| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Ultim Max |
| Detector Type | Tilting Insertion Mount |
| Energy Resolution | 127 eV (Mn Kα) |
| Peak-to-Background Ratio | 200,000:1 |
| Maximum Count Rate | 1,500,000 cps |
| Elemental Detection Range | Be to Cf |
| Active Detector Area | 40–170 mm² |
| Window Type | Super-Atmospheric Thin Window (SATW) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | AZtecPharma |
| Compliance | FDA 21 CFR Part 11, EU Annex 11, GxP-aligned |
| Software Platform | AZtecLive-based |
| User Authentication | Integrated Windows Active Directory / LDAP |
| Audit Trail | Immutable, timestamped, user-attributed, inspector-accessible |
| Digital Signature | Enforced per action (acquisition, processing, reporting) |
| SOP Integration | Configurable acquisition profiles with version-controlled parameters |
| Real-time EDS Imaging | Elemental mapping with live spectral overlay comparison |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | iXon 888 |
| Pixel Size | 13 µm |
| Sensor Type | Back-Illuminated Electron-Multiplying CCD |
| Quantum Efficiency | >95% (peak) |
| Cooling | Thermoelectric (−80 °C typical operating temperature) |
| Readout Modes | EMCCD and conventional CCD |
| Frame Rate | Up to 30 fps at full resolution (configurable via ROI and binning) |
| Interface | USB 3.0 |
| Brand | Oxford Instruments |
|---|---|
| Origin | USA |
| Model | 5000 Series |
| Max Anode Current | 1.0 mA |
| Max Anode Voltage | 50 kV |
| Max Power | 50 W |
| Filament Nominal Voltage | 2.0 V @ 50 kV, 1 mA |
| Filament Max Current | 1.7 A |
| Stability (4 hr) | ±0.2% |
| Nominal Focal Spot Size | 110 µm |
| Anode Material Options | W, Mo, Rh (custom anodes available) |
| Beryllium Window Thickness Options | 75 µm, 125 µm, 250 µm |
| Approx. Weight | 1.816 kg (4 lbs) |
| Cooling Method | Compressed Air @ 150 CFM |
| Beam Divergence Angle | 25° |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | TritonXL |
| Minimum Base Temperature | < 5 mK |
| Refrigeration Power | 1000 µW at 100 mK |
| Maximum Magnetic Field Compatibility | Up to 16 T |
| Integrated Cryocoolers | Dual 1.5 W Pulse Tube Refrigerators |
| Standard Warranty | 3 years (covers all system components, including third-party cryocoolers, pumps, and electronics) |
| Service Support | Factory-authorized service network across UK, Germany, USA, China, Japan, and India |
| Vibration Mitigation | Remote pump rack, rigid floor-standing cryostat support, electrical isolation between cryostat, gas lines, and pump station |
| Gas Handling System | Dry, oil-free pumping stack (roots + diaphragm + turbomolecular pumps), fully welded pneumatic circuit with high-integrity solenoid valves |
| Sample Access | Top- and bottom-loading options |
| RF Wiring Capacity | Up to 72 semi-rigid coaxial lines with optimized attenuators |
| Optical Integration | Optional fiber feedthroughs or optical windows |
| Control Interface | Advanced software suite with remote command protocol (TCP/IP), hardware interlocks, and audit-trail-capable operation logging |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | iXon Ultra 897 |
| Pixel Size | 16 µm |
| Readout Speed | 17 MHz (full frame) |
| Frame Rate | 56 fps (512 × 512), 595 fps (128 × 128 ROI) |
| Cooling | Thermoelectric to −100 °C |
| Quantum Efficiency | Extended back-illuminated response (EX2 technology) |
| Gain Calibration | RealGain™ and EMCAL™ |
| Interface | USB 2.0 with raw data access |
| Operating Modes | EMCCD and conventional CCD |
| Software Features | OptAcquire, iCam, Counting Conversion, Edge Suppression |
