Industry-specific Instruments
Filter
Showing 4561–4590 of 6308 results
| Key | Brand: SETA |
|---|---|
| Origin | United Kingdom |
| Model | 12200-3 |
| Temperature Range | 140–260 °C (±5 °C) |
| Heating Power | 2 × 1 kW |
| Over-Temperature Cut-Off | Adjustable at 280 °C |
| Dimensions | 45 × 35 × 50 cm |
| Weight | 45 kg |
| Test Positions | 5 |
| Evaporation Medium | Compressed Air or Steam |
| Integrated Steam Generator | Yes |
| Control Type | Digital Temperature Controller |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 14020-8 |
| Bath Quantity | 2 |
| Cylinders per Bath | 2 (total 4 × 1000 mL) |
| Diffuser Material Options | Stainless Steel or Sintered Glass |
| Flowmeters | 2 per bath |
| Temperature Range | Ambient to 100 °C ±0.5 °C |
| Power Consumption | 3 kW |
| Dimensions (W×D×H) | 70 × 48 × 40 cm |
| Weight | 50 kg |
| Compliance | ASTM D892, ISO 6247, IP 146, BS 2000-146, GB/T 12579, NF T60-129, JIS K2518, FTM 791-3211 |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 15200-5 |
| Temperature Range | Ambient to 160 °C |
| Temperature Stability | ±0.1 °C |
| Bath Volume | 72 L |
| Test Positions | 2 |
| Rotation Speed | 100 rpm |
| Voltage | 220–240 V, 50/60 Hz |
| Power Consumption | 3.2 kW |
| Dimensions (W×D×H) | 113 × 78 × 88 cm |
| Weight | 87 kg |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 15400-4 |
| Bath Volume | 60 L |
| Test Temperature | 100 °C |
| Number of Bomb Positions | 4 |
| Maximum Bomb Charging Pressure | 1380 kPa |
| Cooling Method | Water-cooled bath |
| Voltage | 110/120 V or 220/240 V, 50/60 Hz |
| Power Consumption | 3 kW |
| Dimensions (W×D×H) | 135 × 83 × 77 cm |
| Weight | 87 kg |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 15400-5 |
| Bath Volume | 60 L |
| Operating Temperature | 100 °C ± 0.1 °C |
| Test Positions | 4 |
| Maximum Bomb Charging Pressure | 1380 kPa |
| Cooling Method | Dedicated Water-Cooled Quenching Trough |
| Voltage | 110/120 V or 220/240 V, 50/60 Hz |
| Power Consumption | 3 kW |
| Dimensions (W×D×H) | 135 × 83 × 77 cm |
| Weight | 87 kg |
| Compliance | ASTM D525, D873, IP 40, IP 138, ISO 7536, EN 7536, GB/T 8018, JIS K2287, NF M07-012/013, FTM 791-3352/3354, BS 2000-40/138 |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 15550-2 |
| Temperature Range | Ambient to 150 °C |
| Temperature Stability | ±0.1 °C |
| Bath Medium | Water or Oil |
| Bath Volume | 35 L |
| Power Rating | 1500 W |
| Voltage Options | 110/120 V or 220/240 V, 50/60 Hz |
| Dimensions (W×D×H) | 41 × 45 × 33 cm |
| Weight | 10 kg |
| Test Positions | 4 |
| Construction Material | Stainless Steel |
| Controller Type | Digital with Over-Temperature and Low-Level Safety Interlocks |
| Optional Accessory | Automated Pressure Monitoring Module |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 15840-0 |
| Standards Compliance | ASTM D3427, IP 313, BS 2000-313, ISO 9120, DIN 51381, NFT 60-149, SH/T 0308 |
| Temperature Range | Ambient to 75 °C |
| Temperature Stability | ±0.2 °C |
| Touchscreen Interface | 7-inch LCD with Embedded Control Software |
| LIMS Connectivity | Yes |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 16120-2 |
| Standard Compliance | ASTM D4870, IP 375 (Procedure A), IP 390 (Procedure A), ISO 10307-1 & ISO 10307-2, BS 2000-375, NF M07-063, SH/T 0701, SH/T 0702 |
| Sample Mass | 10 g |
| Flask Capacity | 500 mL |
| Filter Paper Requirement | 2 sheets per test |
| Operating Temperature | 80 °C (sample heating), 100 °C (steam jacket) |
| Vacuum Pressure | 40 kPa |
| Cooling Water | Ambient temperature |
| Dimensions | 40 × 47 × 18 cm |
| Weight | 8 kg |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 16670-0 |
| Heating Method | Solid (metal block) |
| Temperature Range | Ambient to 100 °C |
| Test Positions | 4 |
| Voltage | 200–240 V, 50/60 Hz |
| Power Consumption | 3 kW |
| Dimensions (W×D×H) | 30 × 60 × 28 cm |
| Weight | 65 kg |
| Compliance | ASTM D525, D873, D2274, D4310, D7462 |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 22100-0 |
