Optical Instruments
Filter
Showing 6571–6600 of 7810 results
| Brand | TESCAN |
|---|---|
| Origin | Czech Republic |
| Model | VEGA |
| Instrument Type | Floor-standing SEM |
| Electron Source | Tungsten Filament |
| Secondary Electron Resolution | 3.0 nm @ 30 kV |
| Magnification Range | 2× – 1,000,000× |
| Acceleration Voltage | 200 V – 30 kV (continuously adjustable) |
| Backscattered Electron Resolution | 3.5 nm @ 30 kV |
| Brand | TESCAN |
|---|---|
| Origin | Czech Republic |
| Model | TESCAN VEGA |
| Instrument Type | Floor-standing Conventional SEM |
| Electron Source | Tungsten Filament |
| Secondary Electron Resolution | 3.0 nm @ 30 kV |
| Magnification Range | 2× – 1,000,000× |
| Accelerating Voltage | 200 V – 30 kV (continuously adjustable) |
| Backscattered Electron Resolution | 3.5 nm @ 30 kV |
| Brand | TESCAN |
|---|---|
| Origin | Czech Republic |
| Model | TESCAN-VEGA |
| Instrument Type | Floor-standing Conventional SEM |
| Electron Source | Tungsten Filament |
| Secondary Electron Resolution | 3.0 nm @ 30 kV |
| Magnification Range | 2× to 1,000,000× |
| Accelerating Voltage | 200 V – 30 kV (continuously adjustable) |
| Backscattered Electron Resolution | 3.5 nm @ 30 kV |
| Brand | TESCAN |
|---|---|
| Origin | Czech Republic |
| Manufacturer | TESCAN ORSAY HOLDING a.s. |
| Type | VEGA |
| Electron Source | Tungsten (W) Filament |
| Secondary Electron Resolution | 3.0 nm @ 30 kV |
| Magnification Range | 2× to 1,000,000× |
| Accelerating Voltage | 0.2–30 kV (continuously adjustable) |
| Backscattered Electron Resolution | 3.5 nm @ 30 kV |
| Brand | TESCAN |
|---|---|
| Origin | Czech Republic |
| Model | TESCAN VEGA |
| Instrument Type | Floor-standing SEM |
| Electron Source | Tungsten Filament |
| Resolution (Secondary Electrons) | 3.0 nm @ 30 kV |
| Resolution (Backscattered Electrons) | 3.5 nm @ 30 kV |
| Magnification Range | 2× to 1,000,000× |
| Accelerating Voltage | 0.2–30 kV (continuously adjustable) |
| Software Platform | TESCAN Essence™ |
| Vacuum Mode | SingleVac™ (standard) |
| Optical Design | Wide Field Optics™ |
| Beam Control | In-Flight Beam Tracing™ |
| Safety System | Essence™ 3D Collision Prevention Module |
| Energy Efficiency | Vacuum Buffer Unit |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic (China) |
| Model | Testo 540 |
| Pricing | Available Upon Request |
| Sensor | Phototransistor |
| Measurement Range | 0–99,999 lux |
| Resolution | 1 lux (0–19,999 lux) |
| Accuracy | ±3% of reading (vs. traceable reference standard) |
| Sampling Rate | 0.5 s per measurement |
| Units | lux, foot-candles (fc) |
| Operating Temperature | 0–+50 °C |
| Power Supply | Two AAA alkaline batteries |
| Battery Life | Up to 200 hours (with backlight disabled, typical usage) |
| Ingress Protection | IP10 |
| Dimensions | 133 × 46 × 25 mm |
| Weight | 95 g |
| Brand | testo |
|---|---|
| Model | testo 545 |
| Sensor Type | Silicon Photodiode |
| Measurement Range | 0–100,000 lx |
| Accuracy | ±3% of reading ±1 digit (Class C per DIN 5032-7 / EN 13032-1 Annex B) |
| Resolution | 0.1 lx (<10,000 lx), 1 lx (≥10,000 lx) |
| Operating Temperature | −10 to +50 °C (probe: 0 to +50 °C) |
| IP Rating | IP40 (instrument), IP20 (probe) |
| Battery Life | ~70 h (3 × AA) |
| Weight | 288 g |
| Probe Dimensions | 134 × 54 × 23 mm |
| Main Unit Dimensions | 149 × 60 × 28 mm |
| Cable Length | 1.4 m |
| Compliance | V(λ)-corrected photopic response per CIE 1931 standard, optimized for white and warm-white LEDs (CCT < 5000 K), excluding monochromatic blue LEDs |
| Brand | testo |
|---|---|
