Industry-specific Instruments
Filter
Showing 4141–4170 of 6344 results
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Radioisotope Source Capsule Automatic Inspection System |
| Pricing | Available Upon Request |
| Brand | YIXIST |
|---|---|
| Model | ROE-ME04 |
| Type | Educational Practical Training Device for Optical Metrology |
| Origin | Zhejiang, China |
| Compliance | Designed for ISO/CIE-aligned academic metrology education |
| Software Interface | CIE 1931 xy Chromaticity Diagram Integration, Spectral Data Export (CSV, TXT) |
| Measurement Support | Radiant Flux (W), Luminous Flux (lm), Illuminance (lx), Luminous Efficacy (lm/W), Chromaticity Coordinates (x, y), Correlated Color Temperature (CCT, K) |
| Brand | RAE Systems |
|---|---|
| Origin | USA |
| Model | FGM-1200S |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Sensor Type | Smart Digital NDIR |
| Installation | Fixed Wall/Mast Mount |
| Enclosure Material | Stainless Steel |
| Protection Rating | IP65 |
| Explosion Protection | ATEX II 2G EEx d II CT6, UL/CSA Certified |
| Operating Temperature | CH₄: −40 °C to +70 °C |
| CO₂ | −20 °C to +60 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Pressure Range | 90–110 kPa |
| Power Supply | DC 9–36 V, 60 mA (170 mA @ 24 VDC) |
| Output Signals | 4–20 mA (adjustable, 600 Ω load), RS485 Modbus RTU, Two Programmable Dry Contact Relays (30 VDC, 2 A) |
| Response Time (T90) | ≤30 s |
| Accuracy | ±2% FS |
| Sampling Method | Diffusion |
| Display | Backlit LCD with Four-Color Status LEDs |
| Dimensions (H×W×D) | 168 × 150 × 109 mm |
| Weight | 3.5 kg |
| Brand | RAE Systems |
|---|---|
| Origin | USA |
| Model | PGM-1600 |
| Dimensions | 21 × 8.5 × 6.5 cm |
| Weight | 700 g (with Li-ion battery) |
| Sampling Method | Pump-assisted |
| Enclosure Material | Engineering plastic with rubber overmold |
| Ingress Protection | IP65 |
| EMC Compliance | EMC Directive 89/336/EEC |
| Operating Temperature | −20 °C to +50 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Hazardous Area Certification | Ex ia(d) IIC T4 |
| Display | Graphic LCD with auto-backlight |
| Languages | Chinese, English + icons |
| Alarm | 95 dB @ 30 cm audible alarm, dual-color LED flash |
| Alarm Types | High/Low gas concentration, low battery, sensor fault, pump blockage |
| Data Storage | SD card (Excel-compatible format) |
| Sampling Interval | 1–3600 s adjustable |
| Pump Flow Rate | 450–550 cc/min |
| Battery | 3.7 V rechargeable Li-ion |
| Runtime | Up to 16 h (typical field use) |
| Charge Time | 8 h |
| Calibration | Zero and span calibration |
| Sensor Options | LEL or LEL/VOL catalytic bead sensor |
| Sensor Specifications | O₂ (0–30% vol, 0.1% res., T90 ≤15 s) |
| LEL/VOL (dual-range | 0–100% LEL / 0–100% vol, 1% res., T90 ≤15 s) |
| Brand | Rainbow Photonics |
|---|---|
| Origin | Switzerland |
| Model | TeraKit-D / TeraKit-O / TeraKit-DS |
| THz Generation Material | DAST / OH1 / DSTMS |
| Frequency Range | 0.1–11 THz (model-dependent) |
| Phase-Matching Wavelength | 1200–1700 nm |
| Compatible Laser | External femtosecond laser (pulse width < 80 fs) |
| Imaging Scan Range | 100 mm × 100 mm |
| Optional Integrated Pump Laser | Available in TeraIMAGE configuration |
