| Brand | AZ Technology |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | TEMP 2000A |
| Price | Upon Request |
| Measurement Range (Reflectance) | 0.00–1.00 |
| Spectral Range (Broadband IR) | 3–35 µm |
| Emissivity Reference Temperature | 300 K |
| Angular Configuration | Normal-incidence & Hemispherical |
| Sample Diameter Requirements | ≥1 cm (flat), ≥16.5 cm (concave), ≥2.5 cm (convex) |
| Accuracy (Gray Samples) | ±1% FS |
| Accuracy (Non-Gray Samples) | ±3% FS |
| Repeatability | ±0.5% FS or better |
| Display | Digital LCD with selectable emissivity/reflectance output |
| Optical Head Dimensions | 5.25″ × 6.8″ (Ø × L) |
| Control Unit Dimensions | 4.5″ × 7.75″ × 7″ |
| Carrying Case Dimensions | 12.5″ × 17″ × 11″ |
| Weight | Optical Head: 5 lb, Control Unit: 4 lb, Case: 11 lb |
| Warranty | 1 year parts and labor |
| Brand | AZ Technology |
|---|---|
| Origin | USA |
| Model | TESA 2000 |
| Spectral Range (Reflectance) | 250–2500 nm |
| Spectral Range (Emittance) | <3–>35 µm |
| Measurement Accuracy | ±1% FS (gray samples), ±3% FS (non-gray samples) |
| Repeatability | ±0.5% FS or better |
| Sample Diameter Requirement | ≥1 cm |
| Operating Temperature | Ambient |
| Display | Digital LCD with selectable solar reflectance / solar absorptance / IR emittance readouts |
| Optical Head Dimensions | 127 mm × 203 mm |
| Control Unit Dimensions | 190 mm × 140 mm × 76 mm |
| Total System Weight (incl. battery & case) | ~29 kg |
| Compliance | ASTM E408, ISO 9050 (implied), GLP-supporting measurement traceability |
| Brand | AZUP |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | ASR1700 |
| Detector Configuration | Dual-cooled large-format InGaAs & Si CCD array |
| Spectral Range | 350–2500 nm (combined VIS-NIR-SWIR) |
| Spectral Resolution | ≤2 nm @ 700 nm, ≤7 nm @ 1500 nm |
| Pixel Count | 2048 pixels (VIS-NIR), dual-channel SWIR detection |
| Cooling | Thermoelectrically cooled detectors (NIR/SWIR channels) |
| Data Output | Radiance, Reflectance, Transmittance spectra |
| Compliance | ASTM E275, ISO 9001, NIST-traceable calibration options available |
| Brand | AZUP |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | ASR2500 |
| Pricing | Upon Request |
| Brand | k-Space |
|---|---|
| Origin | USA |
| Distributor Status | Authorized Distributor |
| Import Status | Imported |
| Model | BandiT PV |
| Price Range | USD 42,000 – 70,000 |
| Light Source | AAA-Class Steady-State Solar Simulator |
| Spectral Range | 350–1700 nm |
| Temperature Measurement Range | RT to 1300 °C |
| Temperature Resolution | 0.1 °C |
| Measurement Capabilities | Optical Band Gap, Spectral Absorption Profile, Film Thickness & Deposition Rate, Surface Roughness, In-Situ Thermal Monitoring |
| Brand | BATOP |
|---|---|
| Origin | Germany |
| Model | TDS10XX |
| Spectral Range | 0–3.5 THz (free-space configuration) / 0.1–1.5 THz (fiber-coupled configuration) |
| Spectral Resolution | 2 GHz |
| Dynamic Range | >60 dB (up to >70 dB in Z3 variant) |
| SNR at 0.4 THz | 1000 |
| THz Beam Diameter | 12–22 mm |
| Focused Spot Size | 1–2 mm |
| Delay Line Range | 1 ns (standard), up to 1.3 ns (Z3) |
| Minimum Scan Time | 0.5 s |
| Sample Chamber | Purgeable with N₂ |
| Weight | 50 kg |
| Dimensions | 60 cm × 60 cm × 25 cm |
| Laser Wavelength Options | 1550 nm, 1060 nm, 780 nm |
| THz Emitter/Detector | Photoconductive Antenna with Parabolic THz Lenses |
| Data Acquisition | Lock-in Amplifier + Pulse Generator |
| Control Software | T3DS (Windows-based, customizable API) |
| Brand | Duma Optronics |
