| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | PLD-MPCS2.0A |
| Price | USD 42,000 (approx.) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-VZ6.0 |
| Price Range | USD 7,000 – 14,000 |
| Power Supply | 220 V ±10%, 50 Hz |
| Total Power Consumption | 2.0 kW |
| Temperature Control Range | 20 °C to 100 °C |
| Temperature Stability | ±0.01 °C |
| Sample Capacity | 2 × 12 positions |
| Timing Resolution | 0.01 s |
| Display | 10.4″ LCD touchscreen |
| Control System | Microcontroller-based digital PID control |
| Relative Humidity Limit | <85% RH |
| Compliance Standards | ASTM D445, ISO 3104, GB/T 265 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PMT-2 |
| Price | USD 72,800 (approx. based on ¥520,000 @ 1 USD = ¥7.15) |
| Sensor Generation | 8th-generation dual-laser narrow-beam optical sensor |
| Detection Range | 0.1–0.5 µm (standard) |
| Sampling Method | Precision metering piston pump |
| Flow Control | Dual-stage — high-accuracy piston pump + ultra-precise electromagnetic flow regulator |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Error | ≤2.5% at 1000 particles/mL |
| Calibration Standards | ISO 21501-4, JJG 1061, NIST-traceable latex spheres |
| Compliance | Chinese Pharmacopoeia 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368 |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle threshold alert |
| Data Acquisition | iPad-integrated real-time acquisition |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen version) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Reporting | Particles per mL + ISO 4406 / NAS 1638 contamination codes |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Price | USD 67,500 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2020 Vol. IV, GB 8368-2018 |
| Measurement Range | 0.1–1.0 µm (standard), customizable 1–100 µm or 4–70 µm(c) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle concentration threshold alert |
| Data Acquisition | iPad-compatible wireless telemetry & local touchscreen (color LCD) |
| Software | PULUODY V8.3 Particle Analysis Suite (PC & embedded integrated edition) |
| Compliance | Supports 21 CFR Part 11 audit trail, GLP/GMP-compliant reporting modules |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2-U |
| Price | USD 72,800 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Detector |
| Calibration Standards | ISO 21501-4, JJG 1061, NIST-Traceable Latex Spheres |
| Measuring Range | 0.05–0.2 µm, 0.1–0.5 µm |
| Customizable Channels | 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typ.) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Data Output | 4–20 mA Analog Interface, Real-Time Alarm Trigger |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 Contamination Code |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP environments |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC + iPad-compatible) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2BD |
| Price | USD 75,000 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501-4, JJG 1061, NIST-Traceable Latex Spheres |
| Measurement Range | 0.1–0.5 µm, 0.1–1.0 µm |
| Customizable Channels | 1–100 µm or 4–70 µm (c), down to 0.1 µm (c) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output Interface | 4–20 mA analog output with programmable alarm threshold |
| Data Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Display & Control | 7-inch color TFT touchscreen + optional wireless keyboard/mouse |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC & embedded versions) |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Model | PMT-2RX |
| Sensor Technology | 8th-generation dual-laser narrow-beam particle detection |
| Detection Range | 0.1–0.5 µm and 0.5–5.0 µm (customizable from 0.1 µm to 100 µm) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Calibration Standards | JJG 1061, ISO 21501, or NIST-traceable latex spheres |
| Output Interface | 4–20 mA analog output with configurable contamination alarm |
| Data Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP-aligned environments |
| Software | V8.3 Integrated Analysis & Calibration Suite (PC + touchscreen UI) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | PMT- |
| Pricing | Available Upon Request |
| Detection Principle | Light Obscuration (7th-Generation Dual-Laser Narrow-Beam Sensor) |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Measurement Range | 2–100 µm (or 4–70 µm[c]) |
