- All
- Favorite
- Popular
- Most rated
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | TL 7800 |
| Instrument Type | Universal Automatic Potentiometric Titrator |
| Measurement Ranges | −3.0–18.00 pH, −2000 to +2000 mV, 0–100 mA, −75 to +195 °C |
| Meter Accuracy | ±0.001 pH, ±0.1 mV, ±0.1 µA, ±0.1 °C |
| Meter Resolution | 0.001 pH, 0.1 mV, 0.1 µA, 0.1 °C |
| Titration Accuracy | ±0.002 digit (pH), ±0.10 digit (mV), ±0.2 digit (µA), ±0.2 K digit (°C) |
| Titration Resolution | 0.001 pH, 0.1 mV, 0.1 µA, 0.1 °C |
| Display | 3.5″ 1/4-VGA TFT color touchscreen |
| Burette Options | 5 / 10 / 20 / 50 mL |
| Electrode Interfaces | DIN 19262 or BNC (pH/mV), dual Pt-wire (dead-stop), IDS digital interface (pH, ORP, conductivity), Pt1000/NTC30 temperature input |
| Data Export | USB-A (PDF, CSV), RS-232 (balance), optional continuous sample handler (TW module) |
| Software Compatibility | TitriSoft 3.0 |
| Wireless Electrode Recognition | SI Analytics ID & IDS electrode auto-detection |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | TL 5000 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Display | 3.5" 1/4VGA TFT touchscreen |
| pH Range | -3.0 to 17.00 |
| mV Range | -1900 to +1900 mV |
| Temperature Range | -30 to +115 °C |
| pH Resolution | 0.01 |
| mV Resolution | 1 mV |
| Temp Resolution | 0.1 °C |
| pH Accuracy | ±0.05 ±1 digit |
| mV Accuracy | ±1.0 ±1 digit |
| Temp Accuracy | ±0.5 K ±1 digit |
| Burette Options | 20 mL or 50 mL |
| Burette Drive | 8000-step precision piston |
| Electrode Interfaces | DIN 19262 and BNC |
| Temperature Sensor Support | Pt1000 and NTC 30 |
| Titration Modes | DET (Dynamic Equivalence Point), MET (Fixed Increment), SET (Set Endpoint), pH/mV Endpoint, Manual Dosing, Precise Dispensing |
| Preloaded Methods | FOS/TAC, Total Alkalinity, Total Acidity, Chloride, COD, Permanganate Index, Kjeldahl Nitrogen, Iodometry, Peroxide Value, Ascorbic Acid, Protein (via Kjeldahl), Ammonia-N |
| Connectivity | RS-232 for balance, USB-A for printer |
| Compliance | Designed for GLP-compliant workflows per ISO/IEC 17025 and ASTM E2029 guidelines |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | TL 7500 KF trace |
| Measurement Range | 1 ppm – 5% water |
| Titration Accuracy | <0.3% (at 1 mg water) |
| Display | 3.5″ 1/4VGA TFT touchscreen |
| Electrode Options | Membrane and membrane-free generator electrodes |
| Interface Ports | 2×RS232, 2×USB-A, 2×USB-B |
| Supported Methods | 50 pre-programmed coulometric KF methods |
| Software | TitriSoft 3.3 |
| Compliance | GLP-compliant reporting, ASTM E203, ISO 8536-5, USP <921>, EP 2.5.12 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | CAT2-16 |
| Instrument Type | General-purpose Potentiometric Titrator |
| pH Range | 0–14 |
| pH Accuracy | ±0.02 |
| pH Resolution | ±0.01 |
| Titration Accuracy | ±0.02 pH |
| Titration Resolution | ±0.01 pH |
| Display | 4.3″ Touchscreen |
| Burette Capacity | 10 mL (up to two mounted) |
| Burette Resolution | 12,000 steps |
| Burette Accuracy | <0.2% (2 µL for 10 mL) |
| Burette Repeatability | ±0.2% |
| Peristaltic Pump Flow Rate | 1 mL/s (up to three units) |
| mV Range | ±2000 mV, Accuracy: ±2 mV, Resolution: ±0.1 mV |
| Current Range | ±10 µA, Accuracy: ±2 µA, Resolution: ±0.1 µA |
| Temperature Range | 0–100 °C, Accuracy: ±1 °C, Resolution: ±0.1 °C |
| Pre-programmed Methods | 30 (incl. EP, EQ, Free SO₂, Total SO₂, Double SO₂) |
| Calibration Modes | Auto-buffer recognition, zero-point, zero-slope, Nernst equation, wine-specific calibration |
| Data Storage | 50 titration reports, 10 calibration records |
| Interfaces | pH/mV electrode port, µA electrode port, USB-A, USB-B, RS232, Bluetooth |
| Brand | JULABO-Chemtron |
|---|---|
