| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | Anatel (a HACH company) |
| Model | UP100 |
| Detection Sizes | 0.1 µm and 0.2 µm (customizable from 0.1–5.0 µm) |
| Sample Flow Rate | 10 mL/min |
| System Flow Rate | >1 L/min |
| Operating Pressure Range | 30–100 psig |
| Light Source | Laser Diode |
| Output | 4–20 mA |
| Clean Recovery Time | <60 seconds |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | CA9400 Single-Channel / Dual-Channel Transmitter |
| Pricing | Available Upon Request |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model Series | COD Pre-Mixed Reagent Vials |
| Price Range | USD 55 – 280 (per kit) |
| Pack Sizes | 25 vials or 150 vials per kit |
| Compatible Instruments | DR6000, DR3900, DR1900, DR900, DR1010 |
| Measurement Ranges | 0.7–40 mg/L, 3–150 mg/L, 20–1500 mg/L, 200–15000 mg/L |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | COSMOS-25 |
| Turbidity Measurement Principle | Dual-channel 90° scattered light (DIN/EN 27027 & ISO 7027 compliant, 860 nm) + 8-angle multi-angle scattering verification |
| SS Measurement Principle | Enhanced multi-angle absorbance (8-channel, 860 nm) |
| Turbidity Range | 0.001–10,000 NTU |
| Turbidity Resolution | 0.001 NTU (0–0.999 FNU), 0.01 NTU (1–9.99 FNU), 0.1 NTU (10–99.9 FNU), 1 NTU (>100 FNU) |
| Turbidity Accuracy | < ±3% of reading |
| Turbidity Repeatability | < ±4% of reading |
| SS Range | ≥0.001 g/L (upper limit medium-dependent |
| SS Resolution | 0.001 g/L (0–0.999 g/L), 0.01 g/L (1–9.99 g/L), 0.1 g/L (10–99.9 g/L), 1 g/L (>100 g/L) |
| SS Accuracy | Medium- and calibration-dependent |
| SS Repeatability | Dependent on sample homogeneity |
| Cleaning | Integrated mechanical self-positioning wiper |
| Signal Transmission | Long-distance analog/digital output without intermediate transmitter |
| Architecture | Modular, field-expandable design |
| Brand | HACH |
|---|---|
| Manufacturer | DKK Toa Corporation |
| Model | BPM-2000 |
| Origin | Japan |
| Compliance | ASTM D86, ASTM D1160, GB/T 6536, GB/T 9168 |
| Explosion Protection | NEPSI Ex dpx IIB+H2 T4 Gb (Cert. No. GYJ14.1186x) |
| Operating System | Windows XP/7 Embedded |
| Display | 10" Color Touchscreen Interface |
| Communication | RS485 MODBUS RTU (up to 15 addresses, baud rates up to 115.2 kbps) |
| Sample Volume | 50 mL |
| Resolution | 0.15 vol% per temperature point |
| Vacuum Option | Optional ASTM D1160-compliant vacuum distillation module |
| Specialized Components | Coated stainless-steel distillation flask, explosion-proof sample cooler (SCU-02), sample conditioning unit, waste recovery unit, voltage stabilizer |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | FBM-160 / FBM-100A |
| Measurement Range | 0–99.9 mg/L, 0–999 mg/L, 0–9990 mg/L |
| Temperature Output (FBM-160 only) | 0.0–50.0 °C |
| Linearity | ±8% FS (controller) |
| Repeatability | ±5% FS (controller) |
| 90% Response Time | ≤60 s |
| Analog Output | DC 4–20 mA (650 Ω, isolated) |
| Digital Output | RS-232C (optional) |
| Alarm Outputs | 4 configurable |
| Power Supply | AC 90–264 V, 50/60 Hz |
| Environmental Rating | IP65 (FBM-160), IP30 (FBM-100A) |
| Operating Ambient | −20 to +55 °C, ≤95% RH |
| Sample pH Range | 4–9 |
| Sample Temperature | 0–40 °C (non-freezing) |
| Minimum Conductivity | 50 mS/m (500 µS/cm) |
