| Material | Precision-Annealed K9 Optical Glass |
|---|---|
| Design Wavelength | 587.6 nm |
| Diameter Tolerance | +0.0 / −0.1 mm |
| Center Thickness Tolerance | ±0.2 mm |
| Surface Irregularity | λ/4 @ 632.8 nm |
| Effective Focal Length (EFL) Tolerance | ±2% |
| Lens Centration Error | 3 arcmin |
| Surface Quality | 3–4 scratch-dig |
| Edge Treatment | 0.2 mm × 45° chamfer |
| Coating | Uncoated (optional AR coatings: UV, VIS, NIR, SWIR) |
| Substrate Applicability | K9 standard |
| Material | Precision-Annealed K9 Optical Glass |
|---|---|
| Design Wavelength | 587.6 nm |
| Diameter Tolerance | +0.0 / −0.1 mm |
| Center Thickness Tolerance | ±0.2 mm |
| Surface Irregularity | λ/4 @ 632.8 nm |
| EFL Tolerance | ±2% |
| Centration Error | ≤3 arcmin |
| Surface Quality | 3–4 scratch-dig |
| Edge Treatment | 0.2 mm × 45° chamfer |
| Coating Options | Uncoated |
| Material | Precision-Annealed K9 Optical Glass |
|---|---|
| Design Wavelength | 587.6 nm |
| Diameter Tolerance | +0.0 / −0.1 mm |
| Center Thickness Tolerance | ±0.2 mm |
| Surface Irregularity | λ/4 @ 632.8 nm |
| EFL Tolerance | ±2% |
| Centration Error | ≤3 arcmin |
| Surface Quality | 3–4 scratch-dig |
| Edge Treatment | 0.2 mm × 45° chamfer |
| Coating Options | VIS AR (400–700 nm), NIR AR (650–1050 nm), SWIR AR (1000–1650 nm) |
| Brand | auniontech (distributor) |
|---|---|
| Origin | Switzerland |
| Product Type | Motorized Liquid Lens Integration Module |
| Mount | S-Mount & C-Mount |
| Sensor Compatibility | 4/3" Format |
| Focal Length Range | 5–300 mm |
| Aperture | Low f-number, vignetting-free design |
| Form Factor | Compact integrated optical module |
| Compliance | Designed for industrial vision integration per ISO 10110 optical manufacturing standards |
| Brand | Auniontech (Distributor) |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Optical Instrument Component |
| Model Designation | ELM-T Series Telecentric Lens Module |
| Pricing | Available Upon Request |
| Brand | Orient KOJI |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | AO8310 |
| Component Category | Optical Element |
| Dimensions | 50 × 50 mm |
| Included Filters | 7 pieces with center wavelengths at 290–380 nm (broadband), 300 nm, 320 nm, 360 nm, 400 nm, 450 nm, and 510 nm |
| Brand | Orient KOJI |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EzTime-PL |
| Price Range | USD 1,400 – 7,200 (est.) |
| Component Type | Optical Instrument Module |
| Excitation Wavelength Range | 375–2200 nm |
| Pulse Width Tuning | 25 ns – 500 ms (continuous) |
| Repetition Rate | 0.01 Hz – 1 kHz |
| Lifetime Detection Range | 1 µs – 10 s |
| Output Stability (CW) | < 2% RMS |
| Electrical Rise/Fall Time | < 1 ns (50 Ω load) |
| Max. Optical Power | 5 W (configurable) |
| Synchronization Interface | TTL-compatible trigger output & input |
| Compatible Systems | HORIBA FluoroLog/FLS, Edinburgh Instruments FLS series, Becker & Hickl TCSPC MCS/Phosphorescence modes |
| Brand | Bakman |
|---|---|
| Origin | USA |
| Model | PB7220-2000-T |
| Center Frequency | 1850 GHz |
| Frequency Resolution | 1000 MHz |
| Component Type | Optical Component |
| Distribution Status | Authorized Distributor |
| Brand | PD-LD |
|---|---|
| Origin | USA |
| Component Type | Optical Element |
| Available Configurations | Lensed VBG, Chirped VBG (Transverse & Longitudinal), Fixed-Reflectivity VBG, Variable-Reflectivity VBG |