| Origin | Italy |
| Model | CAT2-35 Series |
| Titration Types | Endpoint, Equivalence Point, Linear, Dynamic, Continuous pH Monitoring |
| pH Range | 0–14 |
| mV Range | ±2000 mV |
| Current Range | ±10 µA |
| Temperature Range | 0–100 °C |
| pH Accuracy | ±0.02 |
| pH Resolution | ±0.01 |
| mV Accuracy | ±2 mV |
| mV Resolution | ±0.1 mV |
| Current Accuracy | ±2 µA |
| Current Resolution | ±0.1 µA |
| Temperature Accuracy | ±1 °C |
| Temperature Resolution | ±0.1 °C |
| Burette Capacity | 10 mL (dual mountable) |
| Burette Precision | <0.2% (2 µL @ 10 mL) |
| Burette Repeatability | ±0.2% |
| Pump Flow Rate | 1 mL/s (up to 3 peristaltic pumps) |
| Display | 4.3″ capacitive touchscreen |
| Method Storage | 30 preloaded templates (EP, EQ, Free/Total SO₂, Double SO₂) |
| Data Storage | 50 titration reports + 10 calibration records |
| Interfaces | pH/mV/µA electrode ports, USB-A, USB-B, RS232, Bluetooth |
| Brand | JULABO-Chemtron |
|---|---|
| Origin | Italy |
| Model | CAT2-1 Series |
| Instrument Type | General-Purpose Potentiometric Titrator |
| pH Range | 0–14 |
| mV Range | ±2000 mV |
| Current Range | ±10 µA |
| pH Accuracy | ±0.02 pH |
| pH Resolution | ±0.01 pH |
| mV Accuracy | ±2 mV |
| mV Resolution | ±0.1 mV |
| Current Accuracy | ±2 µA |
| Current Resolution | ±0.1 µA |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±1 °C |
| Temperature Resolution | ±0.1 °C |
| Burette Capacity | 10 mL (dual mountable) |
| Burette Precision | <0.2% (2 µL @ 10 mL) |
| Burette Repeatability | ±0.2% |
| Burette Resolution | 12,000 steps |
| Peristaltic Pump Flow Rate | 1 mL/s (up to 3 modules) |
| Method Storage | 30 preloaded templates (EP, EQ, Free SO₂, Total SO₂, Double SO₂) |
| Data Storage | 50 titration reports + 10 calibration records |
| Interfaces | pH/mV/µA electrode ports, USB-A, USB-B, RS232, Bluetooth |
| Display | 4.3″ capacitive touchscreen |
| Brand | ChemTron |
|---|---|
| Origin | Italy |
| Model | CAT1-1 Series |
| Instrument Type | General-Purpose Potentiometric Titrator |
| pH Range | 0–14 |
| mV Range | ±2000 mV |
| Current Range | ±10 µA |
| pH Accuracy | ±0.02 pH |
| mV Accuracy | ±2 mV |
| Current Accuracy | ±2 µA |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±1 °C |
| Titration Tube Capacity | 10 mL (dual-mountable) |
| Titration Resolution | 12,000 steps |
| Titration Accuracy | <0.2% (2 µL for 10 mL tube) |
| Titration Repeatability | ±0.2% |
| Pump Flow Rate | 1 mL/s (up to 3 peristaltic pumps) |
| Display | 4.3″ capacitive touchscreen |
| Built-in Methods | 30 (including EP, EQ, Free SO₂, Total SO₂, Double SO₂) |
| Data Storage | 50 titration results + 10 calibration records |
| Interface | pH/mV/µA electrode ports, USB-A, USB-B, RS232, Bluetooth |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | TL 7500 KF |
| Measurement Range | 1 ppm – 5% H₂O |
| Electrode Resolution | <0.3% (1 mg water) |
| Display | 3.5″ 1/4 VGA TFT touchscreen |
| Titration Volumes | 5 / 10 / 20 / 50 mL burettes |
| Current Detection Range | 0–100 µA |
| Current Resolution | 0.1 µA |
| Current Accuracy | ±0.2 µA ±1 digit |
| Electrode Interface | Dual platinum pin (2×4 mm) |
| Connectivity | RS-232 (balance), USB-A (printer), optional TW auto-sampler and TitriSoft 3.3 software |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | TL 7750 |
| Instrument Type | Universal Automatic Potentiometric Titrator |
| Application Scope | General-purpose titration and volumetric Karl Fischer water determination |
| Measurement Range | −3.0 to 18.00 pH, −2000 to +2000 mV, 0–100 µA, −75 to +150 °C (with Pt1000 sensor) |
| Meter Accuracy | ±0.002 pH (±1 digit), ±0.1 mV (±1 digit), ±0.2 µA (±1 digit), ±0.2 K (±1 digit) |
| Meter Resolution | 0.001 pH, 0.1 mV, 0.1 µA, 0.1 °C |
