Empowering Scientific Discovery

Oxford Instruments Technology (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
ModelUltim Max
Detector TypeTilting Insertion Mount
Energy Resolution127 eV (Mn Kα)
Peak-to-Background Ratio200,000:1
Maximum Count Rate1,500,000 cps
Elemental Detection RangeBe to Cf
Active Detector Area40–170 mm²
Window TypeSuper-Atmospheric Thin Window (SATW)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
ModelAZtecPharma
ComplianceFDA 21 CFR Part 11, EU Annex 11, GxP-aligned
Software PlatformAZtecLive-based
User AuthenticationIntegrated Windows Active Directory / LDAP
Audit TrailImmutable, timestamped, user-attributed, inspector-accessible
Digital SignatureEnforced per action (acquisition, processing, reporting)
SOP IntegrationConfigurable acquisition profiles with version-controlled parameters
Real-time EDS ImagingElemental mapping with live spectral overlay comparison
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
ModeliXon 888
Pixel Size13 µm
Sensor TypeBack-Illuminated Electron-Multiplying CCD
Quantum Efficiency>95% (peak)
CoolingThermoelectric (−80 °C typical operating temperature)
Readout ModesEMCCD and conventional CCD
Frame RateUp to 30 fps at full resolution (configurable via ROI and binning)
InterfaceUSB 3.0
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUSA
Model5000 Series
Max Anode Current1.0 mA
Max Anode Voltage50 kV
Max Power50 W
Filament Nominal Voltage2.0 V @ 50 kV, 1 mA
Filament Max Current1.7 A
Stability (4 hr)±0.2%
Nominal Focal Spot Size110 µm
Anode Material OptionsW, Mo, Rh (custom anodes available)
Beryllium Window Thickness Options75 µm, 125 µm, 250 µm
Approx. Weight1.816 kg (4 lbs)
Cooling MethodCompressed Air @ 150 CFM
Beam Divergence Angle25°
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
ModelTritonXL
Minimum Base Temperature< 5 mK
Refrigeration Power1000 µW at 100 mK
Maximum Magnetic Field CompatibilityUp to 16 T
Integrated CryocoolersDual 1.5 W Pulse Tube Refrigerators
Standard Warranty3 years (covers all system components, including third-party cryocoolers, pumps, and electronics)
Service SupportFactory-authorized service network across UK, Germany, USA, China, Japan, and India
Vibration MitigationRemote pump rack, rigid floor-standing cryostat support, electrical isolation between cryostat, gas lines, and pump station
Gas Handling SystemDry, oil-free pumping stack (roots + diaphragm + turbomolecular pumps), fully welded pneumatic circuit with high-integrity solenoid valves
Sample AccessTop- and bottom-loading options
RF Wiring CapacityUp to 72 semi-rigid coaxial lines with optimized attenuators
Optical IntegrationOptional fiber feedthroughs or optical windows
Control InterfaceAdvanced software suite with remote command protocol (TCP/IP), hardware interlocks, and audit-trail-capable operation logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
ModeliXon Ultra 897
Pixel Size16 µm
Readout Speed17 MHz (full frame)
Frame Rate56 fps (512 × 512), 595 fps (128 × 128 ROI)
CoolingThermoelectric to −100 °C
Quantum EfficiencyExtended back-illuminated response (EX2 technology)
Gain CalibrationRealGain™ and EMCAL™
InterfaceUSB 2.0 with raw data access
Operating ModesEMCCD and conventional CCD
Software FeaturesOptAcquire, iCam, Counting Conversion, Edge Suppression
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelCypher S
Instrument TypeMaterials-Focused AFM
Closed-Loop Noise (X,Y)<0.06 nm
Closed-Loop Noise (Z)<0.05 nm
Height Noise<0.015 nm
Sample Diameter<15 mm (standard), <7 mm (high-stability configuration)
XY Stage Travel Range180 mm × 180 mm
Imaging SpeedUp to 10–100× faster than conventional AFMs
Probe CompatibilitySupports ultra-small probes (e.g., 3 × 9 µm optical spot size, optional)
Environmental FlexibilityUpgradeable to Cypher ES (environmental control) and Cypher VRS (video-rate scanning)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
Country of OriginGermany
Modelalpha300S
Detection PrincipleAperture-type Scanning Near-Field Optical Microscopy (SNOM)
Lateral Resolution~60 nm
Operating ModesTransmission & Reflection
Compatible DetectorsHigh-sensitivity PMT & APD with overload protection
Integrated SpectroscopyUHTS spectrometer compatible
Multimodal CapabilitiesCombined AFM, Confocal Microscopy, and SNOM
Environmental OperationAmbient air and liquid environments
Sample PreparationLabel-free, non-destructive, minimal preparation required
Upgrade PathOptional integration with confocal Raman and near-field Raman imaging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
ModelSona 4.2B-6
Image Resolution2048 × 2048
Pixel Size6.5 µm × 6.5 µm
Sensor Dimensions13.3 mm × 13.3 mm
Onboard Memory1 GB
Readout Speed310 MHz
Dynamic Range34,000:1
Quantum Efficiency95%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
ModeliDus
Effective Pixels1024
Pixel Size25 µm
CoolingTE-cooled to –100 °C (iDus 401/420), –95 °C (iDus 416), –90 °C (iDus 491/492)