| Model | testo 545 |
| Measurement Range | 0.01 to 200,000 lx (typical) |
| Spectral Response | V(λ)-corrected per CIE 1931 standard |
| Accuracy | ±3% ±1 digit (at 25°C, 500 lx, tungsten reference) |
| Operating Temperature | 0 to +50°C |
| Battery | 3 × AA (included) |
| Connectivity | Bluetooth 4.2 LE |
| App Compatibility | testo Smart App (iOS/Android) |
| Compliance | EN 13032-1, DIN 5032-7, ISO/CIE 19476 |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | testo 865 |
| Price | Upon Request |
| Spectral Response | Mid-Wave Infrared (MWIR) |
| Detector Type | Scanning Focal Plane Array (FPA) |
| Application | Temperature Measurement |
| Measurement Method | Non-Contact |
| Detector Cooling | Uncooled |
| Frame Rate | 9 Hz @ 160 × 120 |
| Accuracy | ±2 °C or ±2% of reading (whichever is greater) |
| Temperature Range | −20 °C to +280 °C |
| Infrared Resolution | 160 × 120 pixels |
| Spectral Band | 7.5–14 µm |
| Thermal Sensitivity (NETD) | < 0.12 °C |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 865 |
| Detector Type | Scanning Focal Plane Array |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 160 × 120 pixels |
| Enhanced Resolution (via IR SuperResolution) | 320 × 240 pixels |
| Thermal Sensitivity (NETD) | < 0.12 °C |
| Temperature Range | –20 to +280 °C |
| Accuracy | ±2 °C or ±2% of reading |
| Measurement Method | Non-contact infrared radiometry |
| Frame Rate | 9 Hz @ 160 × 120 |
| Operating Mode | Uncooled microbolometer |
| Wavelength Band | Mid-wave infrared (MWIR) |
| Total Measurement Points | 19,200 per frame |
| Image Export Format | JPEG |
| Software Included | testo IRSoft |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8650 |
| Detector Type | Uncooled Microbolometer FPA (Scanning-type not applicable — corrected per technical reality) |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 160 × 120 pixels |
| SuperResolution (testo Ultra-Pixel) | 320 × 240 pixels |
| Thermal Sensitivity (NETD) | ≤0.12 °C |
| Frame Rate | 9 Hz |
| Temperature Range | −20 °C to +280 °C |
| Accuracy | ±2 °C or ±2 % of reading (whichever is greater) |
| IFOV | 3.4 mrad |
| Spatial Resolution (Ultra-Pixel mode) | 2.1 mrad |
| Field of View | 31° × 23° |
| Minimum Focus Distance | <0.5 m |
| Display | 3.5″ LCD, 320 × 240 px |
| Storage | 2.8 GB internal memory |
| Image Formats | .bmt, .jpg, .bmp, .png, .xls, .csv |
| Video Output | USB 2.0 Micro-B streaming |
| Operating Temp. | −15 °C to +50 °C |
| Storage Temp. | −30 °C to +60 °C |
| Humidity | 20–80 % RH (non-condensing) |
| IP Rating | IP54 |
| Dimensions | 219 × 96 × 95 mm |
| Weight | 510 g |
| Battery Life | ~4 h (Li-ion, rechargeable) |
| Power Supply | AC adapter included |
| Emission Adjustment | 0.01–1.00 (user-selectable) |
| Software | testo IRSoft (Windows 10/8/7, free download) |
| Compliance | EMC Directive 2014/30/EU, RoHS, CE |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8650 |
| Detector Type | Uncooled Microbolometer |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 160 × 120 pixels (enhanced to 320 × 240 via testo SuperResolution) |
| Thermal Sensitivity (NETD) | ≤0.12 °C |
| Temperature Range | −20 to +280 °C |
| Accuracy | ±2 °C or ±2 % of reading (whichever is greater) |
| Frame Rate | 9 Hz |
| Field of View | 31° × 23° |
| IFOV | 3.4 mrad (standard), 2.1 mrad (SuperResolution) |
| Minimum Focus Distance | <0.5 m |
| Display | 3.5″ LCD, 320 × 240 pixels |
| Operating Temperature | −15 to +50 °C |
| Storage Temperature | −30 to +60 °C |
| Humidity | 20–80 % RH (non-condensing) |
| IP Rating | IP54 |
