Industry-specific Instruments
Filter
Showing 4021–4050 of 6344 results
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | PLD-510C |
| Input Power | <1600 W |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Temperature Control Method | Microcontroller-based digital intelligent control |
| Temperature Range | +30 °C to –68 °C |
| Temperature Stability | ±0.5 °C |
| Cooling Time (30 °C → –68 °C) | ≤100 min |
| Bath Configuration | Dual-sample immersion bath (2-position cold bath槽) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-511A |
| Power Supply | 220 V AC, 50 Hz |
| Input Power | 500 W (Heating: 2 × 100 W) |
| Ultimate Vacuum | ≥0.09 MPa |
| Air Extraction Rate | ≥20 L/min |
| Brand | PULUODY |
|---|---|
| Model | PLD-6001 |
| Origin | Shaanxi, China |
| Sensor Technology | 8th-Generation Dual-Laser Narrow-Beam Light Obscuration |
| Detection Range | 1–500 µm (optional 0.03–3000 µm) |
| Resolution | >95% (ChP 2015/2020 calibrated) |
| Channel Count | 1000 adjustable channels (user-definable from 4 to 128 size bins) |
| Flow Control | Precision metering piston pump + ultra-precise electromagnetic flow regulation |
| Sampling Accuracy | <±1% |
| Measurement Accuracy | <±3% (typical) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Sample Temperature Range | 0–80 °C |
| Environmental Operating Range | −15–50 °C |
| Compliance | ChP 2020 Appendix 0903, USP <788>, <789>, <797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, ISO 21510, GB/T 11446.9–2013, GB 8368, YBB 00272004–2015 |
| Software | V8.9 Particle Analysis Suite (PC & embedded touchscreen), 21 CFR Part 11 compliant with audit trail, electronic signature, role-based 5-level access control, data backup/recovery, and power-fail protection |
| Calibration Standards | JJG 1061, NIST-traceable latex spheres, ISO 21501-4 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601 |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Laser Source | Dual-narrow-beam laser diode array (8th-generation) |
| Sensor Resolution | 1000 channels, down to 0.01 µm |
| Flow Control | Precision metering piston pump + ultra-precise electromagnetic flow regulation |
| Sample Volume Accuracy | < ±1% |
| Counting Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Channel Flexibility | User-definable size bins (e.g., 4–70 µm(c), 1–100 µm, or 0.1 µm(c)) |
| Flow Rate Range | Sample: 5–150 mL/min |
| Rinse | 5–500 mL/min |
| Fluid Temperature Range | 0–80 °C |
| Ambient Operating Range | −15–50 °C |
| Compliance | ChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, ISO 11171, GB/T 11446.9–2013, YBB00272004–2015, GB 8368 |
| Software | V8.9 Analytical Suite (PC & embedded touchscreen), FDA 21 CFR Part 11 compliant (audit trail, electronic signature, role-based 5-level access, data backup/restore, power-fail recovery) |
| Calibration Standards | NIST-traceable polystyrene latex (PSL) spheres, JJG 1061–2019, ISO 21501-4 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PLD-601 |
| Price | USD 26,500 (FOB) |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor |
| Particle Size Range | 1–500 µm (optional 0.03–3000 µm) |
| Channel Count | 1000 customizable channels (down to 0.01 µm resolution) |
| Flow Accuracy | < ±1% |
| Volumetric Precision | < ±3% (typical) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Resolution | >95% (CP 2015/2020 calibration), <10% (USP/ISO 21501 calibration) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Fluid Temperature Range | 0–80 °C |
| Ambient Operating Temperature | −15–50 °C |
| Compliance | CP 2020 Method 0903, GB 8368, USP <788>, <789>, <797>, EP 10.0, BP 2019, JP 17, ISO 21501-2, ISO 11171, ASTM D6786, FDA 21 CFR Part 11 (audit trail, e-signature, role-based 5-level access) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PLD-601 |
