Industry-specific Instruments
Filter
Showing 4111–4140 of 6344 results
| Brand | QKTester |
|---|---|
| Model | COFT_02 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance Standards | GB 10006–1988, ISO 8295, ASTM D1894 |
| Test Modes | Static & Kinetic CoF |
| Load Range | 0–50 N (typical) |
| Speed Range | 10–300 mm/min |
| Force Resolution | ≤0.01 N |
| Sample Stage | Horizontal Dual-Surface Fixture |
| Data Output | Real-time force-time curve, CoF values (μs/μk), pass/fail flagging |
| Interface | 7″ TFT LCD touchscreen with embedded test protocol library |
| Brand | QKTester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HSPT-01 |
| Temperature Range | Ambient to 300 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Sealing Time | 0.1–999.9 s |
| Sealing Pressure | 0.05–0.7 MPa |
| Sealing Jaw Dimensions | 150 mm × 10 mm (customizable) |
| Heating Mode | Single- or Dual-Side Heating |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Compliant Standards | QB/T 2358, ASTM F2029, YBB 00122003 |
| Brand | QKTester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | OGT-01 |
| Price | USD 145 (FOB) |
| Measured Gases | O₂, CO₂ |
| Measurement Principle | Electrochemical (O₂), Non-Dispersive Infrared (NDIR) Absorption (CO₂) |
| Sample Volume | O₂ < 3 mL |
| Resolution | 0.01% (v/v) |
| Accuracy | ±0.2% (v/v) |
| O₂ Range | 0.2–21.0% (v/v) |
| Standard Sampling Volume | ≥5 mL at 101.3 kPa |
| Dimensions | 350 × 330 × 200 mm (L×W×H) |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 5.5 kg |
| Brand | QKTester |
|---|---|
| Model | OGT-01 |
| Origin | Shandong, China |
| Manufacturer | QKTester Instrument Co., Ltd. |
| Gas Measurement | O₂ (standard), CO₂ (optional) |
| Principle | Electrochemical sensor (O₂), NDIR (CO₂, optional) |
| Range | 0–100% O₂ |
| Resolution | 0.01% |
| Accuracy | ±0.2% O₂ |
| Sample Volume | <3 mL |
| Dimensions | 230 × 120 × 82 mm |
| Weight | 1 kg |
| Power | 220 VAC ±10%, 50 Hz / 120 VAC ±10%, 60 Hz |
| Data Storage | 1500 records |
| Display | Backlit LCD, bilingual (English/Chinese) |
| Interface | Built-in thermal printer |
| Compliance | Designed for ISO 8573-1, USP <1207>, ASTM F2476, and GMP-aligned environmental monitoring workflows |
| Brand | QKTester |
|---|---|
| Model | OGT-02 |
| Measurement Principle | Electrochemical (O₂), NDIR Infrared Absorption (CO₂, optional) |
| Gas Types | O₂ (standard), CO₂ (optional) |
| O₂ Range | 0–100% vol, Resolution: 0.01%, Accuracy: ±0.2% |
| CO₂ Range | 2–100% vol, Resolution: 0.01%, Accuracy: ±(0.03% + 5% of reading) |
| Sensor Lifetime | ~2 years (O₂), >15 years (CO₂) |
| Sample Volume | ≥6 mL (O₂), ≥20 mL (CO₂) |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Dimensions | 350 × 310 × 220 mm |
| Weight | 3.2 kg |
| Compliance | Designed for GMP/GLP environments |
| Brand | QKTester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | WVTR-C1 |
| Test Range | 0.1–10,000 g/m²·24h |
| Test Accuracy | 0.01 g/m²·24h |
| Temperature Range | 10°C–55°C (±0.1°C to ±0.5°C) |
| Humidity Range | 10%RH–90%RH (±1%RH to ±2%RH) |
| Air Velocity | 0.5–2.5 m/s |
| Test Area | 33.18 cm² |
| Specimen Diameter | Φ72–Φ74 mm |
| Test Stations | 1–3 |
| Dimensions | 450×500×550 mm to 850×890×520 mm |
| Power Supply | AC 220 V, 50 Hz |
| Standards Compliance | GB/T 1037, GB/T 16928, ISO 2528, ASTM E96, ASTM D1653, TAPPI T464, DIN 53122-1, JIS Z0208, YBB00092003-2015 |
| Brand | QL |
|---|---|
| Origin | Jiangsu, China |
| Model | HW2000B |