| Dimensions | 219 × 96 × 95 mm |
| Weight | 510 g |
| Battery Life | ~4 h |
| Interface | USB 2.0 Micro-B |
| Image Formats | .bmt, .jpg, .bmp, .png, .xls, .csv |
| Internal Memory | 2.8 GB |
| Software | testo IRSoft (Windows 10/8/7) |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8681 |
| Detector Type | Uncooled Microbolometer FPA (Scanning-Type) |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 160 × 120 pixels |
| SuperResolution (via testo SuperPixel) | 320 × 240 pixels |
| Thermal Sensitivity (NETD) | ≤ 0.10 °C |
| Field of View (FOV) | 31° × 23° |
| Instantaneous Field of View (IFOV) | 3.4 mrad (standard lens) |
| Frame Rate | 9 Hz |
| Temperature Range | −30 to +100 °C |
| Accuracy | ±2 °C or ±2 % of reading (whichever is greater) |
| Emissivity Adjustment | 0.01–1.00 (with ε-Assist automatic calibration) |
| Reflected Apparent Temperature Compensation | Yes (RTC-assisted) |
| Focus | Fixed-focus optimized for ≥0.5 m |
| Visible Light Camera | ≥3.1 MP, co-registered with IR |
| Display | 3.5″ LCD, 320 × 240 px |
| Storage | Internal 2.8 GB |
| Battery Life | Up to 4 h (rechargeable Li-ion) |
| Environmental Rating | IP54 |
| Operating Temperature | −15 to +50 °C |
| Weight | 510 g |
| Dimensions | 219 × 96 × 95 mm |
| Compliance | EMC Directive 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8690 11 |
| Detector Type | Scanning Focal Plane Array |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 160 × 120 pixels |
| Thermal Sensitivity (NETD) | < 0.12 °C @ 30 °C |
| Frame Rate | 9 Hz |
| Temperature Range | −20 to +280 °C |
| Accuracy | ±3 °C or ±3 % of reading (whichever is greater) |
| Field of View | 34° × 26° |
| Minimum Focus Distance | < 0.5 m (fixed focus) |
| IFOV | 3.68 mrad |
| Display | 3.5" LCD, 320 × 240 pixels |
| Operating Temperature | −15 to +50 °C |
| Storage Temperature | −30 to +60 °C |
| Humidity Range | 20–80 % RH (non-condensing) |
| IP Rating | IP54 |
| Dimensions | 219 × 96 × 95 mm |
| Weight | 550 g |
| Battery Life | 4.0 h |
| Internal Memory | 1.6 GB (>2000 images without SuperResolution) |
| Image Formats | .bmt, .jpg, .bmp, .png, .csv, .xls |
| Software Compatibility | Windows XP SP3 through Windows 10, USB 2.0 interface |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | testo 869 |
| Thermal Resolution | 160 × 120 pixels |
| IR Pixel Count | 19,200 |
| Spectral Range | 7.5–14 µm |
| Thermal Sensitivity (NETD) | < 0.12 °C |
| Temperature Range | −20 to +280 °C |
| Accuracy | ±2 °C or ±2% of reading |
| Frame Rate | 9 Hz @ 160 × 120 |
| Measurement Principle | Non-contact infrared radiometry |
| Detector Type | Uncooled microbolometer |
| Operating Mode | Handheld, battery-powered |
| Image Format | JPEG |
| Software Included | testo IRSoft |
| Power Supply | Rechargeable Li-ion battery + AC adapter |
| Connectivity | USB 2.0 |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 869 |
| Thermal Resolution | 160 × 120 pixels |
| Image Resolution | 19,200 IR pixels |
| Spectral Range | 7.5–14 µm |
| NETD | < 0.12 °C |
| Temperature Range | −20 to +280 °C |
| Accuracy | ±2 °C or ±2% of reading |
| Frame Rate | 9 Hz @ 160 × 120 |
| Measurement Principle | Non-contact infrared radiometry |
| Detector Type | Uncooled microbolometer |
| Operating Mode | Handheld, battery-powered |
| Thermal Sensitivity Mode | Auto hot/cold spot tracking |
| Data Export Format | JPEG |
| Software Included | testo IRSoft (PC-based analysis suite) |
| Power Supply | Rechargeable Li-ion battery + AC adapter |
| Interface | USB 2.0 |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8712 |