| Center Wavelength Range | 400 nm – 2500 nm |
| Typical Center Wavelengths | 785 nm, 808 nm, 976 nm, 1064 nm |
| Wavelength Accuracy | ±0.5 nm |
| FWHM Line-width | ≤1.0 nm |
| Thermal Wavelength Drift | ≤0.01 nm/°C |
| Polarization Dependent Loss | ≤0.1 dB |
| Operating Temperature | –40°C to +130°C |
| Storage Temperature | –40°C to +130°C |
| Acceptance Angle | ±5° |
| Standard Dimensions | Single Emitter (1.5 mm × 2.0 mm), Diode Bar (1.5 mm × 15 mm), 2D Array (15 mm × 15 mm), Wafer Format (30 mm × 30 mm) |
| Brand | Cinch Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | PECK06 |
| Component Category | Optical Component |
| Cell Volume | <5 mL |
| Electrode Configuration | Pt wire counter electrode, Ag/AgCl reference electrode, Pt disk working electrode |
| Construction Material | Machined PTFE body with fused silica optical window |
| Optical Window | UV-grade fused silica (transmission range: 180–2500 nm) |
| Working Electrode-to-Window Distance | Adjustable (range: 0.5–5.0 mm) |
| Gas Inlet/Outlet Ports | Dual stainless steel Swagelok® fittings (1/4"-28 UNF) |
| Sealing | O-ring sealed, vacuum-tight to 1 × 10⁻³ mbar |
| Brand | Cinch Photonics |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Producer |
| Origin Category | Domestic (China) |
| Model | PECK11S |
| Unit Price | USD 1,280 |
| Component Category | Optical & Electrochemical Cell Assembly |
| Cell Volume | 50 mL |
| Construction | Borosilicate Glass Body |
| Top Seals | Two PTFE Caps with Threaded Electrode Ports |
| Quartz Optical Windows | Ø24 mm, UV-Grade Fused Silica |
| Electrode Compartment Isolation | Removable Ion-Exchange Membrane or Fritted Glass Disc (Porosity: #3–#4) |
| Temperature Control Method | Double-Jacketed Water Circulation (Compatible with LX/HX Series Recirculating Chillers) |
| Standard Electrodes | Pt Wire Counter Electrode, Ag/AgCl (3 M KCl) Reference Electrode, Pt Electrode Holder for Working Electrode |
| Customization Options | Adjustable Port Diameter/Quantity, Single-Compartment Volumes up to 150 mL, Optional Quartz or CaF₂ Windows |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | UVCUT420 |
| Component Type | Optical Filter |
| Substrate Material | Fused Silica (Quartz) |
| Diameter | 63 mm |
| Clear Aperture | >57 mm |
| Cut-on Wavelength | 420 nm (typical, long-wave pass configuration) |
| Spectral Performance | High OD (>4) below cutoff, >90% average transmission above cutoff |
| Surface Quality | 20–10 scratch-dig |
| Parallelism | <1 arcmin |
| Thickness | 3.0 ± 0.1 mm |
| Coating | Hard-dielectric multilayer on both sides |
| Brand | PerfectLight |
|---|---|
| Model | Vlight |
| Type | Multi-Channel Solar-Simulating Light Panel |
| Spectral Range | 380–760 nm |
| AM1.5G Spectral Match Accuracy | ±15% |
| Irradiance Output | 100–450 mW/cm² |
| Input Power | 10 W |
| Compatibility | PCX50B and PCX50C Multi-Channel Photocatalytic Reaction Systems |
| Origin | Beijing, China |
| Component Category | Optical Instrument Subassembly |
| Brand | Phaseform |
|---|---|
| Origin | Germany |
| Type | Imported Optical Component |
| Mounting | Transmissive, Polarization-Insensitive |
| Operating Principle | Refractive Microfluidic MEMS-Based Phase Modulation |
| Zernike Mode Support | Up to 7th Radial Order (Open-Loop) |
| Wavelength Range | Visible Spectrum (400–700 nm) |
| Aperture | Standard Clear Pupil Diameter (Customizable) |
