Optical Instruments
Filter
Showing 6481–6510 of 7810 results
| Brand | Teledyne Lumenera |
|---|---|
| Origin | Canada |
| Model | INFINITY |
| Image Resolution | 2752 × 2192 |
| Pixel Size | 6.5 µm |
| Sensor Format | 1″ |
| Frame Rate | 27 fps |
| Dynamic Range | 16-bit |
| Quantum Efficiency | 95% |
| Interface | USB 3.1 |
| Monochrome/Color | Selectable |
| Brand | Teledyne Lumenera |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Lt Series |
| Price Range | USD $13,500 – $27,000 (est.) |
| Image Resolution | 6576 × 4384 |
| Pixel Size | 6.5 µm |
| Sensor Format | 35 mm |
| Readout Speed | 6 fps |
| Dynamic Range | 16-bit |
| Quantum Efficiency | 95% |
| Sensor Resolution | 3200 × 3200 |
|---|---|
| Pixel Size | 6.5 µm × 6.5 µm |
| Quantum Efficiency | 95% (peak) |
| Full-Frame Readout Speed | 498 fps |
| Sensor Active Area | 20.8 mm × 20.8 mm |
| Diagonal Field of View | 29.4 mm |
| Read Noise | ≤1.2 e⁻ (at 498 fps, 12-bit) |
| Bit Depth | 8/12/16-bit selectable |
| Interface | PCIe Gen3 x4 and USB 3.2 Gen2 |
| Spectral Response | 200–1700 nm (UV-VIS-NIR) |
| Noise Reduction | Pattern Noise Reduction (PNR) & Correlated Double Sampling (CDS) |
| Brand | Teledyne Photometrics |
|---|---|
| Origin | USA |
| Model | Kinetix |
| Image Resolution | 3200 × 3200 |
| Pixel Size | 6.5 µm × 6.5 µm |
| Sensor Format | 20.8 mm × 20.8 mm (29 mm diagonal) |
| Readout Speed | 400 fps at full resolution |
| Dynamic Range | 16-bit |
| Quantum Efficiency | 95% |
| Interface | PCIe Gen3 x4 |
| Cooling | Thermoelectric (TE), adjustable to −10 °C below ambient |
| Brand | Teledyne Photometrics |
|---|---|
| Origin | USA |
| Model | PRIME 95B |
| Sensor Type | Back-Illuminated (BI) sCMOS |
| Quantum Efficiency (QE) | Up to 95% at 600 nm |
| Pixel Size | 11 µm |
| Dynamic Range | True 16-bit |
| Read Noise | <1.0 e⁻ (at high speed) |
| Frame Rate | Up to 43 fps at full 2048 × 2048 resolution |
| Interface | Camera Link HS or USB 3.2 Gen 2 |
| Mount | C-mount (PRIME 95B & PRIME 95B 22 mm), F-mount (PRIME 95B 25 mm) |
| UV Option | PRIME 95B UV (enhanced sensitivity 250–310 nm) |
| Brand | Teledyne Photometrics |
|---|---|
| Sensor Architecture | Back-Illuminated (BSI) sCMOS |
| Resolution Options | 1200 × 1200 |
| Pixel Size Options | 11 µm × 11 µm |
| Quantum Efficiency | 95% (200–1000 nm) |
| Read Noise | 1.0 e⁻ to 1.6 e⁻ |
| Interface | PCIe Gen3 x4 / USB 3.2 Gen 2 |
| Spectral Response | UV-VIS-NIR (200–1000 nm) |
| Cooling | Thermoelectric (TE) regulated to −15 °C below ambient |
| Frame Rate | Up to 43 fps (2048 × 2048, full resolution, USB 3.2) |
| Global Shutter Capability | Yes (effective via synchronized exposure control) |
| Compliance | CE, FCC, RoHS, ISO 9001-certified manufacturing |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model Series | COSMOS |
| Pricing | Upon Request |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | KURO 1200B / KURO 2048B |
| Pixel Size | 11.0 × 11.0 µm |
| Quantum Efficiency | >95% (peak) |
| Read Noise | 1.3 e⁻ rms (median) |
| Full-Well Capacity | 80,000 e⁻ |
| Dynamic Range | 61,500:1 (95 dB) |
| Frame Rate | 82 fps @ 1200 × 1200 (12-bit), 41 fps @ 1200 × 1200 (16-bit) |
| Fill Factor | 100% |
| Spectral Optimization | UV–NIR (180–1100 nm) |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Model | KURO 1200B / KURO 2048B |