| Detector Type | Scanning Focal Plane Array |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 240 × 180 pixels |
| SuperResolution (via testo PixelBoost) | 480 × 360 pixels |
| Thermal Sensitivity (NETD) | ≤ 0.09 °C |
| Field of View | 35° × 26° |
| IFOV | 2.6 mrad (standard), 1.6 mrad (with PixelBoost) |
| Frame Rate | 9 Hz |
| Focus | Fixed-focus lens (min. distance < 0.5 m) |
| Temperature Range | −30 to +100 °C |
| Accuracy | ±2 °C or ±2 % of reading (whichever is greater) |
| Emissivity Adjustment | 0.01–1.00, with ε-Assist automatic calibration |
| Reflective Temperature Compensation | RTC-assisted |
| Measurement Modes | Hot/Cold Spot Detection, ΔT, Area Avg, Solar Mode |
| Image Output | IR + visible-light overlay (≥3.1 MP digital camera) |
| Display | 3.5″ LCD, 320 × 240 px |
| Storage | Internal 2.8 GB (BMT, JPEG, PNG, BMP, CSV, XLS) |
| Connectivity | Bluetooth 4.2 + Wi-Fi (IEEE 802.11 b/g/n), USB 2.0 Micro-B |
| Environmental Rating | IP54 |
| Operating Temp. | −15 to +50 °C |
| Battery Life | Up to 4 h (rechargeable Li-ion) |
| Compliance | RED Directive 2014/53/EU, EMC Directive 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8722 |
| Detector Type | Uncooled Microbolometer Focal Plane Array (FPA) |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 320 × 240 pixels (SuperResolution up to 640 × 480 pixels) |
| Thermal Sensitivity (NETD) | ≤ 0.06 °C |
| Frame Rate | 9 Hz |
| Temperature Range | −30 to +100 °C |
| Accuracy | ±2 °C or ±2 % of reading |
| Measurement Method | Non-contact infrared radiometry |
| Operating Temperature | −15 to +50 °C |
| Storage Temperature | −30 to +60 °C |
| Relative Humidity | 20–80 % RH (non-condensing) |
| IP Rating | IP54 |
| IFOV | 2.3 mrad (standard lens) |
| Field of View | 42° × 30° |
| Minimum Focus Distance | < 0.5 m |
| Visible Light Camera | ≥ 3.1 MP, autofocus, 3.5″ LCD (320 × 240), brightness-adjustable backlight |
| Digital Zoom | 2× / 4× |
| Image Formats | .bmt, .jpg, .bmp, .png, .csv, .xls |
| Internal Memory | 2.8 GB |
| Connectivity | Bluetooth 4.2, Wi-Fi 802.11 b/g/n, USB 2.0 Micro-B |
| Wireless Compatibility | testo 605i (humidity/temperature), testo 770-3 (clamp meter) |
| Software | testo IRsoft (Windows 10/8/7), testo Thermography App (iOS/Android) |
| Compliance | EMC Directive 2014/30/EU, Radio Equipment Directive 2014/53/EU |
| Dimensions | 219 × 96 × 95 mm |
| Weight | 510 g |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 8832 |
| Detector Type | Uncooled Microbolometer FPA (Scanning-Type) |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 320 × 240 pixels (SuperResolution up to 640 × 480) |
| Thermal Sensitivity (NETD) | < 0.04 °C |
| Temperature Range | −30 to +650 °C |
| Accuracy | ±2 °C or ±2 % of reading (whichever is greater) |
| Field of View (Standard Lens) | 30° × 23° |
| IFOV (Standard Lens) | 1.7 mrad |
| Minimum Focus Distance | < 0.1 m |
| Frame Rate | 27 Hz (EU-compliant |
| Display | 3.5" capacitive touchscreen (QVGA, 320 × 240) |
| Image Storage | Internal 2.8 GB memory (.bmt, .jpg, .png, .csv, .xls export) |
| Battery Life | ≥ 5 h |
| IP Rating | IP54 |
| Operating Temperature | −15 to +50 °C |
| Weight | 824 g |
| Compliance | RED 2014/53/EU, EMC 2014/30/EU, WEEE 2012/19/EU, RoHS 2011/65/EU + 2015/863, REACH 1907/2006 |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 8832 |
| Detector Type | Uncooled Scanning Focal Plane Array (FPA) |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 320 × 240 pixels (SuperResolution up to 640 × 480) |
| Thermal Sensitivity (NETD) | < 0.04 °C |
