Life Science Instruments
Filter
Showing 5731–5760 of 7334 results
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HTY-EMD02 / HTY-EMD02W |
| Power Supply | Rechargeable Li-ion Battery |
| Charging Time | 3 h |
| Sensing Distance | 0–150 mm (adjustable) |
| Operating Modes | Infrared Proximity Sensing / Manual Button Activation |
| Continuous Runtime | 35 h |
| Membrane Output Capacity | Up to 40,000 membranes per full charge |
| Housing Material | ABS Plastic |
| Drive Roller Material | 316L Stainless Steel |
| Drive Motor | Rare-earth Permanent Magnet DC Motor with High Positioning Accuracy and Extended Service Life |
| Compliance | Designed for ISO 13485-certified cleanroom environments and compatible with sterile membrane packaging formats (e.g., double-bagged, gamma-irradiated, individually wrapped) |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HTY-MFS03 |
| Price Range | USD 1,400 – 7,200 |
| Input Voltage | AC 220 V / 50 Hz |
| Power Consumption | 500 W |
| Dispensing Volume Range | 1–1000 mL |
| Compatible Petri Dish Diameter | 90 mm |
| Dispensing Accuracy | ±1% at 20 mL |
| Throughput | 1200 dishes/h (at 20 mL/dish) |
| Dimensions (W×D×H) | 740 × 550 × 430 mm |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Region Category | Domestic (China) |
| Model | NPA Series |
| Price Range | USD 28,000 – 70,000 |
| Power Supply | 380 V / 50 Hz |
| Chamber Material | SUS316L Stainless Steel |
| Negative Pressure Maintenance Power | 1000 W |
| Airflow Pattern | Turbulent Flow |
| Operating Chamber Pressure | −80 Pa to −50 Pa |
| Containment Performance | Designed to OEB5 Standard |
| Noise Level (Negative Pressure Mode) | <65 dB(A) |
| Chamber Integrity | Compliant with ISO 10648-2 |
| Brand | Tailin |
|---|---|
| Model | SCW-160 |
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Category | Domestic Instrument |
| Computing Platform | Intel Core i7 / 16 GB RAM / 4 TB HDD / Windows 10 |
| Imaging System | 20 MP CMOS camera with fixed-focus lens |
| Illumination | LED annular shadow-free light (6500–7500 K) |
| Temperature Control | Refrigerant-free heating/cooling system |
| Display | 15″ 1080p capacitive touchscreen |
| Internal Chamber Dimensions | 630 × 660 × 440 mm |
| Overall Dimensions | 950 × 750 × 1700 mm |
| Weight | 200 kg |
| Construction Materials | Powder-coated exterior, aluminum alloy interior chamber, 304 stainless steel frame, tempered glass viewport |
| Acoustic Noise Level | ≤55 dB(A) |
| Power Input | 220 V, 50 Hz (16 A), Max. 2200 W |
| Software Features | Three-tier user permissions, electronic signature, audit trail, remote firmware/algorithm updates, PDF/PNG export, manual correction logging, time-lapse image playback & zoom, colony growth curve generation |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fully Automated Colony Counter & Incubation Workstation |
| Maximum Sample Capacity | 320 Petri Dishes |
| Compliance | Designed for ISO 4833-1:2013, ISO 7218, USP <61>, EU Pharmacopoeia 2.6.12, and FDA Bacteriological Analytical Manual (BAM) workflows |
| Connectivity | Ethernet, USB, Wi-Fi |
| Data Export Formats | PDF, XLSX, CSV, TIFF, JPEG |
| Imaging System | High-resolution monochrome CMOS sensor (5 MP), motorized focus, uniform LED illumination with glare-free coaxial lighting |