| Detection Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Measurement Range | C: 0.0001–99.999 wt% |
| S | 0.0001–99.999 wt% |
| Precision | C RSD ≤0.5% |
| Sensitivity | 0.1 ppm |
| Analysis Time | 25–60 s (typ. 35 s) |
| Compliance | GB/T 20123–2006 & ISO 15350:2000 |
| Sample Weighing | 0–120 g, readability 0.0001 g |
| High-Frequency Furnace | 2.5 kVA, 18–20 MHz |
| Optical Path | Platinum IR source, gold-plated gas cell, aviation-grade modulation motor, narrow-band interference filters (CO₂ @ 4.26 µm |
| Brand | Qilin (QL) |
|---|---|
| Model | QL-S3000D |
| Measurement Principle | Non-dispersive Infrared (NDIR) for C/S |
| Analysis Time | ~2 min per sample |
| Compliance | GB/T 223.3–5:1988, GB/T 223.68–69:1997 |
| Elemental Range (Typical) | C: 0.001–10.00 wt%, S: 0.0005–0.5000 wt%, Mn: 0.10–15.00 wt%, Si: 0.10–5.00 wt%, P: 0.005–0.80 wt%, Cr: 0.01–25.0 wt%, Ni: 0.010–30.0 wt%, Mo: 0.101–6.00 wt%, Ti: 0.01–1.00 wt%, Cu: 0.01–10.00 wt%, Al: 0.01–8.00 wt% |
| Calibration | 99 programmable calibration curves (regression-based), expandable |
| Data Output | PC-controlled interface, customizable export formats (CSV, TXT, XML), thermal desktop printer support |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | qphox |
| Pricing | Available Upon Request |
| Brand | QS-SOLUTION |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QS-2101 |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QS-3201 |
| Pricing | Available Upon Request |
| Brand | Quadro |
|---|---|
| Origin | Canada |
| Model | U5 Comil |
| Motor | 0.55 kW (3/4 HP) |
| Max Speed | 6500 rpm |
| Throughput | 50 g/hr – 150+ kg/hr |
| PSD (D50) | 150–300 µm |
| PSD (D90) | 300–2000+ µm |
| Design | Gapless conical mill architecture |
| Operation Modes | Dry and wet milling, granulation sizing, deagglomeration |
| Compliance | Designed for GMP-compliant pharmaceutical manufacturing environments |
| Brand | QuankeRida / qktester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | OGT-01 |
| Price | USD 145 (converted from ¥999 at 1:6.9) |
| Measurement Range | 0–21% O₂ (typical) |
| Accuracy | ±0.2% O₂ (full scale) |
| Sample Volume | ≥5 mL (at standard atmospheric pressure) |
| Detection Principle | Fluorescence Quenching or Electrochemical Sensing (user-selectable/configurable per unit) |
| Operation Mode | Manual probe insertion with real-time sensor response |
| Data Storage | Internal non-volatile memory (≥1,000 test records) |
| Power Supply | AC 220 V ±10% or rechargeable Li-ion battery (field-deployable) |
| Dimensions | 350 × 330 × 200 mm (L×W×H) |
| Net Weight | 5.5 kg |
| Brand | Quantum Zurich |
|---|---|
| Origin | Switzerland |
| Model | Fast EQE |
| Measurement Mode | AC |
| Spectral Range | 300–1200 nm |
| Spot Size | 2–12 mm (1 mm optional) |
| Measurement Time per QE Curve | ≤8 s |
| Excitation Source | Multichannel LED Array |
| Bias Light Options | Red, Blue, White (software-controlled) |
| Calibration Compatibility | NIST-traceable reference diodes |
| Configuration Flexibility | Vertical & Horizontal Sample Mounting |
| Operational Modes | In-situ, Real-time, Long-term Stability, Offline, Glovebox-Integrated, Production-Line Ready |
| IQE Extension Support | Yes |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | NO2-LOPAP |
| Pricing | Upon Request |
| Brand | QYB / Quantum Yield Berlin |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LuQY Pro |
| Price Range | USD 27,000 – 68,000 (FOB Hamburg) |
