| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | BHC-1300 II A/B2 |
| Price | USD 6,050 (FOB Jiangsu) |
| Certification | EN 12469:2000, ISO 14644-1 Class 5 (ISO Class 5), NSF/ANSI 49-2022 Compliant |
| Airflow Velocity (Inflow) | 0.35 ± 0.025 m/s |
| Downflow Velocity (Work Area) | 0.26–0.38 ± 0.025 m/s |
| Filtration Efficiency | ≥99.99% @ 0.3 µm (HEPA H14 per EN 1822) |
| Noise Level | ≤62 dB(A) |
| Illumination | ≥300 lx |
| Vibration | ≤5 µm (peak-to-peak) |
| Power Supply | AC 220 V / 50 Hz |
| Max. Power Consumption | 600 W |
| Net Weight | <250 kg |
| Work Area Dimensions | 1000 × 650 × 580 mm |
| External Dimensions | 1300 × 800 × 1950 mm |
| HEPA Filter Size | 995 × 640 × 50 mm (1 unit) |
| UV Lamp | 20 W × 1 |
| Fluorescent Lamp | 20 W × 1 |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | Biolot 100 |
| Purification Principle | Gel Filtration Chromatography (GFC) |
| Detector Types | UV-Vis Absorbance Detector, Conductivity Detector, pH Detector |
| Wavelength Range | 190–800 nm |
| Flow Rate Range | 0.01–100 mL/min |
| Pressure Range | 0–20 MPa |
| Gradient Accuracy | ±0.5% ABS (dual-pump system) |
| Conductivity Range | 0–999.9 mS/cm |
| pH Range | 0–14 |
| Fraction Collector Capacity | 2 × 60 tubes (15 mm × 150 mm) |
| Software Compliance | CFDA GxP & FDA 21 CFR Part 11 |
| Brand | Bionavis |
|---|---|
| Origin | Finland |
| Model | MP-SPR Navi 200 OTSO |
| Sample Volume | 250 µL |
| Injection Volume | 50 µL |
| Analysis Time | 5–10 min |
| Temperature Control Range | 15–45 °C (ambient ±7 °C / +20 °C) |
| Brand | Bionavis |
|---|---|
| Origin | Finland |
| Model | MP-SPR Navi 210A VASA |
| Sample Volume | 250 µL |
| Injection Volume | 50 µL |
| Analysis Time | 5–10 min |
| Temperature Control Range | 15–45 °C (ambient ±7 °C / +20 °C) |
| Brand | Bionavis |
|---|---|
| Origin | Finland |
| Model | MP-SPR Navi 220A NAALI |
| Sample Volume | 250 µL |
| Injection Volume | 50 µL |
| Analysis Time | 5–10 min |
| Temperature Control Range | 15 °C–45 °C (ambient ±7 °C / +20 °C) |
| Angular Scan Range | 40°–78° |
| Angular Resolution | 0.001° |
| Laser Wavelengths | 670 nm (standard), optional dual-wavelength (670 nm + 785 nm) |
| Refractive Index Range | 1.00–1.40 (bulk), extendable for high-RI materials (e.g., diamond-like carbon, n ≈ 2.7) |
| Flow Rate | 1–1000 µL/min |
| Sensitivity | 1 µRIU (refractive index unit), 1 pg/mm² (protein surface coverage) |
| Kinetic Range | kₐ = 10³–10⁸ M⁻¹s⁻¹, k = 10⁻⁷–0.1 s⁻¹, K_D = 10⁻¹²–10⁻³ M |
| Detection Limit | <100 Da (liquid phase), H₂ (2 Da, gas phase) |
| Noise | Short-term ≤0.3 µRIU, Drift <1 µRIU/min |
| Flow Channels | 2 independent, switchable in series or parallel |
| Sensor Chip Compatibility | Au, Ag, Cu, Pt, SiO₂, Al₂O₃, TiO₂, CMD, Ni²⁺, custom functionalized surfaces |
| Flow Cell Options | PDMS (1 µL/channel), PEEK (SPR305-MS), electrochemical (SPR321-EC), gas-phase (SPR310-GS), fast-kinetics (SPR302-LS), or custom |
| Brand | Bionavis |
|---|---|
| Origin | Finland |
| Model | MP-SPR Navi 400 KONTIO |
| Sample Volume | 250 µL |
| Injection Volume | 50 µL |
| Analysis Time | 5–10 min |
| Temperature Control Range | 15–45 °C |
| Angular Measurement Range | 40–78° |