| Brand | Oxford Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Cypher S |
| Instrument Type | Materials-Focused AFM |
| Closed-Loop Noise (X,Y) | <0.06 nm |
| Closed-Loop Noise (Z) | <0.05 nm |
| Height Noise | <0.015 nm |
| Sample Diameter | <15 mm (standard), <7 mm (high-stability configuration) |
| XY Stage Travel Range | 180 mm × 180 mm |
| Imaging Speed | Up to 10–100× faster than conventional AFMs |
| Probe Compatibility | Supports ultra-small probes (e.g., 3 × 9 µm optical spot size, optional) |
| Environmental Flexibility | Upgradeable to Cypher ES (environmental control) and Cypher VRS (video-rate scanning) |
| Brand | Oxford Instruments |
|---|---|
| Country of Origin | Germany |
| Model | alpha300S |
| Detection Principle | Aperture-type Scanning Near-Field Optical Microscopy (SNOM) |
| Lateral Resolution | ~60 nm |
| Operating Modes | Transmission & Reflection |
| Compatible Detectors | High-sensitivity PMT & APD with overload protection |
| Integrated Spectroscopy | UHTS spectrometer compatible |
| Multimodal Capabilities | Combined AFM, Confocal Microscopy, and SNOM |
| Environmental Operation | Ambient air and liquid environments |
| Sample Preparation | Label-free, non-destructive, minimal preparation required |
| Upgrade Path | Optional integration with confocal Raman and near-field Raman imaging |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Sona 4.2B-6 |
| Image Resolution | 2048 × 2048 |
| Pixel Size | 6.5 µm × 6.5 µm |
| Sensor Dimensions | 13.3 mm × 13.3 mm |
| Onboard Memory | 1 GB |
| Readout Speed | 310 MHz |
| Dynamic Range | 34,000:1 |
| Quantum Efficiency | 95% |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | iDus |
| Effective Pixels | 1024 |
| Pixel Size | 25 µm |
| Cooling | TE-cooled to –100 °C (iDus 401/420), –95 °C (iDus 416), –90 °C (iDus 491/492) |
| Sensor Types | Back-illuminated deep-depletion CCD, front-illuminated CCD, InGaAs (1.7 µm & 2.2 µm cutoff) |
| Peak Quantum Efficiency | up to 95% (CCD), >85% (1.7 µm InGaAs), >70% (2.2 µm InGaAs) |
| Key Technology | UltraVac™ vacuum architecture, single fused-silica window, fringe suppression, open-electrode design (optional) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | AZtecTEM |
| Instrument Type | EDS Software Platform |
| Compatibility | JEOL 200 kV & 300 kV Transmission Electron Microscopes equipped with JED EDS detectors |
| Key Features | Point-and-ID analysis, LineScan, Elemental Mapping (TruMap, QuantMap), Drift Correction (AutoLock), Real-time Dynamic Imaging (AZtecLive) |
| Brand | Oxford Instruments |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | C-RED New Space |
| Effective Pixels | 640 × 512 |
| Pixel Size | 15 µm |
| Full-Frame Frame Rate | 600 fps |
| Windowed Mode (32 × 4) | 32,066 fps |
| Read Noise | <30 e⁻ |
| Dynamic Range | 93 dB (True 16-bit mode) |
| Operating Temperature Range | -40 °C to +65 °C |
| Sensor Material | InGaAs (VGA array) |
| Cooling | Advanced passive/thermoelectric hybrid thermal management |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Newton |
| Sensor Pixel Size | 13.5 × 13.5 µm or 26 × 26 µm |
| Cooling | Thermoelectric (TE) to –100°C |
| Readout Speed | Multi-Megahertz (up to 3 MHz) |
| Quantum Efficiency | Up to 95% |
| Vacuum Technology | UltraVac™ |
| Sensor Architecture | EMCCD or conventional CCD |
| Spectral Acquisition Rate | >1600 spectra/sec (Newton 920) |
| Pixel Array Options | 1024 × 255, 2048 × 512, or 1600 × 400 |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Zyla 4.2 PLUS sCMOS |
| Image Resolution | 2048 × 2048 |
| Pixel Size | 6.5 µm |
| Sensor Area | 13 mm × 13 mm |
| Onboard Memory | 4 GB |
| Readout Speed | 540 MHz |