| Brand | Rainbow Photonics |
|---|---|
| Origin | Switzerland |
| Model | TeraKit-D / TeraKit-O / TeraKit-DS |
| THz Generation Crystal | DAST / OH1 / DSTMS |
| Frequency Range (Reflection) | 0.3–20 THz / 0.1–10 THz / 0.1–15 THz |
| Frequency Range (Transmission) | 0.3–11 THz / 0.1–3 THz / 0.1–11 THz |
| Optimal Phase-Matching Wavelength | 1300–1600 nm / 1200–1460 nm / 1300–1700 nm |
| External Pump Requirement | Femtosecond Laser (70–80 fs pulse width) |
| Optional THz Imaging Scan Area | 50 mm × 50 mm or 100 mm × 100 mm |
| Brand | Ravenfield |
|---|---|
| Origin | United Kingdom |
| Model | BS/C |
| Compliance | ASTM D4741, SH/T 0618-95, IP 320, CEC L-36-A-90, SAE J300 |
| Temperature Range | 60 °C to 180 °C |
| Shear Rate Range | 1 × 10⁵ s⁻¹ to 1.5 × 10⁶ s⁻¹ |
| Measurement Principle | Cone-and-plate Couette flow (Ravensberg method) |
| Output | Dynamic viscosity (mPa·s), torque (mN·m), temperature (°C) |
| Interface | RS-232 serial port |
| Automation Level | Fully automated with embedded microcontroller and guided workflow |
| Brand | Ray-Ran |
|---|---|
| Origin | United Kingdom |
| Model | MFR200 |
| Load Cell Resolution | 0.1 g |
| Temperature Range | Ambient to 450 °C (±0.2 °C stability) |
| Standard Orifice | 2.095 mm diameter × 8.00 mm length |
| Piston Travel | 30 mm |
| Cut-Off Timing Accuracy | ±0.1 s |
| Weight Loading Options | Manual or Pneumatic (up to 11 bar, equivalent to ~21.6 kg force) |
| Compliance | ASTM D1238, ISO 1133-1 & ISO 1133-2, GB/T 3682 |
| Brand | Ray-Ran |
|---|---|
| Origin | Netherlands |
| Model | MFR300 |
| Temperature Range | 0–450 °C (500 °C optional) |
| Temperature Accuracy | ±0.10 °C |
| Temperature Resolution | 0.10 °C |
| Piston Displacement Resolution | ±0.02 mm |
| Heating Zones | Dual-zone |
| Power Supply | 110 V/60 Hz or 220 V/50 Hz, 10 A fuse |
| Connectivity | Wi-Fi, USB, Ethernet |
| Compliance | ISO 1133, ASTM D1238, GB/T 3682 |
| Brand | Rayscience |
|---|---|
| Origin | Germany |
| Model | IPCE |
| Price | €40,000 |
| Measurement Mode | DC |
| Spectral Range | 390–1090 nm |
| Measurement Time per Wavelength | 8 s |
| Number of Wavelengths | 40 |
| Spot Size | 4–12 mm |
| Working Distance | 5 mm |
| Light Source | High-Stability LED Array |
| Bias Voltage Range | ±5000 mV |
| Photodiode Monitor | Integrated |
| Background Illumination Options | Red / Blue / White |
| Connector Type | Male BNC |
| Operating System | Windows |
| Input Voltage | 220 V AC |
| Dimensions (L×W×H) | 45 × 28 × 38 cm |
| Weight | 46 kg |
| Warranty | 1 Year Comprehensive (Parts, Labor, Global Return Shipping) |
| Software | GUI-Based FastEQE Suite with Unlimited Installations & Free Updates |
| Brand | Rayscience |
|---|---|
| Origin | Germany |
| Category | Class A Solar Simulator |
| Spectral Match | AM0 & AM1.5 |
| Effective Irradiation Area | ≥300 mm (Class 3) |
| Total Irradiance Range | 0.8–1.2 solar constants (AM0) |
| Spatial Uniformity | ≤±2% |
| Temporal Instability | ≤±1% (over 10 s) |
| Light Source | Ozone-free short-arc xenon lamp (150 W) |
| Lamp Lifetime | ≥1500 h |
| Beam Configuration | Collimated (60 mm × 60 mm) and non-collimated (up to 60 cm²) |