| Maximum Operating Pressure | 1400 kPa (200 psi) |
| Temperature Range | −20 °C to +60 °C |
| Test Chamber Burst Pressure | 2800 kPa |
| Compliance | ASTM D1657, BS EN ISO 3993, IP 235, SH/T 0221 |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 22210-3 |
| Temperature Range | 5°C to 90°C (ambient referenced) |
| Temperature Uniformity | ±0.1°C at 37.8°C |
| Bath Volume | 80 L |
| Capacity | Up to six RVP test bombs |
| Power Supply | 220/240 V, 50/60 Hz |
| Power Consumption | 2.2 kW |
| Dimensions (W × D × H) | 77 × 55 × 51 cm |
| Weight | 70 kg |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 22220-4 |
| Temperature Range | Ambient to 100 °C |
| Temperature Stability | ±0.2 °C |
| Bath Volume | 38 L |
| Voltage | 110–120 V / 220–240 V, 50/60 Hz |
| Power Rating | 1.4 kW |
| Dimensions (W×D×H) | 60 × 35 × 33 cm |
| Weight | 9 kg |
| Test Positions | 3 |
| Control System | Digital PID temperature controller with LED display |
| Internal Agitation | Integrated mechanical stirrer |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 35000-0 |
| Test Method | Closed-Cup (Pensky-Martens) |
| Temperature Range | +5 °C to 400 °C |
| Temperature Resolution | ±0.1 °C |
| Heating Rates | 1.0, 1.3, 3.0, 5.5 °C/min (standard) |
| Stirring Speed | 105 or 250 rpm |
| Ignition Options | Electric spark or gas flame (user-selectable in menu) |
| Atmospheric Pressure Correction | Integrated digital barometer with automatic flash point compensation |
| Display | 8.4-inch color touchscreen (Chinese UI) |
| Data Storage | ≥2000 test records, 30 programmable methods |
| Connectivity | Ethernet and RS-232 |
| Dimensions | 38.5 × 24 × 50 cm |
| Weight | 25 kg |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 99700-4 |
| Conductivity Range | 0.0 to 430.0 g/m³ (as NaCl) |
| Temperature Range | −20 °C to +150 °C |
| Power Supply | 9 V alkaline battery or universal AC adapter (110–240 V, 50/60 Hz) |
| Dimensions | 200 × 70 × 35 mm |
| Weight | 1.6 kg |
| Compliance | ASTM D3230, IP 265 |
| Interface | RS232 serial output |
| Brand | SetaAnalytics |
|---|---|
| Origin | United Kingdom |
| Model | SA4000-4 |
| Compliance | ASTM D7621, IP 570 |
| Measurement Range | 0–250 mg/kg H₂S (ppm) |
| Analysis Time | 15 min |
| Operating Temperature | 5–40 °C |
| Sample Volume | 1 mL / 2 mL / 5 mL |
| Viscosity Limit | ≤3000 mm²/s at 40 °C |
| Interface | RS232 |
| Power | 60 W |
| Dimensions | 21 × 30 × 41 cm |
| Weight | 8 kg |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | SA5000-2 |
| Measurement Range | 10–400 mg/kg FAME in Aviation Turbine Fuels |
| Analysis Time | ≤20 min per sample |
| Sample Volume | ≤50 mL |
| Operating Temperature | 5–40 °C (max. 80% RH) |
| Dimensions | 36 × 37 × 45 cm |
| Weight | 16 kg |
| Interface | USB |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 81000-2 |
| Analysis Method | Reid Vapor Pressure (RVP) |
| Pressure Range | 0–200 kPa |
| Temperature | 37.8 °C ± 0.1 °C |
| Sample Volume | 3 mL |
| Vapor-to-Liquid Ratio | 4:1 |
| Pressure Resolution | 0.1 kPa |
| Accuracy | ±0.5 kPa |
| Vacuum Requirement | < 0.01 kPa |
| Interface | RS232C |
| Power | 110/120 V or 220/240 V, 50/60 Hz, 70 W |
| Dimensions | 37 × 13 × 20 cm |
| Weight | 3.5 kg |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 82000-2 |
| Test Method | Closed-Cup (Rapid Equilibrium / Constant Rate of Rise) |
| Automation Level | Fully Automatic |
| Temperature Range | −20 °C to 130 °C or Ambient +5 °C to 300 °C |
| Sample Volume | 2–4 mL |
| Ignition Source | Selectable Electric Spark or Gas Flame |
| Compliance | ASTM D3278, D3828, D7236 |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | SETAFLASH Series 3 |
| Detection Method | Closed-Cup |
| Temperature Range | 0 °C to 300 °C |
| Ignition Mode | Electric or Gas Ignition |
| Compliance Standards | ISO 3679 |
| Sample Volume | 2 mL (for samples with expected flash point ≤100 °C), 4 mL (for >100 °C) |
| Cooling Time | ≤4 min (from 80 °C to 20 °C, optional) |