| Dynamic Range | 33,000:1 |
| Quantum Efficiency (QE) | 82% |
| Interface | USB 3.0 |
| Full-Frame Frame Rate | 53 fps |
| FCS ROI Frame Rate (2048 × 8) | 26,041 fps |
| Read Noise | < 1 e⁻ |
| Linearity | 99.8% |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | X-Pulse |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Form | Liquid |
| Operating Frequency | 60 MHz |
| Data Acquisition Mode | Pulsed Fourier Transform |
| Signal-to-Noise Ratio | >180:1 |
| Spectral Resolution | <0.35 Hz |
| ¹H Quantitative Reproducibility | Excellent |
| Brand | Oxford Instruments |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GetReal |
| Price Range | USD 13,500 – 68,000 |
| Instrument Type | AFM Calibration Module |
| Brand | Oxford Instruments |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | alphaCART |
| Instrument Type | Portable Confocal Raman Microscope |
| Laser Options | 532 nm, 633 nm, 785 nm (custom wavelengths available) |
| Spectral Range | ~90–3500 cm⁻¹ (laser-dependent) |
| Spatial Resolution | Diffraction-limited |
| Spectral Resolution | High across full range |
| Detector | Scientific-grade low-noise CCD spectrometer camera |
| Brand | Oxford Instruments |
|---|---|
| Origin | Germany |
| Model | alpha300 access |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 90–9000 cm⁻¹ |
| Spectral Resolution | ≤0.2 cm⁻¹ |
| Spatial Resolution | Lateral 350 nm, Axial 800 nm |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Reproducibility | ≤±0.02 cm⁻¹ |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | MQC-R |
| Magnet Frequency | 23 MHz |
| Probe Diameter Range | 10–26 mm |
| Sample Volume Capacity | Up to 14 mL |
| Temperature Control Range (Liquid) | –5 °C to +70 °C |
| Pulsed Field Gradient (PFG) Strength | >3.0 T/m |
| Nuclei Support | ¹H, ¹⁹F, and other quadrupolar/non-quadrupolar nuclei via configurable probes |
| Configurability | Modular hardware and software options for TD-NMR experiments including 1D/2D relaxation, diffusion, and distribution analysis |
| Brand | Oxford Instruments |
|---|---|
| Origin | Germany |
| Model | alpha300 A |
| Instrument Type | Materials-Focused AFM |
| Position Detection Noise | ≤0.5 nm |
| Maximum Sample Diameter | 120 mm |
| Piezo Scanner Travel Range (X/Y) | ≤100 µm |
| Integrated Microscopy | Research-Grade Optical Microscope with Brightfield, Darkfield, Polarization & Fluorescence Capabilities |
| Scanning Technology | TrueScan™ Capacitive Feedback-Controlled Stage |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ultim Max TLE |
| Instrument Type | Side-Insertion EDS Detector |
| Energy Resolution | 125 eV (Mn Kα) |
| Peak-to-Background Ratio | 200,000:1 |
| Maximum Count Rate | >200,000 cps (Xplore TEM), up to 400,000 cps (Ultim Max TLE, quantitative mode) |
| Elemental Detection Range | Beryllium (Be) to Californium (Cf) |
| Active Detector Area | 80 mm² (Xplore TEM), 100 mm² (Ultim Max TLE) |
| Window Type | Windowless |
| Brand | Oxford Instruments |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Matrix |
| Price Range | USD 320,000 – 385,000 |
| Instrument Type | Magnetic Force Microscope (MFM) Control System |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Mechelle 5000 |
| Wavelength Range | 200–975 nm |
| Optical Configuration | Fixed-grating, pre-aligned echelle spectrograph |
| Detector Integration | Integrated CCD/CMOS detector option |
| Cooling | Thermoelectric (TE) cooled detector |
| Purge Environment | N₂-purged optical path |
| Temperature Stabilization | Auto-temperature correction system |
| Mechanical Design | Compact, rigid monolithic housing |
| Moving Parts | None |