| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Sona 4.2B-6 |
| Image Resolution | 2048 × 2048 |
| Pixel Size | 6.5 µm × 6.5 µm |
| Sensor Dimensions | 13.3 mm × 13.3 mm |
| Onboard Memory | 1 GB |
| Readout Speed | 310 MHz |
| Dynamic Range | 34,000:1 |
| Quantum Efficiency | 95% |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Zyla 4.2 PLUS sCMOS |
| Image Resolution | 2048 × 2048 |
| Pixel Size | 6.5 µm |
| Sensor Area | 13 mm × 13 mm |
| Onboard Memory | 4 GB |
| Readout Speed | 540 MHz |
| Dynamic Range | 33,000:1 |
| Quantum Efficiency (QE) | 82% |
| Interface | USB 3.0 |
| Full-Frame Frame Rate | 53 fps |
| FCS ROI Frame Rate (2048 × 8) | 26,041 fps |
| Read Noise | < 1 e⁻ |
| Linearity | 99.8% |
| Brand | Oxford Instruments |
|---|---|
| Origin | France |
| Model | C-Blue One |
| Image Resolution | 0.5 MP (812 × 612), 1.7 MP (1608 × 1104), or 7.1 MP (3208 × 2200) |
| Pixel Size | 9 µm (0.5 MP & 1.7 MP variants), 4.5 µm (7.1 MP variant) |
| Sensor Diagonal | 9.6 mm (0.5 MP), 17.6 mm (1.7 MP & 7.1 MP) |
| Interface | CoaXPress 2.0 or SFP+ 10 GigE |
| Bit Depth | 14-bit |
| Quantum Efficiency | >70% @ peak (550–650 nm) |
| Read Noise | <1.5 e⁻ (typical, correlated double sampling) |
| Shutter Type | Global shutter |
| Compliance | GigE Vision v2.0, GenICam3 |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Marana 4.2B-11 |
| Image Resolution | 4.2 MP (2048 × 2048) |
| Pixel Size | 11 µm |
| Sensor Format | 22.5 mm × 22.5 mm (32 mm diagonal) |
| Readout Speed | 100 MHz (16-bit mode) |
| Dynamic Range | 53,000:1 |
| Quantum Efficiency | 95% @ peak (600 nm) |
| Cooling | -45 °C (thermo-electric vacuum-sealed) |
| Brand | Oxford Instruments |
|---|---|
| Origin | France |
| Model | C-Blue One UV |
| Image Resolution | 2848 × 2848 |
| Pixel Size | 2.74 µm |
| Sensor Diagonal | 11.2 mm |
| Interface | CoaXPress 2.0 or SFP+ 10GigE |
| Bit Depth | 14-bit |
| Quantum Efficiency | >70% (peak in UV) |
| Shutter Type | Global Shutter |
| Spectral Range | 200–1000 nm |
| Cooling | Active thermoelectric stabilization down to 0 °C |
| Lens Mount | CS-mount (with C-mount adapter) |
| ADC Modes | 8-bit / 12-bit selectable |
| Analog Gain | up to 24 dB |
| Digital Gain | up to 48 dB |
| ROI & Multi-Window Support | Yes |
| Compliance | GigE Vision v2.0, GenICam v3.x |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | iStar |
| Sensor Resolution | 1024 × 1024 pixels |
| Pixel Size | 13 µm |
| Active Sensor Area | 13.3 mm × 13.3 mm |
| Onboard Memory | 2 GB |
| Readout Speed | 5 MHz |
| Quantum Efficiency | >50% |
| Gating Width | <2 ns |
| Minimum Inter-Frame Interval (PIV mode) | 300 ns |
| Frame Rate (full frame) | up to 4,000 fps |
| Interface | USB 3.0 |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Marana 4.2B-6 |
| Image Resolution | 2048 × 2048 |
| Pixel Size | 6.5 µm × 6.5 µm |
| Sensor Active Area | 13.3 mm × 13.3 mm |
| Onboard Memory | 1 GB |
| Readout Speed | 310 MHz |
| Dynamic Range | 34,000:1 |
| Quantum Efficiency | 95% |
| Cooling Temperature | −45 °C |
| Full-Frame Frame Rate | 74 fps |
| ROI (512 × 512) Frame Rate | 397 fps |
| Read Noise | 1.2 e⁻ |
| Vacuum-Sealed Housing | Yes |
| Mechanical Shutter | None |
| Brand | Andor Technology (Oxford Instruments) |
|---|---|
| Origin | United Kingdom |
| Model | CB2 24B |
| Sensor Resolution | 5328 × 4608 pixels |
| Effective Pixels | 24.5 MP |
| Pixel Size | 2.74 µm (native), 5.48 µm (on-chip 2×2 binning) |
| Read Noise | 1.3 e⁻ RMS |
| Dark Current | 0.0015 e⁻/pixel/sec at −20°C |
| Frame Rates | 106 fps (8-bit), 74 fps (12-bit), 37 fps (16-bit HDR) |
| Shutter Type | Global Shutter |
| Cooling | Thermoelectric (TE) to −20°C |
| Interface | CoaXPress 2.0 or 10 GigE |
| Compliance | GigE Vision v2.0, GenICam v3.x |
| Lens Mount | C-mount (standard), TFL-mount (optional) |
| Operating Ambient Temperature Range | Certified down to −40°C |