| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINIFLASH FPA VISION |
| Detection Method | Closed-Cup (ASTM D93, ISO 2719, IP 34, EN ISO 3679) |
| Compatibility | Fully compatible with MINIFLASH FP VISION and FPH VISION analyzers |
| Sample Capacity | 12 positions |
| Footprint | 0.18 m² |
| Operating Temperature Range | –25 °C to 400 °C |
| Cooling Option | External liquid cooling interface for autosampler chamber |
| Power Supply | Switch-mode power supply (SMPS) |
| Software Platform | VISION Cockpit™ PC software (21 CFR Part 11 compliant audit trail, multi-user role management, networked data synchronization) |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MINIFLASH FPA VISION |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Power Supply | 100–264 VAC, 45–63 Hz, Max. 50 W |
| Dimensions (W×H×D) | 435 × 425 × 415 mm |
| Height with FP(H) VISION mounted | 530 mm |
| Weight | 15.9 kg (turntable: 2.2 kg |
| fully loaded turntable | 4.2 kg) |
| Cooling | External liquid cooling interface |
| Compliance | CE-marked per EN standards for laboratory instruments |
| Software Platform | VISION Platform with Cockpit™ PC software |
| Interface | Dedicated hardware interface to MINIFLASH FP/H VISION analyzers |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MiniFlash Touch FLP / FLPH |
| Temperature Range | 0–200°C (FLP) / 0–400°C (FLPH) |
| Sample Volume | 1–2 mL |
| Measurement Principle | Modified Continuously Closed Cup (MCCCFP) per ASTM D7094 |
| Compliance | ASTM D6450, ASTM D7094, ASTM D93, EN ISO 2719, EN ISO 3679, EN ISO 3680, ISO 13736, IP 170, ASTM D56 |
| Accuracy (Repeatability / Reproducibility) | ±3.8°C / ±5.4°C per ASTM D7094 |
| Ignition Source | High-energy electric arc |
| Cooling | Peltier-based active cooling (FLPH model supports external chiller) |
| Interfaces | USB 2.0, Ethernet (10/100 Mbps), LIMS-ready, PC-compatible |
| Software Platform | Microsoft® Windows®-based proprietary software with GLP-compliant audit trail |
| Data Storage | Unlimited method and result storage on internal SSD |
| Portability | 12 kg, 253 × 368 × 277 mm, 12 V DC vehicle power option |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HK-3011SK |
| Detection Method | Cleveland Open Cup (COC) Method |
| Temperature Range | Ambient to 400 °C |
| Accuracy | ±2 °C |
| Repeatability | ≤3 °C |
| Resolution | 0.1 °C |
| Heating Rate | 14–17 °C/min (from ambient to 56 °C below preset flash point) |
| Ignition | Automatic electronic ignition (silicon nitride igniter) |
| Cooling | Forced-air cooling |
| Power Consumption | ≤500 W |
| Data Storage | 1000 test records with date-based retrieval |
| Communication | RJ45 (LIMS integration), USB (firmware update & data export) |
| Power Supply | AC 170–264 V, 50/60 Hz or AC 120 V ±10%, 60 Hz ±1 Hz |
| Dimensions (Controller) | 270 × 170 × 130 mm, ~2.0 kg |
| (Testing Unit) | 480 × 245 × 280 mm, ~18.0 kg |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HK-3013SB |
| Detection Method | Closed Cup (ASTM D93 / ISO 2719 / GB/T 261) |
| Temperature Range | Ambient to 400 °C |
| Accuracy | ±1 °C (FP ≤ 110 °C), ±2 °C (FP > 110 °C) |
| Repeatability | 2 °C (FP ≤ 110 °C), 4 °C (FP > 110 °C) |
| Reproducibility | ≤10 °C |
| Resolution | 0.1 °C |
| Heating Rate | Step A: 5–6 °C/min |
| Step B | 1.0–1.5 °C/min |
| Ignition | Automatic electronic ignition (silicon nitride igniter) |
| Cooling | Forced-air cooling |
| Power Supply | AC (170–264) V, 50/60 Hz or AC (120±10%) V, 60±1 Hz (configurable at order) |
| Power Consumption | ≤300 W |
| Dimensions (Controller) | 270 × 170 × 130 mm, ~2.0 kg |
| (Test Unit) | 480 × 245 × 280 mm, ~18.0 kg |
| Data Storage | 1000 test records with date-based retrieval |
