Gas Permeability Tester
Filter
Showing 91–120 of 152 results
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Jinan Labthink Electromechanical Technology Co., Ltd. |
| Model | C106H |
| Test Principle | Differential-pressure (manometric) method |
| Standards Compliance | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB 00082003 |
| Test Gases | O₂, N₂, CO₂ (user-supplied), optional H₂/CH₄ (custom) |
| Temperature Range | 15–50 °C (standard) |
| Humidity Range | 0% RH (dry), or 5–90% ±2% RH (optional) |
| Vacuum Capability | ≤10 Pa test chamber |
| Pressure Control | 10–150 kPa adjustable high-pressure cavity |
| Test Area | 38.48 cm² per chamber |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Sample Thickness | 3 mm |
| OTR Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Resolution | 0.01 °C |
| Temp. Uniformity | ±0.15 °C |
| Vacuum Sensor Accuracy | ±0.2% of reading (1–100% FS) |
| Chambers | 6 independent, parallel test stations |
| Automation | Motorized sample clamping, auto lid actuation, vacuum pump sequencing, real-time pressure compensation |
| Control Interface | 12″ Windows-based touch panel |
| Data Output | OTR curves, permeability coefficient (P), diffusion coefficient (D), solubility coefficient (S), temperature profiles |
| Optional Compliance Packages | 21 CFR Part 11, GMP-compliant audit trail, DataShield™ secure data integrity module |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Labthink International Co., Ltd. |
| Model | C106H |
| Test Principle | Differential Pressure (ASTM D1434 / ISO 2556 / GB/T 1038) |
| Test Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 15–50 °C (5–60 °C optional) |
| Temp. Stability | ±0.15 °C |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Test Chamber Vacuum Level | ≤10 Pa |
| Number of Test Cells | 6 independent chambers |
| Standard Test Area | 38.48 cm² |
| Max. Sample Thickness | 3 mm |
| Pressure Control Range | 10–150 kPa |
| Pressure Stability | ±0.2 kPa |
| Supported Gases | O₂, N₂, CO₂ (H₂/CH₄ available on custom configuration) |
| Power Supply | 120 VAC ±10%, 60 Hz or 220 VAC ±10%, 50 Hz |
| Dimensions (W×D×H) | 600 × 490 × 660 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C106H |
| Price Range | USD 14,000 – 98,000 |
| Test Principle | Differential Pressure (Manometric) Method |
| Test Gases | O₂, N₂, CO₂ (H₂, CH₄ optional on customization) |
| Test Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 15–50 °C (5–60 °C optional) |
| Temp. Stability | ±0.15 °C |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Min. Chamber Vacuum | ≤10 Pa |
| Test Area | 38.48 cm² (11.2 cm × 11.2 cm sample) |
| Max. Sample Thickness | 3 mm |
| Test Pressure Range | 10–150 kPa (adjustable, ΔP stability <0.2 kPa) |
| Chamber Count | 6 independent test stations |
| Power Supply | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz |
| Net Weight | 100 kg |
| Dimensions | 600 × 490 × 660 mm |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | C106H |
| Price Range | USD 14,000 – 115,000 |
| Test Principle | Differential Pressure (Manometric) Method |
| Standards Compliance | ISO 15105-1, ISO 2556, GB/T 1038-2000, ASTM D1434, JIS K7126-1, YBB 00082003 |
| Test Gases | O₂, N₂, CO₂ (user-supplied) |
| Temperature Range | 15–50 °C (standard), 5–60 °C (optional) |
| Humidity Range | 0% RH (dry), 5–90% ±2% RH (optional) |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Test Chamber Vacuum Level | ≤10 Pa |