Sensor TypesBack-illuminated deep-depletion CCD, front-illuminated CCD, InGaAs (1.7 µm & 2.2 µm cutoff)
Peak Quantum Efficiencyup to 95% (CCD), >85% (1.7 µm InGaAs), >70% (2.2 µm InGaAs)
Key TechnologyUltraVac™ vacuum architecture, single fused-silica window, fringe suppression, open-electrode design (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
ModelAZtecTEM
Instrument TypeEDS Software Platform
CompatibilityJEOL 200 kV & 300 kV Transmission Electron Microscopes equipped with JED EDS detectors
Key FeaturesPoint-and-ID analysis, LineScan, Elemental Mapping (TruMap, QuantMap), Drift Correction (AutoLock), Real-time Dynamic Imaging (AZtecLive)
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginFrance
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelC-RED New Space
Effective Pixels640 × 512
Pixel Size15 µm
Full-Frame Frame Rate600 fps
Windowed Mode (32 × 4)32,066 fps
Read Noise<30 e⁻
Dynamic Range93 dB (True 16-bit mode)
Operating Temperature Range-40 °C to +65 °C
Sensor MaterialInGaAs (VGA array)
CoolingAdvanced passive/thermoelectric hybrid thermal management
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
ModelNewton
Sensor Pixel Size13.5 × 13.5 µm or 26 × 26 µm
CoolingThermoelectric (TE) to –100°C
Readout SpeedMulti-Megahertz (up to 3 MHz)
Quantum EfficiencyUp to 95%
Vacuum TechnologyUltraVac™
Sensor ArchitectureEMCCD or conventional CCD
Spectral Acquisition Rate>1600 spectra/sec (Newton 920)
Pixel Array Options1024 × 255, 2048 × 512, or 1600 × 400
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
ModelZyla 4.2 PLUS sCMOS
Image Resolution2048 × 2048
Pixel Size6.5 µm
Sensor Area13 mm × 13 mm
Onboard Memory4 GB
Readout Speed540 MHz
Dynamic Range33,000:1
Quantum Efficiency (QE)82%
InterfaceUSB 3.0
Full-Frame Frame Rate53 fps
FCS ROI Frame Rate (2048 × 8)26,041 fps
Read Noise< 1 e⁻
Linearity99.8%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
ModelX-Pulse
Instrument TypeLow-Field NMR Analyzer
Sample FormLiquid
Operating Frequency60 MHz
Data Acquisition ModePulsed Fourier Transform
Signal-to-Noise Ratio>180:1
Spectral Resolution<0.35 Hz
¹H Quantitative ReproducibilityExcellent
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelGetReal
Price RangeUSD 13,500 – 68,000
Instrument TypeAFM Calibration Module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelalphaCART
Instrument TypePortable Confocal Raman Microscope
Laser Options532 nm, 633 nm, 785 nm (custom wavelengths available)
Spectral Range~90–3500 cm⁻¹ (laser-dependent)
Spatial ResolutionDiffraction-limited
Spectral ResolutionHigh across full range
DetectorScientific-grade low-noise CCD spectrometer camera
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginGermany
Modelalpha300 access
Instrument TypeConfocal Micro-Raman Spectrometer
Spectral Range90–9000 cm⁻¹
Spectral Resolution≤0.2 cm⁻¹
Spatial ResolutionLateral 350 nm, Axial 800 nm
Minimum Wavenumber10 cm⁻¹
Spectral Reproducibility≤±0.02 cm⁻¹
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
ModelMQC-R
Magnet Frequency23 MHz
Probe Diameter Range10–26 mm
Sample Volume CapacityUp to 14 mL
Temperature Control Range (Liquid)–5 °C to +70 °C
Pulsed Field Gradient (PFG) Strength>3.0 T/m
Nuclei Support¹H, ¹⁹F, and other quadrupolar/non-quadrupolar nuclei via configurable probes
ConfigurabilityModular hardware and software options for TD-NMR experiments including 1D/2D relaxation, diffusion, and distribution analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginGermany
Modelalpha300 A
Instrument TypeMaterials-Focused AFM
Position Detection Noise≤0.5 nm
Maximum Sample Diameter120 mm
Piezo Scanner Travel Range (X/Y)≤100 µm
Integrated MicroscopyResearch-Grade Optical Microscope with Brightfield, Darkfield, Polarization & Fluorescence Capabilities
Scanning TechnologyTrueScan™ Capacitive Feedback-Controlled Stage
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelUltim Max TLE
Instrument TypeSide-Insertion EDS Detector
Energy Resolution125 eV (Mn Kα)
Peak-to-Background Ratio200,000:1
Maximum Count Rate>200,000 cps (Xplore TEM), up to 400,000 cps (Ultim Max TLE, quantitative mode)
Elemental Detection RangeBeryllium (Be) to Californium (Cf)
Active Detector Area80 mm² (Xplore TEM), 100 mm² (Ultim Max TLE)
Window TypeWindowless
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMatrix
Price RangeUSD 320,000 – 385,000
Instrument TypeMagnetic Force Microscope (MFM) Control System
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
ModelMechelle 5000
Wavelength Range200–975 nm
Optical ConfigurationFixed-grating, pre-aligned echelle spectrograph
Detector IntegrationIntegrated CCD/CMOS detector option
CoolingThermoelectric (TE) cooled detector
Purge EnvironmentN₂-purged optical path
Temperature StabilizationAuto-temperature correction system
Mechanical DesignCompact, rigid monolithic housing
Moving PartsNone
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0