| Interfaces | RJ45 (LAN for LIMS integration & firmware update), USB (software update & data export) |
| Compliance | Designed to meet ASTM D93, ISO 2719, and GB/T 261 requirements for closed-cup flash point determination |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-FP1120 |
| Price Range | USD 150–15,000 |
| Test Method | Cleveland Open-Cup (COC) |
| Operation Mode | Manual |
| Temperature Range | Ambient to 400 °C |
| Ignition Method | Manual Flame Application |
| Repeatability | ≤4 °C |
| Applicable Standard | GB/T 3536 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Temperature Resolution | 0.1 °C |
| Reproducibility | ≤8 °C |
| Heating Rate | Compliant with GB/T 3536 Annex A |
| Brand | JIAHANG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HSY-3536D |
| Detection Method | Cleveland Open-Cup (COC) |
| Operation Mode | Fully Automatic |
| Applicable Standard | GB/T 3536–2008 |
| Repeatability | ≤8 °C (flash point and fire point) |
| Ignition Method | Electronic spark ignition |
| Temperature Range | Ambient to 400 °C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Display | 8-inch industrial true-color touchscreen (Windows CE OS, bilingual Chinese/English interface) |
| Temperature Sensor | Imported German PT1000 (resolution: 0.1 °C) |
| Microcontroller | Renesas MCU |
| Data Storage | 120 test records onboard |
| Safety Features | Auto-shutdown on overtemperature, flame-quenching lid for fire point, real-time millisecond-level flash detection |
| Environmental Operating Conditions | 10–40 °C, RH ≤80% |
| Power Consumption | ≤500 W |
| Dimensions (lowered/lifted) | 520 × 360 × 310 / 420 mm (L×W×H) |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K16591 |
| Test Method Compliance | ASTM D3278, D3828, D4206 |
| Temperature Range | –30°C to +300°C |
| Sample Volume | 2 mL |
| Test Duration | ~60 seconds |
| Cup Material | Anodized Aluminum |
| Configuration | Closed-Cup |
| Certification | CE, UL Listed |
| Regulatory Alignment | Supports GLP/GMP audit trails and 21 CFR Part 11-compliant data integrity workflows |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K27000 |
| Standards Compliance | ASTM D1322, ISO 3014 |
| Dimensions | 18 cm Ø × 47 cm H |
| Net Weight | 4.5 kg |
| Construction | Brass lamp body, copper-plated viewing window, adjustable aluminum base, calibrated 0–50 mm black glass scale, cotton wick assembly with air vent, candle socket |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | K47001 |
| Pricing | Upon Request |
| Test Method | Open-Cup |
| Operation Mode | Fully Automatic |
| Applicable Standard | ASTM E659 |
| Repeatability | ±5% |
| Ignition Mechanism | Fully Automated |
| Temperature Range | Ambient to 1200 °C |
| Temperature Control Accuracy | ±1 °C |
| Power Supply | 230 V, 50/60 Hz, Single-Phase, 7.7 A |
| Dimensions (W×D×H) | 37″ × 17″ × 25″ (94 cm × 43.2 cm × 63.5 cm) |
| Net Weight | 85 lb (38.6 kg) |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K71000 |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient to 405°C |
| Ignition Source | Switchable Gas or Electric Ignition |
| Applicable Standards | ASTM D93 Methods A, B & C, IP 34, ISO 2719, DIN EN 22719, JIS K2265, NF M 07-019 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K72000 |
| Detection Method | Cleveland Open Cup (COC) |
| Operation Mode | Fully Automated |
| Temperature Range | Ambient to 405°C |
| Ignition Sources | Electric Spark and Gas Flame |
| Repeatability | ±1°C |
| Compliant Standards | ASTM D92, GB/T 3536, IP 36/403, ISO 2592, AFNOR T60-118, EN 22592, DIN 51376 |
| Brand | KC Starlight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KS-9A |
| Price | USD 1,150 (FOB) |
| Temperature Range | 79 °C to 400 °C |
