Industry-specific Instruments
Filter
Showing 4081–4110 of 6344 results
| Brand | PUSH |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Model | PS-SD01 |
| Light Source | 220 V / 100 W frosted incandescent lamp (color temperature 2750 ± 50 K) |
| Color Disc | 26 apertures (Φ14 mm), 25 loaded with calibrated glass color standards (ASTM D1500 / GB/T 6540 / ISO 2049 equivalent No. 1–25), 1 blank aperture |
| Viewing System | Compound optical eyepiece (concave + convex lenses) with focus and brightness adjustment |
| Power Supply | 220 V ± 10 %, 50 Hz ± 1 Hz |
| Compliance | SH/T 0168–92, GB/T 6540–2016, ASTM D1500–22, ISO 2049:2018 |
| Brand | PV Measurements |
|---|---|
| Origin | USA |
| Type | Import |
| Model | CELL |
| Automation Level | Fully Automatic |
| Active Area | 1 cm² |
| Voltage Measurement Accuracy | ±1% |
| Current Measurement Accuracy | ±1% |
| Brand | PV Measurements |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IV5 |
| Automation Level | Fully Automated |
| Light Source | Continuous 5 cm × 5 cm ABA-class (optional AAA-class) solar simulator |
| Voltage Ranges | ±2.0 V, ±10.0 V |
| Current Ranges | 0.1 mA to 1.0 A |
| Measurement Method | Four-wire Kelvin sensing |
| Compliance | IEC 60904-9, JIS C 8912, ASTM E927-19 |
| Standard Reference Cell | NREL-traceable 20 mm × 20 mm monocrystalline Si cell with ISO/IEC 17025 calibration certificate |
| Software | Windows-based PV characterization suite with automated data acquisition, parameter calculation, report generation, and audit-trail-enabled export |
| Brand | PV Measurements |
|---|---|
| Origin | USA |
| Product Type | Imported Reference Solar Cell |
| Model | Outdoor Photovoltaic Reference Cell |
| Certification | Compliant with IEC 60904-2 |
| Effective Area | 1 cm² |
| Open-Circuit Voltage (Voc) Temperature Coefficient (TCR) | < 25 ppm/K |
| Voc Tolerance | ±1% |
| Shunt Resistance | 0.004 Ω (for split 156-cell configuration) or 0.13 Ω (for 20 mm × 40 mm shunt resistor, adjustable) |
| Integrated Sensor | Class A RTD-Pt100 (4-wire) |
| Electrical Interface | Amphenol Eco-Mate connectors (X2) for Voc (2-wire), Isc (2-wire), RTD (4-wire), and optional auxiliary cells (2-wire each) |
| Calibration Traceability | NREL (USA) or NIM (China) |
| Brand | PV Measurements |
|---|---|
| Origin | USA |
| Model | QEX12M |
| Measurement Mode | DC |
| Wavelength Range | 300–1100 nm (extendable to 1400 nm / 1800 nm) |
| Spectral Bandwidth | Adjustable via monochromator slit (default ~10 nm) |
| Wavelength Step | User-selectable (default 10 nm) |
| Repeatability | ±1% (400–1000 nm), ±2% (300–400 nm & 1000–1100 nm) |
| Sample Size Capacity | Up to 1 m × 2 m |
| Bias Light | Broadband, 0–1 SUN, Ø1.5 cm spot, with optional spectral filtering |
| Bias Voltage Range | −5 V to +40 V |
| Photocurrent Protection | 150 mA max |
| Chopper Frequency | 4–200 Hz |
| Calibration Traceability | NIST-traceable reference photodiode |
| Compliance | ASTM E1021-06, IEC 60904-8, ISO 18583 |
| Brand | PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HSR-200 |
| Price | Upon Request |
| Force Sensor Standard | 5 lbf (2.2 kN) |
| Optional Sensors | 2 lbf / 10 lbf |
| Force Accuracy | ±0.1% of full scale |
| Speed Modes | Constant & Ramp |
| Constant Speed Range | 30–1000 fpm (10–300 m/min) |
| Ramp Speed Profiles | 0–1, 0–2, 0–3, 0–4, 0–5 m/s |
| Test Compliance | FINAT FTM 4 |
| Operating Temperature | 0–70 °C |
| Power Input | 85–265 VAC, 50/60 Hz |
| Dimensions (H×W×D) | 35 × 53 × 28 cm |
| Weight | 11 kg |
| Display | 5.7" capacitive touchscreen |
| Data Sampling | Up to 400 points per test (adaptive rate) |
| Output Units | g, kg, oz, lb, N |
| Data Export | USB to EZ Data software |