| Angular Resolution | 0.001° |
| Flow Rate | 10–400 µL/min |
| Laser Wavelengths | 670 nm (standard), optional dual-wavelength (670 nm + 785 nm) |
| Refractive Index Range | 1.00–1.40 (bulk), extendable for high-RI materials (e.g., diamond-like carbon, n ≈ 2.7) |
| Thickness Measurement Range | Å to µm (material-dependent) |
| Kinetic Constants | kₐ = 10³–10⁸ M⁻¹s⁻¹, k = 10⁻⁷–0.1 s⁻¹, K = 10⁻¹²–10⁻³ M |
| Sensitivity | 1 µRIU, 1 pg/mm² (protein coverage) |
| Minimum Detectable Mass | 2 Da (gas phase), <100 Da (liquid phase) |
| Short-term Noise | 0.3 µRIU, Baseline Drift: <1 µRIU/min |
| Flow Channels | 4 (PDMS microfluidic cell) |
| Detection Modes | Angle-scan (full SPR curve) and fixed-angle (kinetic mode, up to 1 ms sampling) |
| Brand | Bionavis |
|---|---|
| Origin | Finland |
| Model | MP-SPR Navi 410A KAURIS |
| Sample Volume | 250 µL |
| Injection Volume | 50 µL |
| Analysis Time | 5–10 min |
| Temperature Control Range | 15–45 °C (ambient ±7 °C / +20 °C) |
| Angular Measurement Range | 40–78° |
| Angular Resolution | 0.001° |
| Flow Rate | 1–1000 µL/min |
| Laser Wavelengths | 670 nm (standard), optional dual-wavelength (670 nm + 785 nm) |
| Refractive Index Range (bulk) | 1.00–1.40 (expandable with multi-wavelength) |
| Thickness Measurement Range | Å to µm (material-dependent) |
| Kinetic Constants | kₐ = 10³–10⁸ M⁻¹s⁻¹, kₑ = 10⁻⁷–0.1 s⁻¹, K<sub>D</sub> = 10⁻³–10⁻¹² M |
| Sensitivity | 1 µRIU |
| minimum detectable mass | <100 Da (liquid phase), 2 Da (gas phase) |
| Short-term Noise | 0.3 µRIU |
| Baseline Drift | <1 µRIU/min |
| Detection Channels | 4 independent flow channels |
| Auto-sampler Capacity | 7 samples |
| Software | MP-SPR Navi™ Control & Data Viewer, TraceDrawer™, LayerSolver™ (optional) |
| Brand | Bionavis |
|---|---|
| Origin | Finland |
| Model | MP-SPR Navi 420A ILVES |
| Sample Volume | 250 µL |
| Injection Volume | 50 µL |
| Analysis Time | 5–10 min |
| Temperature Control Range | 15–45 °C (ambient ±7 °C / +20 °C) |
| Brand | Biopharma |
|---|---|
| Origin | United Kingdom |
| Model | LyoStat5 |
| Application | In-situ freeze-drying process visualization and thermal transition analysis |
| Cooling System | Automated dual-pump liquid nitrogen system with 2 L Dewar and insulated flexible transfer lines |
| Vacuum Control | Motorized, digitally regulated vacuum valve with pressure display in mbar, kPa, and mTorr |
| Optical System | High-transmission, low-aberration modular optics with integrated high-brightness LED illumination (rated >60,000 h) |
| Imaging | USB 3.0 digital camera (1920 × 1080 resolution, 60 fps), real-time video capture and time-stamped image logging up to 80 GB storage |
| Software | LyoView™ v5.2 — fully programmable temperature ramp/hold profiles, synchronized pressure logging, event-triggered image capture, audit-trail enabled for GLP/GMP environments |
| Compliance | Designed to support ASTM F2721-22 (Standard Guide for Characterization of Freeze-Dried Protein Pharmaceuticals), ISO 22675:2021 (Pharmaceutical freeze-drying process development), and FDA 21 CFR Part 11-compliant data integrity workflows |
| Brand | TMAXTREE |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fully Automatic |
