| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 2020wi |
| Price | USD 1,450 (FOB) |
| Product Type | Benchtop / Laboratory |
| Measurement Range | 0–4000 FNU |
| Resolution | 0.01 FNU (0.00–10.99), 0.1 FNU (11.00–109.9), 1 FNU (110–4000) |
| Operating Temperature | 0–50 °C |
| Accuracy | ±0.05 FNU (0–2.5 FNU), ±2% (2.5–100 FNU), ±3% (100–4000 FNU) |
| Detection Limit | 0.05 FNU |
| Repeatability | 0.02 FNU |
| Light Source | 860 nm LED (ISO 7027 compliant) |
| Signal Averaging Time | 0, 2, 5, or 10 s (user-selectable) |
| Data Storage | 4,000 points |
| Interface | USB and RS-232 |
| Display | Backlit LCD |
| Sample Volume | 10 mL |
| Cell Diameter | 25 mm |
| Enclosure Rating | IP67 |
| Dimensions (L×W×H) | 19.05 × 8.84 × 6.35 cm |
| Weight | 0.72 kg |
| Included Accessories | Calibration standards (0, 1, 10 FNU |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DC1200-PLR |
| Wavelength | 570 nm (Phosphate-specific) |
| Range | 0.00–6.00 mg/L PO₄-P |
| Resolution | 0.01 mg/L |
| Optical Accuracy | ±0.001 Absorbance Units |
| Response Time | 2 s |
| Light Source | LED |
| Detector | Silicon Photodiode |
| Cuvette Format | 25 mm round vials |
| Display | 3½-digit LCD with low-battery indicator |
| Enclosure | IP67-rated waterproof housing |
| Compliance | CE, EPA-compliant methods (e.g., EPA 365.3 for phosphate), RoHS |
| Power | 9 V alkaline battery or optional 220 V AC adapter (Model 1726-220) |
| Dimensions | 15 × 8 × 5.5 cm |
| Weight | 0.4 kg |
| Interface | RS232 (Cable Model 1772) |
| Standard Accessories | Sample vials, reagents, rugged carrying case |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | DC1500-UDV |
| Price | USD 1,420 (FOB US Port) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1901-CD |
| Product Type | Portable |
| Measurement Range | 0–4000 NTU (with extended low-range precision down to 0.05 NTU) |
| Resolution | 0.01 NTU (0.00–10.99), 0.1 NTU (11.00–109.9), 1 NTU (110–4000) |
| Operating Temperature | 0–50 °C |
| Accuracy | ±0.05 NTU (0–2.5 NTU), ±2% (2.5–100 NTU), ±3% (>100 NTU) |
| Detection Limit | 0.05 NTU/FNU |
| Repeatability | ±0.02 NTU or ±1% |
| Light Source | Tungsten lamp (525 nm), 428 nm LED, and 525 nm LED |
| Detector | Silicon photodiode |
| Sample Volume | 10 mL |
| Cell Diameter | 25 mm |
| Response Time | <2 s |
| Data Storage | 4000 measurements with timestamp |
| Interface | RS232 and USB |
| Power Supply | 100–240 V AC adapter |
| Dimensions (L×W×H) | 22 × 8 × 20 cm |
| Compliance | US EPA Method 180.1 & 330.5, ISO 7027, ASTM D6508 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1901-CD |
| Wavelengths | 428 nm, 525 nm, 568 nm, 635 nm |
| Wavelength Accuracy | ±2% FS |
| Bandwidth | 10 nm (typical) |
| Photometric Range | –2 to +2 AU |
| Photometric Precision | ±0.001 AU at 1.0 AU (low range), ±0.005 AU at 1.0 AU (high range) |
| Light Source | 4 high-stability LEDs |
| Detector | 4 silicon photodiodes with integrated interference filters |
