Empowering Scientific Discovery

Julabo Technology (Beijing) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelTH-ICH-300
Chamber Volume300 L
Temperature Range–5 to +85 °C (with humidity), 0 to +85 °C (without humidity, lamp off), 15 to +85 °C (with humidity & lamp on)
Humidity Range20–85 %RH
Temp. Uniformity±0.3 °C at 40 °C / 60 %RH
Humidity Uniformity±3 %RH at 40 °C / 60 %RH
Lighting Option (ICH Q1B)Cold White Light (6,000 lux), UVA Radiation (4.5 W/m²), Illuminance Uniformity: VIS ±10%, UVA ±15%
Refrigeration SystemAir-cooled single-stage compressor with R-404A
Power SupplyAC 230 V, 1 ph, 50/60 Hz
Current Rating14.7 A (50 Hz) / 15.4 A (60 Hz)
ComplianceDIN 12880, IEC 60068, ICH Q1A(R2), ICH Q1B
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJULABO-ChemTron
OriginGermany
ModelKRC180
Temperature Range−2 °C to +12 °C
Temperature Stability±1 °C
Display Resolution0.1 °C
Internal Volume180 L (Single-Zone)
Internal Dimensions (W×L×H)52 cm × 40 cm × 70 cm
External Dimensions (W×L×H)55 cm × 64 cm × 136 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJULABO
OriginGermany
ModelSC-C-1912D4 / SC-C-0812D2
ConstructionHeavy-Duty Steel Frame with Phenolic Resin-Coated Exterior & Epoxy Powder-Coated Interior
Internal Volume852 L (SC-C-1912D4) / 312 L (SC-C-0812D2)
Shelf Load Capacity≤80 kg per shelf
Spill ContainmentIntegrated 30 mm raised lip +标配 PP spill trays
ComplianceDesigned for ISO 15195, EN 14470-1, and OSHA 29 CFR 1910.1200 (HCS) requirements
Ventilation InterfaceTop-mounted and rear exhaust ports compatible with lab ducted ventilation systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelTH3-KE-025
Temperature Range−40 to 150 °C
Humidity Range20–95 %RH
Internal Volume25 L
Temperature Uniformity (at 50 °C)±0.3 °C
Humidity Uniformity±1 %RH
Heating Time (0 → 90 °C)60 min
Cooling Time (90 → 0 °C)70 min
Power SupplyAC 230 V, 1-phase, 50/60 Hz, 9.7 A
ComplianceDIN 12880, IEC 60068
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChemTron
OriginGermany
ModelTC3-KE-025, TC3-ME-025
Temperature Range−40 °C to +150 °C (TC3-KE), −20 °C to +150 °C (TC3-ME)
Chamber Volume25 L
Temperature Uniformity (at 50 °C)±0.3 °C
Temperature Stability (at 50 °C)±0.5 °C
Heating Time (0 °C → 90 °C)60 min (TC3-KE), 50 min (TC3-ME)
Cooling Time (90 °C → 0 °C)70 min (TC3-KE), 50 min (TC3-ME)
Programmable Logic100 programs × 100 segments × 999 repeats
Control Interface5.6″ color touchscreen
ComplianceDIN 12880, IEC 60068-3-5, FDA-registered device
CommunicationRS-232 standard, RS-485 optional (up to 32 units daisy-chained)