| Sensor Type | Back-illuminated sCMOS |
| Resolution | 1200 × 1200 (1.44 MP) / 2048 × 2048 (4.2 MP) |
| Pixel Size | 11 µm × 11 µm |
| Quantum Efficiency | >95% (peak) |
| Read Noise | 1.3 e⁻ rms |
| Dark Current | 0.7 e⁻/pixel/s |
| Full Well Capacity | 80,000 e⁻ |
| Frame Rate | 82 fps (12-bit, KURO 1200B) / 47 fps (12-bit, KURO 2048B) |
| Exposure Time | ≤10 s |
| Shutter Mode | Rolling shutter with effective global shutter capability |
| Software | LightField 64-bit with LabVIEW® and MATLAB® integration, PICAM SDK support |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | NIRvana: LN / NIRvana: 640 / NIRvana: 640ST |
| Sensor Format | 640 × 512 InGaAs FPA |
| Pixel Size | 20 × 20 µm |
| Spectral Range | 0.9–1.7 µm (NIRvana: 640 & 640ST), 0.9–1.55 µm (NIRvana: LN) |
| Peak Quantum Efficiency | up to 85% (0.95–1.5 µm) |
| Operating Temperature | –190 °C (LN), –85 °C (TE-cooled), –65 °C (ST) |
| Frame Rate | up to 110 fps |
| Interface | GigE Vision compliant |
| Bit Depth | 16-bit digitization |
| Readout Modes | 2 MHz / 5 MHz / 10 MHz |
| Software Platform | LightField 64-bit |
| Compliance | FDA 21 CFR Part 11 ready, GLP/GMP audit trail capable, ASTM E1317-22 compatible for spectral radiometric calibration |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Sensor Type | Electron-Multiplying Intensified CCD (emICCD) |
| Gate Width | <500 ps |
| Maximum Gating Repetition Rate | 1 MHz |
| Spectral Acquisition Rate | >10,000 spectra/s |
| Dual-Image Mode (PI-MAX 4 | 1024i): Inter-frame Interval <2 µs |
| Pixel Format Options | 1024×1024 (12.8 µm), 1024×256 (26 µm) |
| Photocathode Types | Gen II/III Unfilmed |
| Phosphor Screens | P43 / P46 / P47 |
| Read Noise | Sub-electron (EM gain enabled) |
| Dark Current | ≤2.5 e⁻/pixel/s |
| Compatibility | Fully compatible with SpectraPro HRS and IsoPlane® imaging spectrometers |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | PIXIS Series |
| Cooling | Up to −90 °C (vacuum-sealed, air/liquid-cooled) |
| Spectral Range | 120–1100 nm |
| QE | Up to 99% (UV-enhanced with eXcelon™) |
| Read Noise | 3–6 e⁻ |
| Dark Current | As low as 0.0004 e⁻/pix/s @ −70 °C |
| Sensor Type | Teledyne e2v CCD (various formats) |
| Software | LightField® with LabVIEW® & MATLAB® integration, IntelliCal® auto-calibration |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Model | ProEM Series |
| Sensor Type | Back-Illuminated EMCCD |
| Effective Pixels | 1024 × 1024 (1.05 MP) |
| Pixel Size | 10 µm |
| Quantum Efficiency | >95% (UV–NIR, via eXcelon™3 technology) |
| Cooling | Vacuum-cooled to –90 °C |
| Readout Speed | Up to 20 kHz spectral rate |
| Frame Rate | Up to 34 fps (full frame) or >3 kHz (spectral mode) |
| Architecture | Frame-transfer |
| EM Gain Calibration | Integrated OptiCAL reference source |
| Software | LightField v8+ with LabVIEW®/MATLAB® integration and PICAM SDK support |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model Variants | 512×512, 1024×1024, 1600×200, 1600×400 |
| Pixel Sizes | 13×13 µm, 13.5×13.5 µm, 20×20 µm, 24×24 µm |
| Sensor Architecture | Back-Illuminated EMCCD with eXcelon3 anti-fringing technology |
| Quantum Efficiency | Up to 95% at 650 nm |
| Cooling | Deep thermoelectric cooling (≤ –90 °C sensor operating temperature) |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model Variants | 512BX3, 1024BX3, 1600 eXcelon3 |