| Display | 160 × 100 pixel backlit LCD (20 × 6 character line display) |
| Sample Cells | 25 mm round tubes, 10 mm square cuvettes, 16 mm COD vials |
| Data Storage | 500 time-stamped measurements |
| Interface | USB 2.0 |
| Power | Rechargeable 3.7 V Li-ion battery (~500 h typical operation) |
| Auto-off | Selectable (5, 10, 50 min or disabled) |
| Enclosure Rating | IP67 |
| Dimensions | 9 × 19 × 6.5 cm (L×W×H) |
| Weight | 0.4 kg |
| Compliance | CE, RoHS, FDA-compliant design for environmental and clinical water testing |
| Brand | Lamotte |
|---|---|
| Origin | USA |
| Model | Smart3 |
| Wavelengths | 428 nm, 525 nm, 568 nm, 635 nm |
| Optical Path | 10 mm cuvette / 25 mm round tube / 16 mm COD vial |
| Display | 160 × 100 backlit LCD (20 × 6 character graphic) |
| Photometric Range | –2 to +2 AU |
| Absorbance Accuracy | ±0.001 AU at 1.0 AU |
| Wavelength Accuracy | ±2% FS |
| Bandwidth | 10 nm |
| Light Source | Four high-stability LEDs with integrated narrow-band interference filters |
| Detector | Silicon photodiode |
| Data Storage | 500 measurements |
| User-Defined Methods | Up to 25 custom calibration curves |
| Language Options | English, Spanish, French, Portuguese, Italian, Chinese, Japanese |
| IP Rating | IP67 |
| Power | Rechargeable Li-ion battery, USB bus power, or AC adapter |
| Auto-off | Configurable (5 / 10 / 50 min) |
| Dimensions | 8.84 × 19.05 × 6.35 cm |
| Weight | 362 g |
| Compliance | CE-marked |
| Brand | LAND |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | VIRALERT 3 |
| Price | Upon Request |
| Spectral Response | 7.5–13.5 µm (typical uncooled microbolometer range) |
| Detector Type | Uncooled VOx Microbolometer |
| Measurement Principle | Non-contact infrared radiometry |
| Operating Mode | Ambient-temperature-stabilized thermal imaging |
| Frame Rate | <9 Hz |
| Temperature Accuracy | ±0.5 °C at 1 m distance (±0.9 °F) |
| Temperature Range | 10 °C to 50 °C (ambient operating), 30 °C to 45 °C (human skin temperature measurement range) |
| Thermal Resolution (NETD) | <0.12 °C |
| IR Image Resolution | 1280 × 960 pixels |
| Visual Camera Resolution | 1280 × 960 @ 12 fps (CMOS color sensor) |
| Field of View | 39° × 31° |
| Reference Source | Integrated fixed-point blackbody at 38.0 °C ± 0.2 °C |
| Power Supply | 5 V DC via USB (blackbody), system powered via PC USB or external 12 V DC adapter |
| Compliance | CE, UKCA, RoHS, ISO/IEC 17025 traceable calibration support |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | LJ350UV |
| Price | USD 1,390 (FOB Qingdao) |
| Wavelength Range | 200–400 nm (UV-C to UV-A) |
| Spectral Bandwidth (FWHM) | 2 nm |
| Optical Resolution | 0.2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Detector | High-precision CCD array |
| Input Aperture | Ø10 mm |
| Display | 5.0" IPS capacitive touchscreen |
| Operating System | Embedded Linux |