| Algorithm Engine | Proprietary deep neural network trained on >10,000 annotated colony images across 12 microbial species and 7 substrate types |
| Growth Monitoring | Time-lapse imaging at user-defined intervals (1–24 h) |
| Environmental Control | Integrated incubation chamber (range: 20–45 °C, ±0.3 °C stability), humidity monitoring (optional sensor) |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Custom Configurable |
| Pricing | Upon Request |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model Series | BR |
| Instrument Type | Air-Jacketed Constant-Temperature Shaker |
| Timer Range | Programmable (varies by model) |
| Oscillation Frequency | 20–500 rpm |
| Oscillation Amplitude | 1–75 mm |
| Temperature Range | +4 °C to +100 °C (model-dependent) |
| Platform Configuration | Single or Multi-Deck Platforms |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | BR Series |
| Temperature Range | +4 °C to +100 °C |
| Oscillation Modes | Orbital, Reciprocating, or Switchable |
| Speed Range | 20–500 rpm |
| Amplitude | 10–50 mm |
| Timer Range | 0–99 h 59 min |
| Platform Capacity | Up to 64 × 500 mL flasks |
| Compliance | Designed for GLP-compliant labs, compatible with ISO 17025 workflows and USP <1058> analytical instrument qualification protocols |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | BR-180LF / BR-180LF-Light / BR-180LF-70RT |
| Oscillation Mode | Orbital & Reciprocal (switchable) |
| Speed Range | 25–400 rpm |
| Amplitude | 25 mm / 50 mm (BR-180LF), 70 mm (BR-180LF-70RT) |
| Temperature Range | +4°C to +70°C (standard & 70RT), +15°C to +70°C (Light model) |
| Temp. Accuracy | ±0.3°C to ±1.0°C |
| Platform Size | 700 × 500 mm |
| Max. Load Capacity | 10 kg (excl. platform) |
| Illumination | Up to 11,000 lux (adjustable, 6 × 20 W daylight lamps) |
| Door Design | Dual-hinged clamshell (top + front access) |
| Cooling | Compressor-based (125 W) |
| Heating | 700 W resistive heater |
| Power Supply | AC 100 V, 12 A (50/60 Hz) |
| Dimensions (W×D×H) | 1110 × 716 × 990 mm (BR-180LF), 1110 × 716 × 1075 mm (Light), 1110 × 716 × 930 mm (70RT) |
| Weight | ~180 kg (BR-180LF), ~205 kg (Light), ~190 kg (70RT) |
| Compliance | Designed for GLP-compliant microbial, cell, and photobiological cultivation |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model Series | BR-21/22/23 (FP/UM/FH variants) |
| Temperature Range | +15 °C to +35 °C (standard operating range) |
| Temperature Uniformity | ±0.2 °C |
| Cooling Method | Peltier (4 × 70 W modules) |
| Heating Method | Resistive (350 W for FH models) |
| Oscillation Mode | Reciprocating or Orbital |
| Speed Range | 20–300 rpm (≤200 rpm when stacked) |
| Amplitude | 25 mm |
| Platform Dimensions | 290 × 250 mm |
| Internal Height | 270–315 mm (model-dependent) |
| Load Capacity | ~3.5 kg (including platform and fixtures) |
| Display & Control | Digital, 9-segment programmable protocol (temperature, speed, time), gradient function |
| Safety Features | Over-temperature/over-current protection, door-open detection, sensor diagnostics, motor current limiting, built-in fuse |
| Power Supply | AC 100 V, 5 A |
| Dimensions (W×D×H) | 422–437 × 550–585 × 540–545 mm |
| Weight | 41.5–49.5 kg |
| Stackable | Yes (up to 2 units with STB-4842 base) |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | BR-22FP·MR |
| Instrument Type | Air-Jacketed Temperature-Controlled Orbital Shaker |