| Price | USD 29,500 (approx.) |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Particle Sensing |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Control System |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-Traceable Latex Spheres |
| Regulatory Compliance | ChP 2020 <0903>, USP <788>/<789>, EP 10.0, BP 2019, JP 17, WHO IntPh IV, YBB00272004-2015, GB/T 11446.9-2013, ISO 21510, ISO 11171 |
| Software | V8.9 Regulatory-Grade Analysis Suite (FDA 21 CFR Part 11 Compliant) |
| Particle Size Range | 1–500 µm (optional extended range: 0.03–3000 µm) |
| Channel Resolution | 1000-user-definable channels (min. bin width: 0.01 µm) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Temperature Range (Fluid) | 0–80 °C |
| Accuracy | ±3% typical (per ChP 2020) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated), >90% (ISO 21501-4 calibrated) |
| Data Integrity | Audit Trail, Electronic Signature, Role-Based 5-Tier User Permissions, Auto-Backup/Restore, Power-Fail Recovery |
| Interface | Color LCD Touchscreen + Optional Wireless Keyboard/Mouse |
| Sample Compatibility | Aqueous & non-aqueous sterile injectables, lyophilized powders, ophthalmic solutions, vaccines, WFI, pharmaceutical packaging materials, infusion devices, terminal filters, CMP slurries, ultrapure water, electronic-grade chemicals |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PLD-601 |
| Price | USD 32,500 (FOB) |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Particle Sensing |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Regulation |
| Software | V8.9 Regulatory-Compliant Analysis Suite (PC & Touchscreen) |
| Calibration Standards | JJG1061, ISO 21501-4, NIST-Traceable Latex Spheres |
| Regulatory Alignment | ChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21510, GB/T 11446.9-2013, GB 8368 |
| Particle Size Range | 1–500 µm (optional extension: 0.03–3000 µm) |
| Channel Count | 1000 adjustable channels (user-definable from 4 to 128 size bins) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Temperature Range (Fluid) | 0–80 °C |
| Accuracy | ±3% typical (per ChP 2020) |
| Resolution | >95% (ChP-calibrated), >90% (ISO 21501-4 calibrated) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Sampling Precision | <±1% volumetric repeatability |
| Data Integrity | 5-Tier User Permission Architecture, Audit Trail, Electronic Signature, Full 21 CFR Part 11 Compliance, Auto-Backup/Restore, Power-Fail Recovery |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601* |
| Sensor | 8th-generation dual-laser narrow-beam particle sensor |
| Detection Principle | Light Blockage (Optical Obstruction) |
| Measurement Range | 1–500 µm (optional 0.03–3000 µm) |
| Channel Count | 1000 adjustable channels (down to 0.01 µm resolution) |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Sample Temperature Range | 0–80 °C |
| Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated), <10% (USP/ISO 21501-calibrated) |
| Compliance | ChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, ISO 11171, GB/T 11446.9-2013, GB 8368, YBB 00272004-2015 |
| Software | V8.9 Regulatory Edition with 5-level user permissions, audit trail, electronic signature, 21 CFR Part 11 compliance, data backup/recovery, and power-fail protection |
| Interface | Touchscreen + optional wireless keyboard/mouse |
| Calibration Standards | JJG 1061, NIST-traceable latex spheres, or ISO 21501-4 reference materials |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601 |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor |
| Measurement Range | 1–500 µm (optional 0.03–3000 µm) |