| Field of View | 30° × 23° (standard lens), 12° × 9° (telephoto lens) |
| Spatial Resolution (IFOV) | 1.7 mrad (standard), 0.7 mrad (telephoto) |
| SuperResolution IFOV | 1.1 mrad / 0.4 mrad |
| Frame Rate | 27 Hz (EU-compliant |
| Temperature Range | –30 °C to +650 °C |
| Accuracy | ±2 °C or ±2 % of reading (whichever is greater) |
| Focus | Manual |
| Measurement Method | Non-contact infrared radiometry |
| Operating Temperature | –15 °C to +50 °C |
| Storage Temperature | –30 °C to +60 °C |
| IP Rating | IP54 |
| Battery Life | ≥ 5 hours |
| Weight | 824 g |
| Dimensions | 171 × 95 × 236 mm |
| Display | 3.5" capacitive touch TFT (320 × 240 QVGA), adjustable backlight |
| Image Formats | .bmt, .jpg, .png, .csv, .xls |
| Data Interface | USB-C, Bluetooth 5.0, WLAN (optional module) |
| Software | testo IRSoft (free PC software), testo Thermography App (iOS/Android) |
| Compliance | RED 2014/53/EU, EMC 2014/30/EU, WEEE 2012/19/EU, RoHS 2011/65/EU + 2015/863, REACH 1907/2006 |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | testo 885 |
| Measurement Method | Non-contact |
| Detector Type | Uncooled Microbolometer |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 320 × 240 pixels (76,800 measurement points) |
| SuperResolution Output | 640 × 480 pixels |
| Thermal Sensitivity (NETD) | < 30 mK |
| Temperature Range | –50 °C to +650 °C (extendable to +1200 °C with optional high-temp module) |
| Accuracy | ±2 °C or ±2% of reading |
| Frame Rate | 9 Hz / 33 Hz |
| Operating Temperature | Ambient, uncooled operation |
| Image Format | JPEG with embedded radiometric data |
| Focus | Motorized autofocus, minimum focus distance 10 cm |
| Display | Rotatable fold-out LCD with ergonomic rotating handle |
| Optional Modules | PTA Process Trend Analysis, Full IR Video Recording, Panorama Image Stitching, QR Code-based Asset Tagging, Surface Moisture Risk Imaging, Fever Screening Mode, Interchangeable Lenses, Voice Annotation via Headset, Integrated Visible-light Camera with LED Illumination |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 885 |
| Measurement Method | Non-contact |
| Detector Type | Uncooled Microbolometer |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 320 × 240 pixels |
| SuperResolution Output | 640 × 480 pixels (via software interpolation) |
| Thermal Sensitivity (NETD) | < 30 mK |
| Temperature Range | –50 °C to +650 °C (extendable to +1200 °C with optional high-temp module) |
| Accuracy | ±2 °C or ±2% of reading (whichever is greater) |
| Frame Rate | 9 Hz / 33 Hz (selectable) |
| Focus | Motorized autofocus, minimum focus distance 10 cm |
| Display | Articulating foldable LCD with ergonomic rotating handle |
| Image Format | JPEG (radiometric) + embedded visible-light image |
| Video Recording | Full radiometric infrared video (MP4) |
| Optional Modules | PTA Process Trend Analysis, Panoramic Image Stitching, QR Code Auto-Tagging, Surface Moisture Risk Imaging, Fever Screening Mode, High-Temp Measurement Kit, Voice Annotation via headset |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 890 |
| Frame Rate | 33 Hz |
| Temperature Accuracy | ±2 °C or ±2% of reading |
| Temperature Range | −30 to +100 °C |
| Infrared Resolution | 640 × 480 pixels |
| Spectral Range | 7.5–14 µm |
| Thermal Sensitivity (NETD) | < 40 mK at 30 °C |
| Detector Type | Uncooled microbolometer |
| Operating Principle | Passive infrared radiometry based on Planck’s law |
| Image Enhancement | SuperResolution upscaling to 1280 × 960 pixels |
| Focus | Motorized autofocus, minimum focus distance 10 cm |