| Customizable Channels | Up to 1000 size bins, user-selectable 16 channels |
| Accuracy | <3% typical |
| Flow Rate | Sampling: 10–60 mL/min |
| Cleaning | 20–150 mL/min |
| Operating Pressure | 0–0.6 MPa (standard), up to 50 MPa (with pressure regulator) |
| Viscosity Range | Offline: 0–99 mm²/s |
| Online | 0–500 mm²/s |
| Temperature Range | Fluid: 0–80 °C |
| Ambient | −15–50 °C |
| Data Storage | ≥20,000 test records (expandable via USB drive) |
| Compliance | ISO 4406, NAS 1638, SAE AS4059D, GB/T 14039, DL/T 432, GJB 420B, MIL-STD-1246C, ISO 11500 |
| Output Interface | RS232 / RS485-to-USB / Native USB |
| Display | Color LCD touchscreen |
| Power Input | 100–265 VAC, 50–60 Hz |
| Optional Modules | Water Activity (0–1.0 aw, ±0.02 accuracy, NIST-traceable), Trace Moisture (0.1–100,000 ppm), Temperature (−45–125 °C, ±0.00003 °C stability) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PQ-2A |
| Price | USD 13,800 (FOB) |
| Measurement Principle | Electromagnetic Induction-Based Ferrous Particle Quantification |
| Sensitivity | 0.1 mg/g (100 ppm) |
| Max. Concentration Range | 30,000 mg/g |
| Detectable Ferrous Particle Size | >5 µm |
| Sample Volume | 2–5 mL per test |
| Operating Temperature | 0–55 °C |
| Power Supply | 220 V ±15%, 50 Hz or Integrated Rechargeable Li-ion Battery |
| Brand | PULUODY |
|---|---|
| Origin | United Kingdom |
| Manufacturer | PULUODY Analysis & Testing Group Ltd. |
| Type | Imported Industrial Instrument |
| Model | PQ-2A |
| Sensitivity | 0.1 mg/g |
| Max. Iron Concentration Range | 30,000 mg/g |
| Detectable Particle Size | >5 µm |
| Sample Volume | 2–5 mL per test |
| Operating Temperature | 0–55 °C |
| Power Supply | 220 V ±15%, 50 Hz or portable DC power |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | PQ-2A |
| Price | USD 64,500 (FOB China) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PSD-250 |
| Sample Volume Options | 100–1000 mL (customizable, including food-grade, pharmaceutical-grade, sterile, and corrosion-resistant variants) |
| Tubing Diameter | 4–8 mm (customizable) |
| Maximum Vacuum Pressure | 2 kPa |
| Tubing Compliance | NAS 1638 Class 0 |
| Cleaning Bottle Cleanliness | NAS 1638 Classes 0–4 (customizable) |
| Material Options | LC super-hard aluminum alloy (zinc-plated for corrosion resistance) or engineering-grade polymer (molded, hermetic seal) |
| Standards Compliance | GB/T 17489–1998, QC/T 29105.3–1992, DL/T 571–2007 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PSD-250 |
| Pricing | Upon Request |
| Material | LC Super-Hard Aluminum Alloy |
| Capacity Options | 100–1000 mL (customizable for food-grade, pharmaceutical-grade, sterile, and corrosion-resistant applications) |
| Tubing Diameter | 4 mm / 6 mm / 8 mm (customizable) |
| Max Vacuum Pressure | 2 kPa |
| Tubing Compliance | NAS 1638 Class 0 |
| Cleaning Bottle Grade | NAS 1638 Classes 0–4 (customizable) |
| Standards | GB/T 17489–1998, Q/CT 29105.3–1992, DL/T 571–2007 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PSD-351B |
| Gas Source | Nitrogen (optional) |
| Filtration Membrane Diameter | φ43 mm |
| Sample Volume Capacity | 3500 mL |
| Dimensions (W×D×H) | ≤500×500×800 mm |
| Compliance Standards | SY/T 5329–2012, GB 11901–1989, GB/T 606, GB/T 11133, GB 7600 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PSD-650 |
| Price | USD 2,500 (FOB) |
| Compliance | GB/T 7597, IEC 60475, ASTM D923 |
| Temperature Sensor | PT100 (±0.5 °C accuracy) |
| Power | Replaceable Battery |
| Design | Physically Isolated Sampling Tube & Display Module |
| Sampling Method | Continuous Flushing Capability |
| Form Factor | Integrated Compact Assembly with Multi-Valve Control |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PSD-650 |
| Price | USD 2,500 (FOB) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | PSD-650 |
| Price | USD 2,500 (approx.) |
| Sampling Volume Range | 100–1000 mL |
| Temperature Measurement Range | −20 °C to 200 °C |
| Temperature Sensor Accuracy | ±0.5 °C (PT100 embedded probe) |
| Compliance | IEC 60475, ASTM D923, GB/T 7597 |
| Core Components | Two gas-tight glass syringes (standard 100 mL), two 600 mL aluminum sample cylinders, dual-port valves, 1 m PVC sampling hose, insulated carrying case with foam inserts |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PSD-PF100-1A-0.5 |
| Dimensions | 360 × 450 × 580 mm |
| Cleanroom Class | ISO Class 4 (10-class) & ISO Class 5 (100-class) |
| Air Velocity | 0.25 m/s |
| Vibration Amplitude | ≤3 µm |