| Standalone Operation | Yes |
| Brand | YueLian / PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PW-MIT02 |
| Pricing | Available Upon Request |
| Power Supply | AC 220 V ±10%, 50 Hz (AC 110 V ±10%, 60 Hz optional) |
| Operating Temperature | 10–35 °C |
| Relative Humidity | ≤85% RH |
| Display | 5-inch color TFT touchscreen interface |
| Test Area | 7 ± 0.05 cm² |
| Folding Angle Range | 0–180° (user-configurable and real-time displayed) |
| Cycle Count Range | 0–99,999 cycles |
| Folding Speed | 5–65 cycles/min |
| Bend Radius Options | R1 mm, R1.5 mm, R2 mm (three interchangeable mandrels supplied) |
| Dwell Time Adjustment | 0–99 s (programmable) |
| Folding Platform Dimensions | 200 × 150 mm (dual stations: front & rear) |
| Overall Dimensions | 580 × 490 × 360 mm (W × D × H) |
| Net Weight | ~35 kg |
| Data Output | Built-in thermal printer |
| Standard Configuration | Main unit + embedded thermal printer |
| Optional | Continuity monitoring module (open/short detection during folding) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN B02-S |
| Light Source | 1800 W Air-Cooled Xenon Arc Lamp |
| Spectral Filtering | ISO Window-IR / AATCC Window-B/SL Dual-Filter System |
| Irradiance Control | SOLAR EYE® Sensor at 340 nm, 420 nm, or TUV |
| Humidity Control | Programmable Relative Humidity (RH) with Purified Water Requirement |
| Optional Feature | Purified Water Spray (Top-Mounted Nozzle, Light/Dark Cycle Configurable) |
| Sample Orientation | Vertical Mounting |
| Black Panel Temperature Control | Yes |
| Chamber Air Temperature Control | Yes |
| Compliance | ISO 105-B02, ISO 105-B04, AATCC TM16, AATCC TM169 |
| Lamp Life | ~1500 hours |
| Connectivity | Built-in Ethernet for Data Logging |
| Calibration | PATENTED AUTOCAL® System |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-2 |
| Lamp | 1 × 1800 W air-cooled xenon arc lamp |
| Sample capacity | 31 specimens (46 mm × 122 mm) |
| Sample orientation | vertical (90° to horizontal) |
| Irradiance control points | 340 nm, 420 nm, or TUV (300–400 nm) |
| Black panel temperature range | 25–105 °C |
| Relative humidity range | 20–95 % RH |
| Dimensions (W×H×D) | 91 × 166 × 69 cm |
| Weight | 172 kg |
| Power supply | 220 V, 50/60 Hz |
| Optional features | humidity control, water spray system, SOLAR EYE irradiance feedback control |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-2 |
| Light Source | 1800 W Air-Cooled Xenon Lamp |
| Spectral Range | Full-spectrum Solar Simulation (UV, Visible, NIR) |
| Irradiance Control | Solar Eye® Closed-Loop Radiometer System |
| Temperature Control | Black Panel Temperature (35–105 °C), Chamber Air Temperature |
| Humidity Control | Standard Relative Humidity (RH) Regulation (Requires Deionized Water) |
| Optional Feature | Water Spray Function (Operates in Light/Dark Cycles) |
| Sample Capacity | 31 Specimens (46 mm × 122 mm) |
| Compliance | ISO 4892-2, ASTM G155, AATCC TM16, ISO 105-B02/B04/B06, GB/T 8427, JIS L0843, SAE J2527, PV 1303, VDA 675242, and >30 Other International Standards |
| Calibration Traceability | NIST-Traceable, ISO/IEC 17025 Accredited Laboratory |
| Connectivity | Built-in Ethernet, Remote Monitoring & Data Logging Support |
| User Interface | Multilingual Controller (EN/FR/ES/IT/DE), Self-Diagnostic Alerts, Virtual Bar Chart Software Integration |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-2 |
| Light Source | Full-spectrum xenon arc lamp |
| Irradiance Control Points | 340 nm, 420 nm, or TUV (300–400 nm) |
| Humidity Control | Standard relative humidity (RH) regulation |
| Water Spray | Optional top-mounted nozzle, programmable in light/dark cycles |
| Sample Mounting | Rotating drum with vertical specimen orientation |
