Headspace Sampler
Filter
Showing 91–120 of 186 results
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | AHS-610 + GC-2010 |
| Instrument Type | Static Headspace Sampler |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Semi-Automatic |
| Sample Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve & Transfer Line Temperature Control Range | Ambient to 160 °C (1 °C increments) |
| Quantitative Loop Volume | 1 mL |
| Vial Capacity | 9 positions |
| Vial Standard Size | 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Vial Heating Range | Ambient to 200 °C |
| Valve & Transfer Line Temperature Control Range | Ambient to 180 °C |
| Sample Loop Volume Options | 1 mL or 3 mL (selectable) |
| Vial Capacity | 9 positions |
| Compatible Vial Sizes | 10 mL and 20 mL standard (custom sizes available) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | AHS-6890 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Vial Heating Range | Ambient to 200 °C |
| Valve Temperature Control Range | Ambient to 200 °C |
| Sample Loop Volume | 1 mL |
| Vial Capacity | 9 positions |
| Vial Size | 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | AHS-6890 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Vial Heating Range | Ambient to 160 °C |
| Valve Temperature Control Range | Ambient to 160 °C |
| Temperature Control Accuracy | < ±0.5 °C |
| Sample Loop Volume | 1 mL |
| Vial Capacity | 9 positions |
| Vial Size | 10 mL standard (20 mL default per ASTM/ISO practice |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | AHS1-20A Plus |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve & Transfer Line Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Vial Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL or 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | AHS9-20A PLUS |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Sample Capacity | 20-position carousel |
| Compatible Vial Sizes | 10 mL or 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Heating Range | 40–220 °C |
| Valve Heating Range | 40–220 °C |
| Quantitative Loop Volume | 1 mL |
| Vial Capacity | 20 positions |
| Vial Size | 10 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | AHsS-20A Plus |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Sample Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL or 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | AHzS-20A Plus |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Sample Capacity | 20 positions |
| Vial Compatibility | 10 mL or 20 mL headspace vials |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | AjHS-20A Plus |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Sample Capacity | 20 positions |
| Vial Compatibility | 10 mL or 20 mL headspace vials |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | AmHS-20A Plus |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Quantitative Loop Volume | 1 mL |
| Vial Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Vial Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve & Transfer Line Temperature Range | 40–220 °C (±1 °C accuracy) |
| Quantitative Loop Volume | 1 mL |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Pressurization Time | 0–999 s |
| Purge/Flush Time | 0–30 min |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Interface | USB |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Vial Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL or 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Vial Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | AvHS-20A PLUS |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Vial Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL or 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Vial Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve & Transfer Line Temperature Range | 40–220 °C (±1 °C accuracy) |
| Quantitative Loop Volume | 1 mL |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Wash Time | 0–30 min |
| RSD | <1.0% (at 100 ppm ethanol in water) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Automation Level | Fully Automated |
| Sample Vial Capacity | 20 positions |
| Vial Size | 20 mL (customizable: 10 mL, 50 mL, 100 mL) |
| Sample Heating Range | 40–220 °C (optional up to 300 °C) |
| Valve & Transfer Line Heating Range | 40–220 °C (optional up to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Quantitative Loop Volume | 1 mL (optional: 0.5, 2, 5 mL) |
| RSD | < 1.0% (for 100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Interface | USB |
| Inert Flow Path | Deactivated fused-silica and PEEK tubing throughout |
| Valve Configuration | High-precision 6-port rotary valve with integrated heated zone |
| Sampling Mode | Single-shot, multi-shot per vial, or sequential multi-vial |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve & Loop Heating Range | Ambient to 200 °C (1 °C increments) |