| Test Area | 38.48 cm² per chamber |
| Sample Size | 11.2 cm × 11.2 cm |
| Max Sample Thickness | 3 mm |
| Test Pressure Range | 10–150 kPa (adjustable) |
| Pressure Stability | ±0.2 kPa |
| Gas Transmission Rate (GTR) Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| GTR Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Uniformity | ±0.15 °C |
| Chamber Configuration | 6 independent test chambers |
| Data Output | Permeability Coefficient (P), Diffusion Coefficient (D), Solubility Coefficient (S), GTR curves, P vs. T plots, real-time pressure/temperature logging |
| Software Features | CFR 21 Part 11 compliance package (optional), audit trail, user permission levels, electronic signatures, raw data export (CSV, PDF, XML) |
| Control Interface | 12-inch Windows-based touch tablet |
| Automation | Auto-clamping, auto-vacuum control, auto-pressure compensation, motorized lid actuation with audio-visual alert |
| Vacuum Pump | Imported high-vacuum pump, ultimate vacuum ≤0.2 Pa |
| Pneumatic System | Imported solenoid valves & actuators, MTBF >100,000 cycles |
| Thermal Management | 360° circumferential air-circulation heating, PID-controlled uniformity |
| Power Supply | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz (selectable) |
| Net Weight | 100 kg |
| Dimensions | 600 × 490 × 660 mm (W × D × H) |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | C106H Gas Permeation Analyzer |
| Price Range | USD 14,000 – 98,000 |
| Test Principle | Differential Pressure Method (ISO 15105-1, ASTM D1434, GB/T 1038-2000) |
| Test Gases | O₂, N₂, CO₂ |
| Measurement Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 15–50 °C (5–60 °C optional) |
| Temp. Stability | ±0.15 °C |
| Vacuum Capability | ≤10 Pa (Resolution: 0.01 Pa |
| Accuracy | ±0.2% of reading in 1–100% sensor span) |
| Test Area | 38.48 cm² |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Sample Thickness | 3 mm |
| Test Pressure Range | 10–150 kPa (adjustable |
| pressure stability | ±0.2 kPa) |
| Humidity Control | 0% RH or 5–90% ±2% RH (customizable) |
| Power Supply | 120 VAC ±10%, 60 Hz / 220 VAC ±10%, 50 Hz (selectable) |
| Dimensions | 600 × 490 × 660 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Model | C106H |
| Principle | Differential Pressure Method (ISO 15105-1, ASTM D1434) |
| Test Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 15–50 °C (5–60 °C optional) |
| Temp. Stability | ±0.15 °C |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Test Chamber Vacuum Level | ≤10 Pa |
| Chamber Count | 6 independent cavities |
| Standard Test Area | 38.48 cm² |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Sample Thickness | 3 mm |
| Test Gases | O₂, N₂, CO₂ (H₂/CH₄ available on custom configuration) |
| Test Pressure | 10–150 kPa (adjustable, ΔP stability <0.2 kPa) |
| Power Supply | 120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz |
| Net Weight | 100 kg |
| Dimensions | 600 × 490 × 660 mm |
| Brand | Labthink |
|---|---|
| Model | C106H |
| Test Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 15–50 °C (standard), 5–60 °C (optional) |
| Temp. Resolution | 0.01 °C |
| Temp. Stability | ±0.15 °C |
| Humidity Range | 0% RH, or 5–90% ±2% RH (customizable) |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Test Chamber Vacuum Level | ≤10 Pa |
| Test Cells | 6 independent chambers |