| Temperature Monitoring | Black panel temperature + chamber air temperature |
| Compliance | ASTM G155, ISO 105-B02, ISO 11341, AATCC TM16, GB/T 8427 |
| Connectivity | Built-in Ethernet interface |
| Calibration | AUTO-CAL automated calibration system |
| Language Support | English, French, Spanish, Italian, German |
| Brand | Qigao Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HSY-0613G |
| Temperature Range | Ambient to 90 °C |
| Compliant Standard | Chinese Pharmacopoeia 2025 (ChP 2025) |
| Test Method | ChP Method 0613 for Freezing Point Determination |
| Control Accuracy | ±0.1 °C |
| Measurement Accuracy | ±0.1 °C |
| Temperature Sensor | Pt100 (1/3 DIN Class B) |
| Heating Element | Stainless Steel Immersion Heater |
| Display | 5.7″ TFT LCD, 65K-color, Full-touch Industrial Panel |
| Printing | 20-character Thermal Dot-Matrix Printer |
| Sample Handling | Dual-sample Mechanical Stirring |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max Power Consumption | ≤1000 W |
| Dimensions (W×H×D) | 320 × 500 × 460 mm |
| Operating Environment | 0–45 °C, RH < 80% |
| Enclosure Material | Powder-Coated Aluminum Chassis |
| Bath Vessel | Double-Walled Vacuum Insulated Transparent Dewar |
| Illumination | Integrated LED Sample Chamber Lighting |
| Self-Diagnostic Routine | Built-in System Health Check |
| Brand | Qigao Instruments (SHQIGAO) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | HSY-14190 |
| Price Range | USD 420 – 4,200 (FOB Shanghai) |
| Compliance | GB/T 14190–2017 |
| Measurement Principle | Ubbelohde capillary viscometry in dilute solution |
| Temperature Control Range | Ambient to 100 °C |
| Accuracy | ±0.1 °C |
| Bath Capacity | 20 L dual-cylinder constant-temperature bath (300 × 300 mm inner cylinder, 4-port configuration) |
| Capillary ID | 0.88 mm |
| Power Supply | AC 220 V ±10%, 50 Hz ±5% |
| Total Power Consumption | ≤1800 W |
| Dimensions (Main Unit) | 430 × 500 × 660 mm (L×W×H) |
| Refrigerator Unit (Optional) | 430 × 430 × 300 mm |
| Net Weight | 50 kg |
| Brand | Qigao Instruments (SHQIGAO) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HSY-4509K |
| Pricing | Upon Request |
| Temperature Control Range | 20.00 °C to 50.00 °C |
| Temperature Control Accuracy | ≤ ±0.1 °C |
| Penetration Measurement Accuracy | ≤ ±0.1 mm |
| Maximum Penetration Depth | 660 penetration units (0.1 mm increments) |
| Brand | Qigao Instruments (SHQIGAO) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HSY-4985 |
| Penetration Range | 0–650 dmm |
| Timing Options | 5 s, 8 s, 10 s, 12 s, 30 s, 60 s (±0.1 s accuracy) |
| Resolution | 0.01 mm |
| Penetration Accuracy | ±1 dmm |
| Standard Needle Mass | 2.5 g ±0.05 g |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤300 W |
| Dimensions | 280 × 350 × 700 mm (L×W×H) |
| Optional Accessories | Cooled/heated bath (5–40 °C), magnifier with cold light source, interchangeable needle/cone attachments |
| Brand | Qigao Instruments (SHQIGAO) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HSY-7323 |
| Power | 1500 W |
| Temperature Control Range | Ambient to 95 °C |
| Temperature Accuracy | ±1 °C |
| Heating Method | Water Bath |
| Control System | Digital PID Temperature Controller |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Environment | 0–45 °C, ≤80% RH |
| Brand | Qigao Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HSY-8146H |
| Temperature Range | Ambient to 162 °C |
| Temperature Resolution | 0.1 °C |
| Brand | Qigao Instruments / SHqigao |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | SYD-2801 |
| Price | Upon Request |
| Penetration Range | 0–700 dmm |
| Minimum Readout | 0.1 dmm |
| Resolution | 0.01 mm |