| Flow Rate | 0.01–0.2 m/s |
| Interference Constraints | Avoid high concentrations of Ca²⁺, Al³⁺, Fe³⁺ |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | DKK Toa (Japan), Distributed by HACH |
| Model Series | GSS-304A/B/F, GSS-314A/B/F, PSS-304B, PSS-314B, ASS-304B, ASS-314B |
| Sensor Type | Replaceable pH/ORP/Conductivity Electrodes with Non-refillable or Refillable KCl Reference Systems |
| Body Material | Polyphenylene Sulfide (PPS/Ryton®) |
| Operating Temperature Range | 5–100 °C (model-dependent) |
| Max Pressure Rating | 0.2–0.5 MPa |
| Minimum Conductivity for Stable pH Measurement | 100–1000 µS/cm |
| Electrode Mounting Options | Immersion, Insertion (Pipe), Flow-Through, Ultrasonic/Chemical/Pneumatic Cleaning Compatible |
| Compliance | Designed for continuous industrial water and wastewater monitoring per ISO 5667, ASTM D1293, USP <791>, and GLP/GMP-aligned operational traceability |
| Brand | HACH |
|---|---|
| Manufacturer Origin | Japan (DKK Corporation) |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | HSCA-2000 |
| Measurement Principle | Energy-Dispersive X-Ray Fluorescence (EDXRF) |
| Detection Range | 0–10 ppm to 0–1000 ppm (user-selectable) |
| Repeatability | ±2% of full scale |
| Linearity | ±2% of full scale |
| Sample Temperature Limit | ≤60°C |
| Sample Pressure Limit (inlet to flow cell) | ≤0.5 MPa |
| Flow Cell Material | SUS304 stainless steel, Viton seals, coated beryllium window |
| X-ray Source | Low-power end-window micro-focus X-ray tube (9.9 W) |
| Detector | High-sensitivity low-background proportional counter |
| Measurement Cycle | 10–999 s (adjustable) |
| Enclosure Rating | IP55 |
| Explosion Protection | NEPSI Ex dpx IIB+H2 T4 Gb (Cert. No. GYJ11.1655) |
| Power Supply | 90–240 VAC, 50/60 Hz, 70 VA |
| Ambient Operating Conditions | 0–50°C, ≤85% RH |
| Analog Output | 4–20 mA DC (600 Ω load) |
| Alarm Output | 1 dry contact (NC, 0.5 A / 30 VAC or DC) |
| Communication Options | MODBUS RTU/TCP, HART, Ethernet (optional) |
| Utility Requirements | Instrument air (0.4–1.0 MPa, 20 NL/min), helium purge gas (0.5–1.0 MPa, 10–20 NmL/min), optional cooling water |
| Brand | HACH |
|---|---|
| Manufacturer | DKK Toa Corporation |
| Model | ODL-1600 |
| Origin | Japan |
| Instrument Type | Surface Oil Film Detection System |
| Compliance | Designed for continuous oil-in-water monitoring in industrial discharge and intake protection applications |
| Pricing | Available upon request |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | DKK TOA Corporation |
| Model | SPCP-20 |
| Explosion Protection | IEC Ex ia IIC T4 Ga (Cert. Nos. C12661–C12664) |
| Temperature Compensation Range | 0–100 °C (manual, via external thermistor) |
| Temp. Coefficient Adjustment Range | −0.100 to +0.100 pH/°C |
| Output Signal | 4–20 mA DC (two-wire loop-powered) |
| Housing | Die-cast aluminum, adjustable mounting angle |
| Diagnostic Capabilities | Electrode fracture detection, thermistor open/short, hardware fault monitoring |
| Operating Mode Options | Measurement mode / Maintenance mode (output hold: last value, user-defined setpoint, or live reading) |
| Compliance | IEC 60079-0, IEC 60079-11, NEMA 4X equivalent ingress protection |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | SRCP-20 |