| Noise Level | ≤67 dB(A) |
| Lighting | Fluorescent Lamp |
| Sterilization | UV-C Lamp (254 nm) |
| Operating Temperature | 10–30 °C |
| Relative Humidity | ≤75% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Construction | Powder-coated steel frame with 304 stainless steel work surface |
| Optional Accessories | High-purity nitrogen inlet with inline filter, articulated nitrogen delivery hose, motorized bidirectional sample rotation stage |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PSD-PF10A-0.5 |
| Cleanliness Class | ISO Class 4 (10 particles ≥0.1 µm per cubic foot) |
| Airflow Velocity | 0.25–0.6 m/s (adjustable) |
| Vibration Amplitude | ≤3 µm |
| Operating Noise | ≤67 dB(A) |
| UV Sterilization Time | 15 min for microbiological decontamination |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Ambient Temp. | 10–30 °C, RH ≤75%, low-vibration, low-dust environment |
| Construction | Fully welded steel frame with epoxy powder coating, 304 stainless steel work surface |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PST-890 |
| Price | USD 53,200 (approx. ¥380,000) |
| Sensor Generation | 8th-Gen Dual-Laser Narrow-Beam Detector |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Calibration Standards | ISO 21501-4, JJG 1061, NIST-Traceable Latex Spheres |
| Software | V8.9 Integrated Particle Analysis Suite (PC & Embedded Touch UI) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Temperature Range (Fluid) | 0–80 °C |
| Environmental Operating Range | −15–50 °C |
| Counting Channels | 1000 configurable channels (user-definable from 4 to 128 size bins) |
| Detection Range | 1–450 µm (extended range 0.03–3000 µm optional) |
| Custom Ranges | 1–100 µm, 4–70 µm(c), 0.1 µm(c) |
| Sampling Accuracy | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Resolution | >95% (per ChP 2015/2020), <10% (per USP <788>, ISO 21501-4) |
| Compliance | GB/T 11446.9–2013, ChP 0903, USP <788>/<789>/<797>, EP 10.0/9.0/8.0, BP 2019/2018, JP 17/16/15, IP 2015, WHO IntPh IV, YBB 00272004–2015, GB 8368, ISO 21510, ISO 11171, NAS 1638, ISO 4406, SAE AS4059, MIL-STD-1246C, JIS B 9933, IP 564/565, ROC T 17216, GB/T 14039, DL/T 432, DL/T 1096, JB/T 9737, GJB/T 420A/B, GB/T 18854 |
| Brand | PULUODY |
|---|---|
| Model | PST-890 |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor |
| Particle Size Range | 1–450 µm (optional extended to 0.03–3000 µm) |
| Resolution | >95% (ChP 2015/2020 calibrated), <10% (USP/ISO 21501 calibrated) |
| Channel Count | 1000 adjustable channels (customizable from 4 to 128 size bins) |
| Flow Control | Precision metering piston pump + ultra-precise electromagnetic flow regulation |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Operating Temperature | Fluid 0–80 °C, Ambient –15–50 °C |
| Compliance | USP <788>, <789>, <797> |
| Brand | PULUODY |
|---|---|
| Model | PST-890 |
| Sensor Technology | 8th-Generation Dual-Laser Narrow-Beam Light Obscuration |
| Detection Range | 1–450 µm (optional 0.03–3000 µm) |
| Channel Count | 1000 adjustable channels (down to 4-channel user-defined bins) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated), <10% (ISO 21501-calibrated) |
| Temperature Range (fluid) | 0–80 °C |
| Compliance | FDA 21 CFR Part 11, ASTM D6786, ISO 21501-4, ISO 11171, USP <788>/<789>, EP 10.0, ChP 0903, GB/T 11446.9-2013, YBB00272004-2015, GB 8368 |
| Software | V8.9 Regulatory-Compliant Particle Analysis Suite with Audit Trail, e-Signature, and 5-Tier User Permissions |
| Calibration Standards | NIST-traceable latex spheres, JJG 1061, or ISO 21501-4 reference materials |
| Sample Compatibility | Aqueous & non-aqueous parenterals, lipid emulsions, lyophilized powders (reconstituted), ophthalmic solutions, vaccines, WFI, medical packaging extracts, infusion sets, filter challenge fluids |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PST-890SIS |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor |
| Particle Size Range | 1–450 µm (optional extension to 0.03–3000 µm) |
| Channel Resolution | 1000 adjustable channels (down to 0.01 µm bin width) |
| Sampling Accuracy | < ±1% |
| Measurement Accuracy | < ±3% (typical) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Resolution Compliance | >95% per ChP 2015/2020 |
| Flow Rate (Sampling) | 5–150 mL/min |
| Flow Rate (Rinse) | 5–500 mL/min |
| Fluid Temperature Range | 0–80 °C |
| Ambient Operating Temperature | −15–50 °C |