| Penetration Accuracy | ±1 dmm |
| Temperature Range | 5.0–100.0 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Bath Volume | 5.5 L |
| Circulation Flow Rate | 5 L/min |
| Pump Head | 1 m |
| Power Supply | AC (220 ± 10%) V, 50 Hz |
| Power Consumption | ≤1800 W |
| Dimensions (L×W×H) | 520 × 330 × 600 mm |
| Brand | Qigao Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XRY-1B |
| Thermal Capacity | 10500–14500 J/K |
| Temperature Resolution | 0.0001 K |
| Heat Value Accuracy | ±60 J/g |
| Repeatability Error | ≤0.2% (Class C) |
| Oxygen Bomb Pressure Rating | 20 MPa |
| Temperature Measurement Range | 10–35 °C |
| Ambient Operating Temperature | 20 °C ±5 °C (max. fluctuation ±1 °C during test) |
| Data Storage Capacity | 1000 records |
| Relative Humidity Limit | ≤85% RH |
| Power Supply | AC 220 V ±5%, 50 Hz |
| Power Consumption | ≤150 W |
| Dimensions (L×W×H) | 720 × 580 × 470 mm |
| [Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJBLC-73 |
| Drop Height Range | 300–2000 mm |
| Accuracy Class | ≥ Grade 1 |
| Drop Orientation | Face, Edge, Corner |
| Height Display | LED Digital Indication |
| Height Repeatability Error | ≤ ±2% of Set Value |
| Maximum Load Capacity | 60 kg |
| Test Chamber Dimensions | 1000 × 800 × 800 mm |
| Angular Deviation During Drop | ≤ 5° |
| Motor Power | 0.5 HP |
| Power Supply | AC 380 V, 50 Hz, 10 A |
| Machine Dimensions (L×W×H) | ≈ 1700 × 1200 × 3015 mm |
| Net Weight | 435 kg |
| Compliant Standards | ISO 2248, JIS Z0202-87, GB/T 4857.5–1992] |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QJBV212P |
| Load Capacity | 100 kN |
| Force Measurement Range | 1–99.99% FS |
| Force Accuracy | ≤ ±0.5% FS |
| Force Stability | ≤ ±0.5% (of reading) |
| Alignment (Coaxiality) | ≤ 8% |
| Crosshead Speed | 0.01–60 mm/min |
| Stroke (Lower Rod) | ≥ 80 mm |
| Strain Rate Range | 10⁻⁶ – 1 mm/s |
| Specimen Geometry | Ø10 × 180 mm (30 mm gauge length) |
| Operating Temperature Range | RT + 10 °C to 60 °C |
| Temperature Uniformity | ≤ ±2 °C |
| Corrosive Medium Volume | ≥ 400 mL |
| Communication Interface | Ethernet (TCP/IP) |
| Control Architecture | Dual-ARM Digital Controller with Decoupled Measurement & Processing |
| Compliance | GB/T 15970.7–2000, HB 7235–1995 |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QJLCD-30 |
| Price | USD 8,400 (FOB Shanghai) |
| Drop Height Range | 400–1800 mm (±0.5 mm positioning accuracy) |
| Adjustable Drop Angles | 0°, 45°, 90° (supports face, edge, and corner impacts per IEC 60068-2-32) |
| Vacuum Suction Cups | Six Ø16 mm industrial-grade cups |
| Max Test Specimen Mass | 700 g |
| Drop Surface Dimensions | 350 × 350 × 50 mm |
| Drop Surface Options | Polished marble (Ra = 0.59 µm) or cured cement board (Ra = 1.29 µm), customizable |
| Drive System | Servo motor + timing belt |
| Control System | Industrial touchscreen HMI + PLC |
| Air Supply Requirement | ≥0.6 MPa clean compressed air |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Rated Power | 400 W |
| Overall Dimensions | 800 × 900 × 2400 mm |
| Net Weight | 270 kg |
| Brand | QINGTAO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | QT-KY01 |
| Max Test Load | 2000 kgf |
| Accuracy Class | Class 1 (per GB/T 16491 / ISO 7500-1) |
| Force Measurement Range | 0.4–100% FS |
| Force Accuracy | ±1% of reading |
| Force Resolution | 1/200,000 |
| Displacement Accuracy | ±1% of reading |
| Displacement Resolution | 0.05 mm |
| Test Speed Range | 10–300 mm/min |
| Speed Accuracy | ±1% of set value |
| Test Chamber Dimensions (optional) | 600×600×600 mm, 800×800×800 mm, 1000×1000×1000 mm, 1200×1200×1200 mm, or 1500×1500×1500 mm |
| Control System | Embedded microcomputer with optional industrial touchscreen interface |