| Battery | 4000 mAh Li-ion, 10 h continuous operation |
| Data Storage | 4 GB microSD (≥60,000 records) |
| Interface | USB Type-C (≥1 A current rating) |
| Illuminance Accuracy | Class I (±4% reading ±1 digit) |
| Chromaticity Repeatability | ±0.0005 in CIE 1931 (x,y) |
| CCT Range | 1,000–100,000 K |
| Stray Light | ≤0.3% |
| Operating Temp. | −10 to +40 °C, RH <70% (non-condensing) |
| Storage Temp. | −20 to +45 °C, RH <70% (non-condensing) |
| Dimensions | 146 × 81 × 22.8 mm |
| Weight | ~300 g (body only, with battery) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | USS |
| Component Type | Fiber Collimator |
| Light Source Options | Xenon + Tungsten-Halogen (UV–NIR), LED, or Laser |
| Spectral Range | 250 nm to 2500 nm |
| Color Temperature Range | 2800 K to 6500 K (continuously variable) |
| Radiance Adjustment | Fully continuous, 0–100% output |
| Calibration | NIST-traceable radiometric and photometric reports available |
| Software Control | LabVIEW- and Python-compatible GUI with automated ramping, logging, and audit trail support |
| Compliance | Designed to support ISO/IEC 17025-compliant calibration workflows |
| Brand | LARGEBEAM |
|---|---|
| Origin | USA |
| Manufacturer Type | OEM Manufacturer |
| Import Status | Imported |
| Model | RIIDEye |
| Pricing | Upon Request |
| Detector Type | 2×2 NaI(Tl) scintillator & 1.5×1.5″ LaBr₃(Ce) crystal |
| Energy Range | 20 keV – 3 MeV |
| Display | 3.5″ TFT-LCD, 320×240 resolution, 32,000-color backlight |
| Battery Life | 8 hours (rechargeable Li-ion), with 6 spare AA battery slots |
| Weight | 2.6 kg (5.7 lb) with NaI configuration |
| Dimensions | 27.9 × 12.0 × 21.9 cm (11.0 × 4.7 × 8.6 in) |
| Operating Temperature | −20 °C to +50 °C (−4 °F to 122 °F) |
| Neutron Detection | 1.8 × 3.4 cm Ce-doped Cs₂LiYCl₆ (CLYC) crystal |
| Isotope Library | 47 nuclides |
| Trigger Modes | ANSI, ANSI+, Security, Medical, Industrial, User-Defined |
| Stabilization | Automatic K-40 background compensation, no external reference source required |
| Brand | Laser Components |
|---|---|
| Model | COUNT BLUE |
| Spectral Range | 350–1000 nm |
| Peak Detection Efficiency | 55% @ 405 nm, 70% @ 532 nm, 55% @ 670 nm |
| Active Area | 100 µm diameter |
| Dark Count Rate | 10–250 counts/s (configurable per bias) |
| Timing Resolution | 1000 ps FWHM |
| Dead Time | 42–45 ns |
| Afterpulsing Probability | ≤0.2% |
| Gating Input | TTL-compatible (0–0.5 V = disabled, ≥2.4 V = enabled) |
| Gating Response Time | ≤20 ns (on), ≤65 ns (off) |
| TTL Output Pulse Width | 15–17 ns |
| TTL Output Amplitude (50 Ω) | 3 V |
| Supply Voltage | 11.5–12.5 V DC |
| Supply Current | ≤0.8 A |
| Maximum Count Rate | 20 Mcps |
| Connector Options | SMA (standard), FC (optional) |
| Brand | Laser Components |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model Series | PB2X |
| Component Category | Infrared Photodetector |
| Spectral Range | 1–3 µm (20% cutoff at 3.3 µm) |