| Sample Transfer Line Heating Range | Ambient to 200 °C (1 °C increments) |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Uniformity (Gradient) | < ±0.5 °C |
| Loop Volume | 1 mL (optional: 0.5 mL or 3 mL) |
| Vial Capacity | 20 mL (optional: 10 mL) |
| Vial Positions | 9 |
| RSD for Injection Precision | ≤1.5% (n = 5, 40 ppm ethanol in water) |
| Purge/Flush Flow Rate | 0–50 mL/min (continuously adjustable) |
| Synchronization | GC trigger, chromatography data system (CDS) event, or external TTL pulse |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | DK-6900A |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Vial Heating Range | Ambient to 200 °C |
| Valve & Loop Heating Range | Ambient to 200 °C |
| Sample Loop Volume | 1 mL (0.5 mL or 3 mL optional) |
| Temperature Control Accuracy | ±0.1 °C |
| Vial Positions | 9 or 12 |
| Vial Capacity | 20 mL (10 mL optional) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve & Transfer Line Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Vial Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL and 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Tray Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL vials |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve Oven Temperature Range | 40–220 °C (±1 °C stability) |
| Loop Volume | 1 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | HS-10A |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Vial Heating Range | Ambient to 200 °C |
| Valve & Quantitative Loop Temperature Control Range | Ambient to 200 °C |
| Quantitative Loop Volume | 1 mL (optional: 0.5 mL or 3 mL) |
| Sample Vial Capacity | 12 positions |
| Vial Size Compatibility | 10 mL and 20 mL |
| Temperature Control Accuracy | < ±0.5 °C |
| Temperature Uniformity (Gradient) | < ±0.5 °C |
| RSD for Injection Precision | ≤1.5% (n = 6, 40 ppm ethanol in water) |
| Purge/Backflush Flow Rate | 0–500 mL/min (continuously adjustable) |
| Dimensions (L × W × H) | 200 × 360 × 420 mm |
| Weight | ~18 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HSA-20A |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Vial Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL vials |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve & Loop Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Quantitative Loop Volume | 1 mL |
| Carrier Gas Control | EPC-compatible (optional) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Pressure Regulation | 0–0.25 MPa (continuously adjustable) |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Pressurization Time | 0–999 s |
| Bake-out/Flush Flow | 0–100 mL/min (adjustable) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SHA-20A |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Loop Volume | 1 mL |
| Sample Position Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | AHnS-20A PLUS |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Oven Temperature Range | Ambient to 200 °C (1 °C increment) |
| Valve & Transfer Line Temperature Range | 40–220 °C (±1 °C stability) |
| Sample Loop Volume | 1 mL |
| Sample Tray Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL vials |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve Heating Range | Ambient to 200 °C (1 °C increment) |
| Loop Volume | 1 mL |
| Temperature Control Accuracy | ±0.5 °C |
| Vial Capacity | 10 positions |
| Vial Size | 20 mL |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HS-3 |
| Pricing | Available Upon Request |
| Sample Heating Range | 40–200 °C |
| Valve Heating Range | 40–200 °C |
| Transfer Line Heating Range | 40–200 °C |
| Sampling Time | 0–20 min |
| Pressurization Time | 0–30 s |
| Purge Time | 0–60 min |
| Injection Time | 0–20 min |
| Loop Volume | 1 mL |
| Vial Capacity | 10 mL or 20 mL |
| Sample Positions | 12 |
| Heating Zone | Single-zone (1 position) |
| RSD | ≤1.5% (for 200 ppm ethanol in water) |
| Power Consumption | 300 W |
| Dimensions (W×D×H) | 500×180×400 mm |
| Net Weight | ~25 kg |
| Brand | Clarete |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | AHSS-12 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Vial Heating Range | Ambient to 260 °C (1 °C increments) |
| Valve & Transfer Line Temperature Control Range | Ambient to 260 °C (1 °C increments) |
| Sample Loop Volume | Standard 2.5 mL (customizable to 5.0 mL) |
| Vial Capacity | 110 positions |
| Compatible Vial Sizes | 10 mL and 20 mL |
| Temperature Control Accuracy | <±0.1 °C |
| Repeatability | RSD ≤1.5% (ethanol in water) |
| Pressure Control Range | 0–0.4 MPa (continuously adjustable) |
| Heating Zones | Three independent zones (vial oven, valve, transfer line) |
| Microprocessor | 32-bit ARM-based high-precision temperature controller with 0.1 °C resolution |