|---|---|
| Origin | Israel |
| Model | Beam On LA |
| Spectral Range | 350–1310 nm (VIS–NIR) |
| Max Power Density | 100 J/cm² or 100 W/cm² |
| Max Frame Rate | 25 Hz |
| Image Resolution | 720 × 576 pixels |
| Shutter Speed | 1/50 to 1/100,000 sec (9 steps) |
| Gain Control | 6–60 dB (16 steps) |
| Optical Dynamic Range | up to 1×10¹⁰ (with ND1000 filter + software-controlled shutter/gain) |
| Sensor Active Area | 58 mm × 45 mm |
| Minimal Detectable Beam Size | ≥5 mm |
| Sensitivity | 0.1 μW/cm² @ 633 nm |
| Saturation Limit | 100 W/cm² (with NG1000 filter) |
| Damage Threshold | 100 J/cm² |
| Triggering | Adjustable threshold-based pulse capture (1–100 Hz pulsed lasers) |
| Null Mode | CW background subtraction |
| Sensor Weight | 1.1 kg (incl. cable) |
| Brand | Betop Scientific |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MARS1000 |
| Pricing | Upon Request |
| Brand | Betop Scientific |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | RT100 |
| Price Range | USD 14,000 – 28,500 |
| Spectral Range | 200–2500 nm (standard configuration: 380–1050 nm) |
| Sample Stage Dimensions | 195 × 160 mm (W × D) |
| Power Supply | 220 V ±10%, 50 Hz |
| Operating Environment | 10–35 °C, 10–80% RH (non-condensing) |
| Light Source | High-stability halogen lamp (customizable per spectral range and sample type) |
| Integration Sphere | Optional, for diffuse reflectance/transmittance measurement of matte, frosted, or textured surfaces |
| Software | RT100 Control & Analysis Suite with auto-zero, calibration traceability, pass/fail threshold logic, and spectral data export (CSV, XML) |
| Brand | Top |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | BGD-1 |
| Pricing | Upon Request |
| Timing Accuracy | ±0.1 s |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Multi-DM |
| Pricing | Upon Request |
| Brand | Alicona |
|---|---|
| Origin | Austria |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | FocusX |
| Price | USD 245,000 (FOB Vienna, ex-works, configuration-dependent) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SM25 |
| Pricing | Upon Request |
| Brand | CEL (China Education Goldsource) |
|---|---|
| Model | CEL-IS151 |
| Focal Length | 150 mm |
| f-number | f/4.5 |
| Stray Light | ≤5×10⁻⁴ |
| Minimum Wavelength Step | 0.0045 nm |
| Grating Dimensions | 30 mm × 30 mm |
| Standard Gratings | 7OG1200-300 (1200 grooves/mm, λₚ = 300 nm) & 7OG600-1000 (600 grooves/mm, λₚ = 1000 nm) |
| Slit Width Range | 10 μm – 3 mm (motorized, 10 μm knife-edge protected) |
| Slit Height | 5 mm |
| Housing Dimensions | 298 mm × 200 mm × 185 mm |
| Optical Center Height | 140 mm (±5 mm adjustable) |
| Weight | 10 kg |
| Filter Wheel | 6-position, motorized, Φ18 mm × 2 mm capacity, auto-zeroing on activation |
| Optical Layout | Exit and entrance ports orthogonal |
| Brand | CEL (China Education Goldsource) |
|---|---|
| Model | CEL-IS302 |
| Focal Length | 300 mm |
| f-number | f/4.8 |
| Stray Light | ≤5×10⁻⁴ |
| Minimum Step Resolution | 0.0023 nm |
| Grating Dimensions | 55 mm × 55 mm × 6 mm |
| Standard Grating Set | 1200 g/mm (λₚ = 300 nm), 600 g/mm (λₚ = 750 nm), 300 g/mm (λₚ = 1250 nm) |
| Slit Width Range | 10 μm – 3 mm (motorized, 10 μm knife-edge with auto-protection) |
| Slit Height | 14 mm |
| Dimensions (L×W×H) | 390 mm × 278 mm × 204 mm |
| Weight | 16 kg |
| Brand | Chotest |
|---|---|
| Model | W402 |
| Light Source | White LED |
| Imaging Sensor | 1024 × 1024 pixels |
| Standard Objective | 10× (optional: 2.5×, 5×, 20×, 50×, 100×) |