| Available Cooling Options | Uncooled (PB25), Single-Stage TE-Cooled (PB27), Dual-Stage TE-Cooled (PB30) |
| Active Area Options | 1×1 mm² to 6×6 mm² |
| Typical Chip Size | 2×2 mm² (customizable) |
| Brand | FLC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 1 |
| Core Construction | Solid-State Laser Device |
| Wavelength Range | 375–3100 nm |
| Output Power | 1–500 mW |
| Packaging Options | TO-can, Butterfly, C-mount, Coaxial, Fiber-Pigtailed |
| Optional Integrations | Thermoelectric (TE) Coolers, Monitor Photodiodes, FC/PC or SMA Fiber Coupling Interfaces |
| Brand | Rainbow Photonics |
|---|---|
| Origin | Switzerland |
| Model | newopto |
| Wavelengths | 405 nm (blue), 532 nm (green) |
| Output Power | 1 mW / 3 mW (532 nm), 12 mW (405 nm) |
| Distribution Type | Authorized Import Distributor |
| Compliance | CE, RoHS, FDA 21 CFR Part 1040.10 (Class 3R / Class 3B per configuration) |
| Brand | Laser Quantum |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Finesse |
| Type | Diode-Pumped Solid-State (DPSS) Single-Frequency Laser |
| Wavelength | 532 nm |
| Output Power | 4–16 W |
| Beam Diameter | 2.25 ± 0.25 mm |
| Spatial Mode | TEM₀₀ |
| Beam Ellipticity | < 1:1.15 |
| Spectral Bandwidth | < 50 GHz |
| Beam Divergence | < 0.4 mrad |
| M² Factor | < 1.1 |
| Power Stability | < 0.1% RMS (<10 W), < 0.05% RMS (≥10 W) |
| Beam Pointing Stability | < 2 μrad/°C RMS |
| Intensity Noise | < 0.1% (10 Hz–100 MHz), < 0.03% (<10 W), < 0.02% (≥10 W) |
| Polarization Ratio | > 100:1 (horizontal) |
| Coherence Length | ~6 mm |
| Beam Angular Deviation | < 1 mrad |
| Operating Temperature | 20–40 °C |
| Warm-up Time | 10 min |
| CEP Control | f-2f interferometer-based feedback loop |
| Optional Fiber Delivery | Yes |
| Warranty | 5 years / 15,000 operating hours (for research institutions) |
| Brand | Laser Quantum |
|---|---|
| Origin | France |
| Model | gecco Series |
| Output Power | 600 mW (avg.) |
| Pulse Duration | <20 fs (gecco one) / <15 fs (gecco ultra) |
| Repetition Rate | 84 MHz or 100 MHz (selectable) |
| Central Wavelength | 800 ± 20 nm |
| Spectral Bandwidth (FWHM) | >45 nm (gecco one) / >50 nm (gecco ultra) |
| Pulse Energy | 7.0 nJ @ 84 MHz / 6.0 nJ @ 100 MHz |
| Beam Diameter (FWHM) | 1.2 ± 0.2 mm @ 25°C |
| Beam Quality | TEM₀₀ |
| Beam Divergence | <2 mrad |
| Power Stability | <0.2% RMS |
| Polarization Ratio | >100:1 (horizontal) |
| Warm-up Time | 20 min |
| Operating Temperature | 21 ± 5°C |
| Brand | Laser Quantum |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Type | Imported OEM Solid-State Laser System |
| Model | Gem473 / Gem532 / Gem561 / Gem660 / Gem671 |
| Wavelengths | 473 nm, 532 nm, 561 nm, 660 nm, 671 nm |
| Output Power Range | 50 mW to 2 W (model-dependent) |
| Beam Diameter | 0.75–1.0 mm ± tolerance |
| Spatial Mode | TEM₀₀ |
| Power Stability | ≤ 1.0% RMS |
| Beam Pointing Stability | < 10 µrad/°C |
| Noise Level | 0.6–1.5% (10 Hz–10 kHz) |