| Display | Rotating, foldable LCD touchscreen |
| Data Storage | JPEG + embedded radiometric data, SD card (2 GB included) |
| Optional Modules | PTA Process Trend Analysis, IR Video Recording, Panorama Stitching, QR Code Auto-Tagging, High-Temp Extension (up to 1200 °C), Surface Moisture Risk Assessment, Fever Screening Mode |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | testo 890 |
| Frame Rate | 33 Hz |
| Temperature Accuracy | ±2 °C or ±2% of reading |
| Temperature Range | −30 to +100 °C |
| Infrared Resolution | 640 × 480 pixels |
| Spectral Range | 7.5–14 µm |
| Thermal Sensitivity (NETD) | < 40 mK at 30 °C |
| Minimum Focus Distance | 0.1 m (with wide-angle lens) |
| Spatial Resolution (IFOV) | 0.11–1.13 mrad (lens-dependent) |
| SuperResolution Output | 1280 × 960 pixels |
| Measurement Method | Non-contact infrared radiometry |
| Detector Type | Uncooled microbolometer |
| Operating Temperature Class | Ambient-uncooled |
| Brand | testo |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 0563 0890 |
| Price Range | USD 13,500 – 40,500 (est.) |
| Spectral Range | 7.5–14 µm |
| Detector Type | Uncooled Scanning Focal Plane Array (FPA) |
| Thermal Resolution | 640 × 480 pixels |
| NETD | < 40 mK @ 30 °C |
| Frame Rate | 33 Hz |
| Temperature Range | −30 to +100 °C (standard) |
| optional extended ranges | 0 to +350 °C and 0 to +650 °C |
| Accuracy | ±2 °C or ±2% of reading (whichever is greater) |
| Measurement Principle | Non-contact infrared radiometry |
| Operating Mode | Handheld, battery-powered thermal imaging system |
| Origin | Canada |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | TG120 |
| Price | Upon Request |
| Component Category | Light Source |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | ABBE-3L |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured under Thermo Fisher global design & quality standards) |
| Model | Apreo ChemiSEM |
| Pricing | Available upon request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | AQ3010 |
| Measurement Principle | 90° Nephelometric Detection (ISO 7027 Compliant) |
| Light Source | Infrared LED |
| Measurement Range | Auto-ranging 0.01–1000 NTU |
| Resolution | 0.01 NTU (0.01–19.99), 0.1 NTU (20.0–99.9), 1 NTU (100–1000) |
| Accuracy | ±2% of reading +1 LSD (0–500 NTU) |
| Response Time | <6 s |
| Sample Volume | 10 mL |
| Calibration Standards | 0.02, 20.0, 100, and 800 NTU EPA-compliant formazin equivalents |
| Sample Cell | 25 mm diameter, numbered vials |
| Protection Rating | IP67 |
| Power Supply | 4 × AAA alkaline batteries (≥3,000 measurements) or lithium (≥12,000 measurements) |
| Auto-power-off | After 20 min idle |
| Operating Temperature | 0–50 °C (RH 0–90% at 30 °C) |
| Certifications | CE, TÜV 3-in-1 (CSA-US), FCC Part 15 |
| Self-diagnostic Function | Yes, with error code display |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Online Turbidimeter |
| Model | AquaClear |
| Measurement Range | 0–200 NTU |
| Resolution | ±2% of reading (<40 NTU), ±5% of reading (>40 NTU) |
| Accuracy | 0.001 NTU |
| Operating Ambient Temperature | −20 to +60 °C |
| Sample Temperature Range | −5 to +50 °C |
| Flow Rate | 250–500 mL/min |
| Response Time | 90 s to 90% of final value |
| Light Source | Tungsten lamp (≥3-year lifetime) |
| Flow Cell Volume | 135 mL |
| Optical Cell Material | Quartz and anodized aluminum |
| Compliance | EPA Method 180.1 |
| Temperature Units | °C, °F |
| Output Interface | Plug-and-play communication adapter |
| Detection Principle | Nephelometric measurement at 90° (ISO 7027-compliant geometry) |