| Zoom Lens | 0.5× standard (optional: 0.375×, 0.75×, 1×) |
| FOV (10×) | 0.98 × 0.98 mm |
| XY Stage | 140 × 100 mm travel, 320 × 200 mm footprint, 10 kg load capacity |
| Z Focus Range | 100 mm motorized |
| Vertical Resolution | ≤ 0.1 nm (environmental noise evaluation mode) |
| Surface Reflectivity Range | 0.05% – 100% |
| Dimensions (H×W×D) | 900 × 700 × 600 mm |
| Vibration Isolation | Active air-bearing optical table base |
| Brand | Chotest |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | W412 |
| Price | USD 135,000 (FOB Guangdong) |
| Brand | CILAS |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MONO31-100 LULI |
| Pricing | Upon Request |
| Brand | Cinogy |
|---|---|
| Origin | Germany |
| Model | CinAlign / CinFocus for Telecom Applications |
| Wavelength Range | 320–1610 nm (covering 850 nm, 1310 nm, 1550 nm) |
| Spot Size Measurement Range | CinAlign: 52 µm – 4 mm |
| CinFocus | 1.1 µm – 4 mm |
| Camera Sensors | CinCam CMOS-1202 (320–1350 nm), CinCam CMOS-1201-IR (1470–1610 nm) |
| Pixel Size | 5.2–5.3 µm |
| Resolution | 1280 × 1024 |
| Bit Depth | 8-bit |
| Dynamic Range | >61 dB |
| Interface | USB 2.0 |
| Operating Modes | CW and pulsed (CinAlign) |
| Microscope Objectives | 10×, 20×, 40× (CinFocus) |
| Attenuation Options | OD 1.0–OD 5.0 |
| Max Input Power (CinFocus) | 100 mW |
| Compliance | ISO 11146-1/-2, ISO 13694, ISO 11554, IEC 60825-1 |
| Brand | auniontech (Distributor) |
|---|---|
| Origin | Germany |
| Manufacturer | Cinogy GmbH |
| Model | CinCam Pico CMOS-1201-Pico |
| Sensor Type | CMOS |
| Active Area | 5.7 mm × 4.3 mm |
| Pixel Count | 2560 × 1920 |
| Pixel Size | 2.2 µm × 2.2 µm |
| Spectral Range (Standard) | 400–1150 nm |
| Optional Ranges | 150–1150 nm (UV), 240–1150 nm (OM), 320–1150 nm (RT), 400–1320 nm + 1470–1605 nm (IR) |
| Dynamic Range | 70 dB |
| Mechanical Dimensions | 15 mm × 15 mm × 11.5 mm |
| Interface | USB 2.0 |
| Mount | C-mount / F-mount compatible |
| Software | RayCi-Lite / Standard / Pro |
| Data Export Formats | TIFF, PNG, PDF, Excel, AVI, MP4 |
| Compliance | CE, RoHS, ISO 9001 manufacturing environment |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | COLOSUS |
| Price Range | USD 7,000 – 14,000 |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | V2 |
| Price | USD 138,000 (FOB) |
| Brand | SYNOPTICS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Cr,Tm,Ho:YAG |
| Wavelength | 2080 nm |
| Matrix | Y₃Al₅O₁₂ (YAG) |
| Doping Concentrations | Cr³⁺ 0.85 at.%, Tm³⁺ 5.90 at.%, Ho³⁺ 0.36 at.% |
| Crystal Orientation | [111] ± 5° |
| Wavefront Distortion | < λ/2 per inch @ 1064 nm |
| Surface Flatness | λ/10 @ 633 nm |
| Parallelism | < 30 arcsec |
| Perpendicularity | < 5 arcmin |
| Surface Quality | 10-5 (MIL-O-13830A) |
| AR Coating | R < 0.25% @ 2080 nm |
| Damage Threshold | > 10 J/cm² (ns pulse) |
| Pump Band | 400–800 nm |
| Diode Pump Wavelength | 781 nm |
| Absorption Bandwidth | 4 nm FWHM @ 781 nm |
| Fluorescence Lifetime | 8.5 ms |
| Stimulated Emission Cross-Section | 7 × 10⁻²¹ cm² |
| Refractive Index | ~1.8 @ 2080 nm |
| Brand | Colorimetry Research (CRI) |
|---|---|
| Origin | USA |
| Model | CR110-TA |
| Wavelength Range | 380–780 nm |
| Luminance Range | 0.002–1000 cd/m² (with ND2 filter) |
| Polarization Error | ≤0.1% |
| ADC Resolution | 16 bits |
| Electro-optical Bandwidth | 2 MHz |
| Max Sampling Rate | 200 kS/s |
| Min Sampling Period | 5 µs |
| Synchronization Frequency | 10–500 Hz (custom up to 10 kHz) |
| Exposure Time | 20 ms |
| Interface | USB 2.0, Ethernet, RS-232 |
| Power | 5 V, 120 mA via USB 2.0 |