| Titration Resolution | 0.001 pH, 0.1 mV, 0.1 µA, 0.1 °C |
| Titration Accuracy | ±0.002 pH (±1 digit), ±0.2 µA (±1 digit), ±0.2 K (±1 digit) |
| Display | 3.5″ 1/4 VGA TFT color touchscreen |
| Predefined Methods | 50 built-in titration methods |
| Electrode Interfaces | DIN 19262 or BNC (pH/mV), dual-platinum stop-endpoint (2×4 mm), Pt1000 temperature input |
| Compatible Burettes | 5, 10, 20, and 50 mL |
| Communication Ports | USB-A (printer, flash drive, keyboard), RS-232 (balance), optional TW continuous sample module |
| Software Compatibility | TitriSoft 3.0 |
| Data Export Formats | PDF, CSV |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | TW alpha plus |
| Instrument Type | Universal Potentiometric Titrator |
| Sample Capacity | 12/16/24-position carousel (24-position compatible with COD reaction vials) |
| Cleaning System | Automated single- or dual-solvent rinse between titrations |
| Stirring Options | Bottom-mounted magnetic stirring or top-mounted mechanical stirring |
| Optional Peristaltic Pump | MP25 membrane liquid pump for complex titration protocols |
| Control Interface | Fully operable via integrated titrator console or external PC-based software |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Connectivity | Compatible with analytical balances, thermostatted titration vessels, Karl Fischer dry ovens, homogenizers, printers, and PCs |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | TL 7000 |
| Titration Types | General-purpose potentiometric titration |
| pH Range | 3.0–18.0 |
| mV Range | −2000 to +2000 mV |
| Temperature Range | −75 to +175 °C |
| pH Resolution | 0.001 pH |
| mV Resolution | 0.1 mV |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.002 ±1 digit |
| mV Accuracy | ±0.10 ±1 digit |
| Current (µA) Accuracy | ±0.2 ±1 digit |
| Temperature Accuracy | ±0.2 K ±1 digit |
| Display | 3.5″ 1/4-VGA TFT color touchscreen |
| Method Storage | 50 pre-programmed or user-defined methods |
| Electrode Interfaces | DIN 19262 / BNC (pH/mV), dual 2×4 mm Pt electrodes (dead-stop), PT1000 temperature input |
| Compatible Software | TitriSoft 3.3 |
| GLP Compliance | Full audit trail, electronic signature support, method & result traceability |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | TW alpha plus |
| Instrument Type | Universal Potentiometric Titrator |
| Sample Capacity | 24 × 50 mL beakers |
| Cleaning | Automated single- or dual-solvent rinse between titrations |
| Stirring Options | Bottom magnetic stirring or top mechanical stirring |
| Optional Accessories | MP25 diaphragm liquid pump |
| Compatibility | TitroLine alpha plus titrators, Titrosoft 3.0 / 3.0P software, TITRONIC dispensers, analytical balances, thermostatted titration vessels, dryers, homogenizers |
| Brand | JULABO-Chemtron |
|---|---|
| Origin | Italy |
| Model | CAT1-16 Series |
| Instrument Type | General-purpose Automatic Potentiometric Titrator |
| pH Range | 0–14 |
| mV Range | ±2000 mV |
| Current Range | ±10 µA |
| Temperature Range | 0–100 °C |
| pH Accuracy | ±0.02 pH |
| pH Resolution | ±0.01 pH |
| mV Accuracy | ±2 mV |
| mV Resolution | ±0.1 mV |
| Current Accuracy | ±2 µA |
| Current Resolution | ±0.1 µA |
| Temperature Accuracy | ±1 °C |
| Temperature Resolution | ±0.1 °C |
| Burette Volume | 10 mL (dual configurable) |
| Burette Precision | <0.2% (2 µL @ 10 mL) |
| Burette Repeatability | ±0.2% |
| Pump Flow Rate | 1 mL/s |
| Display | 4.3″ capacitive touchscreen |
| Method Storage | 30 preloaded templates (EP, EQ, Free SO₂, Total SO₂, Double SO₂) |
| Data Storage | 50 titration reports + 10 calibration records |
| Interface | pH/mV/µA electrode ports, USB-A, USB-B, RS232, Bluetooth |
Show next