| Measurement Mode | DC Excitation |
| Excitation Wavelength | 520 nm |
| Laser Power Range | 7 µW – 70 mW |
| Photon Flux Equivalent Current | 1.8 µA – 18 mA |
| Adjustable Spot Size (Optional) | 0.5 cm² |
| Spectral Range | 550 – 1000 nm |
| Minimum Detectable PLQY | ≥1×10⁻⁵ |
| Integration Time | 1 ms – 35 min |
| Spectral Sampling Interval | 1 nm |
| Signal-to-Noise Ratio | 600:1 |
| Sample Holder | Customizable (Max. 30 mm × 30 mm × 10 mm) |
| Dimensions | 220 mm × 300 mm × 120 mm |
| Weight | 5.2 kg |
| Calibration Traceability | Fraunhofer ISE CalLab PV Cells (photon flux), NIST-traceable broadband lamp (spectral responsivity) |
| Brand | QYB / Quantum Yield Berlin |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LuQY Pro |
| Measurement Mode | DC |
| Photon Excitation Wavelength | 532 nm |
| Max Laser Power | 140 mW |
| Tunable Excitation Intensity | 4 µA – 40 mA (equivalent to 0.001–10 “suns”) |
| Excitation Spot Size Options | 0.1 cm² / 1 cm² |
| Spectral Range | 550–1050 nm |
| Minimum Detectable Quantum Yield | 1×10⁻⁶ |
| Integration Time | 1 ms – 35 min |
| Spectral Sampling Interval | 1 nm |
| SNR | 600:1 |
| Voltage Source Range | ±10 V |
| Current Source/Measurement Range | ±150 mA |
| Voltage Accuracy | ±10 mV |
| Voltage Sensing Accuracy | ±50 µV |
| Current Sensing Accuracy | ±100 nA / ±1 µA / ±10 µA |
| Sample Holder Max Dimensions | 30 mm × 30 mm × 10 mm |
| Max Subcell Count | 6 |
| Dimensions | 220 mm × 390 mm × 120 mm |
| Weight | 6.1 kg |
| Brand | QYB / Quantum Yield Berlin |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LuQY Pro+ |
| Price Range | USD 200,000 – 500,000 |
| Measurement Mode | DC |
| Excitation Wavelength | 532 nm |
| Maximum Laser Power | 140 mW |
| Tunable Photon Flux (Equivalent Current) | 4 µA – 40 mA |
| Excitation Spot Size Options | 0.1 cm² / 1 cm² |
| Spectral Range | 550 – 1050 nm |
| Minimum Detectable EL/PL Quantum Yield | 1×10⁻⁶ |
| Integration Time | 1 ms – 35 min |
| Spectral Sampling Interval | 1 nm |
| Signal-to-Noise Ratio | 600:1 |
| Voltage Source & Measurement Range | ±10 V, ±150 mA |
| Voltage Source Accuracy | 10 mV |
| Voltage Sensing Accuracy | 50 µV |
| Current Sensing Accuracy | 100 nA / 1 µA / 10 µA |
| Sample Holder | Customizable (Max Subcell Dimensions: 30 mm × 30 mm × 10 mm) |
| Max Simultaneous Subcells | 6 |
| Dimensions | 220 mm × 390 mm × 120 mm |
| Weight | 6.1 kg |
| Brand | QYB / Quantum Yield Berlin |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PLQY Pro |
| Measurement Mode | DC |
| Photon Excitation Wavelength | 532 nm |
| Maximum Laser Power | 140 mW |
| Excitation Spot Size Options | 0.1 cm² or 1 cm² |
| Spectral Range | 550–1050 nm |
| Minimum Detectable Quantum Yield | ≥1×10⁻⁶ |
| Integration Time | 1 ms – 35 min |
| Spectral Sampling Interval | 1 nm |
| SNR | 600:1 |
| Voltage Source Range | ±10 V |
| Current Source/Measurement Range | ±150 mA |
| Voltage Accuracy | ±10 mV |
| Voltage Sensing Accuracy | ±50 µV |
| Current Sensing Accuracy (selectable ranges) | ±100 nA, ±1 µA, ±10 µA |
| Sample Holder | Customizable (max. 30 mm × 30 mm × 10 mm) |
| Max. Subcell Capacity | 6 |
| Dimensions | 220 mm × 390 mm × 120 mm |
| Weight | 6.1 kg |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | A.21/O2 |
| Pressure Measurement Range | 690–2070 kPa (0–500 psi) |
| Response Time | ≤5 ms |
| Pressure Sensor Accuracy | ±0.2 ms timing resolution |
| Ignition Wire | NiCr, 25 cm length, Ø0.6 mm, 3.85 Ω/m |