| Sample Size | 11.2 cm × 11.2 cm (4.4″ × 4.4″) |
| Max. Sample Thickness | 3 mm (120 mil) |
| Standard Test Area | 38.48 cm² |
| Test Gases | O₂, N₂, CO₂ (gas supply not included) |
| Test Pressure | 10–150 kPa (adjustable) |
| Pressure Stability | ±0.2 kPa |
| Gas Inlet Pressure | 550 kPa (79.7 PSI) |
| Tubing Interface | Φ6 mm polyurethane |
| Dimensions | 600 mm × 490 mm × 660 mm |
| Power Supply | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz (user-selectable) |
| Net Weight | 100 kg (220 lbs) |
| Brand | Labthink |
|---|---|
| Model | C106H |
| Measurement Principle | Differential Pressure Method (ASTM D1434, ISO 15105-1, GB/T 1038-2000) |
| Test Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 15–50 °C (optional 5–60 °C) |
| Temp. Stability | ±0.15 °C |
| Vacuum Resolution | 0.01 Pa |
| Min. Detectable Permeation | 0.01 cm³/m²·24h·0.1MPa |
| Test Chambers | 6 independent chambers |
| Sample Area | 38.48 cm² |
| Max. Sample Thickness | 3 mm |
| Pressure Control Range | 10–150 kPa |
| Pressure Stability | ±0.2 kPa |
| Vacuum Level | ≤10 Pa (pump limit: 0.2 Pa) |
| Power Supply | 120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz |
| Net Weight | 100 kg |
| Dimensions | 600 × 490 × 660 mm |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C106H |
| Price Range | USD 14,000 – 98,000 |
| Test Principle | Differential Pressure Method (ISO 15105-1, ASTM D1434, GB/T 1038-2000) |
| Test Gases | He, O₂, N₂, CO₂, CH₄ (customizable) |
| Temperature Range | 15–50 °C (standard) |
| Humidity Range | 0% RH (dry), or 5–90% ±2% RH (optional) |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Test Chamber Vacuum Level | ≤10 Pa |
| Permeability Range | 0.01–50,000 cm³/(m²·24h·0.1MPa) |
| Resolution | 0.001 cm³/(m²·24h·0.1MPa) |
| Temperature Stability | ±0.15 °C |
| Test Area | 38.48 cm² per chamber |
| Sample Size | 11.2 cm × 11.2 cm |
| Max Sample Thickness | 3 mm |
| Number of Test Chambers | 6 independent |
| Pressure Control Range | 10–150 kPa (adjustable) |
| Pressure Stability | ±0.2 kPa |
| Gas Inlet | Φ6 mm polyurethane tubing |
| Power Supply | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz |
| Net Weight | 100 kg |
| Dimensions | 600 mm × 490 mm × 660 mm |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | C106H |
| Test Principle | Differential Pressure Method (Manometric) |
| Measurement Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 15–50 °C (5–60 °C optional) |
| Temp. Stability | ±0.15 °C |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Test Chamber Vacuum Level | ≤10 Pa |
| Chamber Count | 6 independent cavities |
| Standard Test Area | 38.48 cm² |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Sample Thickness | 3 mm |
| Test Gas Compatibility | H₂, CH₄, O₂, N₂, CO₂ (custom-configured for flammable gases) |
| Pressure Control Range | 10–150 kPa (adjustable, stability ±0.2 kPa) |
| Power Supply | 120 VAC±10% 60 Hz / 220 VAC±10% 50 Hz |
| Net Weight | 100 kg |
| Compliance | ISO 15105-1, ISO 2556, GB/T 1038-2000, ASTM D1434, JIS K7126-1, YBB 00082003 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | C106H |
| Price Range | USD 14,000 – 72,000 |
| Testing Principle | Differential-Pressure (Manometric) Method |
| Standards Compliance | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB 00082003 |
| Test Gases | O₂, N₂, CO₂, H₂ (customizable), CH₄ (customizable) |
