Optical Measurement Instruments
Filter
Showing 1441–1470 of 3895 results
| Brand | Gigahertz Optik |
|---|---|
| Origin | Germany |
| Model | SphereSpectro 150H |
| Spectral Range (Version 3) | 240–2150 nm |
| Measurement Principle | Dual-parameter radiative transfer-based spectroscopy |
| Key Outputs | Spectral absorption coefficient (μₐ) and reduced scattering coefficient (μₛ′) |
| Typical Measurement Time | < 5 s (standard), ≤ 120 s (high-resolution) |
| Uncertainty Components | ±1% for μₐ/μₛ′ (thickness +1%), −5% (thickness −5%), ±0.01 to −0.06 refractive index deviation impact |
| Brand | Gigahertz Optik |
|---|---|
| Origin | Germany |
| Model | X1-3 |
| Detector Options | XD-45-HB (Blue Light Hazard), XD-45-HUV (UV Hazard) |
| Display | 97×32-pixel LCD, 4-line alphanumeric, LED-backlit |
| Dynamic Range | 0.1 pA to 200 µA |
| Resolution | 0.1 pA |
| Operating Temperature | 5–40 °C |
| Storage Temperature | −10–50 °C |
| Power | 2×AA batteries (≈250 h, no backlight) or USB bus power |
| Weight (XD-45-HUV + cable + FOV adapter) | 250 g |
| Compliance | IEC 62471:2006, EN 62471:2008, IEC TR 62778:2014, EN 14255-1, 2006/25/EC |
| Brand | Gigahertz Optik |
|---|---|
| Origin | Germany |
| Model | X1-3 |
| Detector Compatibility | XD-45-HB (Blue Light Hazard), XD-45-HUV (UV Hazard) |
| Display | 97×32-pixel LCD, 4-line alphanumeric with LED backlight |
| Dynamic Range | 0.1 pA – 200 µA (4-channel amplifier) |
| Resolution | 0.1 pA |
| Power | 2×AA batteries (≈250 h operation, no backlight) or USB bus power |
| Operating Temperature | 5–40 °C |
| Storage Temperature | −10–50 °C |
| Weight | XD-45-HUV detector: 200 g |
| FOV adapter | 50 g |
| Compliance | IEC 62471:2006, EN 62471:2008, IEC TR 62778:2014, EN 14255-1, 2006/25/EC |
| Brand | Gigahertz Optik |
|---|---|
| Model Series | X1-Series (with interchangeable detectors: X1-1-RCH-116-4, X1+VL-3701, X1+RW-3703, X1+RW-3704, PLL-1701+VL-3701) |
| Detector Type | Calibrated Silicon Photodiode (UV-enhanced, VIS-optimized, NIR-sensitive) |
| Spectral Range | 350–1000 nm (configurable per channel) |
| Optical Aperture | 7–11 mm diameter diffuser |
| Irradiance Range | 1 µW/cm² to 400 W/cm² (dependent on detector head) |
| Photometric Matching | f₁′ ≤ 3% (CIE V(λ) compliant) |
| Integration Time | 100 ms to 10 s |
| Output Interface | USB 2.0 (virtual COM port), analog voltage (0–10 V), optional oscilloscope sync |
| Calibration | NIST-traceable, individual detector certificate included |
| Compliance | ISO/IEC 17025 accredited calibration, CE, RoHS, GLP-ready data logging |
| Brand | Gigahertz-Optik |
|---|---|
| Origin | Germany |
| Model | ISS-5P |
| Sphere Diameter | 170 mm |
| Port Diameter | 50.8 mm |
| Coating | Spectralon® (BaSO₄-equivalent) |
| Light Source | 100 W Tungsten-Halogen Lamp |
| CCT Options | 2856 K & 3100 K |
| Spectral Range | 300–2500 nm |
| Calibration Traceability | ISO/IEC 17025-accredited |
| Detector Integration | Real-time CCT, Luminance, and Spectral Radiance Monitoring |
| Aperture Control | Manual (ISS-5P) or Motorized Remote (ISS-17-VAM variant) |
| Optional Diffuser Window | Yes |
| Brand | Gigahertz-Optik |
|---|---|
| Origin | Germany |
| Model | X1 + ISD-3P-Si |
| Spectral Range | 400–1100 nm |
| Detector Type | Silicon photodiode integrating sphere |
| Entrance Aperture | 5 mm Ø |
| Sphere Diameter | 30 mm Ø (ODM98) |
| Typical Minimum Detectable Power | 7.8 nW @ 630 nm, 5.6 nW @ 900 nm |
| Typical Maximum Power | 1.56 W @ 630 nm, 1.13 W @ 900 nm |
| Measurement Modes | CW, pulse energy, radiant exposure (dose), peak-to-peak, Blondel-Rey luminous intensity, data logging |
| Calibration | NIST-traceable, plug-in calibration data via detector head connector |