| Timer Range | 0–99 h 59 min |
| Oscillation Speed | 20–300 rpm |
| Amplitude | 25 mm |
| Temperature Range | +15°C to +60°C |
| Capacity | 6 × 500 mL Erlenmeyer flasks |
| Cooling Method | Peltier (4 × 70 W) |
| Heating Method | Peltier |
| Temperature Control Accuracy | ±0.2°C |
| Oscillation Mode | Orbital |
| Chamber Dimensions (W×D×H) | 290 × 250 × 270 mm (internal height) |
| Max Load | ~3.5 kg (including platform and fixtures) |
| Power Supply | AC 100 V, 5 A |
| Net Weight | ~49 kg |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | BR-300 / BR-300LF |
| Oscillation Mode | Reciprocating or Orbital (Switchable) |
| Speed Range | 25–160 rpm |
| Amplitude | 10–50 mm (adjustable) |
| Temperature Range | +10°C to +70°C (BR-300), +4°C to +70°C (BR-300LF) |
| Platform Dimensions | 600 × 400 mm |
| Internal Height | 575 mm |
| Load Capacity | ~10 kg per shelf (excl. platform) |
| Display | Digital (dual-mode: set temp / chamber temp) |
| Heating | 700 W heater |
| Cooling | Circulating chiller (BR-300) or built-in compressor (125 W, BR-300LF) |
| Timer Function | Cumulative oscillation time (0.1–999.9 h, auto-reset) |
| Safety Features | Leakage/overcurrent breaker, high-temp cutoff (compressor circuit), sensor fault diagnostics, deviation alarm (upper/lower limits) |
| Compliance | Designed for GLP-compliant labs |
| Power Supply | AC 100 V, 8 A (BR-300), 11 A (BR-300LF) |
| Net Weight | 210 kg (BR-300), 220 kg (BR-300LF) |
| Dimensions (W×D×H) | 1110 × 682 × 1120 mm |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | BR-300 / BR-300LF / LED-Illuminated BR-300LF |
| Temperature Range | +4°C to +70°C |
| Oscillation Mode | Switchable Orbital/Reciprocating |
| Speed | 25–250 rpm |
| Amplitude | 10–50 mm (continuously adjustable) |
| Timer Range | 00h00m to 99h59m |
| Illumination | Up to 8000 lx (LED, dimmable, 24-h timer with 15-min ON/OFF steps) |
| Platform Dimensions | 600 × 400 mm |
| Max Load Capacity | 10 kg (platform excluded) |
| Heating Power | 700 W |
| Cooling | Compressor (125 W, BR-300LF & LED models) or Water-Cooled (BR-300) |
| Temp. Control Accuracy | ±0.3°C to ±1.0°C |
| Safety Features | Leakage/overcurrent protection, compressor overheat cutoff, temperature deviation alarm, sensor self-diagnosis, auto-reset cumulative oscillation timer (0.1–999.9 h) |
| Power Supply | AC 100 V, 8–12 A |
| Net Weight | 200–230 kg |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | BR-3000LF (Single-Tier) / Dual-Tier BR-3000LF |
| Temperature Range | +4 °C to +70 °C |
| Temperature Control Accuracy | ±0.3 °C to ±1.0 °C |
| Oscillation Mode | Switchable Orbital or Reciprocating |
| Speed Range | 25–250 rpm (Single-Tier), 25–160 rpm (Dual-Tier) |
| Amplitude | Adjustable 10–50 mm |
| Timer Range | 0.1–999.9 h |
| Platform Dimensions | 800 × 600 mm |
| Internal Chamber Height | 605 mm |
| Load Capacity | ~17 kg per tier (excluding platform) |
| Power Supply | AC 100 V, 12 A |
| Total Weight | ~310 kg (Single-Tier), ~330 kg (Dual-Tier) |
| Heating | 800 W Heater |
| Cooling | 125 W Compressor |
| Safety Features | Leakage/overcurrent breaker, compressor overheat cutoff, temperature deviation alarm, sensor self-diagnosis, sample protection circuit |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | BR-40LF, BR-41FL/MR, BR-42FL/MR, BR-43FM/MR, BR-43FH/MR |
| Shaker Type | Air-Jacketed Temperature-Controlled Orbital Shaker |