| Compliance | IEC 60904-9 Ed. 3 (2020), ASTM E927-22, JIS C 8912 |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | RB-I |
| Pricing | Available Upon Request |
| Tube Height | 60 mm |
| Tube Inner Diameter | 52 mm |
| Timer Range | 10–120 min |
| Temperature Control Accuracy | 37.0 ± 0.5 °C |
| Mesh Disk Dimensions | 50 mm diameter, 39 apertures of 4 mm each |
| Flip Frequency | 1 cycle per 10 min |
| Test Stations | 3 independent tube–mesh assemblies |
| Beaker Capacity | 4 L |
| Power Rating | 1000 W |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | RC-6 |
| Price | USD 2,400 (FOB Tianjin) |
| Speed Range | 20–200 rpm |
| Speed Accuracy | ±2 rpm |
| Temperature Control Range | Ambient to 39.9°C |
| Temperature Accuracy | ±0.3°C |
| Timer Range | 0–999 minutes per station (6 stations) |
| Basket Wobble | ≤1 mm |
| Paddle Shaft Wobble | ≤0.05 mm |
| Power Supply | 220 V AC, 50 Hz, 1000 W |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | RC-8D |
| Pricing | Available Upon Request |
| Speed Range | 20–200 rpm |
| Speed Accuracy | ±2 rpm |
| Temperature Control Range | Ambient to 39.9 °C |
| Temperature Accuracy | ±0.3 °C |
| Timing Range | 0–999 min (6 programmable time points) |
| Basket Wobble Tolerance | ±1 mm |
| Paddle Shaft Runout | ±0.5 mm |
| Power Supply | 220 V / 50 Hz / 1000 W |
| Dimensions (W×D×H) | 960 × 520 × 480 mm |
| Construction Materials | SUS316L stainless steel (baskets, paddles, shafts), magnetically driven recirculating water bath system |
| Automation Features | Motorized head lift, dual-zone cup configuration (6 test cups + 2 auxiliary reservoir cups), real-time parameter display, stored USP/ChP dissolution methods, auto-diagnostic alerts, programmable multi-stage timing with audible notification |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | RC-8DS |
| Pricing | Available Upon Request |
| Stirring Speed Range | 20–200 rpm |
| Speed Accuracy | ±2 rpm |
| Temperature Control Range | Ambient to 39.9 °C |
| Temperature Accuracy | ±0.3 °C |
| Timer Range | 0–999 min (6 programmable time points) |
| Basket Wobble Tolerance | ±1 mm |
| Paddle Wobble Tolerance | ±0.5 mm |
| Power Supply | 220 V / 50 Hz / 1000 W |
| Dimensions (W×D×H) | 680 × 540 × 480 mm |
| Construction Material | Imported SUS316L stainless steel for baskets, paddles, and shafts |
| Fluid Circulation System | Magnetic-drive water pump with uniform thermal distribution |
| Control Mode | Intelligent microprocessor-based PID control for temperature, rotation speed, and timing |
| Automation Features | Motorized head lift/lower mechanism, auto-diagnostic self-check, real-time parameter display (set vs. actual), programmable multi-point timed sampling alerts, USP-compliant dissolution method storage |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HTDS-002 |
| Price | USD 620,000 (FOB Yokohama) |
| Origin | Switzerland |
|---|---|
| Standard Compliance | ASTM D3828, IP 303, ISO 3679 |
| Model | OilLab 620 |
| Temperature Range | −50 °C to +350 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Sensor Type | PT100 Class A |
| Sample Volume | ~4 mL |
| Heating System | Electronic with Over-Temperature Protection |
| Cooling Method | Forced-air fan cooling |
