Flame Ignition + High-Sensitivity Thermocouple |
| Power Consumption | 2 × 800 W |
| Dimensions | 400(W) × 380(D) × 350(H) mm |
| Weight | ~20 kg |
| Interface | RS-232C |
| Printer | Integrated Dot-Matrix Printer |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | XF-56SE |
| Detection Method | Closed-Cup (Tag) |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient to 95 °C (standard) |
| Ignition Methods | Electric spark ignition (standard on XF-56SE) and external fuel gas ignition (compatible via optional inlet) |
| Repeatability | Compliant with ASTM D56, SH/T 0733, and GB/T 21929-2008 |
| Applicable Standards | ASTM D56, SH/T 0733, GB/T 21929-2008, ISO 1523, IP 304, JIS K 2265 |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | XF-56SE |
| Detection Method | Closed-Cup (Tag) |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient to 95 °C |
| Ignition Method | Electronic (Piezoelectric Spark) |
| Repeatability | Compliant with ASTM D56, SH/T 0733, and GB/T 21929–2008 specifications |
| Applicable Standards | ASTM D56, SH/T 0733, GB/T 21929–2008, ISO 1523, IP 304, JIS K 2265 |
| Brand | XuFeng |
|---|---|
| Origin | Shanghai, China |
| Model | XF-92 |
| Detection Method | Open Cup (Cleveland) |
| Standards Compliance | ASTM D92, GB/T 3536-2008, GB/T 267 |
| Temperature Range | 0–400 °C |
| Control Accuracy | ±0.1 °C |
| Typical Test Range | 80–400 °C |
| Power Consumption | 2 × 800 W |
| Dimensions | 400 × 380 × 350 mm (W×D×H) |
| Weight | ~20 kg |
| Display | Full-touch LCD screen |
| Interface | RS-232C |
| Output | Integrated dot-matrix printer |
| Ignition | Automatic gas-fired or optional electronic igniter |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | XF-9293 |
| Testing Method | Closed-Cup & Open-Cup |
| Temperature Control Accuracy | ±0.1 °C |
| Operating Temperature Ranges | Closed-Cup (0–300 °C), Open-Cup (0–400 °C), Tag Closed-Cup (0–95 °C, optional Peltier cooling) |
| Detection Methods | Flame Ionization (Open-Cup), High-Sensitivity Thermocouple (Closed-Cup) |
| Compliance Standards | ASTM D56, ASTM D92, ASTM D93, GB/T 261, GB/T 3536, GB/T 21929, SH/T 0733, GB/T 267 |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | XF-92S |
| Detection Method | Open-Cup |
| Operation Mode | Fully Automatic |
| Temperature Range | 80 °C to 400 °C |
| Ignition Modes | Electric Spark Ignition and External Fuel-Gas Ignition |
| Repeatability | Compliant with ASTM D92 and GB/T 3536 test protocols |
| Applicable Standards | ASTM D92, GB/T 3536 |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | XF-92SE |
| Detection Method | Cleveland Open Cup (ASTM D92 / GB/T 3536) |
| Operation Mode | Fully Automatic |
| Temperature Range | 80 °C to 400 °C |
| Ignition Methods | Electric spark ignition (standard) and optional gas-fueled ignition |
| Repeatability | Compliant with ASTM D92 and GB/T 3536 requirements |
| Applicable Standards | ASTM D92, GB/T 3536 |
| Brand | XuFeng |
|---|---|
| Origin | Shanghai, China |
| Model | XF-93 |
| Detection Method | Closed-Cup Method (Pensky-Martens) |
| Standards Compliance | ASTM D93, GB/T 261–2008 |
| Temperature Range | 0–360 °C (Typical Test Range: 40–360 °C) |
| Temperature Control Accuracy | ±0.1 °C |
| Power Consumption | 2 × 800 W |
| Dimensions (W×D×H) | 400 × 380 × 350 mm |
| Weight | ~20 kg |
| Display | Full-touch LCD screen |
| Interface | RS-232C |
| Output | Integrated dot-matrix printer |
| Ignition | Automatic gas-fired or optional electronic ignition head |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | XF-93S |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Temperature Range | 40 °C to 360 °C |
| Ignition Modes | Electric Spark Ignition & External Fuel-Gas Ignition |
| Repeatability | Compliant with ASTM D93 and GB/T 261 test protocols |
| Applicable Standards | GB/T 261–2008, ASTM D93 |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | XF-93SE |
| Detection Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Temperature Range | 40 °C to 360 °C |
| Ignition Methods | Electric Spark Ignition (standard) and Optional Gas-Fueled Ignition |
| Repeatability | Compliant with ASTM D93, GB/T 261, and JIS K 2265-3 |
| Applicable Standards | GB/T 261–2008, ASTM D93–22, JIS K 2265-3 |
| Display | Touchscreen LCD (Chinese interface) |
| Power Consumption | 800 W |
| Dimensions (W×D×H) | 400 × 380 × 350 mm |
| Weight | ~20 kg |
| Enclosure | Desktop, Stainless Steel Housing |
| Communication Interface | RS-232C |
| Data Output | Integrated Thermal Printer |
| Control Architecture | Microprocessor-Based with Self-Diagnostic Functionality |
| Brand | Xuxin Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | ST-1501 |
| Detection Method | Cleveland Open Cup (COC) |
| Operation Mode | Manual |
| Temperature Range | Ambient to 400 °C |
| Ignition Source | Adjustable Gas Flame |
| Repeatability | ≤4 °C |
| Compliant Standard | GB/T 3536-2008 |
| Accuracy | ±2 °C |
| Resolution | 1 °C |
| Heating Power | ≤600 W |
| Dimensions | 300 × 245 × 250 mm |
| Ambient Operating Conditions | 5–45 °C, 10–80% RH |
| Power Supply | 220 V ±10%, 50 Hz |
| Brand | Xuxin Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ST-151511 |
| Detection Method | Cleveland Open-Cup (COC) |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient to 400 °C |
| Ignition Methods | Intelligent Electric Ignition (standard), Gas Ignition (optional) |
| Repeatability | Compliant with GB/T 3536–2008 and ASTM D92 |
| Applicable Standards | GB/T 3536, GB/T 267, ASTM D92 |
| Accuracy | ±2 °C |
| Resolution | 0.1 °C |
| Display | Color LCD Touchscreen |
| Data Storage | 2000 test records with timestamp |
| Cooling | Integrated high-efficiency forced-air cooling |
| Power Consumption | ≤550 W |
| Dimensions | 430 × 280 × 285 mm |
| Weight | 16.5 kg |
| Environmental Operating Conditions | 5–45 °C, 10–80% RH |
| Power Supply | 220 V ±10%, 50 Hz |