| Channel Resolution | 1000 customizable channels (down to 0.01 µm bin width) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Temperature Range (Fluid) | 0–80 °C |
| Compliance | ChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21501-2, ISO 11171, GB/T 11446.9–2013, GB 8368, FDA 21 CFR Part 11 (audit trail, e-signature, role-based 5-level access), GLP/GMP-ready software architecture |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PLD-601 |
| Price | USD 34,500 (FOB Shanghai, ex-factory) |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Particle Sensor |
| Flow Control | Precision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Control System |
| Software Compliance | FDA 21 CFR Part 11, ALCOA+ Data Integrity, Audit Trail, Electronic Signature, 5-Level User Permission Management |
| Calibration Standards | ISO 21501-4, JJG 1061, NIST-Traceable Latex Standards |
| Detection Range | 1–500 µm (optional 0.03–3000 µm) |
| Channel Count | 1000 High-Resolution Channels (0.01 µm resolution increment) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Temperature Range | Fluid 0–80 °C |
| Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Repeatability | ≤2.5% coincidence error at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated) |
| Regulatory Alignment | ChP 2020 <0903>, USP <788>, <789>, <797>, EP 10.0, BP 2019, JP 17, WHO IntPh IV, YBB00272004-2015, GB/T 11446.9-2013, ISO 21510, ISO 4406, NAS 1638, ASTM D6786 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601 |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Particle Sensor |
| Flow Control | Precision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Control System |
| Measurement Range | 1–500 µm (optional 0.03–3000 µm) |
| Resolution | >95% (ChP 2015/2020 calibrated) |
| Channel Count | 1000 user-definable channels (down to 0.01 µm bin resolution) |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Sample Temperature Range | 0–80 °C |
| Accuracy | ±3% typical (particle count), ±1% volumetric delivery |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Compliance | ChP 2020 <0903>, USP <788>, <789>, <797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, GB/T 11446.9–2013, GB 8368, YBB 00272004–2015, FDA 21 CFR Part 11 (audit trail, e-signature, role-based 5-level access, data backup/recovery, power-fail protection) |
| Software | PULUODY V8.9 PC & Integrated Touchscreen Edition |
| Interface | Bilingual (English/Chinese) GUI |
| Calibration Standards | NIST-traceable latex spheres, ISO 21501-4, JJG 1061 |
| Metrology Support | Accredited by NWMS (China National Institute of Metrology Northwest Center) & DFKW Level-1 Particle Metrology Station No. 116 |
| Key | Brand: PULUODY |
|---|---|
| Model | PLD-601 |
| Origin | Shaanxi, China |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor |
| Measurement Range | 1–450 µm (optional extension to 0.03–3000 µm) |
| Channel Count | 1000 adjustable size channels |
| Flow Rate (Sampling) | 5–150 mL/min |
| Flow Rate (Cleaning) | 5–500 mL/min |
| Accuracy | ±5% typical (per ChP 2020 & USP <788>) |
| Resolution | >95% (ChP-calibrated), <10% RSD (USP/ISO 21501-calibrated) |
| Sample Temperature Range | 0–80 °C |
| Environmental Operating Range | 0–50 °C |
| Compliance | ChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, ISO 11171, GB/T 11446.9-2013, YBB00272004-2015, GB 8368 |
| Software | V8.9 PC & Embedded Analysis Suite with 21 CFR Part 11 Compliance (Audit Trail, Electronic Signature, Role-Based 5-Tier Access, Data Backup/Restore, Power-Fail Recovery) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PLD-601 |
| Pricing | Upon Request |
| Sensor Technology | 8th-Generation Dual-Laser Narrow-Beam Particle Sensor |