| Ignition Source | High-Stability Silicon Nitride Igniter |
| Repeatability | ≤4 °C |
| Applicable Standards | GB/T 3536, ASTM D92 |
| Accuracy | ±2 °C |
| Reproducibility | ≤8 °C |
| Heating Rate | Compliant with GB/T 3536 |
| Resolution | 0.1 °C |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH (non-condensing) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤550 W |
| Dimensions (W×D×H) | 410 × 320 × 165 mm |
| Net Weight | 14.5 kg |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | TAG 690 |
| Compliance | ASTM D56, D3278, D3934, D3941 |
| Temperature Range | –50 °C to +100 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Probe | PT100 Class A |
| Sample Cup | Copper, with level mark and heat-resistant handle |
| Heating System | Electronic heater with overtemperature protection |
| Cooling System | Liquid refrigerant controlled by internal solenoid valve |
| Ignition Mechanism | Automatic mechanical ignition switch per standard protocol |
| Dimensions (W×D×H) | 48 cm × 37 cm × 61 cm |
| Weight | 32 kg |
| Power Supply | 220 V ±15%, 50/60 Hz |
| Operating Environment | ≤35 °C, ≤80% RH |
| Safety Certification | CE |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MS200 |
| Sample Inlet Pressure Range (Liquid) | 0.69–2.75 MPa |
| Sample Inlet Pressure Range (Gas) | ≤2.07 MPa |
| Vaporization Temperature Control Range | Ambient to 150 °C |
| Transfer Line Heating Range | Ambient to 150 °C |
| Operating Ambient Temperature | –18 °C to +65 °C |
| Power Supply | 220 VAC, 50 Hz, max. 3.0 A |
| Dimensions (H×W×D) | 230 mm × 190 mm × 350 mm |
| Compliance | Designed for integration with GC and GC-MS systems in petroleum refining and hydrocarbon analysis labs |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 600-SA |
| Pricing | Available Upon Request |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | PLD-261A |
| Detection Method | Closed Cup (Tagliabue Cleveland Open Cup not applicable) |
| Standards Compliance | GB/T 261, ASTM D93 |
| Input Power | 1250 W |
| Supply Voltage | AC 220 V ±10%, 50 Hz |
| Max. Heating Power | 0–1200 W (continuously adjustable) |
| Ignition Gas Source | Coal gas, butane, or LPG |
| Stirring Motor | 6 W, 105 rpm |
| Stirring Speed | 105 rpm |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-3536A |
| Detection Method | Cleveland Open Cup (COC) |
| Input Power | 1250 W |
| Power Supply | AC 220 V / 50 Hz |
| Fuel Gas Options | Coal gas, butane, hydrogen, or LPG |
| Test Flame Ball Radius | 150 mm |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | PLD-3536D |
| Detection Method | Cleveland Open-Cup (COC) |
| Standards Compliance | GB/T 3536–2008, ASTM D92, ISO 2592 |
| Temperature Range | Ambient to 400 °C |
| Ignition Modes | Dual-mode (electronic spark + gas flame, selectable individually or simultaneously) |
| Control System | Dual-core CPU microcontroller |
| Display | 4.0-inch TFT LCD with touch-sensitive keypad |
| Cooling Method | Forced-air cooling |
| Atmospheric Pressure Compensation | Integrated digital barometric sensor with automatic calibration |
| Data Output | Thermal printer (built-in) |
| Software | PV Flash Point (Open) Test v8.0 |
| Flash Point Detector | PULL proprietary open-cup flash sensor |
| Power Supply | AC 220 V ±20 V, 50 Hz ±5 Hz |
| Rated Power | 500 W |
| Dimensions (W×D×H) | 310 × 395 × 303 mm |
| Safety Features | Auto-extinguishing, real-time fault diagnosis, thermal runaway protection, end-of-test forced cooldown |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | PLD-3536D |
| Detection Method | Cleveland Open-Cup (COC) |
| Standards Compliance | GB/T 3536–2008, ASTM D92, ISO 2592 |
| Temperature Range | Ambient to 400 °C |