| Temperature Range | 15–50 °C (standard) |
| Humidity Range | 0% RH (dry), 5–90% ±2% RH (optional) |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Test Chamber Vacuum Level | ≤10 Pa |
| Number of Test Chambers | 6 independent chambers |
| Sample Area | 38.48 cm² (11.2 cm × 11.2 cm) |
| Max. Sample Thickness | 3 mm |
| Pressure Range (High-Pressure Side) | 10–150 kPa (adjustable) |
| Pressure Stability | ±0.2 kPa |
| Gas Transmission Rate (GTR) Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| GTR Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Resolution | 0.01 °C |
| Temperature Uniformity | ±0.15 °C |
| Power Supply | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz (user-selectable) |
| Net Weight | 100 kg |
| Dimensions | 600 × 490 × 660 mm |
| Control Interface | 12-inch Windows-based touch panel |
| Optional Compliance Modules | FDA 21 CFR Part 11, GMP-compliant audit trail, DataShield™ data integrity package |
| Brand | Labthink |
|---|---|
| Model | C106H |
| Principle | Differential Pressure Method (ASTM D1434, ISO 15105-1, GB/T 1038-2000) |
| Test Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 15–50 °C (5–60 °C optional) |
| Temp. Stability | ±0.15 °C |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Test Chamber Vacuum Level | ≤10 Pa |
| Chamber Count | 6 independent chambers |
| Standard Test Area | 38.48 cm² |
| Max. Sample Thickness | 3 mm |
| Pressure Control Range | 10–150 kPa |
| Pressure Stability | ±0.2 kPa |
| Gas Options | O₂, N₂, CO₂ (H₂, CH₄ available on custom configuration) |
| Power Supply | 120 VAC ±10%, 60 Hz or 220 VAC ±10%, 50 Hz |
| Net Weight | 100 kg |
| Dimensions | 600 × 490 × 660 mm |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C130H |
| Price Range | USD 14,000 – 85,000 |
| Test Principle | Differential-Pressure (Manometric) Method |
| Standards Compliance | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB 00082003 |
| Measurement Range | 0.01–50,000 cm³/(m²·24h·0.1MPa) |
| Resolution | 0.001 cm³/(m²·24h·0.1MPa) |
| Temperature Range | 10–50 °C (ambient reference 23 °C) |
| Temp. Stability | ±0.05 °C |
| Temp. Accuracy | ±0.3 °C (at calibration port) |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Chamber Vacuum Level | <10 Pa |
| Specimen Quantity | 3 independent test chambers |
| Specimen Diameter | Φ97 mm |
| Effective Test Area | 38.48 cm² |
| Test Gases | O₂, N₂, CO₂, air, He (custom configurations available for flammable, explosive or toxic gases) |
| Test Pressure Range | 10–210 kPa (adjustable) |
| Gas Supply Pressure | 0.5–0.6 MPa |
| Power Supply | 220 VAC ±10%, 50 Hz OR 120 VAC ±10%, 60 Hz |
| Dimensions (L×W×H) | 710 × 350 × 630 mm |
| Net Weight | ~100 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Model | C130H |
| Test Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 10–50 °C (±0.05 °C stability) |
| Vacuum Capability | <10 Pa (sensor resolution 0.01 Pa |
| Test Pressure Range | 10–210 kPa (adjustable) |
| Sample Capacity | 3 independent test chambers (Φ97 mm, 38.48 cm² effective area) |
| Power Supply | 220 VAC ±10% 50 Hz or 120 VAC ±10% 60 Hz |
| Net Weight | ~100 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C130H-Labthink |
| Price Range | USD 14,000 – 70,000 |
| Test Principle | Differential Pressure Method (ISO 15105-1, ISO 2556, GB/T 1038-2000, ASTM D1434, JIS K7126-1, YBB 00082003) |