| Test Duration | 1–99 min |
| Interface Options | RS232, USB, LAN |
| Power | 200 W / 300 W |
| Voltage | 100–250 V AC, 50/60 Hz |
| Cup Materials | Anodized Aluminum, Corrosion-Resistant Stainless Steel |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SG-2003 |
| Pricing | Available Upon Request |
| Key | Origin: Shandong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SGD-IV |
| Pricing | Available Upon Request |
| Power Supply | 220 V, 50 Hz |
| Dimensions (L×W×H) | 421 × 342 × 230 mm |
| Weight | 12 kg |
| Display | Integrated LCD Panel |
| Sensitivity | 0.01% (w/v, expressed as glucose) |
| Linear Range | 0.01–1.00% (w/v, expressed as glucose) |
| Assay Time | ≤ 3 minutes |
| Brand | Shanda |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FERRITE-CHECK 140 |
| Price | USD 4,200 (approx.) |
| Measurement Range | 1–100 Fe% / 1–140 Ferrite Number (FN) |
| Accuracy | ±<5% of reading |
| Operating Temperature | 0–50 °C |
| Calibration Standards | Three NIST-traceable ferrite reference standards |
| Power Supply | Rechargeable lithium-ion battery |
| Compliance | DIN EN ISO 8249:2018 |
| Brand | Shanda |
|---|---|
| Model | SD-2TA |
| Type | Manual Hydraulic Powder Press |
| Maximum Pressure | 2 Ton (25 MPa) |
| Piston Diameter | Ø32 mm |
| Max Piston Stroke | <30 mm |
| Pressure Gauge | Analog Dual-Scale (MPa & Ton), Accuracy: ±1 MPa |
| Pressure Stability | ≤1 MPa/10 min |
| Worktable Diameter | Ø70 mm |
| Working Space | 90 × 120 mm |
| Overall Dimensions | 210 × 170 × 370 mm |
| Net Weight | ~11 kg |
| Compliance | Designed for GLP-aligned lab environments |
| Brand | Shanda |
|---|---|
| Origin | Shandong, China |
| Model | SD-CL9 |
| Measurement Principle | Coulometric Titration (per GB/T 214–2007) |
| Sample Types | Coal, Coke, Activated Carbon, Petroleum Coke |
| Temperature Control | Microprocessor-regulated High-Temperature Furnace (up to 1150 °C) |
| Electrolytic Cell | Integrated Dual-Platinum Electrode Cell |
| Display | 7-inch TFT LCD Touch Interface |
| Power Supply | AC (220 ± 22) V, 50 Hz |
| Max Power Consumption | ≤3 kW |
| Safety Features | Automatic Silicon Carbide Tube Protection, Overcurrent Protection, Real-time Temperature Compensation |
| Data Management | Non-volatile Memory Storage, USB Export, Print Support (via RS232 or USB thermal printer) |
| Compliance | Designed to meet requirements of GB/T 214–2007, ASTM D3177, ISO 4293, and supports GLP-compliant audit trails when paired with optional PC software |
| Brand | Shanda |
|---|---|
| Model | SD-FSX |
| Origin | Shandong, China |
| Category | Rubber & Plastic Industry–Specific Instrument |
| Compliance | GB/T 6030–2006 |
| Imaging Sensor | 5 MP CMOS |
| Resolution Options | 640×480, 1024×768, 1280×1024, 2592×1944 |
| Interface | USB 2.0 |
| Calibration | Integrated micrometer scale with pixel-to-µm mapping |
| Output Formats | PDF, PNG/JPEG, Excel (.xlsx) |
| Software Compatibility | Windows XP/7/10 (32/64-bit) |
| Image Segmentation Modes | Automated thresholding + manual ROI selection |
| Standard Reference Libraries | ISO-aligned carbon black dispersion image library + user-customizable library |
| Data Export | Particle count, equivalent circular diameter (µm), projected area (µm²), grayscale histogram, particle size distribution curve, dispersion rating (0–10 scale per GB/T 6030) |
| Brand | Shanda |
|---|---|
| Model | SD-GCT-28A |
| Sample Capacity | 28 positions |
| Power Supply | 220–230 V, 50 Hz |
| Operating Temperature Range | 5–40 °C |
| Relative Humidity | 10–85% |
| Temperature Control Accuracy | 25 °C ± 2 °C |
| Software | PC-based workstation software with real-time hardware monitoring, error code display, Excel export, color-coded batch labeling, and historical data retrieval |
| Optional Accessories | Rice sample preparation mill, dedicated PC, water-cooling unit |
| Brand | Shanda |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Model | SD-HQMG |
| Price | USD 1,390 (FOB) |
| Function Type | Multi-analyte Detection Platform |