| Detection Method | Enzyme-Linked Electrode Sensor Array |
| Measurable Analytes | Glucose, Lactose, Galactose, Glutamic Acid, Glutamine, Lysine, Xylose, Glycerol, Lactic Acid, Ethanol, Methanol |
| Accuracy | <3% Full Scale |
| Sample Throughput | 50 samples/hour |
| Dimensions | 550 × 502 × 760 mm |
| Brand | Bioptechs |
|---|---|
| Origin | USA |
| Model | Delta T |
| Microscope Type | Upright Microscope |
| Sample Chamber | 35 mm Standard Petri Dish with Bonded 170 µm Glass Coverslip |
| Temperature Control Method | ITO (Indium Tin Oxide) Transparent Heated Layer on Coverslip Bottom |
| Temperature Feedback | External Thermistor |
| Thermal Response Rate | ~0.1 °C/s |
| Compatible Imaging Modes | Brightfield, Darkfield, Polarized Light, Phase Contrast, DIC, HMC, Fluorescence, Multiphoton, Confocal |
| Coverslip Options | Stress-Free Glass, Variable Thickness (Including High-NA Optimized) |
| Adapter Support | Brain Slices, Monolayer Cultures, Tissue Explants, Small-Area Cell Preparations |
| Compliance Context | Designed for GLP/GMP-aligned live-cell imaging workflows requiring thermal stability and environmental reproducibility |
| Brand | Bioptic |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Instrument |
| Model | GL100/400 |
| Instrument Classification | Conventional Nucleic Acid and Protein Analyzer |
| Minimum Sample Volume | 1 µL |
| Detection Technology | Capillary Gel Electrophoresis (CGE) with LED-Induced Fluorescence (LEDIF) |
| Sample Throughput | 96-well Auto-sampler |
| Consumable Format | Disposable Pre-cast Gel Cartridge |
| Included Modules | Integrated Sample Prep Platform (N-Glycan Release, Labeling & Purification Kit), Analysis Software with Data Export & Reporting Engine |
| Brand | Bioptic |
|---|---|
| Model | Qsep Mini |
| Origin | Jiangsu, China |
| Instrument Category | Ultra-micro Nucleic Acid and Protein Analyzer |
| Sample Volume Requirement | 1 µL |
| Analyte Types | DNA, Proteins |
| DNA Detection Limit | pg-level |
| Module Options | 8-, 12-, or 19-sample capacity |
| Disposables | Pre-cast, single-use gel cartridges |
| Brand | Bioptic |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Qsep1 |
| Instrument Classification | Conventional Nucleic Acid and Protein Analyzer |
| Minimum Sample Volume | 1 µL |
| Compatible Capillary Cartridges | 8-well, 12-well templates (Qsep1/Qsep1 Advance/Qsep1-Lite) |
| Form Factor | Portable Benchtop Analyzer |
| Brand | Bioptic |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Instrument |
| Model | Qsep100 Advance |
| Pricing | Upon Request |
| Instrument Classification | Conventional Nucleic Acid and Protein Analyzer |
| Minimum Sample Volume | 1 µL |
| Brand | Bioptic |
|---|---|
| Model | Qsep100 |
| Origin | Jiangsu, China |
| Instrument Type | Ultra-micro Nucleic Acid and Protein Analyzer |
| Sample Volume Requirement | 1 µL |
| Distribution Channel | Authorized Distributor (Non-Manufacturer) |
| Category | Benchtop Capillary Electrophoresis System |
| Brand | Bioptic |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Qsep400 |
| Sample Volume Requirement | 1 µL |
| Instrument Classification | Conventional Nucleic Acid & Protein Analyzer |