| Timer Range | 00h00min to 99h59min |
| Oscillation Speed | 20–300 rpm |
| Orbit Diameter | 25 mm |
| Temperature Range | Ambient +5°C to +70°C (standard) |
| Platform Configuration | Single or Dual Shaking Platforms |
| Compliance | Designed for GLP-compliant microbiological and cell culture workflows per ISO 13485-aligned manufacturing standards |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | BR-RAMOS |
| Instrument Type | Automated Microbial Respiration Kinetics Monitoring System |
| Throughput | 8 × 250 mL Erlenmeyer Flasks |
| Detection Limit | >0.0002 mol/h/L |
| Measurement Accuracy | <4% deviation |
| Temperature Range | +15°C to +50°C |
| Temp. Control Precision (BR-40RAM) | ±0.2°C |
| Agitation Mode | Orbital Shaking |
| Amplitude | 10–40 mm (stepless) |
| Speed | 20–200 rpm |
| Platform Dimensions | 400 × 300 mm |
| Power Supply | AC 100 V |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | C·BR-500S |
| Temperature Range & Accuracy | +20 to +40 °C, ±0.5 °C |
| Temperature Uniformity | ±0.5 °C |
| Capacity | 50 L (max. working volume: 25 L) |
| Rocking Angle | 3–12° |
| Rocking Speed | 3–40 rpm (angle × speed < 240) |
| Gas Control | O₂/CO₂ blending, concentration accuracy ≤ ±1% |
| Gas Flow Rate | 80–500 mL/min |
| Agitation Mode | Rocking (see-saw type) with adjustable tilt |
| Humidity Control | Not specified |
| Sensor Integration | Non-invasive DO and pH monitoring (optional, requires sensor-integrated 2D bioprocess bags) |
| Safety Features | Emergency stop, leakage circuit breaker, overtemperature protection, door interlock, pressure sensor |
| Construction | Stainless steel exterior |
| Dimensions (W×D×H) | 1500 × 720 × 1100 mm (excl. protrusions) |
| Key | Brand: TAITEC |
|---|---|
| Origin | Japan |
| Model | CO2-BR Series |
| Temperature Range | +4°C to +50°C |
| Temp. Control Accuracy | ±0.3°C to ±1.0°C |
| Oscillation Mode | Reciprocating / Orbital Switchable |
| Speed Range | 20–200 rpm (CO2-BR-40LF), 25–250 rpm (CO2-BR-43FL-MR/MT), 25/50 mm (CO2-BR-180LF) |
| Amplitude | 10–40 mm (variable), 25 mm (fixed), 25/50 mm (switchable) |
| Timer Range | 0 min – 99 h 59 min |
| Gas Distribution Channels | Up to 12 branches |
| Compatible Vessels | Erlenmeyer flasks (125 mL–5 L), multiwell plates, culture bags (5–20 L) |
| Power Supply | AC 100 V ±9% / ±12% |
| Weight | 70–180 kg |
| Compliance | Designed for GLP-compliant cell culture workflows |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | CS-LR |
| Timer Range | 0–99 h |
| Oscillation Frequency | 15–200 rpm |
| Amplitude | 25 mm (factory-set, optional 20 mm) |
| Temperature Range | 0–50 °C |
| Platform Size | 300 × 200 mm |
| Load Capacity | ~3 kg |
| Humidity Tolerance | ≤95% RH ±5% |
| Construction | SUS304 Stainless Steel Body & KENIFINE™-Coated Platform |
| Safety | Fuse, Motor Overload Protection, Overvoltage Protection |
| Dimensions (Shaker) | 302 × 240 × 129 mm |
| Weight (Shaker) | ~7 kg |
| Power Supply | AC 100 V, 1 A |
| Control Box Dimensions/Weight | 125 × 30 × 70 mm / ~0.5 kg |
| Standard Accessories | AC adapter, reciprocal/rotary mode bar, 2-m power cable |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | M·BR-034P / M·BR-034 / M·BR-032P / M·BR-032 / M·BR-104P / M·BR-104 |
| Instrument Type | Air-Jacketed Temperature-Controlled Orbital Shaker |