| Measurement Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Test Temperature | 10–50 °C (±0.05 °C stability, ±0.3 °C accuracy via calibration port) |
| Vacuum Capability | <10 Pa chamber vacuum, sensor resolution 0.01 Pa, accuracy ±0.2% of reading (1–100% of sensor span) |
| Test Pressure Range | 10–210 kPa (adjustable, pressure drift <0.2 kPa during test) |
| Specimen Size | Ø97 mm |
| Effective Test Area | 38.48 cm² |
| Specimen Capacity | 3 independent test chambers |
| Gas Compatibility | O₂, N₂, CO₂, He, air, and custom hazardous or humidified gases (optional modules) |
| Power Supply | 220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz |
| Dimensions | 710 × 350 × 630 mm (L×W×H) |
| Net Weight | ~100 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C130H |
| Price Range | USD 14,000 – 85,000 |
| Test Principle | Differential Pressure Method (Manometric) |
| Standards Compliance | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB 00082003 |
| Measurement Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 10–50 °C (ambient 23 °C) |
| Temp. Stability | ±0.05 °C |
| Temp. Accuracy | ±0.3 °C (via calibration port) |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Max. Test Chamber Vacuum | <10 Pa |
| Sample Quantity | 3 independent test cells |
| Sample Diameter | Φ97 mm |
| Effective Test Area | 38.48 cm² |
| Test Gases | O₂, N₂, CO₂, air, He (custom configurations available for flammable, explosive or toxic gases) |
| Test Pressure Range | 10–210 kPa (adjustable) |
| Gas Supply Pressure | 0.5–0.6 MPa |
| Power Supply | 220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz (user-selectable) |
| Dimensions (L×W×H) | 710 × 350 × 630 mm |
| Net Weight | ~100 kg |
| Brand | Labthink |
|---|---|
| Model | C130H |
| Principle | Differential Pressure Method (Manometric) |
| Test Gases | O₂, N₂, CO₂ (customizable for mixed/inflammable gases) |
| Temperature Range | 10–50 °C (±0.05 °C stability) |
| Pressure Range | 10–210 kPa (adjustable high-side pressure) |
| Vacuum Capability | <10 Pa base pressure, 0.2 Pa ultimate vacuum |
| Measurement Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Sample Size | Φ97 mm (38.48 cm² effective area) |
| Chambers | 3 independent test stations |
| Compliance | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB 00082003 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | C130H |
| Price Range | USD 14,000 – 98,000 |
| Testing Principle | Differential Pressure Method (ISO 15105-1, ASTM D1434, GB/T 1038-2000) |
| Test Gases | O₂, N₂, CO₂ (customizable for mixed or hazardous gases) |
| Temperature Range | 10–50 °C (±0.05 °C stability) |
| Pressure Range | 10–210 kPa (adjustable high-side pressure) |
| Vacuum Capability | <10 Pa chamber vacuum |
| Measurement Range | 0.01–50,000 cm³/(m²·24h·0.1MPa) |
| Resolution | 0.001 cm³/(m²·24h·0.1MPa) |
| Sample Capacity | 3 independent test chambers (Φ97 mm, 38.48 cm² effective area) |
| Compliance | ISO 2556, JIS K7126-1, YBB 00082003, GLP/GMP-ready (optional DataShield™ & 21 CFR Part 11 support) |
| Brand | Labthink |
|---|---|
| Model | C130H |
| Measurement Principle | Differential Pressure (ASTM D1434 / ISO 15105-1) |
| Test Gases | O₂, N₂, CO₂, Air, He (customizable for flammable/toxic gases) |
| Test Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 10–50 °C (±0.05 °C stability) |
| Vacuum Capability | <10 Pa base pressure, 0.01 Pa resolution |