| Ignition Modes | Dual-mode (electronic spark + gas flame, selectable individually or jointly) |
| Display | 4.0-inch TFT LCD with touch keypad |
| Cooling | Forced-air cooling |
| Atmospheric Pressure Compensation | Integrated digital barometric sensor with auto-calibration |
| Power Supply | AC 220 V ±20 V, 50 Hz ±5 Hz |
| Power Consumption | 500 W |
| Dimensions | 310 × 395 × 303 mm |
| Data Output | Thermal printer (built-in) |
| Control System | Dual-core microprocessor-based embedded controller |
| Software | PV Flash Point (Open) Test v8.0 |
| Safety Features | Auto-extinguishing after test completion, real-time fault diagnosis, overtemperature & flame-out protection, self-diagnostics |
| Origin | Switzerland |
|---|---|
| Standard Compliance | ASTM D3828, IP 303, ISO 3679 |
| Model | OilLab 620 |
| Temperature Range | −50 °C to +350 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Sensor Type | PT100 Class A |
| Sample Volume | ~4 mL |
| Heating System | Electronic with Over-Temperature Protection |
| Cooling Method | Forced-air fan cooling |
| Dimensions (W×D×H) | 31 × 47 × 52 cm |
| Weight | 27 kg |
| Power Supply | 220 V ±15 %, 50/60 Hz |
| Ambient Limits | ≤35 °C, ≤80 % RH |
| Safety Certification | CE |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 34200-0 |
| Test Method | Abel Equilibrium Cup Method |
| Temperature Range | Ambient to 93°C |
| Heating System | Electric heating plate |
| Cooling Options | Fan-cooled (45 min) or optional recirculating liquid cooling (3 min) |
| Ignition Sources | Selectable electronic or gas ignition |
| Temperature Sensor | Platinum resistance thermometer (Pt100) |
| Flash Detection | Ionization ring |
| Stirring Speed | 30 rpm |
| Power Supply | 110/120 V or 220/240 V, 50/60 Hz |
| Power Consumption | 600 W |
| Dimensions | 47 × 45 × 34 cm |
| Weight | 13 kg |
| Atmospheric Pressure Correction | Automatic |
| Compliance Standards | IP 170, IP 304 (obs) Part 2, IP 492, BS 2000-170, BS 3900-A8/A9, BS 6664-1&2, EN ISO 13736, ISO 1523 |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 34400-0 |
| Test Method | ASTM D56, D3934, D3941, E502 |
| Temperature Range | Ambient to 93 °C (standard), 5–93 °C (optional low-temperature configuration) |
| Heating System | Liquid-bath electric heating plate |
| Cooling Options | Fan-cooling (40 min cooldown), Compressed air or recirculating chiller (3 min cooldown, optional) |
| Ignition Sources | Selectable gas flame or electronic spark ignition |
| Temperature Sensor | Platinum resistance thermometer (Pt100) |
| Flash Detection | Ionization ring sensor |
| Stirring Speeds | 105 rpm and 250 rpm |
| Power Supply | 110/120 V or 220/240 V, 50/60 Hz |
| Power Consumption | 1 kW |
| Dimensions | 42 × 45 × 34 cm |
| Weight | 20 kg |
| Atmospheric Pressure Correction | Automatic |
| Data Storage | Last 5 test results retained internally |
| Compliance | Fully aligned with GLP/GMP data integrity expectations |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 34700-0 |
| Test Method | ASTM D3278, D3828, D7236, E502 |
| Temperature Range | Ambient to 300 °C (–10 °C to 300 °C with optional chiller) |
| Heating | Solid-block electric heater |
| Cooling | Fan-cooled (36 min) or optional compressed air / recirculating chiller (2 min) |
| Ignition | Selectable gas or electric spark ignition |
| Temperature Sensor | Platinum resistance thermometer (Pt100) |
| Flash Detection | Ionization ring |
| Stirring Speed | 30 rpm |
| Atmospheric Pressure Correction | Automatic |
| Power Supply | 110/120 V or 220/240 V, 50/60 Hz |
| Power Consumption | 1 kW |
| Dimensions | 34 × 47 × 42 cm |
| Weight | 20 kg |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 35300-0 |