| Pixel Size | 13 × 13 µm, 16 × 16 µm |
| Spectral Range | 180–1100 nm |
| Peak Quantum Efficiency | >95% |
| Cooling | −70°C vacuum-sealed thermo-electric |
| Readout Speed | Up to 34 fps full-frame |
| Interface | GigE Vision compliant |
| Data Depth | True 16-bit |
| Calibration | Built-in OptiCAL reference source with automated gain/offset correction |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model Range | PyLoN 100B/BR, 400B/BR, 2KB, 2KBUV, 2KF, 256E/BR |
| Pixel Size | 20 × 20 µm, 13.5 × 13.5 µm, 26 × 26 µm |
| Cooling | Liquid Nitrogen to –120 °C |
| Dark Current | ≤1 e⁻/pixel/hour |
| Spectral Response | 200–1100 nm |
| Readout Speed | 50 kHz – 4 MHz |
| Interface | Gigabit Ethernet |
| Software | LightField (64-bit) |
| QE Peak | Up to 98% (eXcelon-enhanced deep-depletion back-illuminated) |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | 1024-1.7, 1024-2.2 |
| Pixel Size | 25 µm (W) × 500 µm (H), 25 µm (W) × 250 µm (H) |
| Spectral Range | 800–1700 nm (1024-1.7), 1000–2200 nm (1024-2.2) |
| Digitization | 16-bit ADC |
| Max Acquisition Rate | 6600 spectra/sec |
| Cooling | Liquid nitrogen (77 K) |
| QE Peak | 88% (1024-1.7), 70% (1024-2.2) |
| Dark Current | <0.1 e⁻/pixel/sec @ 77 K |
| Read Noise | <15 e⁻ RMS (typ.) |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Model | PyLoN-IR |
| Sensor Type | Linear InGaAs Photodiode Array |
| Spectral Range | 800–1700 nm (PyLoN-IR:1024-1.7) / 1000–2200 nm (PyLoN-IR:1024-2.2) |
| Pixel Format | 1024 × 1 |
| Pixel Size | 25 µm × 500 µm (1.7) / 25 µm × 250 µm (2.2) |
| Readout Noise | ≤400 e⁻ (high-gain mode) |
| Full Well Capacity | up to 120 Me⁻ (low-gain) |
| QE | >85% (800–1700 nm), ≥70% (1000–2200 nm) |
| Max Spectral Rate | 6600 spectra/s |
| Cooling | Liquid nitrogen to –100 °C |
| Digitization | 16-bit |
| Software Support | LightField 64-bit, PICAM SDK, IntelliCal Wavelength & Intensity Calibration |
| Compliance | Fully compatible with ASTM E131, ISO/IEC 17025 workflows, and FDA 21 CFR Part 11–enabled data acquisition environments |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PyLoN-IR Series (1024-1.7 & 1024-2.2) |
| Spectral Range | 800–1700 nm (PyLoN-IR:1024-1.7) / 1000–2200 nm (PyLoN-IR:1024-2.2) |
| Cooling Temperature | −100 °C |
| Readout Rate | 6600 spectra/s |
| Digitization | 16-bit |
| Sensor Format | 1024 × 1 linear InGaAs photodiode array |
| Pixel Size | 25 µm × 500 µm (1024-1.7) / 25 µm × 250 µm (1024-2.2) |
| Read Noise | 5000 e⁻ (low-gain, 1024-1.7) / 400 e⁻ (high-gain, 1024-1.7) |
| Well Capacity | 120 Me⁻ (low-gain) / 4.5 Me⁻ (high-gain) |
| Exposure Time | Down to 20 µs |
| Quantum Efficiency | >85% (800–1700 nm, 1024-1.7) / 75% (1000–2200 nm, 1024-2.2) |
| Software | LightField v8.x with IntelliCal, PICAM SDK support |
| Compliance | ASTM E131, ISO/IEC 17025-compatible workflows, FDA 21 CFR Part 11-ready audit trail (via LightField) |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | Quad-RO 4320 |
| Pixel Size | 24 × 24 µm |
| Imaging Array | 2084 × 2084 pixels |
| Energy Range | ~3 keV to >20 keV |
| Quantum Efficiency (at 550 nm) | >70% |
| Readout Interface | IEEE 1394a (FireWire) |
| ADC Resolution | 16-bit |
| Maximum Readout Speed | 4 MHz (4 outputs × 1 MHz each) |