| Polarization Ratio | >100:1, Vertical |
| Coherence Length | ~7.5 mm (473/561 nm), ~25 µm (532/660/671 nm) |
| Spectral Bandwidth | 30–40 GHz |
| Divergence | < 0.8–1.5 mrad |
| Warm-up Time | 10–15 min |
| Operating Temperature | 15–40 °C |
| Brand | Laser Quantum |
|---|---|
| Origin | United Kingdom |
| Model | GigaJet Series |
| Type | Solid-State Femtosecond Oscillator |
| Repetition Rate | 500 MHz or 1 GHz |
| Central Wavelength | 800 ± 20 nm (GigaJet & GigaJet Ultra), 750–850 nm tunable (GigaJet Tune) |
| Pulse Duration | ≤30 fs (GigaJet), ≤50 fs (GigaJet Tune), ≤15 fs (GigaJet Ultra) |
| Average Power | 0.8–1.8 W (GigaJet), 0.7–1.4 W (GigaJet Tune), 0.75–1.5 W (GigaJet Ultra) |
| Pulse Energy | 0.8–3.6 nJ (GigaJet), 0.7–1.4 nJ (GigaJet Tune), 0.75–1.5 nJ (GigaJet Ultra) |
| Beam Diameter (FWHM) | 0.8 ± 0.3 mm |
| Spatial Mode | Near TEM₀₀ |
| Beam Divergence | 2.0 ± 0.5 mrad |
| Polarization Ratio | >100:1, horizontal |
| Pump Requirement | 5 W, 532 nm, TEM₀₀, vertically polarized |
| Operating Temperature | 21 ± 5 °C |
| Brand | Laser Quantum |
|---|---|
| Origin | United Kingdom |
| Model | Gigajet Twin Series |
| Repetition Rate | 333 MHz / 500 MHz / 1 GHz (selectable) |
| Average Output Power | 0.7–1.8 W (model-dependent) |
| Central Wavelength | 800 ± 20 nm (standard) / 750–850 nm (tunable, Gigajet Twin C) |
| Pulse Duration | ≤15–50 fs (model-dependent) |
| Beam Quality (M²) | ≤1.2 (sagittal), ≤1.6 (tangential, Gigajet Twin C) |
| Long-Term Repetition Rate Stability | ±500 Hz per oscillator |
| Synchronization Mode | Active phase-locked or fixed frequency offset operation |
| Pump Requirement | 5 W, 532 nm, TEM₀₀, vertically polarized, CW |
| Brand | Laser Quantum |
|---|---|
| Origin | United Kingdom |
| Model | Opus532 / Opus660 / Opus1064 |
| Type | Solid-State Continuous-Wave (CW) Lasers |
| Wavelength | 532 nm / 660 nm / 1064 nm |
| Output Power | 2–6 W / 1–1.5 W / 4–10 W |
| Beam Diameter | 1.85±0.2 mm / 0.85±0.2 mm / 1.85±0.2 mm |
| Spatial Mode | TEM₀₀ |
| Beam Ellipticity | <1_1.15 / <1_1.2 / — |
| Spectral Bandwidth | 45 GHz / 30 GHz / 80 GHz |
| Beam Divergence | <0.4 mrad / <1.5 mrad / <0.6 mrad |
| M² Factor | <1.1 / <1.2 / <1.5 |
| Power Stability (RMS) | <0.2% / <1.0% / <0.2% |
| Pointing Stability | <2 μrad/°C / <10 μrad/°C / <10 μrad/°C |
| Intensity Noise (RMS, 10 Hz–100 MHz / 10 Hz–50 kHz / 10 Hz–1 MHz) | ≤0.08% / ≤0.6% / ≤0.15% |
| Polarization Ratio | >100:1 |
| Polarization Orientation | Vertical |
| Beam Angle | ≤1 mrad |
| Operating Temperature | 15–40 °C |
| Warm-up Time | 10 minutes |
| Brand | Laser Quantum |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model Series | Taccor |
| Core Component | Diode-Pumped Solid-State Ti:Sapphire Oscillator (not free-electron laser — correction applied per technical accuracy) |
| Average Power Range | 0.7–1.8 W |
| Repetition Rate | 1 GHz or 10 GHz (model-dependent) |