| Brand | Biopticon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | TumorImager 2 |
| Instrument Type | Optical 3D Surface Imaging System |
| Scan Resolution | 480 × 640 pixels |
| Scan Speed | <1 s per acquisition |
| Field of View | 30 mm × 20 mm |
| Sample Capacity | 1 animal per scan |
| Z-Axis Resolution | 50 µm |
| Interface | USB 3.0 |
| Output Formats | JPG (2D), OBJ & PLY (3D surface mesh) |
| Operating Modes | Handheld or Stand-Mounted |
| Tumor Length Limit | ≤30 mm |
| Tumor Height Limit | ≤20 mm |
| Automatic Segmentation Time | ~3 s |
| Data Storage | Local SQL database with user authentication and audit trail |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Range | BioS 50L–2000L |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | BIO-DWB |
| Price Range | USD 1,400 – 7,000 |
| Sensor Accuracy (Mouse) | ±1 g |
| Sensor Resolution (Mouse) | 0.2 g |
| Sensor Range (Mouse) | 15–50 g |
| Sensor Range (Rat) | 150–500 g |
| Sensor Resolution (Rat) | 0.8 g |
| Chamber Dimensions (Mouse) | 11.5 × 11.5 × 22 cm (L×W×H) |
| Chamber Dimensions (Rat) | 22 × 22 × 30 cm (L×W×H) |
| External Dimensions (Mouse) | 17 × 17 × 22 cm |
| External Dimensions (Rat) | 30 × 30 × 35 cm |
| Weight (Mouse Unit) | 1 kg |
| Weight (Rat Unit) | 2.5 kg |
| Floor Material | Gray Polypropylene Copolymer (PPC) |
| Wall Material | Transparent PPC |
| Interface | USB 2.0 |
| OS Compatibility | Windows 7 or later |
| Minimum CPU | Intel Core i3 or i5 |
| Minimum RAM | 3 GB |
| Origin | Italy |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | BIO-EVF3 |
| Price | Upon Request |
| Measurement Range | 0–500 g (0–5 N) |
| Resolution | 0.1 g |
| Accuracy | ±0.2 g |
| Internal Memory | 100 Test Records |
| Includes | 10 Disposable Plastic Filaments + 1 Elastic Filament (Rat/Mouse Compatible) |
| Brand | Bioseb |
|---|---|
| Model | BIO-EVF3 |
| Measurement Principle | Precision resistive force transduction |
| Range | 0–500 g (0–5 N) |
| Accuracy | ±0.2 g |
| Resolution | 0.1 g |
| Overload Capacity | 120% (6 N) without sensor damage |
| Temperature Compensation | 0–50 °C |
| Data Storage | Up to 100 measurements internally |
| Interface | RS-232 (with optional RSIC software) |
| Compliance | COFRAC-accredited calibration (ISO 9001), EMC certified |
| Probe Types | Rigid plastic probe (rat), flexible elastomeric probe (mouse) |
| Display | Backlit LCD with real-time force reading and peak-hold function |
| Control | Footswitch-enabled zeroing and measurement freeze (“Patient” mode) |
| Statistical Functions | Automatic mean and standard deviation calculation |
| Accessories | Included transport case, optional BIO-VF-M filament set (20 calibrated filaments, forces from 0.008 g to 300 g) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BIO-FMA |
| Price Range | USD 1,400 – 7,000 |
| Data Acquisition Rate | 10 ms |
| Sensor Count | 154 (dual infrared arrays, 77 per side) |
| Dimensions (L×W×H) | 124 × 28 × 20 cm |
| Runway Width | 80 mm (rat), 50 mm (mouse), interchangeable |
| Bar Spacing | Adjustable from 25 px to 75 px (≈0.6–1.9 mm, software-calibrated pixel-to-mm mapping) |
| Bar Height | Adjustable |
| Start Box Illumination | Cold-white LED flash, software-controllable intensity and timing |