| Cooling | Thermoelectric (hot-stage) |
| Scintillator Compatibility | Interchangeable Gd₂O₂S:Tb screens optimized for 8, 12, and 17 keV |
| Software Platform | LightField (64-bit) |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | SOPHIA 2048B / SOPHIA 2048BX |
| Pixel Size | 15 × 15 µm |
| Sensor Architecture | Back-Illuminated CCD |
| Peak Quantum Efficiency | >95% (eXcelon-enhanced for 2048BX) |
| Cooling | ArcTec™ Thermoelectric Vacuum-Sealed Cryogenic System (down to –90 °C) |
| Readout Noise | ~4 e⁻ rms |
| Readout Speed | Up to 16 MHz (quad-port) |
| Interface | USB 3.0 (5 Gb/s), optional fiber-optic extension (up to 50 m) |
| Software Platform | LightField® 64-bit with IntelliCal™, PICAM API, LabVIEW/MATLAB/EPICS compatibility |
| Vacuum Warranty | Lifetime hermetic seal |
| Spectral Compatibility | UV-VIS-NIR (enhanced with eXcelon anti-fringing technology) |
| Mechanical Interface | Standard Nikon F-mount or spectrograph-compatible flange (ConFlat for SOPHIA-XO variant) |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Product Type | Research-Grade Imaging Spectrograph |
| Optical Design | Czerny-Turner (SpectraPro HRS), Schmidt-Czerny-Turner (IsoPlane) |
| Focal Length Options | 150–750 mm (HRS), 160–320 mm (IsoPlane) |
| Spectral Range | 193–1400 nm (UV-VIS-NIR-MIR) |
| Resolution | 0.05–0.4 nm (dependent on model & grating) |
| Pixel Dispersion | 1.03–4.17 nm/mm |
| Entrance Slit Compatibility | Standard motorized slits (10–200 µm) |
| Detector Interface | USB 3.0, RS-232 |
| Grating Mount | Motorized 3-position turret (HRS & IsoPlane) |
| Wavelength Accuracy | ±0.2 nm (IntelliCal-corrected) |
| Aberration Correction | Astigmatism-corrected (IsoPlane), Astigmatism-reduced (HRS) |
| Coating Options | Acton #1900 enhanced Al (193–1200 nm), protected Ag (250–1400 nm), Au (800–1600 nm) |
| Software Platform | LightField v8+ with IntelliCal, ResXtreme, LabVIEW® & MATLAB® SDKs |
| Compliance | GLP/GMP-ready audit trail, FDA 21 CFR Part 11–compatible metadata logging |
| Brand | Telight |
|---|---|
| Origin | France |
| Model | LiveCodim |
| XY Resolution | ≤ 90 nm |
| Z Resolution | < 500 nm |
| Z Imaging Depth | 50 µm |
| Field of View (Confocal) | 80 µm × 80 µm |
| Field of View (Super-Resolution) | 50 µm × 50 µm |
| Imaging Modes | Widefield, Confocal, LiveCodim Super-Resolution |
| Excitation Wavelengths | 405 nm, 488 nm, 561 nm, 640 nm (expandable) |
| Sample Compatibility | Live cells, fixed cells, plant tissues, subcellular structures |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | PIE |
|---|---|
| Origin | USA |
| Model | TEM Cube |
| Vacuum Performance | ≤1×10⁻⁷ Torr (with turbomolecular pump) |
| Chamber Dimensions | 9 in × 9 in × 9 in (229 mm × 229 mm × 229 mm) |
| Sample Holder Capacity | Up to 8 TEM holders (4 per side) with universal adapters for JEOL, Hitachi, Thermo Fisher/FEI, and ZEISS systems |
| Plasma Source | EM-KLEEN remote RF plasma source (O₂, H₂, or ambient air compatible) |
| Vacuum Isolation | Electromagnetically actuated valves per holder port |
| Pump Configuration | Separated turbomolecular or oil-free dry scroll vacuum station |
| Chamber Door | Hinged tempered glass door with mechanical locking knob |
| Operating Temperature | Slightly above ambient (±2 °C stability) |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Lasy633 |