| Certification | IECEx/ATEX Ex ia IICT4 (Cert. No. TC15214) |
| Measurement Range | −2000 to +2000 mV |
| Temperature Display Range | 0–100 °C |
| Output | 2-wire 4–20 mA DC, isolated |
| Power Supply | 17.2–27 V DC |
| Accuracy (Output Linearity) | ±0.6% FS |
| Repeatability | < ±3 mV |
| Environmental Rating | IP65 |
| Operating Temperature | −20 to +55 °C |
| Relative Humidity | < 99% RH |
| Enclosure Material | Die-cast aluminum |
| Weight | 2 kg |
| Mounting | 2″ pipe (60.5 mm O.D.) or wall-mount |
| Cable Entry | 3×NPT |
| Brand | HACH |
|---|---|
| Manufacturer Origin | Japan (DKK Corporation) |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | SSM-21P |
| Pricing | Upon Request |
| Brand | Hach |
|---|---|
| Model | DREL/2800 |
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Pricing | Available Upon Request |
| Brand | Hach |
|---|---|
| Model | DREL1900 |
| Type | Portable Laboratory System for Field and Lab-Based Water Analysis |
| Core Instrumentation | Integrated Spectrophotometer (with pre-programmed EPA/ISO-compliant methods), Reagent Kits, Calibration Standards, and Modular Accessories |
| Expandable with | Hach HQ40d Multi-Parameter Meter (pH, Conductivity, DO, ORP, TDS, Salinity, Temperature) and 2100Q Portable Turbidimeter |
| Titration Capability | Manual titration module supporting ≥40–100 assays per reagent set (usage-dependent) |
| Compliance | Designed to support EPA Methods 365.3, 365.4, 8080, 8270, ISO 7027, ISO 8274, and APHA Standard Methods 4500-Cl G, 4500-Br G, 4500-I G |
| Configuration Options | DREL1900 General-Purpose, DREL1900 Complete (with HQ40d & turbidimeter), DREL1900 Industrial |
| Brand | HACH |
|---|---|
| Model | EZ1008.99001102 / EZ1008.99001E02 |
| Measurement Principle | Colorimetry (ASTM D1209 / ASTM D5391 / ASTM D2120B) |
| Wavelength | 465 nm |
| Range | 1–500 Pt-Co |
| Detection Limit | 1 Pt-Co |
| Sample Compatibility | Potable water, treated municipal water |
| Enclosure Rating | IP55 (Analyzer Cabinet), IP65 (Control Panel) |
| Channel Capacity | Up to 8 channels (multi-stream configuration) |
| Output Options | Analog (4–20 mA), Digital (Modbus RTU/TCP, Ethernet/IP) |
| Compliance | ASTM D2120B, ISO 7887, USP <631>, EPA Method 180.1 (adapted) |
| Reagent System | Open-formula, low-volume consumption design |
| Fluidic Architecture | Segregated wet-chemistry and electronics modules |
| Software Functions | Automated calibration, verification, cleaning, startup, and diagnostic routines |
| Regulatory Support | Audit trail, user access control, electronic signature readiness per FDA 21 CFR Part 11 (when deployed with HACH SCADA or iNet software) |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | EZ1016 |
| Detection Limit | 2.5 µg/L (as CaCO₃) |
| Measurement Range | 0–100 ppm (as CaCO₃) |
| Principle | Colorimetric Method (EDTA Complexometric Titration Analog) |
| Reagent Transparency | Open-formula reagents supported |
| Configuration Options | Multi-channel capable |
| Compliance Context | Designed for industrial water reuse monitoring per ISO 9001/QA workflows and compatible with GLP/GMP data integrity expectations |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | EZ4000/5000 Series Hardness and Alkalinity Analyzers |