| Flow Control | Precision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Control System |
| Software | V8.9 Integrated Analysis Software (PC & Touchscreen) |
| Compliance | ChP 2020 <0903>, USP <788>/<789>/<797>, EP 10/9.0/8.0, BP 2019, JP 17, ISO 21501, ISO 11171, GB/T 11446.9–2013, YBB 00272004–2015, GB 8368 |
| Detection Range | 1–500 µm (optional 0.03–3000 µm) |
| Channel Count | 1000 user-definable channels (min. 4, max. 1000) |
| Resolution | >95% (ChP-calibrated), <10% (USP/ISO-calibrated) |
| Sampling Accuracy | <±1% |
| Measurement Accuracy | ±3% typical |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Fluid Temp. Range | 0–80 °C |
| Ambient Temp. Range | −15–50 °C |
| Calibration Standards | JJG 1061, ISO 21501, NIST-traceable latex spheres |
| Data Integrity | FDA 21 CFR Part 11 compliant (audit trail, electronic signature, role-based 5-level access, backup/restore, power-fail recovery) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PLD-601 |
| Price | USD 23,500 (approx.) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China (Manufactured in China) |
| Manufacturer Type | Direct Manufacturer |
| Model | PLD-601-B |
| Price | USD 29,500 (approx.) |
| Detection Principle | Light Obscuration (LO) |
| Calibration Standards | USP <788>, USP <789>, EP 2.9.19, JP 6.04, ChP 2015 Vol I Appendix IX R |
| Measurement Range | 0.03 µm – 3000 µm (configurable sub-ranges) |
| Channel Count | 1000 adjustable size channels |
| Sample Volume | 1 mL to unlimited (programmable) |
| Flow Accuracy | ±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤3% at 40,000 particles/mL |
| Resolution | ≥95% (ChP 2015), <10% (USP <788>, ISO 21501-4, JJG 1061) |
| Viscosity Range | 0–99 mm²/s (pressurized up to 500 mm²/s) |
| Flow Rate | 5–150 mL/min (sampling), 5–500 mL/min (flushing) |
| Temperature Range | Fluid 0–80 °C |
| Data Storage | ≥20,000 test records (expandable via USB) |
| Compliance | FDA 21 CFR Part 11 ready (audit trail & electronic signature optional), GLP/GMP traceable operation |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PLD-601-D |
| Price | USD 26,500 (FOB) |
| Sensor Generation | 8th-generation dual-laser narrow-beam particle sensor |
| Flow Control | Precision metering piston pump + ultra-precise electromagnetic flow control system |
| Detection Range | 0.01 µm to 450 µm (customizable sub-ranges: e.g., 1–100 µm, 4–70 µm(c), or 0.1 µm(c)) |
| Channel Count | 1000 user-definable size channels |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Sample Temperature Range | 0–80 °C |
| Ambient Operating Temperature | 0–50 °C |
| Accuracy | ±5% typical (per USP <788>, ISO 21501) |
| Coincidence Limit | ≤5% error at 1000 particles/mL |
| Resolution | >95% (ChP 2015/2020 calibrated) |
| Compliance | FDA 21 CFR Part 11 (audit trail, electronic signature, role-based 5-level access, data backup/recovery, power-fail protection) |
| Software | V8.9 Particulate Analysis Suite (PC + embedded touchscreen) |
| Calibration Standards | JJG 1061, ISO 21501, NIST-traceable latex spheres |
| Regulatory Alignment | ChP 0903, USP <788>/<789>/<797>, EP 10.0/9.0/8.0, BP 2019, JP 17, IP 2015, WHO IntPh IV, YBB00272004-2015, GB/T 11446.9-2013, ISO 4406, NAS 1638, ISO 11171, MIL-STD-1246, SAE AS749D |
| Metrology Support | Accredited by NW National Metrology Center (CNAS) and Defense Science & Technology Commission Particle Metrology Station No. 116 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PLD-601X |
| Price | USD 26,500 (FOB) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601ZY |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Particle Sensing |
| Channel Count | 1000 adjustable channels |
| Detection Range | 1–450 µm |