| Electrode Layout | Intra-Aperture Electrode Array |
| Compliance | ISO 10110-7 (Optical Surface Irregularity), RoHS, CE Marked |
| Software Interface | Phaseform DPP Control SDK (C++/Python), Compatible with Zemax OpticStudio & Code V Ray Tracing Environments |
| Brand | Photek |
|---|---|
| Origin | United Kingdom |
| Model | Photek Series (MCP-PMT) |
| Spectral Range | 100–900 nm |
| Response Time | < 100 ps (typ.) |
| Window Options | UV-fused silica, MgF₂, borosilicate glass |
| Photocathode Types | Solar-blind (Cs-Te), Bialkali (S-20), GaAsP, Multi-Anode (MA-PMT) |
| Component Category | Optical Detector |
| Key | Brand: Edmund Optics |
|---|---|
| Model | NewOpto |
| Full-Scale Input Range | ±20 nA to ±20 mA (decade steps, 1 pA resolution) |
| Bias Voltage | Selectable from –14 V to +14 V (6.5 mV increments) |
| A/W Calibration Factor | 0.100–1.000 A/W (0.005 increments) |
| Analog Output | ±2 V (corresponds to ±20,000 counts of selected range) |
| Frequency Response | DC–40 kHz (least sensitive range), DC–2 kHz (most sensitive range) |
| Display | 4½-digit LCD (0.4" height) |
| Noise & Drift | <1 pA over 5 s (most sensitive range) |
| Output Impedance | 100 Ω |
| Power | Rechargeable Ni-MH battery (≈10 h operation) or external 85–250 VAC, 50–60 Hz (<9 VA) |
| Dimensions | 140 mm (W) × 63 mm (H) × 215 mm (L) |
| Weight | 0.9 kg (excluding external PSU) |
| Operating Temperature | 0–40 °C |
| Interfaces | RS-232 serial port, analog output port |
| Accessories | RS-232 cable, AC/DC power supply & charger, operator manual |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Regional Origin | Domestic (China) |
| Model | Customizable (e.g., Pt005, Pt010, Pt015, Pt017, or sheet/mesh variants) |
| Price Range | USD 0.15 – 75.00 per unit (based on configuration) |
| Component Category | Optical & Electrochemical Instrument Component |
| Platinum Purity | ≥99.95% |
| Electrode Stem Material | Borosilicate Glass or PTFE |
| Stem Diameter | 6 mm or 8 mm (PTFE) |
| Sheet Dimensions | 5×10 mm to 20×20 mm |
| Sheet Thickness | 0.1–0.5 mm |
| Mesh Specification | 52 mesh |
| Wire Diameters | 0.5 mm or 1.0 mm |
| Wire Lengths | 5–37 mm |
| Brand | AOE Tech |
|---|---|
| Model | PMIWDM |
| Category | Polarization-Maintaining Optical Component |
| Type | Integrated Passive Fiber-Optic Device |
| Construction | Monolithic Hybrid Assembly |
| Operating Principle | Polarization-Selective Non-Reciprocal Isolation + Wavelength-Dependent Directional Coupling |
| [Key | Value] |
| Brand | AOE Tech |
| Origin | Shanghai, China |
| Model | PMIWDM |
| Component Type | Polarization-Maintaining Hybrid Optical Device |
| Signal Wavelength Range | 1530–1565 nm |
| Pump Wavelength Options | 960–990 nm (for 980 nm band) or 1460–1490 nm (for 1480 nm band) |
| Typical Peak Isolation | 40 dB (single-stage), 55 dB (dual-stage) |
| Isolation at 23 °C (Signal Path) | ≥30 dB (single-stage), ≥48 dB (dual-stage) |
| Insertion Loss (Signal Path, 23 °C) | ≤0.9 dB (single-stage, 1550/980), ≤1.2 dB (double-stage, 1550/1480) |
| Insertion Loss (Reflection Band) | ≤0.6 dB |
| Extinction Ratio | ≥22 dB (F-type, fast-axis blocked), ≥20 dB (B-type, both axes active) |
| Directivity | ≥55 dB |
| Return Loss | ≥50 dB |
| Thermal Stability of IL | ≤0.005 dB/°C |
| Max Optical Power Handling | 300 mW (CW) |
| Operating Temperature | −5 to +70 °C |
| Storage Temperature | −40 to +85 °C |