| Interface | USB 2.0 |
| Power Supply | Standard AC adapter (100–240 V, 50/60 Hz) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BIO-FSTR/M |
| Price Range | USD 1,400 – 7,000 |
| Capacity | 4 simultaneous mice |
| Cylinder Dimensions | 11.7 cm (diameter) × 15.9 cm (height) |
| Detection Method | Dual-modal (video + piezoelectric vibration sensing) |
| Behavioral Classification Accuracy | ≥96% |
| Output Data Format | Timestamped behavioral state sequence (Immobility/Swimming/Climbing), raw video + vibration waveform export |
| Software Features | Playback, re-analysis, GLP-compliant audit trail, CSV/Excel export |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | BIO-GRADIENT |
| Channel Configuration | 1-channel (2 mice or 1 rat) / 2-channel (4 mice or 2 rats) |
| Overall Dimensions (L×W×H) | 139 × 30 × 40 cm (1-channel) |
| Weight | 25 kg (1-channel) |
| Runway Dimensions | 125 × 10 × 15 cm (per runway) |
| Temperature Range | 5–55 °C (floor surface) |
| Temperature Stability | ±1 °C |
| Floor Material | Anodized aluminum heating plate |
| Wall & Lid Material | Gray PPC-coated polycarbonate walls, transparent PPC lid |
| Detection Resolution | Up to 20 discrete temperature zones per animal |
| Output Metrics | Position-resolved dwell time per zone, cumulative path length, zone transition frequency, thermal preference index (TPI), latency to first entry into target zones |
| Origin | Italy |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | BIO-GS3 |
| Price Range | USD 7,000 – 14,000 |
| Force Range | 0–2000 g |
| Resolution | 0.1 g |
| Sampling Rate | 1000 Hz |
| Max Load Capacity | 2000 g |
| Sensor Accuracy | < ±0.25% FS |
| Display Units | g, N, lb |
| Data Storage | ≥100 tests |
| Interface | RS232 / USB |
| Forelimb Bar Dimensions | 76 mm × 50 mm |
| Hindlimb Bar Dimensions | 127 mm × 127 mm |
| Software | BIO-CIS Grip Strength Analysis Suite |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BIO-KWB |
| Price Range | USD 1,400 – 7,000 |
| Footprint (Rat System) | 130 × 50 × 45 cm |
| Footprint (Mouse System) | 80 × 40 × 30 cm |
| Camera Resolution | 640 × 480 |
| Camera Frame Rate | 30 Hz |
| Force Sensor Sampling Rate | 100 Hz |
| Software | KWB Full-Function License (Unlimited Replay Mode, Unlimited PC Installations) |
| OS Compatibility | Windows 7 or later |
| Minimum CPU | Intel Core i5 or equivalent |
| Minimum RAM | 4 GB |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | BIO-T2CT |
| Temperature Range | –3 °C to 65 °C (ambient 20–25 °C) |
| Temperature Accuracy | ±0.5 °C |
| Power Consumption | 150 W |
| Dimensions (L×W×H) | 32 cm × 57 cm × 45.5 cm |
| Cage Dimensions | 330 mm × 165 mm × 300 mm |
| Cage Material | Optical-grade acrylic |
| Monitoring Metrics | Dwell time per zone, entry latency, real-time position, zone-specific temperature, timestamp |
| Software Option | Optional automated video-tracking and thermal-zone logging module |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BIO-T2CT |
| Price Range | USD 6,800 – 13,600 (FOB Europe) |
| Origin | France |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | BIO-T2CT (supports 1 rat or 2 mice |
| Pricing | Upon Request |