- All
- Favorite
- Popular
- Most rated
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-TGA101 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1200 °C |
| Balance Sensitivity | 0.1 mg to 3 g (standard range), 1 mg to 2 g (high-precision range) |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Balance Accuracy | 0.01 mg |
| Minimum Mass Resolution | 0.1 µg |
| Isothermal Hold Duration | Up to 72 h (0–300 min programmable in 0.1 min increments) |
| Atmosphere Control | Dual-gas channel with integrated mass flow meters |
| Display | 7-inch high-resolution Chinese-language LCD touchscreen |
| Data Interface | Standard USB port |
| Software | Proprietary TGA analysis suite with TG/DTG curve fitting, Excel export, PDF report generation, thermal calibration correction (multi-point), and FDA 21 CFR Part 11–compliant audit trail (optional module) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TGA 101 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Balance Range | 0.01 mg–2 g (expandable to 30 g) |
| Balance Sensitivity | 0.01 mg |
| Minimum Detection Limit | 0.1 µg |
| Isothermal Hold Duration | 0–500 min (extendable to 72 h) |
| Atmosphere Control | Dual-gas inlet with integrated mass flow meters |
| Display | 7-inch Chinese-language LCD |
| Data Interface | Standard USB |
| Software | Proprietary TGA analysis suite with TG/DTG curve processing, Excel export, PDF report generation, temperature multi-point calibration, and free version upgrades |
| Power Supply | AC 220 V, 50 Hz (customizable) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DZ-TGA101 |
| Price Range | USD 7,000–14,000 (FOB) |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single-sample |
| Instrument Type | General-purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Balance Sensitivity | 0.1 mg to 3 g (standard), extendable to 30 g |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Atmosphere Control | Dual-gas channel with mass flow control (inert, oxidizing, reducing, static, dynamic) |
| Data Interface | USB 2.0 |
| Software | Proprietary TGA analysis suite with TG/DTG curve fitting, Excel/PDF export, GLP-compliant audit trail, multi-point temperature calibration, and remote instrument control |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-TGA101 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1200 °C |
| Balance Sensitivity | 0.01 mg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Balance Range | 0.1 mg–3 g (extendable to 30 g) |
| Isothermal Hold Duration | Up to 72 h (0–300 min programmable in 0.1 min increments) |
| Atmosphere Control | Dual-gas manifold with mass flow regulation (inert, oxidative, reductive, static, dynamic) |
| Data Acquisition | 48-bit quadruple-channel ADC for simultaneous TG, DTG, DSC (optional), and temperature signals |
| Interface | USB 2.0 (bidirectional) |
| Display | 7-inch 24-bit color touchscreen (Chinese/English UI) |
| Calibration | On-screen TG baseline and temperature multi-point calibration |
| Power Supply | AC 220 V, 50 Hz (customizable) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TGA 101 |
| Sample Capacity | Single-sample |
| Instrument Type | Dedicated TGA System |
| Temperature Range | Ambient to 1550 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Balance Range | 0.1 mg–2 g (extendable to 30 g) |
| Mass Sensitivity | 0.01 mg |
| Cooling Time | ≤15 min (from 1000 °C to 100 °C) |
| Data Interface | Standard USB 2.0 |
| Power Supply | AC 220 V, 50 Hz |
| Brand | NANJING DAZHAN |
|---|---|
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1200 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Max Sample Mass | 30 g |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidative, reductive, static/dynamic) |
| Balance Resolution | 0.1 µg |
| Balance Accuracy | ±0.01 mg |
| Temperature Stability | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Display | 7-inch 24-bit color touchscreen |
| Communication | USB 2.0 bidirectional interface |
| Software | Integrated TGA analysis suite with TG/DTG curve fitting, multi-point temperature calibration, Excel/PDF export, GLP-compliant report generation |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Region Classification | Domestic (PRC) |
| Model | DZ-TGA201 |
| Pricing | Upon Request |
| Temperature Range | Ambient to 1250 °C |
| Mass Resolution | 1 µg |
| Mass Accuracy | ±1 µg |
| Dynamic Weighing Capacity | 0.01 mg–3 g (expandable to 50 g) |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Load | 50 g |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1200 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| Maximum Sample Mass | 30 g |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidizing, reducing, static, dynamic) |
| Balance Sensitivity | 0.01 mg |
| Balance Range | 0.01 mg–3 g (extendable to 30 g) |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Programmable Stages | Up to 5 temperature segments |
| Isothermal Hold Duration | 0–300 min per segment (configurable up to 72 h total) |