| Package Dimensions | Ø5.5 × L35 mm |
| Input/Output Fiber Options | PM1550 (transmit path), PM1550 / PM980 / HI1060 / SMF-28 (reflect path) |
| Alignment | Slow-axis aligned to connector key |
| Connector Options | FC/APC, FC/UPC, SC/APC, SC/UPC, LC/UPC, or bare fiber (250 µm or 900 µm) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Reference Photovoltaic Device |
| Model | QE-B1 |
| Calibration Traceability | NIST |
| Compliance | IEC 60904-2, WPVS Class A |
| Filter Options | Optional AM1.5G, AM0, or custom spectral filters |
| Output Type | Short-circuit current (Isc) calibrated under standard test conditions (STC) |
| Brand | Qlibri |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Optical Instrument Component |
| Model | Microcavity Platforms |
| Component Type | Tunable Fabry–Pérot Microcavity System |
| Finesse | F > 10⁵ |
| Quality Factor | Q > 10⁶ |
| Stability | < 10 pm (in closed-cycle cryostats) |
| Mode Volume | V < 2λ³ |
| Spectral Bandwidth | Δλ > 150 nm |
| Operating Temperature Range | < 10 K |
| Magnetic Field Compatibility | up to 150 mT (with optional Helmholtz coils) |
| Spectral Coverage | 350–2000 nm (VIS–NIR, mirror-swappable) |
| Room-Temperature Scan Range | 100 × 100 µm² |
| Cryogenic Scan Range | 10 × 10 µm² |
| Brand | Quantum Northwest |
|---|---|
| Origin | South Korea |
| Model | CD250 Cuvette Holder |
| Temperature Range | −10.00 to +105.00 °C (±0.02 °C accuracy) |
| Extended Range Option | −55.00 to +150.00 °C |
| Control Method | Peltier-based thermoelectric control |
| Temperature Monitoring | Integrated Pt100 or thermistor sensor |
| Sample Agitation | Magnetic stirring with adjustable speed |
| Optical Window | Stress-free fused silica |
| Compatibility | UV-Vis, Fluorescence, CD, Raman, NIR, Transient Absorption, Fiber-optic, Circular Dichroism, and Neutron Scattering spectrometers |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Brand | Quantum Northwest |
|---|---|
| Origin | South Korea |
| Model | FLASH300 Cuvette Holder |
| Temperature Range (Standard) | −40.00 to +110.00 °C |
| Temperature Range (Extended) | −50.00 to +150.00 °C |
| Temperature Accuracy | ±0.02 °C |
| Control Method | Peltier-based |
| Temperature Sensing | Integrated thermistor |
| Optical Ports | 4 side-mounted collinear ports |
| Vertical Adjustment | Micrometer-driven height alignment |
| Horizontal Translation | Micrometer-driven X-axis positioning |
| Sample Agitation | Adjustable-speed magnetic stirring |
| Optional Accessories | Thermal insulation shield, custom cuvette adapters, script-controlled temperature ramping |
| Brand | Quantum Northwest |
|---|---|
| Model | LC600 |
| Origin | South Korea |
| Type | Temperature-Controlled Optical Cuvette Holder |
| Temperature Range | −10.00 to +105.00 °C (±0.02 °C standard) |
| optional extended range | −55.00 to +150.00 °C |
| Control Method | Peltier-based thermoelectric control |
| Positioning | Motorized linear translation (6-position) |
| Sample Agitation | Adjustable-speed magnetic stirring per cuvette |
| Temperature Sensing | Integrated Pt100 or thermistor sensor |
| Compatibility | UV-Vis, fluorescence, CD, transient absorption, Raman, NIR, fiber-optic, and synchrotron-based spectroscopy platforms |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Brand | Quantum Northwest |
|---|---|
| Origin | South Korea |
| Model | qpod™ Cuvette Holder |