| Minimum Detectable Size | 0.01 µm (c) |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Sample Temperature Range | 0–80 °C |
| Ambient Operating Temperature | 0–50 °C |
| Accuracy | ±5% typical (per USP <788>, ISO 21501) |
| Coincidence Limit | ≤5% at 1000 particles/mL |
| Resolution | >95% (ChP 2020 calibration), <10% (USP/ISO 21501 calibration) |
| Flow Control | Precision metering piston pump + ultra-precise electromagnetic flow regulation |
| Software Compliance | FDA 21 CFR Part 11, ALCOA+ principles, audit trail, electronic signature, data backup & restore, power-fail recovery |
| Regulatory Standards Supported | ChP 0903 (2015/2020), USP <788>/<789>/<797>, EP 10.0/9.0/8.0, BP 2019/2018, JP 17/16/15, WHO IntPh IV, YBB00272004-2015, ISO 4406, ISO 11171, NAS 1638, SAE AS4059, MIL-STD-1246C, GB/T 14039, DL/T 432, GJB/T 420A/B, GB/T 18854 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PLD-6532A |
| Pricing | Available Upon Request |
| Standard Compliance | GB/T 6532–2019 |
| Temperature Control | Digital PID-controlled heating system (range: ambient to 80 °C, ±0.5 °C stability) |
| Extraction Configuration | Dual independent extraction units with synchronized solvent delivery |
| Pressure Regulation | Precision digital pressure controller (0–0.6 MPa, resolution 0.01 MPa) |
| Display Interface | Backlit LCD with real-time parameter monitoring |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-6536B |
| Heating Power | 0–1200 W (continuously adjustable) |
| Heating Mantle Vertical Adjustment Range | 35 mm |
| Flask Support Plate Aperture Options | Ø37.5 mm and Ø50 mm |
| Condensate Bath Temperature Range (with chiller) | –5 to 80 °C |
| Power Supply | AC 220 V, 50 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-6536B |
| Heating Power | 0–1200 W (continuously adjustable) |
| Heating Mantle Vertical Adjustment Range | 35 mm |
| Flask Support Plate Apertures | Ø37.5 mm and Ø50 mm |
| Condensate Bath Temperature Range | –5 °C to 80 °C (with integrated refrigeration unit) |
| Power Supply | AC 220 V, 50 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-6536C |
| Heating Power | 0–2000 W (continuously adjustable) |
| Heating Chamber Vertical Adjustment Range | 35 mm |
| Flask Support Plate Aperture | Ø37.5 mm |
| Temperature Control Accuracy | ±0.5 °C |
| Temperature Display Resolution | 0.1 °C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Refrigeration System | Imported Compressor |
| Condensate Bath Temperature Range | 0–80 °C |
| Compliance | GB/T 6536, ASTM D86, ISO 3405 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | PLD-CX |
| Measurement Parameters | Gasoline Octane Number (RON), Diesel Cetane Number |
| Portability | Portable |
| Measurement Range | 40–120 (Octane), 20–100 (Cetane) |
| Measurement Accuracy | ±0.5–1.0 units |
| Measurement Time | ≤10 seconds per sample |
| Sample Volume | 10 mL |
| Compliance Standard | GB/T 18339–2001 (Gasoline Octane Number Determination by Dielectric Constant Method) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PLD-CX-a |
| Measurement Parameters | Gasoline Research Octane Number (RON), Diesel Cetane Number (CN) |
| Portability | Handheld |
| Measurement Range | 40–120 (RON/CN scale) |
| Accuracy | ±0.5 RON/CN |
| Measurement Time | ≤10 seconds |
| Sample Volume Required | 10 mL |
| Operating Environment | 0–30 °C, ≤85% RH |
| Repeatability | ±0.2 RON |
| Reproducibility | ±0.4 RON |
| Resolution | 0.1 RON/CN |
| Response Time | <1 s |
| Power Input | 100–240 VAC, 50/60 Hz |
| DC Output | 5 VDC / 1000 mA |
| Compliance Standard | GB/T 18339–2001 (Gasoline Octane Determination by Dielectric Constant Method) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-FX-801PL |
| Detection Principle | Dual-mode (Light Scattering + Light Obscuration) |