| Dimensions (W×D×H) | 31 × 47 × 52 cm |
| Weight | 27 kg |
| Power Supply | 220 V ±15 %, 50/60 Hz |
| Ambient Limits | ≤35 °C, ≤80 % RH |
| Safety Certification | CE |
| Brand | Red Sun Instrument |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HR-W2400 |
| Pressure Range | 200–5000 Pa (adjustable) |
| Test Duration | 1–10 min (adjustable) |
| Pressure Resolution | 1 Pa |
| Acoustic Noise Level | ≤50 dB(A) |
| Operating Mode | Continuous |
| Bubble Point Accuracy | ±10 mbar |
| Diffusion Flow Resolution | 0.1 mL/min |
| Water Intrusion Flow Resolution | 0.01 mL/min |
| System Sensitivity | ±1.0 mbar |
| Max Test Pressure | 9999 mbar |
| Min Supply Pressure | 100 mbar |
| Gas Supply Requirement | Clean, dry air or nitrogen (4000–6999 mbar) |
| Power Supply | 100–240 V AC, 50/60 Hz, 100 W |
| IP Rating | IP54 |
| Data Storage Capacity | 10,000 test records |
| Display | 10-inch full-color TFT touchscreen |
| Communication Interfaces | RS232, USB, optional industrial bus (e.g., Modbus RTU), wireless module |
| Printer Options | Built-in thermal or dot-matrix printer |
| User Management | Up to 9-level permission hierarchy with electronic signature support |
| Audit Trail | Time-stamped, immutable event log (user login/logout, parameter changes, test execution, result modification, calibration, system errors) |
| Compliance | Fully aligned with FDA 21 CFR Part 11, EU Annex 11, and ISO 13485 |
| Brand | Red Sun Instrument |
|---|---|
| Origin | Hebei, China |
| Model | HR-WZX2600 |
| Price | USD 8,200 (FOB) |
| Application | Pharmaceutical Sterile Filtration Validation |
| Compliance Basis | ASTM F838-22, ISO 13408-2, USP <1207>, EU Annex 1 (2022), FDA Guidance for Industry – Sterile Drug Products (2004) |
| Brand | Red Sun Instrument |
|---|---|
| Origin | Hebei, China |
| Model | HRWK-300 |
| Temperature Range | Ambient to 300 °C |
| Heating Rates | 50 °C/h and 120 °C/h |
| Deformation Measurement Range | −1.000 mm to +10.000 mm |
| Vicat Needle Tip Area | 1.00 ± 0.015 mm² |
| Sample Holder Thermal Expansion Coefficient | < 0.005 mm/100 °C |
| Compliance | GB/T 1633, GB/T 8802, GB/T 1634, ISO 306, ISO 75, ISO 2507, ASTM D 1525, ASTM D 648 |
| Brand | Red Sun Instrument |
|---|---|
| Origin | Hebei, China |
| Model | HRWZ-2600 |
| Power Supply | 100–240 V AC, 50/60 Hz, 120 W |
| Maximum Operating Pressure | 10,000 mbar (150 psi) |
| Inlet Gas Pressure Range | 100 mbar (1.5 psi) |
| Bubble Point Test Range | 100–8,000 mbar |
| Diffusion Flow Measurement Range | 1–600 mL/min |
| Water Intrusion Range | 0.01–100 mL/min |
| Test Accuracy | Bubble Point ±50 mbar |
| Dimensions (L×W×H₁×H₂) | 400 × 240 × 270 × 220 mm |
| Weight | 8 kg |
| Ambient Operating Conditions | 5–40 °C, 10–80% RH |
| Display | 7-inch high-resolution color touchscreen |
| Connectivity | RS232, USB, 4–20 mA analog output, RS485, 12 V alarm output |
| Data Storage | ≥10,000 test records |
| Pre-stored Methods | 120 |
| User Access Control | Four-tier permission system with username/password login |
| Audit Trail | Full event logging compliant with FDA 21 CFR Part 11 requirements |
| Test Modes | Manual bubble point, standard bubble point, enhanced bubble point, pressure hold, diffusion flow, water intrusion, ultrafiltration module testing |