| Measurement Methods | EDTA potentiometric titration (EZ5000) and colorimetric titration using Ca/Mg indicator at 610 nm or Calcon at 620 nm (EZ4000 hardness) |
| Measured Parameters | Total Hardness, Calcium Hardness, Total Alkalinity, Free Alkalinity |
| Range (EZ4000 Hardness) | 100–1000 mg/L as CaCO₃ (EZ4041/EZ4044) |
| Range (EZ4000 Alkalinity) | 100–5000 mg/L as CaCO₃ |
| Range (EZ5000) | Total Hardness: 25–1000 mg/L |
| Total Alkalinity | 40–1000 mg/L (EZ5011) |
| Total/Calcium Hardness & Total/Free Alkalinity | 25–1000 mg/L / 100–5000 mg/L (other models) |
| Detection Limit (EZ4043) | ≤ 0.05 mg/L as CaCO₃ (LED immersion probe) |
| other models | ≤ 10 mg/L |
| Cycle Time | EZ4000: 10–15 min |
| EZ5000 | 20–30 min (up to 40 min with total + calcium hardness) |
| Operating Temperature | 5–35 °C ±5 °C (avoid direct sunlight and rain) |
| Relative Humidity | 5–95 % RH (non-condensing) |
| Sample Temperature | 10–30 °C |
| Storage Temperature (instrument) | −20 to +55 °C |
| (electrodes) | −15 to +55 °C |
| Power Supply | 110–240 VAC, 4 A, 50/60 Hz |
| Max. Power Consumption | 150 VA |
| Outputs | 4–20 mA (standard 1 channel, up to 8 optional), max. 500 Ω load |
| Pneumatic Supply | Dry, oil-free air per ISA-S7.0.01-1996 |
| Sample Flow Rate | 100–300 mL/min |
| Sample Requirements | Particulates ≤ 100 µm, < 0.1 g/L suspended solids |
| Certifications | CE, UL |
| Enclosure Rating | Analyzer cabinet IP55 |
| Dimensions (H×W×D) | 690 × 465 × 330 mm |
| Shipping Weight | 25 kg |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | EZ7300 Online ATP Analyzer |
| Measurement Principle | Bioluminescence Assay (Luciferin–Luciferase Reaction) |
| Compliance | ASTM D4012-81 |
| Channel Capacity | 8-Channel Simultaneous Flow Analysis |
| Sample Matrix | Process Water, Potable Water, Cooling Water, Power Plant Feedwater |
| Reagent Replacement | Tool-Free Cartridge-Based System |
| Automation Level | Fully Automated, Unattended Operation |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer | HACH Company (a Danaher subsidiary) |
| Product Type | Imported Industrial Online Analyzer |
| Model | FP360 sc |
| Pricing | Available upon Request |
| Brand | HACH/GLI |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 5500 |
| Pricing | Available Upon Request |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | UNIQ Fermentation DO Electrode |
| Pricing | Upon Request |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | HC-7 |
| Pricing | Upon Request |
| Enclosure Material Options | PP, PVC, PVDF, PFA |
| Pressure Rating | Up to 0.15 MPa (pressurized models) |
| Max Flow Rate | ≤2 m/s |
| Reference Electrolyte Volume | ~500 mL (at 1.0 m sleeve length) |
| IP Rating | Rainproof (JIS C 0920 compliant) |
| Operating Temperature Range | Varies by electrode/sleeve combination (–5°C to 120°C) |
| Electrode Types | KCl-refillable pH and ORP electrodes (e.g., models 5600–5615, 2600–2615) |
| Junction Materials | FPM (Viton®), perfluoroelastomer |
| Sleeve Length Options | 0.5–4.0 m (in 0.5 m increments) |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Model | HC3800 sc pH Electrode |
| Pricing | Available upon Request |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Model | UNIQ Fermentation pH Electrode HC9420 |
| Pricing | Available Upon Request |