| Sensor Generation | 8th-generation dual-laser narrow-beam particle sensor |
| Measuring Range | 0.5–100.0 µm |
| Customizable Channels | 1–100 µm or 4–70 µm (c), down to 0.1 µm (c) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | <±3% typical |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision metering pump with dual-stage automatic dilution |
| Data Output | 4–20 mA analog interface with configurable alarm trigger |
| Calibration Standards | JJG 1061, ISO 21501, or NIST-traceable latex spheres |
| Software | V8.3 Integrated Analysis & Calibration Suite (PC + touchscreen UI) |
| Compliance Support | GLP/GMP audit trail logging, FDA 21 CFR Part 11-ready configuration options |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Model | PLD-IGS-2025 |
| Origin | Shaanxi, China |
| Housing Material | 316L Stainless Steel |
| Sample Volume | 1 L |
| Maximum Working Pressure | ≥1.3 MPa |
| Vacuum Pump Control Threshold | 1.3 MPa (auto-shutoff with overpressure cutoff and audible/visual alarm) |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory workflows, compatible with ASTM D6164 (gas sampling for radionuclide analysis), USP <661>, and IAEA Safety Standards RS-G-1.7 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PLD-IGS-2025 |
| Price | USD 3,650 (FOB) |
| Vessel Material | 316L Stainless Steel |
| Vessel Capacity | 1 L |
| Maximum Working Pressure | ≥1.3 MPa |
| Vacuum Pump Control Threshold | 1.3 MPa (auto-shutoff with audible/visual alarm) |
| Safety Features | Overpressure cutoff, leak-resistant isolation valve, pressure relief mechanism |
| Compliance | Designed to meet ASTM D6159–22 (Standard Practice for Sampling Gaseous Effluents), ISO 8573-1:2010 (Compressed Air – Part 1: Contaminants and Purity Classes), and IAEA Safety Standards Series No. SSG-24 (Radiation Protection and Safety of Radiation Sources) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PLD-MPCS2.0 |
| Price | USD 51,200 (FOB China) |
| Compliance | ChP 2020 Appendix 0903 Method 2 (Microscopic Particle Counting), USP <788>, USP <789>, EP 8.0, ISO 21501-4, ISO 21510, GB/T 11446.9-2013 |
| Measurement Principle | Bright-field Microscopy + Digital Image Analysis |
| Particle Detection Range | 1–500 µm |
| Magnification | 40×–1000× |
| Resolution | 0.1 µm |
| Repeatability Error | <5% (excluding sample preparation variability) |
| CCD Sensor | 3 MP monochrome digital camera |
| Calibration Traceability | Northwest Metrology & Testing Center (Civil Products) |
| Software Platform | Windows XP/7/10 (32/64-bit), RS232/USB interface |
| Image Processing Speed | <1 sec per frame segmentation |
| Segmentation Success Rate | >93% |
| Accuracy | ±3% typical (ChP 2020 reference), >95% resolution (ChP 2020), <10% misclassification rate (USP/ISO 21501-4) |
| Reporting | ASTM E2457-compliant output, GLP audit trail enabled, FDA 21 CFR Part 11 optional module available |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-MPCS2.0 |
| Magnification Range | 40×–1000× |
| Resolution | 0.1 µm |
| Measurement Range | 1–500 µm |
| Repeatability Error | <5% |
| Accuracy | ±3% (typical) |
| Particle Segmentation Speed | <1 s |
| Segmentation Success Rate | >93% |
| Brand | PULUODY |
|---|---|
| Model | PLD-MPCS2.0 |
| Origin | Shaanxi, China |
| Microscope Magnification | 40×–1000× |
| Measurement Range | 1–500 µm |
| Resolution | 0.1 µm |
| Repeatability Error | <5% |
| CCD Camera | 3 MP |
| Particle Segmentation Speed | <1 s |
| Segmentation Success Rate | >93% |
| Accuracy | ±3% (typical) |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Resolution Compliance | >95% (ChP 2020), <10% (USP <788>, ISO 21501) |
| Interface | RS232 or USB |
| Software Platform | Windows 2000/XP |