| Brand | Glucoloop |
|---|---|
| Origin | Switzerland |
| Model | Baobab |
| Center Wavelength | 2720 ± 10 nm |
| Pulse Duration | < 3 ns |
| Pulse Energy | > 1.3 mJ |
| Repetition Rate | < 1.5 kHz |
| Peak Power | > 500 kW |
| Average Power | > 2 W |
| Beam Quality (M²) | < 7 |
| Polarization | Unpolarized |
| Cooling | Forced Air or Water-Cooled (Optional) |
| Warm-up Time | < 15 min |
| Operating Temperature | 15–35 °C |
| Storage Temperature | −20–55 °C |
| Electrical Input | 24 VDC/12 A or 90–264 VAC, 47–63 Hz |
| Dimensions | 420 × 264 × 89 mm³ |
| Weight | 17 kg |
| Mounting | Top-entry, 3-point low-stress through-hole |
| Trigger Options | Internal Clock or External TTL |
| Amplitude Control & Gating | Integrated Fast Electronic Modulation |
| Fiber Coupling | Optional Multimode Fiber Output |
| Stability | >24 h continuous operation under ambient conditions (1 GHz detection bandwidth) |
| Brand | Glucoloop |
|---|---|
| Origin | Switzerland |
| Model | Ivy |
| Output Wavelength | ~2800 nm |
| Pulse Duration | < 3 ns |
| Pulse Energy | >25 µJ |
| Repetition Rate | <1.5 kHz |
| Peak Power | >9 kW |
| Average Power | >37.5 mW |
| Beam Quality (M²) | <1.1 |
| Polarization Extinction Ratio (PER) | >20 dB (vertical) |
| Cooling | Forced Air |
| Warm-up Time | <10 min |
| Operating Temperature | 15–35 °C |
| Storage Temperature | −20–55 °C |
| Electrical Input | 24 VDC/4 A or 90–264 VAC, 47–63 Hz |
| Dimensions | 260 × 230 × 72 mm³ |
| Weight | 6 kg |
| Mounting | Top-entry, 3-point low-stress through-hole |
| Trigger Options | Internal clock (master mode) or external TTL (slave mode) |
| Origin | Russia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GN-5 |
| Pricing | Available Upon Request |
| Brand | Göttingen Laser-Laboratorium Gottingen e.V. |
|---|---|
| Origin | Germany |
| Type | KrF-based UV laser amplifier |
| Model | PowerLine |
| Wavelength | 248 nm |
| Pulse Energy | 30 mJ (seed input > 50 µJ @ 248 nm) |
| Repetition Rate | 0–350 Hz |
| Average Power | >9 W |
| Pulse Width | <1 ps |
| Timing Jitter | ±2 ns (relative to external trigger) |
| Beam Size | 25 × 25 mm² |
| Beam Quality | M² ≈ 2 × diffraction-limited (input M² = 1) |
| Brand | GPD |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Active Diameter Range | 0.5–5 mm |
| Cutoff Wavelength | 1700 nm |
| Shunt Resistance | High (Typ. >1 GΩ @ -10 mV) |
| Responsivity | High (Typ. 1.1 A/W @ 1550 nm) |
| Lens Options | Biconvex, Plano-Convex, Spherical |
| Filter Options | Neutral Density (ND), Bandpass (BP) |
| Package Types | TO-46, TO-18, TO-5, TO-8 |
| Brand | GPD |
|---|---|
| Origin | USA |
| Model | GAP 1.9–2.6 µm |
| Cutoff Wavelengths | 1.9 µm, 2.05 µm, 2.2 µm, 2.6 µm |
| Active Diameter | 0.3 mm – 3.0 mm |
| Package Options | TO-46, TO-18, TO-5 |
| Lens Options | Double-Convex, Plano-Convex, Spherical |
| Filter Compatibility | Neutral Density (ND), Bandpass Filters |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MiniCOL |
| Measurement Principles | Filter-based photometric colorimetry per ASTM D1500, D156, D1209, D5386, D6045, and ISO 2049 |
| Color Scales | Saybolt (–16 to +30), ASTM (0–8), Pt-Co (0–30 or 0–500) |
| Repeatability | < 1.2 (Saybolt), < 0.48 (ASTM), < 0.9 / <5% (Pt-Co, ≤30 / >30) |
| Reproducibility | < 0.14 (Saybolt), < 0.1 (ASTM), < 2 / <10% (Pt-Co, ≤30 / >30) |
| Cycle Time | < 30 s |
| Throughput | 120 samples/h |
| Interfaces | RS-232, USB, PC keyboard port |
| Power | 90–260 V AC, 47–63 Hz, max. 110 W |
| Dimensions | 325 × 250 × 170 mm |
| Weight | 6.5 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | P STAB 500 |
| Pricing | Available Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Online Installation |
