BrandOxford Instruments
OriginUnited Kingdom
ModelUltim Max
Detector TypeTilting Insertion Mount
Energy Resolution127 eV (Mn Kα)
Peak-to-Background Ratio200,000:1
Maximum Count Rate1,500,000 cps
Elemental Detection RangeBe to Cf
Active Detector Area40–170 mm²
Window TypeSuper-Atmospheric Thin Window (SATW)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
ModelAZtecTEM
Instrument TypeEDS Software Platform
CompatibilityJEOL 200 kV & 300 kV Transmission Electron Microscopes equipped with JED EDS detectors
Key FeaturesPoint-and-ID analysis, LineScan, Elemental Mapping (TruMap, QuantMap), Drift Correction (AutoLock), Real-time Dynamic Imaging (AZtecLive)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelUltim Max TLE
Instrument TypeSide-Insertion EDS Detector
Energy Resolution125 eV (Mn Kα)
Peak-to-Background Ratio200,000:1
Maximum Count Rate>200,000 cps (Xplore TEM), up to 400,000 cps (Ultim Max TLE, quantitative mode)
Elemental Detection RangeBeryllium (Be) to Californium (Cf)
Active Detector Area80 mm² (Xplore TEM), 100 mm² (Ultim Max TLE)
Window TypeWindowless
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
ModelUnity
Mounting TypeSide-entry (inclined insertion)
Detector ArchitectureIntegrated Backscattered Electron (BSE) and Energy-Dispersive X-ray (EDS) Sensor Assembly
PositioningMounted directly beneath the objective lens pole piece
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelUltim Extreme
Instrument TypeMulti-Detector Configuration
Energy Resolution127 eV (Mn Kα)
Peak-to-Background Ratio20,000:1
Maximum Count Rate500,000 cps
Elemental Detection RangeLi to Bi
Detector Active Area100 mm²
Window TypeWindowless
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
ModelXplore15 / Xplore30
Detector GeometryTilting (Side-entry)
Energy Resolution129 eV @ 100,000 cps
Peak-to-Background Ratio20,000:1
Maximum Count Rate1,000,000 cps
Elemental Detection RangeBoron (B) to Californium (Cf)
Active Crystal Area15 mm² or 30 mm²
Window TypeSuper-Atmospheric Thin Window (SATW)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
ModelXplore TEM
Instrument TypeSide-entry (tilt-compatible) EDS system for TEM
Energy Resolution125 eV (Mn Kα)
Peak-to-Background Ratio200,000:1
Maximum Input Count Rate200,000 cps
Elemental Detection RangeBeryllium (Be) to Californium (Cf)
Detector Active Area80 mm²
Window TypeWindowless (ultra-thin polymer support)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelUltim Extreme Infinity ∞
QuotationUpon Request
Detector TypeSidewall-Insertion (Side-Entry)
Energy ResolutionC Ka ≤ 46 eV @ 50,000 cps
Elemental RangeLi (Z=3) to Cf (Z=98)
Window TypeWindowless
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
ModelUltimMax TLE
Detector TypeTilting Insertion Geometry
Energy Resolution125 eV (Mn Kα)
Peak-to-Background Ratio200,000:1
Maximum Input Count Rate400,000 cps
Elemental Detection RangeBe to Cf
Active Detector Area100 mm²
Window TypeWindowless
Solid Angle0.5–1.1 srad
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
ModelUltimMax TEM
Instrument TypeSide-entry (tilt-compatible)
Energy Resolution125 eV (Mn Kα)
Peak-to-Background Ratio200,000:1
Maximum Count Rate400,000 cps
Elemental Detection RangeBe to Cf
Detector Active Area80 mm²
Window TypeWindowless
Solid Angle0.2–0.6 srad
Low-Energy X-ray Sensitivity GainUp to 8× vs. conventional windowed detectors
In Situ Operation TemperatureUp to 1000 °C
Compatible Accelerating VoltagesUp to 200 kV
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOxford Instruments
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelUltim Max Infinity ∞
QuotationUpon Request
Detector MountingTilting (Side-Entry)
Energy ResolutionC Ka < 46 eV @ 50,000 cps
Elemental Detection RangeBe (Z=4) to Cf (Z=98)
Detector Active Area Options40 mm², 65 mm², 100 mm², 170 mm²
Window TypeSuperATW (Atmospheric Thin Window)