| Burst Disc | Aluminum, 0.2 mm thickness, nominal burst pressure ≈ 320 psi |
| Ignition Power Supply | 10 A / 16 V constant current |
| Data Acquisition | Digital storage oscilloscope with PC interface and printer output |
| Remote Ignition Distance | ≥2 m (separate control box) |
| Compliance | UN Manual of Tests and Criteria, Rev. 7, Test 2(c)(i).2 |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Beckmann-Junk Method |
| Price Range | USD 27,000 – 68,000 |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | DT400 |
| Heating Block Material | Aluminum per DIN 1725 |
| Sample Well Configuration | 3 × Ø16.2 ± 0.1 mm, depth 70 mm (optional 6-well) |
| Temperature Sensor | PT100 probe |
| Max Operating Temperature | 400 °C (optional 500 °C) |
| Heating Rate Range | 5–20 K/min |
| Temperature Control Accuracy | ±0.1 °C |
| Power Consumption | 1600 VA |
| Cooling Block | Integrated for accelerated post-test cooling |
| Sample Tube Dimensions | Ø16 mm × 130 mm (100 pcs included) |
| Controller | PID-based, housed in separate safety-rated control cabinet |
| Display | Digital readout for actual and setpoint temperature |
| Supply Cable Length | ~2 m |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | HST100 |
| Price Range | USD 27,000 – 68,000 |
| Heating Method | Electrically Heated Aluminum Block |
| Sample Capacity | 21 Positions |
| Sample Tube Dimensions | Ø30 ±0.3 mm × 230 ±2 mm (Cylindrical, Round-Bottom, Glass Stopper) |
| Temperature Range | Ambient to 110 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Sensor | PT100 Probe |
| Over-Temperature Safety Cut-off | 120 °C |
| Controller | Dedicated PID Temperature Program Controller |
| Power Supply | 230 V / 50 Hz, 2400 VA |
| Illumination System | Specialized Fluorescent Lamp (Non-Glare, Optimized for NO₂ Vapor Detection) |
| Viewing Assembly | Rigid Adjustable Lamp Mount with UV-Enhanced Visible Spectrum Output |
| Display | Dual Digital Readout (Setpoint & Actual Temperature) |
| Sample Holder Depth | 170 mm |
| Sample Holder Diameter | 31 mm |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | Methyl Violet Method |
| Temperature Range | 60–140 °C |
| Control Accuracy | ±0.1 °C |
| Sample Capacity | 24 positions (20.5 mm diameter × 280 mm depth) |
| Heating Block | Anodized aluminum with PID controller |
| Temperature Sensor | PT100 probe |
| Safety Features | Over-temperature cut-off, ISO-insulated housing |
| Power Supply | 230 V / 50 Hz, 1500 VA |
| Compliance | MIL-STD-286C (Sections 120 & 134.5), ISO 8765:2017 (Nitrocellulose stability testing) |
| Accessories | 24× cylindrical tubes (OD 20 mm, ID 17 mm, L 290 mm), vented cork stoppers, stainless steel hooks, methyl violet indicator paper (200 sheets/pack) |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | Nitro |
| Temperature Range | RT–135 °C |
| Control Accuracy | ±0.1 °C |
| Heating Method | Electronic PID-controlled aluminum block heater |
| Sample Capacity | 18 parallel tubes |
| Tube Dimensions | Ø19.0 ± 0.5 mm × 270 ± 2 mm |
| Well Diameter | Ø19.75 ± 0.2 mm, Depth: 200 ± 0.2 mm |
| Sensor | PT100 platinum resistance thermometer |
| Overtemperature Cut-off | 150 °C |
| Illumination System | Dedicated low-glare fluorescent lamp for NO₂ vapor detection |
| Power Supply | 230 V, 50–60 Hz |
| Power Consumption | 2400 VA |
| Compliance | ISO-insulated heating plate, Bergmann-Junk test method per DIN 55507-1 / STANAG 4147 |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | OXISTAR I / OXISTAR II |