| Sample Scope | Universal for Cereals, Oilseeds, Feed Matrices, and Processed Food Commodities |
| Main Controller | ARM Cortex-A7 |
| Detection Channels | ≥12 independent optical channels |
| Display | 10.1-inch HD vertical capacitive touchscreen (1280×800) |
| Communication Interfaces | Integrated Wi-Fi (802.11 b/g/n), RJ45 Ethernet port, USB 2.0 host/device |
| Power Supply | DC 12 V — compatible with vehicle power outlets |
| Data Storage | Internal eMMC (16 GB) + USB flash drive support (FAT32/exFAT) |
| Dimensions (W×D×H) | 430 × 350 × 190 mm |
| Net Weight | 5.1 kg |
| Light Source | Precision imported quad-wavelength cold LED source (450 nm, 520 nm, 590 nm, 630 nm) |
| Processor | Rockchip RK3288 (ARM Cortex-A17 quad-core, 1.8 GHz) |
| Brand | Shanda |
|---|---|
| Model | SD-PE-T |
| Type | Electronic Farinograph |
| Power Supply | 220 V AC, 50 Hz |
| Motor Power | 300 W |
| Rotational Speed Range | 2–200 ±1 rpm (adjustable, real-time display) |
| Speed Ratio (Fast/Slow Blades) | 1.5:1 |
| Torque Measurement Range | 0–20 N·m |
| Torque Sensor Accuracy | ≤0.3% FS |
| Bowl Capacity | 300 g |
| Torque Unit Calibration | (9.8 ± 0.2) mN·m per Farinograph Unit (FU) |
| Measuring Range | 0–2000 FU |
| Water Addition Accuracy | ±0.2 mL (for 300 g dough) |
| Water Bath Pressure | ≤340 mbar |
| Water Circulation Flow Rate | 15 L/min (auto-fill enabled) |
| Dough Temperature Control | 30 ± 0.2 °C (PID-controlled water jacket) |
| Temperature Setting Range (Incubation Chamber) | 20–50 °C |
| Chamber Temperature Stability | ±0.2 °C |
| Chamber Power | 1200 W |
| Chamber Display | 5-inch embedded LCD touch screen |
| Safety Features | Overload protection (bowl), mechanical/electrical interlock (mixer), real-time heating element monitoring, automatic alarm on anomaly |
| Material | Imported stainless steel (bowl & blades), corrosion-resistant surface-treated structural components |
| Compliance Standards | ICC 115/1, AACC 54-21, ISO 5530-1, GB/T 14614 |
| Data Handling | Multi-file curve overlay (unlimited), custom color/name assignment, cross-brand farinogram import (legacy formats), real-time interruption & interim calculation, encrypted storage, export to CSV/Excel, GLP-compliant audit trail (via Smart Pbox integration) |
| Software | Windows 7/10 native, perpetual license, free lifetime updates |
| Service | Annual certified standard-sample calibration (with CNAS-accredited reference material certificate), two free post-warranty calibration & maintenance visits (Years 2–3), third-party performance evaluation report issued by national metrology institute |
| Connectivity | Real-time multi-terminal data viewing (requires Smart Pbox gateway) |
| Brand | Shanda |
|---|---|
| Model | SD-RXS |
| Origin | Shandong, China |
| Measurement Principle | Compression-based Gravimetric Method (NY/T 821–2004) |
| Force Range | 0–3000 N |
| Resolution | 0.1 N |
| Accuracy | ±1% FS |
| Compression Speed | 1–300 mm/min |
| Dwell Time | 1–3600 s |
| Deformation Range | 1–70 mm |
| Platen Diameter | 110 mm |
| Parallelism | <0.05 mm |
| Dimensions | 450 × 450 × 680 mm |
| Weight | ~45 kg |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Shanda |
|---|---|
| Model | SD-Z08P |
| Origin | Shandong, China |
| Regulatory Approval | Approved by Ministry of Agriculture and Rural Affairs (MARA), P.R. China |
| Detection Principle | Real-Time Fluorescent Quantitative Polymerase Chain Reaction (qPCR) |
| Target Analyte | African Swine Fever Virus (ASFV) Genomic DNA |
| Compatible Assays | MARA-registered ASFV fluorescent qPCR kits (e.g., SD-ASF-KIT series) |
| Operational Modes | Laboratory-based and field-deployable (battery-supported operation optional) |
| Throughput | 8 samples per run |
| Thermal Cycling Range | 4–105 °C |
| Fluorescence Channels | 4-channel excitation/emission detection (FAM, HEX/VIC, ROX, CY5) |
| Data Output | Ct values, amplification curves, qualitative/quantitative reports compliant with MARA diagnostic guidelines |