| Display | 7-inch Chinese-language LCD |
| Interface | USB 2.0 |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DZ-TGA101 |
| Testing Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Dynamic Weighing Range | 0.01 mg to 3 g |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-TGA101 |
| Price Range | USD 7,000–14,000 (FOB) |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1200 °C |
| Balance Sensitivity | 0.1 µg (Resolution), 0.01 mg (Accuracy) |
| Mass Range | 0.01 mg–2 g (expandable to 30 g) |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Isothermal Hold Duration | 0–500 min (extendable to 72 h) |
| Atmosphere Control | Dual-gas inlet with mass flow control (inert, oxidizing, reducing, static, dynamic) |
| Display | 7-inch 24-bit color capacitive touchscreen |
| Data Interface | Standard USB 2.0 |
| Software | Proprietary Windows-based TGA analysis suite with ASTM/ISO-compliant reporting, Excel export, PDF report generation, multi-point temperature calibration, and full remote instrument control |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1150 °C |
| Temperature Accuracy | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Dynamic Weight Range | 0.01 mg to 3 g |
| Balance Sensitivity | 0.01 mg (up to 2 g), extendable to 30 g |
| Mass Accuracy | 0.01 mg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass Capacity | 30 g |
| Baseline Drift | Negligible (<0.1 µg over 60 min at constant temperature) |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidizing, reducing, static/dynamic) |
| Cooling Time | ≤15 min (1000 °C → 100 °C) |
| Isothermal Hold Duration | 0–500 min (extendable to 72 h) |
| Data Acquisition | 24-bit quadruple-channel ADC for TG, DTG, DSC (optional), and temperature signals |
| Controller Architecture | 32-bit ARM Cortex-M3 microcontroller + dedicated 8-bit MCU for water-cooling subsystem |
| Interface | USB 2.0 (bidirectional), touch-screen and PC remote control supported |
| Software | Integrated Windows-based analysis suite with ASTM/ISO-compliant reporting, multi-point temperature calibration, Excel/PDF export, GLP audit trail logging |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1250 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Mass Range | 0.01 mg–30 g |
| Mass Sensitivity | 0.01 mg |
| Atmosphere Control | Dual-gas channel with mass flow control (inert, oxidizing, reducing, static, dynamic) |
| Display | 7-inch LCD touchscreen |
| Data Interface | USB |
| Software | Integrated TGA analysis suite with TG/DTG curve fitting, multi-point temperature calibration, Excel/PDF export, and GLP-compliant reporting |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-TGA105 |
| Sample Capacity | 1 |
| Instrument Type | Dedicated TGA System |
| Temperature Range | Ambient to 1550 °C |
| Balance Sensitivity | 0.01 mg (full range: 0.1 mg–2 g, extendable to 30 g) |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time | ≤15 min (from 1000 °C to 100 °C) |
| Data Interface | USB 2.0 |
| Power Supply | AC 220 V, 50 Hz |
| Brand | DZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | DZ-TGA201 |
| Structural Design | Top-loading (elevating furnace) |
| Operating Environment | Ambient pressure |
| Sample Capacity | Single sample |
| Instrument Class | General-purpose TGA |
| Temperature Range | Ambient to 1250 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.01 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Dynamic Weighing Range | 0.01 mg to 3 g (extendable to 50 g) |
| Balance Sensitivity | 1 µg |
| Mass Accuracy | ±1 µg |
| Mass Repeatability | ±1 µg |
| Maximum Sample Mass | 50 g |
| Atmosphere Control | Triple-gas mass flow control (inert, oxidative, reducing) |
| Cooling Time | ≤20 min (1000 °C → 50 °C) |
| Temperature Control Algorithm | Adaptive PID with self-tuning and memory-based multi-segment programming |
| Exhaust Interface | Dedicated outlet for coupling with FTIR, MS, or GC-MS |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | DZ-TGA101 |
| Test Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Dynamic Weighing Range | 0.01 mg to 3 g |
| Mass Accuracy | ±0.01 mg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Mass Resolution | 0.01 mg |
| Maximum Sample Mass | 30 g |
| Baseline Repeatability | Excellent |
| Baseline Drift | Negligible |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Atmosphere Control | Dual-Gas Flow Regulation (Inert, Oxidizing, Reducing, Static, Dynamic) |
| Data Interface | USB 2.0 |
| Software | Integrated TG/DTG Analysis Suite with Excel Export, PDF Report Generation, Multi-Point Temperature Calibration, and GLP-Compliant Audit Trail |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | DZ-TGA201 |
| Pricing | Upon Request |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1250 °C |
| Temperature Accuracy | ±0.01 °C |
| Dynamic Weighing Range | 0.01 mg to 3 g (expandable to 50 g) |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | 0.1–100 K/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.1 °C |