| Pressure Control | 10–210 kPa (adjustable, ±0.2 kPa stability) |
| Sample Capacity | 3 independent chambers (Φ97 mm, 38.48 cm² effective area) |
| Compliance | GB/T 1038–2000, ISO 2556, JIS K7126-1, YBB 00082003, FDA 21 CFR Part 11 (optional), GMP Annex 11 (optional) |
| Brand | Labthink |
|---|---|
| Model | C190H |
| Measurement Principle | Volumetric Method (Air Flow Time per 100 mL) |
| Test Range | 30–1500 s/100 mL |
| Volume Resolution | 0.001 mL |
| Volume Accuracy | ±1% |
| Pressure Range | 0–2 kPa |
| Pressure Control Accuracy | ±0.01 kPa |
| Test Area | 6.45 cm² (1 in²) |
| Sample Size | ≥60 mm × 60 mm |
| Max Sample Thickness | 3 mm |
| Touchscreen Control | 12" Windows-based Industrial Tablet |
| Environmental Monitoring | Integrated Temp & RH Sensors |
| Compliance Standards | ISO 5636, TAPPI T460, GB/T 36363-2018, GB/T 458-2008, GB/T 23227, GB/T 12655 |
| Optional | 21 CFR Part 11 Audit Trail, GMP Validation Support, DataShield™ Secure Data Management |
| Brand | Labthink |
|---|---|
| Model | C190H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 14,000 – 70,000 |
| Testing Principle | Volumetric Method (Air Volume Displacement under Constant Pressure) |
| Test Range | 30–1500 s/100 mL |
| Volume Resolution | 0.001 mL |
| Volume Accuracy | ±1% |
| Pressure Range | 0–2 kPa |
| Pressure Control Precision | ±0.01 kPa |
| Test Area | 6.45 cm² (1 in²) |
| Sample Size | ≥60 mm × 60 mm |
| Max Sample Thickness | 3 mm |
| Environmental Monitoring | Auto-detect & Log Temperature/Humidity |
| Unit Options | s/100 mL, µm/(Pa·s), mL/min, etc. |
| Compliance Standards | ISO 5636, TAPPI T460, GB/T 36363-2018, GB/T 458-2008, GB/T 23227, GB/T 12655 |
| Optional Features | CFR 21 Part 11 Compliance Module, GMP Computer System Validation Support, DataShield™ Data Integrity Package |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | C230H |
| Price Range | USD 14,000 – 85,000 |
| Test Principle | Coulometric Oxygen Sensor + Isostatic (Equal-Pressure) Method |
| Standards Compliance | ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015 |
| Test Range | 0.01–200 cm³/(m²·day) (film) |
| Resolution | 0.001 cm³/(m²·day) |
| Repeatability | ±0.01 cm³/(m²·day) or ±2% (whichever is greater) |
| Test Temperature | 10–55 °C ±0.2 °C |
| Test Humidity | 0% RH, 5–90% RH ±1% RH, 100% RH |
| Chamber Count | 3 |
| Sample Size | 108 mm × 108 mm |
| Max Sample Thickness | ≤3 mm |
| Standard Test Area | 50 cm² |
| Carrier Gas | ≥99.999% high-purity N₂ (user-supplied) |
| Inlet Pressure | ≥0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Optional Modules | Package Testing (up to 3 L), DataShield™ Data Integrity System, CFR 21 Part 11 Compliance Package, GMP Computer System Validation Support |
| Brand | Labthink |
|---|---|
| Model | C403H |
| Origin | Shandong, China |
| Manufacturer | Jinan Labthink Electromechanical Technology Co., Ltd. |
| Test Principle | Coulometric Oxygen Sensor + Infrared Moisture Sensor |
| Standards Compliance | ASTM D3985, ASTM F1249, ISO 15106-2, GB/T 19789, GB/T 26253, YBB 00082003-2015, YBB 00092003-2015 |
| OTR Range | 0.01–200 cc/(m²·day) (50 cm²), 0.2–2000 cc/(m²·day) (5 cm² mask, optional), 1–10000 cc/(m²·day) (1 cm² mask, optional) |
| WVTR Range | 0.005–40 g/(m²·day) (50 cm²), 0.2–400 g/(m²·day) (5 cm² mask, optional), 1–2000 g/(m²·day) (1 cm² mask, optional) |
| OTR Resolution | 0.0001 cc/(m²·day) |