| Mass | 0.34 kg |
| Spot Size Equation | 23.0 mm + 0.08732 × distance (mm) |
| Noise Filtering | Proprietary smart noise filter |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CSLMS-4021 |
| Pricing | Available Upon Request |
| Brand | D&S |
|---|---|
| Origin | USA |
| Model | AE1 RD1 |
| Emissivity Range | 0.05–0.95 (total hemispherical) |
| Measurement Principle | Null-comparison radiometric method with heated detector cavity |
| Sample Temperature Range | Up to 54 °C (130 °F), must match reference standard temperature |
| Minimum Sample Diameter | 5.7 cm (2.25 in) |
| Detector Response Time | ≤10 s per reading |
| Repeatability | ±0.01 |
| Linearity Error | <±0.01 over full emissivity scale |
| Output | 2.4 mV at 25 °C, ε=0.9, 150 Ω load |
| Power Supply | 100–240 V AC, 50–60 Hz, converted to 12 V DC |
| Standard Bodies Included | Two high-emissivity (ε≈0.95) and two low-emissivity (ε≈0.05) reference standards |
| Thermal Equilibration | External heat sink required to maintain sample and standard at identical temperature |
| Compliance | Designed for ASTM C1371, ISO 18434-1, and NASA-HDBK-4002A conformance in surface emissivity validation |
| Brand | D&S |
|---|---|
| Origin | USA |
| Model | AE1/RD1 |
| Measurement Principle | Radiometric comparison against calibrated reference standards |
| Emissivity Range | 0.05–0.95 (total hemispherical, at sample temperature ≤ 54 °C / 130 °F) |
| Repeatability | ±0.01 |
| Response Time | 10 s per reading |
| Minimum Sample Diameter | 5.7 cm (2.25 in) |
| Output Linearity Error | < ±0.01 |
| Standard Bodies Included | Two high-emissivity (ε ≈ 0.95), two low-emissivity (ε ≈ 0.05) reference surfaces |
| Power Supply | 100–240 VAC, 50–60 Hz → 12 VDC adapter |
| Operating Ambient | Stable laboratory environment |
| Compliance | Designed for ASTM C1371, ISO 9277, and ASTM E1933-compliant emissivity validation workflows |
| Brand | DataRay |
|---|---|
| Origin | USA |
| Model(s) | Beam’R2, BeamMap2 |
| Wavelength Range | Si: 190–1150 nm |
| InGaAs | 650–1800 nm |
| Si + InGaAs | 190–1800 nm |
| Si + InGaAs (extended) | 190–2500 nm |
| Measurable Beam Diameter | 2 µm to 4 mm (2 mm for InGaAs variants) |
| Resolution | 0.1 µm or 0.05% of scan range |
| Accuracy | ±<2% beam diameter, ±≤0.5 µm positional |
| Operation Modes | CW and pulsed (min. PRR ≈ [500 / beam diameter (µm)] kHz) |
| M² Measurement Capability | Supported with motorized translation stage (Beam’R2) |
| Max. Power Handling | 1 W total, 0.3 mW/µm² |
| Gain | 32 dB |
| Detector Types | Silicon (Si), Indium Gallium Arsenide (InGaAs) |
| Brand | DataRay |
|---|---|
| Origin | USA |
| Model | LLPS-50, LLPS-200, LBPS-250 |
| Spectral Range | 190–1150 nm (extendable to 163 nm–16 µm) |
| Minimum Line Width | 55 µm |
| Maximum Line Length | 200 mm |
| Maximum Measurable Beam Diameter | 250 mm |
| Pixel Resolution | 4 µm (system-dependent) |
| Transmission Screen Size (LBPS-250) | 200 × 200 mm |
| Effective Imaging Area (LBPS-250) | 170 × 170 µm |
| Lens Focal Length (LBPS-250) | 12.5 mm, f/1.4–f/16 |
| SNR | 2500:1 |
| Brand | DataRay |
|---|---|
| Origin | USA |
| Model | M2DU-WCD, M2DU-BR, WinCamD M² Stage |
| Wavelength Range | 190 nm – 16 µm |
| Translation Stage Travel | 50 mm or 200 mm |
| M² Measurement Range | 1–50 |
| M² Accuracy | ±5% |
| M² Repeatability | ±2% |
| Beam Profiling Method | CCD-based 2D/3D intensity mapping (M2DU-WCD), slit-scanning (M2DU-BR) |
| Compatible Laser Types | CW and pulsed lasers, including diode, solid-state, fiber, and ultrafast sources |