| Temperature Range | −40.0 °C to +105.0 °C (standard), extendable to −55.0 °C to +150.0 °C |
| Temperature Stability | ±0.02 °C (standard cuvette mode), ±0.05 °C (fiber-optic spectrometer mode) |
| Control Method | Peltier-based thermoelectric control with PID feedback |
| Temperature Sensor | Integrated Pt100 or thermistor probe |
| Stirring | Magnetic stirrer with variable speed |
| Optical Interface | SMA905 connector, fused silica focusing lens, UV-enhanced front-surface mirror, adjustable slit, optional 12.5 mm filter holder and polarizer |
| Configurations | CUV-qpod-ABSKIT (absorption/transmission), CUV-qpod-FLKIT (right-angle fluorescence), CUV-qpod-MPKIT (dual-mode absorption & fluorescence) |
| Compliance | Designed for GLP-compliant spectroscopic workflows |
| Brand | Quantum Northwest |
|---|---|
| Origin | South Korea |
| Model | T2 Single-Cell Cuvette Holder |
| Temperature Range | −10.00 to +105.00 °C (±0.02 °C) |
| Extended Range (custom) | −55.00 to +150.00 °C |
| Optical Ports | 2 |
| Control Method | Peltier-based |
| Stirring | Magnetic, speed-adjustable |
| Temperature Sensor | Integrated thermistor |
| Compliance | Designed for ASTM E289, ISO 13485-aligned manufacturing processes |
| Component Type | Optical Instrument Accessory |
| Brand | Quantum Northwest |
|---|---|
| Origin | South Korea |
| Model | t40 / TLC40 Single-Cell Optical Sample Holder |
| Temperature Range (t40) | −40.00 to +110.00 °C |
| Temperature Range (TLC40, standard) | −40.00 to +105.00 °C |
| Temperature Range (TLC40, extended) | −55.00 to +150.00 °C |
| Temperature Accuracy | ±0.01 °C (t40), ±0.02 °C (TLC40) |
| Brand | Quantum Northwest |
|---|---|
| Origin | South Korea |
| Model | TC120 (single-cell), TC225 (dual-cell), TC425 (quad-position turret) |
| Temperature Range | −10.00 to +105.00 °C (standard) |
| optional extended range | −55.00 to +150.00 °C |
| Temperature Stability | ±0.02 °C |
| Control Method | Peltier-based thermoelectric control with NIST-traceable thermistor sensing |
| Communication Interface | RS-232 serial command protocol |
| Sample Agitation | Integrated magnetic stirring |
| Compliance | NIST-traceable calibration, GLP-compliant temperature logging capability |
| Brand | Quantum Northwest |
|---|---|
| Origin | South Korea |
| Model | TLC400 Quad-Position Tower Sample Holder |
| Temperature Range | −25.00 to +105.00 °C (standard), extendable to −55.00 to +150.00 °C (custom) |
| Temperature Accuracy | ±0.02 °C |
| Brand | Quantum Northwest |
|---|---|
| Origin | South Korea |
| Model | TLC42 Dual-Cell Sample Holder |
| Temperature Range (Standard) | −40.00 to +105.00 °C |
| Temperature Range (Extended) | −55.00 to +150.00 °C |
| Temperature Accuracy | ±0.02 °C |
| Control Method | Peltier-based thermoelectric |
| Stirring | Magnetic, speed-adjustable per cell |
| Sensor | Integrated thermistor |
| Compliance | Designed for UV-Vis, fluorescence, CD, Raman, transient absorption, NIR, and fiber-optic spectroscopy platforms |
| Customization | Available for beam geometry, cell pathlength, optical access, and integration with specific spectrometers |
| Brand | Quantum Northwest |
|---|---|
| Origin | South Korea |
| Model | TLC50 Single-Cell Cuvette Holder |
| Temperature Range (Standard) | −40.00 to +105.00 °C |
| Temperature Range (Custom) | −55.00 to +150.00 °C |
| Temperature Accuracy | ±0.02 °C |