| Test Method | Cleveland Open Cup (COC) |
| Automation Level | Fully Automatic |
| Ignition Sources | Interchangeable Gas and Electric Ignition |
| Safety Features | Motorized Lid Ejection, Integrated Fire Suppression, Rapid Cooling System |
| Enclosure | Integrated Draft Shield |
| Standards Compliance | ASTM D92, ASTM D8254, IP 36, ISO 2592, DIN 51376, NF T60-118, JIS K 2265-4, AASHTO T48, GB/T 3536 |
| Data Interface | USB, LIMS-compatible, QR Code Export |
| Storage | High-capacity Internal Memory |
| Software | QC-Ready with Audit Trail, ISO/IEC 17025 Method Validation Support |
| Maintenance | Tool-free Component Access, Quick-Clean Crucible Assembly |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 35000-0 |
| Test Method | Closed-Cup (Pensky-Martens) |
| Temperature Range | +5 °C to 400 °C |
| Temperature Resolution | ±0.1 °C |
| Heating Rates | 1.0, 1.3, 3.0, 5.5 °C/min (standard) |
| Stirring Speed | 105 or 250 rpm |
| Ignition Options | Electric spark or gas flame (user-selectable in menu) |
| Atmospheric Pressure Correction | Integrated digital barometer with automatic flash point compensation |
| Display | 8.4-inch color touchscreen (Chinese UI) |
| Data Storage | ≥2000 test records, 30 programmable methods |
| Connectivity | Ethernet and RS-232 |
| Dimensions | 38.5 × 24 × 50 cm |
| Weight | 25 kg |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 82000-2 |
| Test Method | Closed-Cup (Rapid Equilibrium / Constant Rate of Rise) |
| Automation Level | Fully Automatic |
| Temperature Range | −20 °C to 130 °C or Ambient +5 °C to 300 °C |
| Sample Volume | 2–4 mL |
| Ignition Source | Selectable Electric Spark or Gas Flame |
| Compliance | ASTM D3278, D3828, D7236 |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | SETAFLASH Series 3 |
| Detection Method | Closed-Cup |
| Temperature Range | 0 °C to 300 °C |
| Ignition Mode | Electric or Gas Ignition |
| Compliance Standards | ISO 3679 |
| Sample Volume | 2 mL (for samples with expected flash point ≤100 °C), 4 mL (for >100 °C) |
| Cooling Time | ≤4 min (from 80 °C to 20 °C, optional) |
| Test Duration | 1–99 min |
| Interface Options | RS232, USB, LAN |
| Power | 200 W / 300 W |
| Voltage | 100–250 V AC, 50/60 Hz |
| Cup Materials | Anodized Aluminum, Corrosion-Resistant Stainless Steel |
| Brand | Shenkai |
|---|---|
| Model | SKY1001-II |
| Test Method | Cleveland Open Cup (COC) |
| Standards Compliance | ASTM D92, GB/T 3536, ISO 2592, IP 36 |
| Temperature Range | 79–400 °C |
| Display Resolution | 0.1 °C |
| Repeatability | ≤6 °C |
| Reproducibility | ≤8 °C |
| Safety Cutoff Temperatures | EFP+20 °C (Flash), EFP+50 °C (Fire), Absolute Limit: 400 °C |
| Heating Power | 800 W |
| Total Power | 900 W |
| Supply | AC 220 V ±10%, 50/60 Hz |
| Dimensions | 233 × 530 × 427 mm (W×D×H) |
| Weight | 19 kg |
| Cooling | Forced-air |
| Ignition Detection | Ionization flame sensing |
| Pressure Requirement for Fuel Gas | <10 kPa (LPG, butane, natural gas, or town gas) |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SKY1002-II |
| Operation | Fully Automatic |
| Compliant Standards | ASTM D93, GB/T 261, ISO 2719, IP 34 |
| Flash Point Range | 40–370 °C |
| Temperature Display Resolution | 0.1 °C |
| Heating Rates | Step A: 5–6 °C/min |
| Step B | 1.0–1.5 °C/min |
| Step C | 2.5–3.5 °C/min |
| Stirring Speeds | Step A: 90–120 r/min |
| Step B | 250 ±10 r/min |
| Step C | 90–120 r/min |
| Ignition Modes | Electronic or Gas (LPG, butane, natural gas <10 kPa) |
| Safety Cut-off | EFP+20 °C (flash mode), absolute limit 400 °C |
| Cooling | High-efficiency forced-air system |
| Data Interface | RJ-45 for LIMS integration |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 525 × 365 mm |
| Net Weight | 20 kg |