| Key Components | Semiconductor Laser System with Integrated Iodine Absorption Cell and Active Stabilization Electronics |
| Output Power | >2 mW (fiber-coupled), >10 mW (free-space) |
| Tuning Range | ≥300 GHz (≈0.4 nm at 633 nm) |
| Frequency Stability | <5 MHz RMS over 10 min |
| Coherence Length | >50 m |
| Spectral Linewidth | <5 MHz |
| Tuning Resolution | 1 MHz |
| Wavelength Accuracy | ±1 nm (standard) |
| Brand | TEM Messtechnik GmbH |
|---|---|
| Origin | Germany |
| Model | PSD_Position_Sensitive_Detector |
| Category | Optical Component |
| Wavelength Range (Standard) | 380–1100 nm |
| Wavelength Range (Custom) | 180–2600 nm |
| Detector Type | Dual-2D PSD-based 4D position & angle sensor |
| Position Resolution | < 10 nm (PSD 4D e), < 1 µm (PSD 4D i) |
| Angular Resolution | < 10 nrad (PSD 4D e), < 1 µrad (PSD 4D i) |
| Power Handling (CW) | 100 µW – 10 mW |
| Pulse Energy Sensitivity | > 10 nJ |
| Active Area Options | Ø4 mm, Ø10 mm |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Model | FC |
| Channel Count | 4 |
| Frame Count Options | 4-frame & 8-frame modes |
| Spatial Resolution | >25 lp/mm |
| Spectral Response Range | 350–850 nm |
| Gating Width | 3 ns to DC |
| Gating & Delay Adjustment Resolution | 1 ns |
| Delay Adjustment Range | 0–1 s |
| Image Intensifier Cathode Diameter | 18 mm |
| Max Intensifier Gain | 1×10⁴ |
| Sensor Format | 1932 × 1452 (4× binned), 4.5 µm × 4.5 µm pixels |
| A/D Depth | 12-bit |
| Operating Modes | Single-shot 4-frame or 8-frame acquisition with dual-exposure capability |
| inter-frame intervals | ≤1 ns (frames 1–4 and 5–8), 250 ns (between frames 4 and 5 in 8-frame dual-exposure mode) |
| Optical Coupling | Fiber-optic faceplate |
| Phosphor Screen | P47 |
| Inherent Latency | <36.5 µs + 4 µs |
| Timing Jitter (trigger input to gate output) | typical <100 ps, max <200 ps |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | FC Series |
| Pricing | Available Upon Request |
| Channel Count | 2 / 4 / 8 channels |
| Spatial Resolution | >30 lp/mm |
| Spectral Response Range | 350–850 nm |
| Gating Width | 3 ns to DC |
| Gating & Delay Adjustment Resolution | 1 ns |
| Delay Range | 0–10 s |
| Intrinsic Trigger Latency | <120 ns |
| Image Intensifier Cathode Diameter | 18 mm |
| Maximum Intensifier Gain | 1×10⁴ |
| Readout Sensor | 2048×2048 sCMOS, 6.5 µm × 6.5 µm pixel pitch, 13.3 mm × 13.3 mm active area |
| A/D Conversion | 16-bit |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | OLED |
| Price Range | USD 42,000 – 70,000 |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Ture8-based Integrated Glare Measurement System |
| Price | USD 27,500 (approx. ¥200,000) |
| Imaging Luminance Meter | Ture8 (PR-930 equivalent) |
| Sensor | Instrument-grade monochrome CCD |
| Resolution | 3296 × 2472 (≥8.1 MP) |
| FOV (8 mm lens) | 150° × 120° |
| FOV (14 mm lens) | 60° × 50° |
| Luminance Range | 0.005–5×10⁶ cd/m² (with ND filters) |
| Luminance Accuracy | ±5% (8 mm lens, CIE 1931-weighted) |
| Calibration Suite | Uniform-field, lens distortion, gradient, stray-light, illuminance, luminance/chrominance, and geometric scaling calibration |
| Compliant Standards | CIE 117:1995 (UGR), CIE 112:1994 (GR), CIE 140:2000 & CIE 150:2003 (TI), ISO/CIE joint guidance on glare assessment in lighting design |