| Central Wavelength | 740–930 nm (tunable) or fixed at 800 ± 20 nm |
| Pulse Duration | <15 fs to <80 fs |
| Beam Quality | M² < 1.6 (typical), TEM₀₀-like spatial profile |
| Power Stability | ±1.0% RMS over 24 h |
| Amplitude Noise | <0.1% RMS (10 Hz–10 MHz) |
| Polarization Ratio | >100:1 (horizontal) |
| Operating Temperature | 21 ± 5 °C |
| Integrated Pump Source | Finesse ultra-low-noise diode-pumped Nd:YVO₄ laser |
| Brand | Laser Quantum |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Tau Series |
| Core Technology | Monolithic Solid-State CW Laser |
| Wavelength Options | 532 nm / 671 nm |
| Output Power | 30–150 mW (532 nm), 30–50 mW (671 nm) |
| Beam Diameter | 1.0 ± 0.2 mm (532 nm), 1.4 ± 0.2 mm (671 nm) |
| Spatial Mode | TEM₀₀ |
| Beam Divergence | < 1.0 mrad |
| Ellipticity | < 1:1.2 |
| Spectral Bandwidth | ~100 GHz |
| Coherence Length | ~3 mm |
| Polarization Ratio | >100:1, Vertical |
| Power Stability | < 1.0% RMS |
| Beam Pointing Stability | < 10 µrad/°C |
| Intensity Noise | ≤ 0.5% (532 nm), ≤ 1.0% (671 nm), 0.1–10 kHz |
| Operating Temperature | 22–37 °C |
| Warm-up Time | < 10 min |
| Environmental Robustness | 1200 g shock-rated, hermetically sealed housing |
| Control Interface | RS232 |
| Remote Monitoring | Supported via network-enabled diagnostics and parameter optimization |
| Fiber Coupling Options | Single-mode and multimode fiber output configurations |
| Brand | Laser Quantum |
|---|---|
| Origin | United Kingdom |
| Model | Torus532 / Torus660 |
| Wavelength | 532 nm / 660 nm |
| Output Power | 50–750 mW (Torus532) / 50–200 mW (Torus660) |
| Beam Diameter | 1.7 mm ± 0.2 mm |
| Spatial Mode | TEM₀₀ |
| Beam Ellipticity | <1_1.1 |
| Spectral Linewidth | <1 MHz |
| Beam Divergence | ≤0.4 mrad |
| M² Factor | <1.1 |
| Power Stability | <1.0% RMS |
| Intensity Noise | <0.25% RMS (Torus532) / <0.5% RMS (Torus660), measured over 10 Hz–100 MHz |
| Polarization Ratio | >100:1 |
| Polarization Orientation | Vertical |
| Coherence Length | >100 m |
| Beam Pointing Stability | 1 mrad |
| Operating Temperature | 15–35 °C |
| Warm-up Time | 30 minutes |
| Brand | Laser Quantum |
|---|---|
| Origin | United Kingdom |
| Model | Ventus |
| Wavelength Options | 473 nm, 532 nm, 561 nm, 660 nm, 671 nm, and Ventus Solo (532 nm) |
| Output Power Range | 50 mW to 1.5 W |
| Beam Diameter | 1.5 mm ± 0.1 mm |
| Spatial Mode | TEM₀₀ |
| Beam Ellipticity | < 1:1.2 |
| Spectral Bandwidth | < 10 GHz to < 40 GHz (model-dependent) |
| Beam Divergence | < 0.6 mrad (typ.) |
| M² Factor | < 1.2 (typ.) |
| Power Stability | < 0.4 % RMS (typ.) |
| Beam Pointing Stability | < 10 µrad/°C |
| Intensity Noise | < 0.15 % RMS (1 Hz–100 MHz) |
| Polarization Ratio | > 100:1 (vertical) |
| Coherence Length | ~7.5 mm to ~75 mm (model-dependent) |
| Operating Temperature | 15 °C to 40 °C |
| Warm-up Time | ≤ 10 min |
| Brand | Laser Quantum |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model Series | VETEON |