| Maximum Working Pressure | 21 bar |
| Oxygen Pre-Pressure Range | 25 ±1 bar |
| Compressed Air Pre-Pressure | ≥7 ±0.5 bar |
| Burst Pressure Rating | 35 bar |
| Max Operating Temperature | 150 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Temperature Uniformity | ±1 °C at 70 °C, ±2 °C at 150 °C |
| Pressure Sensor Range | 0–25 bar (±0.5% FS) |
| Rupture Disc Activation Pressure | 32 ±7.5% bar |
| Chamber Volume | 4 L per chamber |
| Heating Power per Chamber | 330 VA |
| Dimensions (W×D×H) | 87 × 66 (45) × 42 cm |
| Weight | 58 kg (OXISTAR II), 42 kg (OXISTAR I) |
| Power Supply | 230 V ±10%, 720 VA (OXISTAR II), 360 VA (OXISTAR I) |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | PVC |
| Pricing | Upon Request |
| Heating Block | Electric |
| Sample Capacity | 32 wells (Ø5.2 mm × 60 mm depth) |
| Temperature Sensor | PT100 probe |
| Safety Feature | Overtemperature protection |
| Controller | Independent PID temperature programmer |
| Display | Dual digital readout (setpoint & actual temperature) |
| Temperature Accuracy | ±0.2 °C |
| Adjustable Range | 60–210 °C |
| Sample Tubes | 100 pcs/set (Ø5 mm × 110 mm) |
| Power Supply | 230 V / 50 Hz, 500 W |
| Optional Accessory | Automated colorimetric detection system compliant with EN 60811-3-2 for objective thermal stability endpoint determination |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | Thermogravimetric Stability Analyzer |
| Heating Range | Ambient to 135 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Capacity | 15 positions |
| Sample Tube Dimensions | Ø15 mm × 155 mm |
| Heating Block | Aluminum, Electrically Heated |
| Temperature Sensor | PT100 probe |
| Safety Cutoff | 150 °C thermal limiter |
| Controller | Dedicated PID temperature controller with digital display of setpoint and actual temperature |
| Power Supply | 230 V / 50 Hz, 1800 VA |
| Vacuum Measurement Method | Mercury manometer (capillary + mercury reservoir) per MIL-STD-286C |
| Compliance | Designed for ASTM E2070, ISO 11119-2, and NATO AEP-97 test protocols |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | VP4000 |
| Pricing | Upon Request |
| Standards Compliance | DIN 51581, CEC L-40-A-93, ASTM D5800 |
| Temperature Range | 150–260 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | < ±0.5 °C at Setpoint |
| Air Flow Control | Adjustable via valve or flowmeter |
| Max Differential Pressure | 21 mmWS |
| Pressure Accuracy | ±0.02 mmWS |
| Test Duration | Fixed 60 min |
| Display | LCD showing real-time temperature, pressure, and elapsed time |
| Dimensions (W×D×H) | 278 × 300 × 316 mm |
| Net Weight | 14 kg |
| Gross Weight | 23 kg |
| Included Components | Main unit, vacuum pump with oil filter, evaporation crucible, test ball, differential pressure controller |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AB140 |
| Price Range | USD 27,000 – 68,000 |
| Heating Block Material | Aluminum |
| Sample Capacity | 5 positions |
| Sample Tube Dimensions | Ø17.5 ± 0.1 mm × 70 mm depth (tube body) |
| Temperature Sensor | PT100 probe |
| Temperature Control | PID controller with independent control cabinet |
| Max Setpoint | 140 °C |
| Temperature Accuracy | ±0.1 °C |
| Power Supply | 230 V / 50 Hz, 300 VA |
| Safety Features | Over-temperature cut-off protection |
| Accessories Included | 5 calibrated cylindrical sample tubes (with three annular bands), perforated rubber stoppers, platinum-tipped glass rods, KI-starch test paper support fixture |