| Model | PM 820 2T |
| Measurement Principle | Infrared 90° Nephelometric Scattering (EN ISO 7027 Compliant) |
| Temperature Compensation Range | –10 to 130 °C (manual/automatic, NTC30k or PT1000 sensor support) |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Language Support | English & Chinese |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS) |
| Digital Communication | RS485 Modbus RTU |
| Cleaning Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Alarm Outputs | Two independent Hi/Lo relay outputs (5 A / 250 VAC / 30 VDC, hysteresis configurable) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-mount, pipe-mount, panel-mount |
| Dimensions (H×W×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM 8202T |
| Product Type | Online |
| Operating Temperature | −10 °C to +70 °C |
| Storage Temperature | −20 °C to +70 °C |
| Display | Backlit Graphic LCD |
| Communication | RS485 Modbus RTU |
| Analog Outputs | 2 × Isolated 4–20 mA (≤500 Ω, 0.1% FS) |
| Alarm Outputs | 2 × SPDT Relays (5 A / 250 VAC / 30 VDC) |
| Cleaning Control | Adjustable Interval (0.1–1000 h) & Duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall, Pipe, Panel |
| Dimensions | 144 × 144 × 108 mm |
| Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Temperature Compensation | −10 °C to +130 °C (NTC30K or PT1000 sensor input) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or Optional 24 VDC |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | PM8202 |
| Configuration | Online Fixed-Mount System |
| Measurement Range | 0.0–50.0 g/L |
| Resolution | 0.01 g/L |
| Operating Ambient Temperature | 0–60 °C |
| Accuracy | ±3% of full scale |
| Sensor Type | BSens 550 |
| Optical Principle | 90° Infrared Light Scattering |
| Sensor Housing Material | Stainless Steel |
| Cable Length | 7 m (standard) |
| Max. Process Pressure | 5 bar |
| Sensor IP Rating | IP68 |
| Controller IP Rating | IP65 |
| Display | Dot-matrix LCD with bilingual (English/Chinese) menu |
| Power Supply | 90–260 VAC, 50/60 Hz |
| Analog Outputs | Two isolated 4–20 mA outputs (sludge concentration & temperature), load ≤600 Ω |
| Digital Interface | RS485 Modbus RTU |
| Alarm Outputs | Two programmable relay outputs (5 A / 250 VAC), adjustable hysteresis |
| Cleaning Interval Setting | Field-configurable (1–999 hours) |
| Mounting | Wall-mounted enclosure |
| Enclosure Dimensions | 144 × 144 × 108 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM8202T |
| Product Type | Online |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Temperature Compensation Range | -10 to 130 °C (NTC30K/PT1000) |
| Display | Backlit Graphic LCD |
| Language Support | English & Chinese |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS) |
| Communication | RS485 Modbus RTU |
| Cleaning Output | Adjustable interval (0.1–1000 h), duration (1–1000 s) |
| Alarm Outputs | Two independent Hi/Lo relay outputs (5 A / 250 VAC / 30 VDC) |
| Mounting Options | Wall-mounted, pipe-mounted, panel-mounted |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PR OCON2000 |
| Pricing | Available Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | UK |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | PRO CO N2000 |
| Pricing | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PRO CON2000 |
| Price | Upon Request |
| Measurement Principle | UV-VIS Absorption Spectrophotometry |
| Sensor Range | 0–100 Pt-Co and 0–2000 Pt-Co (customizable) |
| Accuracy | < ±5% F.S. |
| Repeatability | < ±5% F.S. |
| Response Time | < 5 s |
| Sample Flow Rate | 0–2 L/min |
| Max Operating Pressure | < 2 bar |
| Operating Temperature | 0–50 °C |
| Sample Volume per Measurement | < 100 mL |