| Drive System | Gearmotor + frequency inverter |
| Motor Power | 0.75 kW |
| Compliance Standards | ISO 2872, ISO 2874, TAPPI T 804, JIS Z 0212, NF H3 001, CNS 2236 / 3511, QB/T 1048 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | QJ211S |
| Load Capacity | 20 kN |
| Force Accuracy | Class 0.5 |
| Effective Force Range | 0.02–100% of full scale |
| Force Resolution | 500,000 counts (single-range, no auto-ranging) |
| Effective Test Width | 460 mm |
| Effective Vertical Travel (excluding fixtures) | 1500 mm |
| Test Speed Range | 0.001–1000 mm/min (programmable) |
| Speed Accuracy | ±0.5% of indicated value |
| Displacement Accuracy | ≤0.2% of indicated value |
| Strain/Deformation Accuracy | ≤0.2% of indicated value |
| Noise Level | ≤76 dB(A) |
| Continuous Operational Duty Cycle | ≥2000 h |
| Critical Component Service Life | ≥8000 h |
| Motor Power | 0.75 kW |
| Dimensions (W×D×H) | ≈670×600×2220 mm |
| Net Weight | ≈195 kg |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QJRZ-45 |
| Quotation | Available upon Request |
| Temperature Range | 0–300 °C |
| Temperature Stability | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Barrel Diameter | Φ9.55 mm ±0.025 mm |
| Die Orifice Diameters | Φ2.095 mm ±0.005 mm and Φ1.180 mm ±0.010 mm |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 250 mm × 400 mm × 500 mm |
| Net Weight | 35 kg |
| Brand | Qinji |
|---|---|
| Model | QJRZ-45 |
| Origin | Shanghai, China |
| Temperature Range | 50–450 °C |
| Temperature Stability | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Barrel Diameter | Φ9.55 mm ± 0.025 mm |
| Die Orifice Diameters | Φ2.095 mm ± 0.005 mm and Φ1.180 mm ± 0.010 mm |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 250 mm × 400 mm × 500 mm |
| Net Weight | 35 kg |
| Compliance | GB/T 3682, ISO 1133 |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | QJRZ-45 |
| Price | USD 2,800 (FOB Shanghai) |
| Temperature Range | 50–400 °C |
| Temperature Stability | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Barrel Diameter | Φ9.55 mm ±0.025 mm |
| Die Orifice Diameters | Φ2.095 mm ±0.005 mm and Φ1.180 mm ±0.010 mm |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 250 mm × 400 mm × 500 mm |
| Net Weight | 35 kg |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | QJRZ45 |
| Price Range | USD 1,050 – 2,100 |
| Test Method | Gravimetric (Mass Flow Rate) |
| Type | Standard-Configuration Melt Flow Indexer |
| Temperature Range | 100–450 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Barrel Diameter | Φ9.55 mm ±0.025 mm |
| Die Orifice Diameters | Φ2.095 mm ±0.005 mm and Φ1.180 mm ±0.010 mm |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 250 mm × 400 mm × 500 mm |
| Net Weight | 35 kg |
| Compliance | GB/T 3682–2000 & ISO 1133:2005 |
| [Brand | Qinji |
|---|---|
| Model | QJWK-507 |
| Temperature Range | Ambient to 300 °C |
| Heating Rate Options | (12 ±1) °C/6 min or (5 ±0.5) °C/6 min |
| Temperature Accuracy | ±1 °C |
| Deformation Measurement Range | 0–1 mm |
| Deformation Resolution | 0.01 mm |
| Heating Medium | Methyl Silicone Oil |
| Heating Power | 4 kW |
| Cooling Method | Natural cooling above 150 °C |
| Power Supply | AC 220 V, 20 A, 50 Hz |
| Dimensions (L×W×H) | 540 × 520 × 1360 mm |
| Compliance | GB/T 1633, GB/T 1634, GB 8802, ISO 75, ISO 306, ISO 2507] |
| (Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QJCXS-43 |
| Price | USD 9,100 |
| Test Temperature Range | −70 °C to 0 °C |
| Impact Velocity | 2.0 m/s ±0.2 m/s |
| Temperature Stability During Test (3 min) | ±0.5 °C |
| Impact Pin to Clamp Lower Edge Distance | 11.0 mm ±0.5 mm |
| Dimensions (W×D×H) | 700 mm × 700 mm × 1300 mm |
| Power Consumption | 1100 W) |