- All
- Favorite
- Popular
- Most rated
| Brand | INFORS |
|---|---|
| Origin | Switzerland |
| Model | Techfors Cell |
| Working Volume Range | 5–500 L (customizable up to 1,000+ L) |
| Control System | Safe-DDC Process Controller |
| Stirring Options | Top- or Bottom-Driven Impeller Configuration |
| Shaft Sealing | Single- or Dual-Mechanical Seal |
| CIP/SIP | Integrated In-Place Cleaning and Sterilization |
| Footprint | Space-Optimized Modular Design |
| Compliance | Designed for GMP/GLP-aligned bioprocess development and scale-up |
| Brand | INFORS |
|---|---|
| Origin | Switzerland |
| Model | Multifors 2 |
| Dimensions (W × D × H) | 350 × 520 × 960 mm (for 2-vessel configuration) |
| Temperature Range | Cooling liquid temperature +5 °C to 70 °C |
| Agitation | Magnetically driven, 100–1600 rpm |
| Aeration | Open-loop gas supply, up to 4 rotameters or mass flow controllers (MFCs), max. 2 vvm |
| pH Sensors | Optional Mettler Toledo analog electrode (2–12 pH) or Hamilton digital electrode (0–14 pH) |
| Dissolved Oxygen (pO₂) Sensors | Optional Mettler Toledo analog electrode (0–150 % air saturation) or Hamilton digital electrode (0.05–300 % air saturation) |
| Peristaltic Pumps | 3 digital pumps + 1 analog pump (adjustable speed) |
| Sterilization | Integrated off-line autoclavable design |
| Data Communication | OPC XML DA via Ethernet |
| Expandable Parameters | Up to 24 process variables including balance, redox, pCO₂, conductivity, optical density (Optek), and off-gas analysis |
| Software Platform | EVE Process Control Software |
| Brand | INFORS |
|---|---|
| Origin | Switzerland |
| Model | Labfors 5 |
| Vessel Volume | 1–10 L |
| Aeration System | Central flow control |
| pH Control Range | 1–14, Accuracy: ±0.01 |
| Dissolved Oxygen (DO) Control Range | 0–200 %, Accuracy: ±0.1 % |
| Temperature Control Range (jacketed mode) | Cooling medium temperature +5 °C to 70 °C, Accuracy: ±0.1 °C |
| Brand | INFORS |
|---|---|
| Origin | Switzerland |
| Model | Techfors-S |
| Volume Range | 5–20 L (standard configurations) |
| Sterilization | In-situ steam sterilization (SIP) |
| Control System | IRIS v4.0 with real-time monitoring & cascade control |
| Gas Control | 4+1 gas mixing station (Air/O₂/N₂/CO₂ + Air backup) with optional thermal mass flow controllers (MFCs) |
| Agitation | Top-driven mechanical stirring with adjustable speed (0–600 rpm) |
| Temperature Control | Jacketed vessel with independent steam/water pathways |
| Sampling | Bottom-centered sterile sampling valve with dedicated SIP line |
| Pumping | Up to 5 programmable digital peristaltic pumps (4 standard, 1 optional) |
| Filtration | 0.2 µm hydrophobic membrane filters (side-mounted inlet/outlet) |
| Data Interface | RS-232, Ethernet (optional), FDA 21 CFR Part 11 compliant audit trail (IRIS software) |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | INFORS |
|---|---|
| Origin | Switzerland |
| Model | Labfors BioEtOH |
| Vessel Total Volume | 3.6 L |
| Working Volume Range | 1.0–2.3 L |
| Temperature Control Range | +5 °C to 60 °C (±0.1 °C accuracy) |
| pH Control Range | 2.00–12.00 (±0.01 accuracy, Mettler Toledo sterilizable electrode) |
| Dissolved Oxygen (pO₂) Control Range | 0–100 % (±0.1 % accuracy, Mettler Toledo sterilizable electrode) |
| Agitation Speed | 0–200 rpm (±1 rpm resolution) |
| In-Situ Probe Integration | Temperature, pH, pO₂, Foam, Optional: Off-Gas CO₂/O₂, Turbidity, Mass, Pressure, Methanol |
| Brand | INFORS |
|---|---|
| Origin | Switzerland |
| Model | Minifors 2 |
| Vessel Options | 5 L / 3.5 L working volume or 2.5 L / 1.2 L working volume |
| Temperature Control Range | +5 °C to 60 °C (cooling medium dependent) |
| Agitation | 100–1250 rpm, ±1 rpm accuracy |
| pH Range | 1.0–14.0, ±0.1 pH |
| Dissolved Oxygen (pO₂) | 0–100 %, ±0.1 % |
| Sterilization | Integrated off-line autoclavable design |
| Peristaltic Pumps | 2 standard (expandable to 4), max. 3.7 mL/min each, 0–100 % controllable |
| Foaming Control | Intelligent capacitive foam electrode with automatic detection |
| Gas Control | Central air flow regulation |
| Sensor Compatibility | Sterilizable pH and pO₂ electrodes, integrated level and temperature sensors |
| Brand | INFORS |
|---|---|
| Origin | Switzerland |
| Model | Labfors Lux Cell |
| Vessel Volume | 3.6 L (cylindrical) / 1.9 L (flat-panel) |
| Aeration System | Single-gas (air) or multi-gas mixing station (Air + O₂ + N₂ + CO₂ + headspace air) |
| pH Control Range | 0.00–14.00, Accuracy: ±0.01 |
| Dissolved Oxygen (DO) Control Range | 0–100%, Accuracy: ±1% |
| Temperature Control Range | Cooling-medium temperature +5 °C to 70 °C, Accuracy: ±0.1 °C |
| Illumination | Adjustable white-light LED array (16 high-efficiency LEDs, up to ~700 µmol/m²·s) |
| Agitation | Bacterial mode: 80–1200 rpm |
| Mammalian/cell mode | 30–300 rpm |
| Standard Parameters | Temperature, pH, DO, agitation, gas flow, antifoam/level, feeding, gas composition |
Show next