| WVTR Resolution | 0.0001 g/(m²·day) |
| OTR Repeatability | ±0.01 cc/(m²·day) or ±1%, whichever is greater |
| WVTR Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 15–50 °C (standard), 5–60 °C (customizable) |
| RH Control | 0–90 %RH ±2 %RH |
| Test Chambers | 3 independent 50 cm² chambers |
| Sample Size | 11.2 cm × 11.2 cm |
| Max Sample Thickness | 3 mm |
| Carrier Gas | ≥99.999% N₂ (for detection), ≥99.5% O₂ (for OTR test gas) |
| Power Supply | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz |
| Dimensions | 60 × 50 × 70 cm (W×D×H) |
| Net Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Model | CLASSIC 216 |
| Measurement Principle | Differential Pressure (Manometric) Method |
| Test Gases | O₂, N₂, CO₂, Air, He |
| Test Range | 0.1–50,000 cm³/m²·24h·0.1 MPa (standard) |
| Number of Independent Test Cells | 3 |
| Vacuum Resolution | 0.1 Pa |
| Minimum Test Chamber Vacuum | <20 Pa |
| Temperature Control Range | 15–55 °C (external chiller/heater required for precise isothermal operation) |
| Humidity Control Options | 0% RH, 100% RH, or intermediate levels per ASTM E104 (humidification system optional) |
| Specimen Area | 38.48 cm² (Ø97 mm) |
| Pressure Differential Range | –0.1 to +0.1 MPa |
| Supply Gas Pressure | 0.4–0.6 MPa |
| Power Supply | AC 220 V / 50 Hz or AC 120 V / 60 Hz |
| Dimensions (L×W×H) | 670 × 540 × 430 mm |
| Net Weight | 75 kg |
| Compliance | ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, GB/T 1038–2000, YBB 00082003–2015 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CLASSIC 216 |
| Price Range | USD 14,000 – 57,000 |
| Test Principle | Differential-Pressure (Manometric) Method |
| Standards Compliance | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB 00082003-2015 |
| Test Gases | O₂, N₂, CO₂, He, air |
| Measurement Range | 0.1–50,000 cm³/m²·24h·0.1 MPa (standard) |
| Number of Test Cells | 3 (independent) |
| Vacuum Resolution | 0.1 Pa |
| Chamber Vacuum Level | <20 Pa |
| Temperature Control Range | 15–55 °C (external chiller/heater required) |
| Humidity Control Options | 0% RH, 100% RH, or intermediate levels per ASTM E104 (humidity generator optional) |
| Specimen Diameter | Φ97 mm |
| Effective Test Area | 38.48 cm² |
| Test Pressure Differential | −0.1 to +0.1 MPa |
| Supply Gas Pressure | 0.4–0.6 MPa |
| Tubing Interface | Φ6 mm polyurethane |
| Dimensions (L×W×H) | 670 × 540 × 430 mm |
| Weight | 75 kg |
| Power Supply | AC 220 V / 50 Hz or AC 120 V / 60 Hz |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CLASSIC 216 |
| Test Principle | Differential-Pressure (Manometric) Method |
| Measurement Range | 0.1–50,000 cm³/m²·24h·0.1MPa (standard) |
| Test Stations | 3 independent chambers |
| Vacuum Resolution | 0.1 Pa |
| Chamber Vacuum Level | <20 Pa |
| Temperature Control Range | 15–55 °C (external chiller/heater required) |
| Humidity Control Options | 0% RH, 100% RH, or intermediate levels per ASTM E104 (humidification module optional) |
| Specimen Area | 38.48 cm² (Φ97 mm) |
| Test Gases | O₂, N₂, CO₂, air, He (user-supplied gas sources, 0.4–0.6 MPa inlet pressure) |
| Pressure Differential | –0.1 to +0.1 MPa |
| Power Supply | AC 220 V 50 Hz / AC 120 V 60 Hz |
| Dimensions | 670 × 540 × 430 mm (L×W×H) |
| Net Weight | 75 kg |
| Compliance Standards | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB 00082003-2015 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | CLASSIC216 |