| Mass Resolution | 0.1 µg |
| Isothermal Hold Duration | Up to 600 min (standard), user-definable |
| Atmosphere Control | Triple-Gas Mass Flow Controller (MFC) System |
| Cooling Time | ≤20 min (1000 °C → 50 °C) |
| Temperature Control Algorithm | Intelligent PID with Self-Tuning & Hybrid Static/Dynamic Optimization |
| Brand | DAZHAN (Nanjing Dazhan Instrument Co., Ltd.) |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1250 °C |
| Mass Range | 0.01 mg – 3 g (expandable to 30 g) |
| Mass Sensitivity | 0.01 mg |
| Heating/Cooling Rate | 0.1 – 100 °C/min |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidative, reductive, static, dynamic) |
| Display | 7-inch 24-bit color touchscreen interface |
| Communication | USB 2.0 bidirectional interface with proprietary PC software |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | DZ-TGA101 |
| Test Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Dynamic Weighing Range | 0.01 mg to 3 g |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Baseline Repeatability | Excellent |
| Baseline Drift | Negligible |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-TGA201 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1250 °C |
| Temperature Resolution | 0.001 °C |
| Temperature Accuracy | ±0.001 °C |
| Dynamic Weighing Range | 0.01 mg to 3 g (expandable to 50 g) |
| Balance Sensitivity | 0.01 µg |
| Mass Accuracy | 0.01 mg |
| Heating Rate | 0.1–100 °C/min |
| Cooling Rate | –0.1 to –40 °C/min |
| Maximum Sample Mass | 30 g |
| Mass Precision | 0.01 mg |
| Temperature Stability | ±0.01 °C |
| Cooling Time (1000 °C → 50 °C) | ≤20 min (standard), ≤15 min with optional cryo-cooling unit |
| Atmosphere Control | Triple-gas mass flow controller |
| Data Acquisition Intervals | Real-time, 2 s, 5 s, or 10 s selectable |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1250 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Mass Range | 0.01 mg–3 g (expandable to 30 g) |
| Mass Sensitivity | 0.01 mg |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidative, reductive, static, dynamic) |
| Data Interface | Standard USB |
| Software | Integrated TGA analysis suite with TG/DTG curve processing, Excel/PDF export, multi-point temperature calibration, and audit-ready reporting |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | DZ-TGA 101 |
| Structure Type | Top-loading / Upper-mounted |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single-sample |
| Instrument Type | General-purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Temperature Accuracy | ±0.01 K |
| Balance Sensitivity | 0.01 mg |
| Heating/Cooling Rate | 1–80 °C/min |
| Maximum Sample Mass | 30 g |
| Baseline Drift | ≤0.1 mg |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.01 °C |
| Mass Range | 0.1 mg–30 g |
| Atmosphere Control | Dual-gas channel with integrated mass flow meters and manual flow regulation |
| Data Interface | Standard USB |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 500×400×430 mm |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | DZ-TGA101 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Dynamic Weighing Range | 0.01 mg to 2 g (extendable to 30 g) |
| Mass Accuracy | 0.01 mg |
| Mass Resolution | 0.1 µg |
| Isothermal Hold Time | 0–500 min (expandable to 72 h) |
| Cooling Time | ≤15 min (from 1000 °C to 100 °C) |
| Atmosphere Control | Dual-gas inlet with integrated mass flow meters |
| Display | 7-inch Chinese-language LCD touchscreen |
| Data Interface | Standard USB port |
| Software | Proprietary TGA analysis suite with multi-point temperature calibration, TG/DTG curve processing, Excel export, PDF report generation, and audit-ready experimental logging |
| Power Supply | AC 220 V, 50 Hz (customizable) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-TGA105 |
| Structure Type | Top-loading (upright) |
| Ambient Pressure Operation | Yes |
| Sample Capacity | 1 sample per run |
| Instrument Class | General-purpose TGA |
| Temperature Range | Ambient to 1550 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Baseline Repeatability | High reproducibility |
| Balance Sensitivity | 0.01 mg |
| Balance Dynamic Range | 0.1 mg–2 g (extendable to 30 g) |
| Cooling Time | ≤15 min (from 1000 °C to 100 °C) |
| Data Interface | USB 2.0 |
| Control Processor | STM32 microcontroller |
| ADC Resolution | 48-bit, quad-channel for TG, DSC (if equipped), and temperature signals |
| Display | 7-inch 24-bit color touchscreen |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DZ-TGA101 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Balance Range | 0.01 mg–2 g (extendable to 30 g) |
| Balance Resolution | 0.1 µg |
| Isothermal Hold Time | 0–500 min (expandable to 72 h) |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Atmosphere Control | Dual-gas flow regulation with inert/oxidizing/reducing/static/dynamic options |
| Data Interface | USB 2.0 |
| Power Supply | AC 220 V, 50 Hz |
Show next