| Brand | Red Sun Instrument |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HRYQ-2600 |
| Price | ¥72,000 CNY |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Dimensions (L×W×H) | 500 × 200 × 180 mm |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 10–80 % RH |
| Test Methods Supported | Pressure Hold (Diffusion Flow), Bubble Point (Standard & Enhanced), Water Intrusion, Manual Bubble Point |
| Origin | Canada |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WinScanopy |
| Pricing | Available Upon Request |
| Brand | Regmed |
|---|---|
| Origin | Brazil |
| Model | MD-3000 |
| Motor Power | 5.5 kW |
| Operating Speed | 1750 rpm |
| Consistency Range | 2–8% |
| Refining Chamber Volume | 50 L |
| Disc Gap Adjustment | 0–9 mm |
| Disc Diameter | 300 mm |
| Material of Wetted Parts | Bronze and Stainless Steel |
| Cooling Requirement | 3 bar, 0.5 m³/h clean water |
| Electrical Supply | 380 V, 60 Hz, 3-phase |
| Dimensions (W×D×H) | 850 × 750 × 1800 mm |
| Weight | 250 kg |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MTA-2000C |
| Pricing | Available Upon Request |
| Brand | Regmed |
|---|---|
| Origin | Brazil |
| Model | REGMED-VB-21 |
| Refining Capacity | 360 g (oven-dry basis) |
| Beater Bowl Volume | 23 L |
| Roll-to-Plate Contact Force | 105 N ± 1 N |
| Roll Speed | 500 ± 10 rpm |
| Shear Velocity | ~5 m/s |
| Working Consistency | 1.57% |
| Power Supply | 220 VAC, 50/60 Hz, 2 kW |
| Dimensions (W×L×H) | 1200 × 850 × 1100 mm |
| Weight | 450 kg |
| Compressed Air Requirement | Clean, dry air, 1.5–6.0 kgf/cm² (set at 5 kgf/cm²) |
| Materials | AISI 410 hardened stainless steel (roll: 350–400 HB |
| plate | 325–375 HB) |
| Standards Compliance | TAPPI T 200, T 205 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 12210 |
| Pricing | Available Upon Request |
| Brand | RELION |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MICRODRILL SYSTEM |
| Pricing | Available Upon Request |
| Brand | RELION |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Ni Host Unit |
| Pricing | Upon Request |
| Brand | RELION |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RELION VI CL |
| Price Range | USD 42,000 – 70,000 |
| Power Supply | 220 V AC, 50–100 Hz |
| Operating Environment | Temperature < 30 °C, Relative Humidity < 60 % |
| Vacuum Chamber | Dual lead-glass windows (top Reentrant Window & bottom transmission window), minimum working distance 5–7 mm for high-NA objectives (e.g., 50×) |
| Ultimate Vacuum | 0.25 Pa |
| Electron Gun | Horizontal cold-cathode type |
| Acceleration Voltage | 0–30 kV (adjustable in 100 V increments |
| Beam Current | 0.15–1 mA typical, up to 5 mA max (overcurrent protection) |
| Beam Focus | Continuous defocusing-to-point focusing control |
| Sample Holders | Triple-slot thin-section tray, granular sample holder, flat plate holder, and tray mount |
| Vacuum System | High-performance turbomolecular pump with foreline valve, anti-fogging trap, dual vibration-dampened vacuum hoses |
| Digital Interface | Real-time display of voltage, current, vacuum pressure, operation mode (auto/manual), HV status, and electron gun output limits |