| Price Range | USD 14,000 – 85,000 |
| Test Gases | O₂, CO₂, N₂, Air, He, H₂, CH₄ |
| Test Range | 0.1–50,000 cm³/m²·24h·0.1MPa (standard) |
| Specimen Count | 3 independent chambers |
| Vacuum Resolution | 0.1 Pa |
| Chamber Vacuum Level | <20 Pa |
| Temperature Control Range | 15–55 °C (external chiller/heater required) |
| Humidity Control Options | 0% RH, 100% RH, or intermediate levels per ASTM E104 (humidity generator optional) |
| Specimen Diameter | Φ97 mm |
| Effective Test Area | 38.48 cm² |
| Test Pressure Differential | −0.1 to +0.1 MPa |
| Supply Gas Pressure | 0.4–0.6 MPa |
| Interface | Φ6 mm polyurethane tubing |
| Dimensions | 670 × 540 × 430 mm (L×W×H) |
| Weight | 75 kg |
| Power | AC 220 V / 50 Hz or AC 120 V / 60 Hz |
| Brand | Labthink |
|---|---|
| Model | CLASSICA-216 |
| Principle | Differential Pressure (Manometric) Method |
| Test Gases | O₂, N₂, CO₂, Air, He |
| Test Range | 0.1–50,000 cm³/m²·24h·0.1 MPa (standard) |
| Vacuum Resolution | 0.1 Pa |
| Chamber Vacuum Level | <20 Pa |
| Temperature Control Range | 15–55 °C (external chiller/heater required) |
| Humidity Control Options | 0% RH, 100% RH, or intermediate levels per ASTM E104 (humidity generator optional) |
| Specimen Area | 38.48 cm² |
| Specimen Diameter | Φ97 mm |
| Pressure Range | −0.1 to +0.1 MPa |
| Supply Gas Pressure | 0.4–0.6 MPa |
| Interface | Φ6 mm polyurethane tubing |
| Dimensions | 670 × 540 × 430 mm (L×W×H) |
| Weight | 75 kg |
| Power | AC 220 V / 50 Hz or AC 120 V / 60 Hz |
| Standards Compliance | ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, GB/T 1038–2000, YBB 00082003–2015 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Jinan Labthink Electromechanical Technology Co., Ltd. |
| Model | TQD-G1A |
| Pressure Drop Range | 0–1000 Pa |
| Pressure Resolution | 0.1 Pa |
| Pressure Accuracy | ±0.25% FS |
| Flow Rate Range | 0–30 L/min |
| Flow Resolution | 0.1 L/min |
| Flow Accuracy | ±2% FS |
| Test Area | 20 cm² (standard, customizable) |
| Sample Size | 5 cm × 5 cm |
| Max Sample Thickness | 1 mm |
| Gas Supply | Clean compressed air (user-supplied, ≥550 kPa, >120 L/min) |
| Power | 120 VAC ±10% / 60 Hz or 220 VAC ±10% / 50 Hz |
| Dimensions | 300 mm × 460 mm × 520 mm |
| Weight | 25 kg |
| Interface | RS232 (optional software integration) |
| Display | 7" industrial color touchscreen |
| Compliance | ISO 9237, ISO 4638, ISO 5636, GB/T 5453, GB/T 10655, GB/T 4689.22, GB/T 13764, ASTM D737, TAPPI T460, JIS P8117 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PERME博密 VAC-V2 |
| Price Range | USD 14,000 – 85,000 (FOB Qingdao) |
| Test Principle | Differential Pressure (Manometric) Method |
| Standards Compliance | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB 00082003 |
| Test Gases | O₂, N₂, CO₂, Air, He (including flammable/explosive gases with optional safety retrofit) |
| Temperature Control | 5–95 °C (±0.1 °C) |
| Humidity Control | 0%RH, 2–98.5%RH, 100%RH (external humidity generator required) |
| Vacuum Resolution | 0.1 Pa |
| Test Chamber Vacuum Level | <20 Pa |
| Sample Area | 38.48 cm² |
| Sample Diameter | Φ97 mm |
| Test Range | 0.05–50,000 cm³/m²·24h·0.1MPa (standard) |
| Independent Test Cells | 3 |
| Power Supply | 220VAC 50Hz / 120VAC 60Hz |
| Net Weight | 88 kg |
| Dimensions | 760 × 575 × 450 mm (L×W×H) |
| Interface | RS232, Lystem™ Lab Data Management System compatible |