| Oscillation Frequency Range | 200–1600 rpm |
| Orbit Diameter | 2 mm |
| Temperature Range | Ambient −7 °C to 60 °C |
| Shelf Configuration | Dual or Quad Platform (2 or 4 interchangeable shelves) |
| Sample Compatibility | 96-well microplates, deep-well plates (e.g., 96DW), 0.5–5.0 mL microtubes, 15–50 mL centrifuge tubes (with optional platforms) |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | MBR-034P / MBR-034 / MBR-032P / MBR-032 / MBR-104P / MBR-104 |
| Shaker Type | Air-jacketed Temperature-Controlled Orbital Shaker |
| Oscillation Frequency Range | 200–1600 rpm |
| Orbit Diameter | 2 mm |
| Temperature Range | Ambient −7 °C to +60 °C |
| Shelf Capacity | 2 or 4 interchangeable platforms |
| Power Efficiency | Designed for low-energy operation |
| Noise Level | <45 dB(A) at 500 rpm (typical) |
| Compliance | Supports IQ/OQ/PQ documentation per GMP/GLP requirements |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | E-36 |
| Timer Range | 5–60 min |
| Oscillation Speed | 300–1000 rpm (Low Range), 1200–2500 rpm (High Range) |
| Oscillation Mode | Horizontal Eccentric |
| Platform Dimensions | 270 × 102 mm (external) |
| Sample Capacity | 96-well microplates (up to 2 plates), 1.5 mL tubes (36 or 40, with optional holders EM-1036/EM-1040), 0.5 mL tubes (36, with EM-0836) |
| Optional Platforms | WP-9602 deep-well plate platform |
| Power Supply | AC 100–220 V, 0.3 A |
| Weight | ~5 kg |
| Certifications | CE-compliant, designed for ISO 13485-aligned laboratory environments |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | EP-1 |
| Instrument Type | Water Bath Shaker / Reciprocating Incubator Shaker |
| Oscillation Mode | Reciprocating |
| Speed Range | 20–160 rpm |
| Amplitude | 0–30 mm (continuously adjustable) |
| Platform Dimensions | 275 × 315 mm |
| Bath Internal Dimensions | 280 × 395 × 140 mm (W × D × H) |
| External Dimensions / Weight | 330 × 575 × 250 mm / ~14 kg |
| Power Supply | AC 100 V, 1 A |
| Max Operating Temperature | ≤80 °C (≤70 °C with plastic bath) |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | G·BR-200 / G·BR-300 |
| Oscillation Frequency | 25–300 rpm |
| Oscillation Amplitude | Switchable 25 mm / 50 mm |
| Temperature Range | +4°C to +80°C |
| Platform Dimensions | 700 × 500 mm |
| Max. Capacity | 96 × 50 mL Erlenmeyer flasks (on MT-7050 platform) |
| Temperature Control Accuracy | ±0.3°C to ±1.0°C |
| Heating Power | 700 W |
| Compressor Cooling Power | 125 W |
| Power Supply | AC 100 V, 12 A |
| Net Weight | ~235 kg |
| External Dimensions (H×W×D) | 1200 × 800 × 810 mm |
| Safety Features | Over-temperature/over-current protection, compressor overheat cutoff, door-open detection, motor runaway detection, non-volatile memory error monitoring, filter check indicator |
| Programmable Memory | 4 programs × 9 steps |
| Energy Efficiency | ~25% lower power consumption vs. prior-generation units under equivalent thermal load |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | GM-01 |
| Instrument Type | Bead Mill Cell Disruptor |
| Temperature Range | 0 °C to 40 °C |
| Sample Volume | 2.0 mL per tube |
| Throughput | Up to 12 samples (6 with metal beads) |
| Maximum Centrifugal Force | 1300 × g |
| Speed Range | 500–4500 rpm |
| Vortex Mixing Intensity | 10 levels (Level 10 ≈ 2600 rpm equivalent shear) |
| Timer Range | 0–50 sec, or 1 min–99 h 50 min |