| Wetted Materials | Quartz, Polypropylene, FPM Fluoroelastomer, Stainless Steel (316L), Borosilicate Glass |
| Display | 8.5" TFT Color Touchscreen (800 × 480 px, LED backlight) |
| Data Storage | 8 GB SD card |
| Analog Output | 4–20 mA (isolated, ≤500 Ω load, accuracy < 0.5%) |
| Relay Outputs | Programmable (5 A NO / 3 A NC @ 277 VAC) |
| Communication | RS485 Modbus RTU (Slave/Master) |
| Power Supply | 100–240 VAC or 24 VDC, 50–60 Hz |
| Power Consumption | < 20 W |
| Enclosure | Wall-mounted stainless steel (EN 1.4435 / AISI 316L) |
| Dimensions (H×W×D) | 430 × 340 × 200 mm |
| Weight | < 14 kg |
| Ingress Protection | IP65 |
| Hazardous Area Certification | ATEX Zone 1/2 optional |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PRO CON2000 |
| Price | Upon Request |
| Measurement Principle | UV-VIS Absorption Spectrophotometry |
| Detection Range | 0–100 Pt-Co and 0–2000 Pt-Co (customizable) |
| Accuracy | < ±5% F.S. |
| Repeatability | < ±5% F.S. |
| Response Time | < 5 s |
| Sample Flow Rate | 0–2 L/min |
| Max Operating Pressure | < 2 bar |
| Operating Temperature | 0–50 °C |
| Sample Volume per Measurement | < 100 mL |
| Wetted Materials | Quartz, Polypropylene, FPM Fluoroelastomer, Stainless Steel (SS 316L), Borosilicate Glass |
| Display | 8.5" TFT Color Touchscreen (800 × 480 px, LED backlight) |
| Data Storage | 8 GB SD card |
| Analog Output | 4–20 mA (isolated, ≤500 Ω load, <0.5% accuracy) |
| Digital Communication | RS485 Modbus RTU (Slave/Master configurable) |
| Relay Outputs | Programmable alarm (5 A NO / 3 A NC @ 277 VAC) |
| Power Supply | 100–240 VAC or 24 VDC, 50–60 Hz |
| Power Consumption | < 20 W |
| Enclosure | Wall-mounted stainless steel (EN 1.4435 / AISI 316L) |
| Dimensions (H×W×D) | 430 × 340 × 200 mm |
| Weight | < 14 kg |
| Ingress Protection | IP65 |
| Hazardous Area Rating | ATEX Zone 1 or Zone 2 optional |
| Brand | GreenPrima |
|---|---|
| Origin | UK |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROC ON2 00 0 |
| Price | Upon Request |
| Measurement Principle | UV-VIS Absorption Spectrophotometry |
| Detection Range | 0–100 Pt-Co and 0–2000 Pt-Co (customizable) |
| Accuracy | < ±5% F.S. |
| Repeatability | < ±5% F.S. |
| Response Time | < 5 s |
| Sample Flow Rate | 0–2 L/min |
| Max Operating Pressure | < 2 bar |
| Operating Temperature | 0–50 °C |
| Sample Volume per Measurement | < 100 mL |
| Wetted Materials | Quartz, Polypropylene, FPM Fluoroelastomer, SS 316L, Borosilicate Glass |
| Display | 8.5" TFT Color Touchscreen (800 × 480 px, LED backlight) |
| Data Storage | 8 GB SD card |
| Analog Output | 4–20 mA (isolated, ≤500 Ω load, accuracy < 0.5%) |
| Digital Communication | RS485 Modbus RTU (Slave/Master configurable) |
| Relay Outputs | Programmable (5 A NO / 3 A NC @ 277 VAC) |
| Power Supply | 100–240 VAC or 24 VDC, 50–60 Hz |
| Power Consumption | < 20 W |
| Enclosure | Wall-mounted stainless steel (EN 1.4435 / ASTM A240 S31603) |
| Dimensions (H×W×D) | 430 × 340 × 200 mm |
| Weight | < 14 kg |
| Ingress Protection | IP65 |
| Hazardous Area Certification | ATEX Zone 1/2 optional |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROC ON2 000 |
| Price | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PROCO N2000 |
| Pricing | Available upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PROCON 2000 |
| Pricing | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PROCON 2000 |
| Pricing | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PROCON 2000 |
| Pricing | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PROCON2000 |
| Pricing | Available Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PROCON2000 |
| Pricing | Available Upon Request |