| Software | V8.9 Integrated Analysis Suite with 21 CFR Part 11 Compliance |
| Regulatory Alignment | ChP 0903, USP <788>/<789>/<797>, EP 10.0/9.0, BP 2019, JP 17, ISO 21510, ISO 11171, NAS 1638, ASTM D6786, GB/T 11446.9–2013, YBB00272004–2015, GB 8368 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PST-890SIS |
| Sensor | 8th-Generation Dual-Laser Narrow-Beam Particle Sensor |
| Detection Range | 1–450 µm (optional 0.03–3000 µm) |
| Resolution | >95% (per ChP 2015/2020), <10% (per USP/ISO 21501) |
| Channel Count | 1000 adjustable channels (configurable from 4 to 128 size bins) |
| Sampling Flow Rate | 5–150 mL/min |
| Cleaning Flow Rate | 5–500 mL/min |
| Temperature Range (Fluid) | 0–80 °C |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Compliance | USP <788>, <789>, <797> |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PST-890SIS |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor |
| Particle Size Range | 1–450 µm (optional 0.03–3000 µm) |
| Channel Count | 1000 adjustable channels (down to 4-channel custom binning) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated), <10% (USP/ISO 21501-calibrated) |
| Temperature Range (Fluid) | 0–80 °C |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready, Audit Trail, Electronic Signature, 5-Tier User Permission Architecture |
| Software | V8.9 Particle Analysis Suite (PC + embedded touchscreen) |
| Calibration Standards | ISO 21501-4, JJG 1061, NIST-traceable latex spheres |
| Regulatory Alignment | ChP 0903 (2015/2020), USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21510, ISO 11171, NAS 1638, ISO 4406 |
| Brand | PULUODY |
|---|---|
| Model | TQ-01A |
| Application | Pharmaceutical Dissolution Media Deaeration |
| Display | High-Resolution Touchscreen LCD |
| Heating Range | 35–42 °C (adjustable to non-heating mode) |
| Volume Accuracy | ±1% (for set volumes ≥2 L) |
| Dispensing Resolution | 0.1 L |
| Flow Rate | 1.6 L/min |
| Dimensions (L×H×W) | 500 mm × 340 mm × 295 mm |
| Rated Power | 1700 W |
| Temperature Control Accuracy | ±2 °C |
| Residual Dissolved Oxygen | 3.0–5.0 mg/L (upgradable to <2.8 mg/L) |
| Minimum Inlet Medium Temperature | ≥18 °C |
| Pre-Filter Options | 40 µm / 25 µm / 20 µm Stainless Steel Mesh |
| Compatible Media | Purified water, distilled water (pH 1–14, surfactant-free) |
| Brand | Olfasense |
|---|---|
| Origin | Germany |
| Model | PureSniff XL |
| Type | Dynamic Dilution Olfactometer for Direct Undiluted Sample Presentation |
| Regulatory Designation | CE-marked, Compliant with EN 13725:2022 and ASTM D6919-23 |
| Brand | Purity |
|---|---|
| Origin | Beijing, China |
| Model | PF-R, PF-NR |
| Compliance | GB 17378.7–2007 |
| Length | 195 mm (PF-R), 215 mm (PF-NR) |
| Impeller Diameter | 75 mm |
| Connection | Dual-point mounting |
| Counter | 7-digit mechanical register |
| Flow Direction Handling | PF-R — bidirectional (reverse rotation enabled) |
| Brand | PUSH |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PS-KR206 |
| Price | USD 2,380 (approx.) |
| Display | 5-inch HD color touchscreen |
| Sample Capacity | 4 parallel test cells |
| Temperature Control Range | Ambient to 110 °C |
| Temperature Accuracy | ±0.02 °C |
| Temperature Sensor | Imported PT100 platinum resistance thermometer |
| Heating Method | PID-controlled resistive heating |
| Stirring Mechanism | Motorized vertical lift with gear-free mechanical transmission |
| Stirring Duration | 0–99 minutes (adjustable) |
| Timing Range | 0–99 hours (independent countdown timer) |
| Data Storage | 500 test records with timestamp, temperature setpoint, and duration |
| Power Supply | AC 220 V ±20%, 50 Hz ±10% |
| Max. Power Consumption | 800 W |
| Operating Environment | 5–40 °C, <85% RH (non-condensing) |
| Brand | PUSH |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PS-PM201 |
| Price Range | USD 3,300 – 4,200 (FOB) |
| Instrument Category | Laboratory Analyzer |
| Test Parameter | Foam Tendency & Foam Stability |
| Compliant Standards | GB/T 12579, ASTM D892 |
| Temperature Control Range | Low Bath 24 °C / High Bath 93.5 °C |
| Temperature Accuracy | ±0.5 °C |
| Display | High-Resolution Color Touchscreen |
| Power Consumption | 3300 W |
| Air Flow Rate | 94 ± 5 mL/min per diffuser |
| Diffuser Diameter | Ø25.4 ± 0.02 mm |
| Maximum Pore Size | ≤80 µm |
| Air Permeability at 2.44 kPa (250 mm H₂O) | 3000–6000 mL/min |
| Electrical Supply | AC 220 V ±5%, 50 Hz ±5% |
| Operating Ambient | 10–35 °C, ≤85% RH |
| Net Weight | 39 kg |