| Dimensions | 210 × 268 × 176 mm (W × D × H) |
| Weight | ~3.5 kg |
| Power Supply | AC 100–125 V, 0.5 A |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | HB-80 |
| Temperature Range | Ambient +8°C to 80°C |
| Temperature Uniformity | ±0.1°C |
| Agitation Speed | 5–60 rpm |
| Agitation Modes | Rocking (4 tilt angles), Reciprocating (4 amplitudes), Rolling (8-bottle capacity), Tube Inversion (96 × 1.5/2.0 mL microtubes) |
| Heating Power | 300 W |
| Display | Digital LED |
| Safety Features | Dual overheat protection, motor overload cutoff, voltage/current surge protection, temperature controller self-diagnosis, sensor fault indication |
| Dimensions (W×D×H) | 425 × 445 × 445 mm |
| Weight | ~30 kg |
| Power Supply | AC 100 V, 4 A |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | M·BR-024 |
| Instrument Type | Air-jacketed Temperature-Controlled Orbital Shaker |
| Timer Range | 60-minute mechanical timer |
| Oscillation Frequency | 100–1,200 rpm |
| Oscillation Mode | Horizontal eccentric motion |
| Temperature Range | +5 °C (ambient +5 °C) to +65 °C |
| Temperature Accuracy | ±0.3–1.0 °C |
| Heating Power | 80 W |
| Platform Capacity | 4 standard microplates (e.g., 96-well) or 2 microtube clamps (e.g., EM-0836/EM-1036) |
| Display | Dual digital LED (switchable between temperature and speed) |
| Dimensions (W×D×H) | 300 × 377 × 318 mm |
| Weight | ~12 kg |
| Power Supply | AC 100 V / 2 A |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | M·BR-420FL |
| Temperature Range | +4°C to +70°C |
| Temperature Accuracy | ±0.3°C to ±1.0°C |
| Oscillation Speed | 200–1500 rpm (reversible mode ≤1000 rpm) |
| Timer Range | 00h00m to 99h59m |
| Oscillation Mode | Horizontal eccentric motion with reversible function |
| Heating Power | 800 W |
| Cooling System | Compressor-based refrigeration (140 W) |
| Display | Digital LED for temperature and speed |
| Programmable Profiles | 4 programs × 9 steps (temperature, speed, time, hold function) |
| Dimensions (W×D×H) | 600 × 732 × 643 mm |
| Weight | ~100 kg |
| Electrical Supply | AC 100 V, 12 A |
| Platform Capacity | Up to 24 microplates (4 layers × 6 positions) or 12 deep-well plates (2 layers × 6 positions) |
| Operating Ambient Temperature | +5°C to +35°C |
| Compliance | Designed for GLP-compliant labs |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | EVR-034 / EVR-032 / EVR-104 |
| Oscillation Speed | 200–1600 rpm |
| Platform Capacity | 4 × 96-well plates or 4 × microtube fixtures |
| Power Supply | AC 100 V, 0.5 A |
| Operating Temperature Range | +5 °C to +40 °C |
| Dimensions (EVR-034) | 342 × 405 × 100 mm |
| Weight | ~10 kg |
| Safety Features | Fuse, motor overload protection, overvoltage protection |
| Compliance | Designed for 3Q qualification (IQ/OQ/PQ) in GLP/GMP environments |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | MBR-022UP |
| Temperature Range | +15°C to +60°C |
| Temperature Uniformity | ±0.1°C |
| Capacity | 2 × 96-well microplates or up to 48 × 1.5 mL microtubes |
| Oscillation Mode | Horizontal orbital shaking |
| Speed Range | 300–2500 rpm |
| Cooling/Heating System | Solid-state Peltier module |
| Display | Digital temperature & speed readout |
| Programmable Profile | 1 program, 9 segments (temperature/time) |
| Dimensions (W×D×H) | 270 × 377 × 245 mm |
| Weight | ~12 kg |
| Power Supply | AC 100 V, 1.5 A |