| Core Technology | Diode-Pumped Solid-State (DPSS) Femtosecond Oscillator |
| Key Configuration | Integrated Pump Laser, Monolithic Cavity Design, CEP-Stabilizable Architecture |
| Output Wavelength | 800 ± 20 nm |
| Average Power Range | 220–600 mW |
| Pulse Duration (measured) | <5.5–8 fs |
| Spectral Bandwidth (FWHM) | 100–400 nm |
| Repetition Rate | 80 MHz |
| RMS Intensity Noise | <0.08–0.2% |
| Beam Quality (M²) | <1.2 |
| Long-Term Energy Stability (24 h) | <1% |
| Cooling | Conductive/Water-Cooled Baseplate |
| Brand | Laser-Export |
|---|---|
| Origin | Russia |
| Model | DTL Series |
| Wavelengths | 263 nm, 351 nm, 527 nm, 1053 nm |
| Output Modes | Q-switched pulsed |
| Repetition Rate | 0.01–100 kHz (adjustable) |
| Pulse Width | <5 ns to <170 ns (dependent on wavelength & repetition rate) |
| Average Power | >16 mW to >700 mW |
| Peak Power | >2 kW to >250 kW |
| Beam Mode | TEM₀₀ |
| Beam Diameter | 1.05–2.0 mm |
| Beam Divergence | 0.55–4.0 mrad |
| Polarization Ratio | >50:1 or >100:1 (vertical/horizontal) |
| Operating Temperature | 15–35 °C, RH <80% |
| Interface | RS-232 |
| Key | Wavelength: 355 nm |
|---|---|
| Repetition Rate (External Trigger Mode) | 200–2000 Hz (200 Hz nominal) |
| Pulse Energy | 20 ±10% mJ @ 200 Hz |
| Pulse Width | 5 ±2 ns (≤7 ns and ≥3 ns @ 200 Hz) |
| Beam Divergence | 3.4 ±0.5 mrad |
| Operating Temperature | 15–35 °C (RH <80%) |
| Manufacturer Origin | Russia |
| Compliance | CE, RoHS, IEC 60825-1:2014 Class 4 Laser Product |
| Brand | Laser-Export |
|---|---|
| Origin | Russia |
| Model | TECH Series |
| Wavelength Options | 263 nm, 351 nm, 527 nm, 1053 nm |
| Operating Mode | Q-Switched, Internal/External Triggering |
| Pulse Energy Range | 25–1000 µJ (up to 3000 mJ in high-energy variants) |
| Pulse Width (FWHM) | 4–15 ns |
| Peak Power | 6–250 kW |
| Repetition Rate | 0–4 kHz |
| Beam Quality | TEM₀₀, M² < 1.28 |
| Energy Stability (8 h) | < 2% RMS |
| Laser Head Weight | < 1.5 kg |
| Power Supply Weight | < 2 kg |
| Cooling | Conductive (No Water Cooling Required) |
| Compliance | CE, RoHS, IEC 60825-1:2014 Class 4 Laser Product |
| Brand | LaserPoint |
|---|---|
| Origin | Italy |
| Model | Cronos / Fit |
| Power Range (Cronos) | 1.5 W – 10 kW |
| Power Range (Fit) | 0.5 W – 500 W |
| Measurement Principle | Thermopile-based real-time thermal dynamics analysis |
| Display | Integrated LCD showing power, wavelength setting (CO₂, Nd:YAG, Diode), battery status |
| Measurement Time | 10 s (Cronos), 4 s (Fit) |
| Accuracy | ±4% (Cronos), ±3% (Fit) |
| Repeatability | ±2% (Cronos), ±1% (Fit) |
| Calibration | User-performable via built-in calibration routine |
| Operating Wavelengths | 10.6 µm (CO₂), 1.064 µm (Nd:YAG), 0.4–1.1 µm (Diode) |
| Resolution | Full-scale dependent (e.g., 1 W at 10 kW range) |
| Power Supply | Internal rechargeable battery |
| Compliance | CE, RoHS, ISO/IEC 17025 traceable calibration support |