| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Ultim Max |
| Detector Type | Tilting Insertion Mount |
| Energy Resolution | 127 eV (Mn Kα) |
| Peak-to-Background Ratio | 200,000:1 |
| Maximum Count Rate | 1,500,000 cps |
| Elemental Detection Range | Be to Cf |
| Active Detector Area | 40–170 mm² |
| Window Type | Super-Atmospheric Thin Window (SATW) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | AZtecTEM |
| Instrument Type | EDS Software Platform |
| Compatibility | JEOL 200 kV & 300 kV Transmission Electron Microscopes equipped with JED EDS detectors |
| Key Features | Point-and-ID analysis, LineScan, Elemental Mapping (TruMap, QuantMap), Drift Correction (AutoLock), Real-time Dynamic Imaging (AZtecLive) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ultim Max TLE |
| Instrument Type | Side-Insertion EDS Detector |
| Energy Resolution | 125 eV (Mn Kα) |
| Peak-to-Background Ratio | 200,000:1 |
| Maximum Count Rate | >200,000 cps (Xplore TEM), up to 400,000 cps (Ultim Max TLE, quantitative mode) |
| Elemental Detection Range | Beryllium (Be) to Californium (Cf) |
| Active Detector Area | 80 mm² (Xplore TEM), 100 mm² (Ultim Max TLE) |
| Window Type | Windowless |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Unity |
| Mounting Type | Side-entry (inclined insertion) |
| Detector Architecture | Integrated Backscattered Electron (BSE) and Energy-Dispersive X-ray (EDS) Sensor Assembly |
| Positioning | Mounted directly beneath the objective lens pole piece |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ultim Extreme |
| Instrument Type | Multi-Detector Configuration |
| Energy Resolution | 127 eV (Mn Kα) |
| Peak-to-Background Ratio | 20,000:1 |
| Maximum Count Rate | 500,000 cps |
| Elemental Detection Range | Li to Bi |
| Detector Active Area | 100 mm² |
| Window Type | Windowless |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Xplore15 / Xplore30 |
| Detector Geometry | Tilting (Side-entry) |
| Energy Resolution | 129 eV @ 100,000 cps |
| Peak-to-Background Ratio | 20,000:1 |
| Maximum Count Rate | 1,000,000 cps |
| Elemental Detection Range | Boron (B) to Californium (Cf) |
| Active Crystal Area | 15 mm² or 30 mm² |
| Window Type | Super-Atmospheric Thin Window (SATW) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Xplore TEM |
| Instrument Type | Side-entry (tilt-compatible) EDS system for TEM |
| Energy Resolution | 125 eV (Mn Kα) |
| Peak-to-Background Ratio | 200,000:1 |
| Maximum Input Count Rate | 200,000 cps |
| Elemental Detection Range | Beryllium (Be) to Californium (Cf) |
| Detector Active Area | 80 mm² |
| Window Type | Windowless (ultra-thin polymer support) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ultim Extreme Infinity ∞ |
| Quotation | Upon Request |
| Detector Type | Sidewall-Insertion (Side-Entry) |
| Energy Resolution | C Ka ≤ 46 eV @ 50,000 cps |
| Elemental Range | Li (Z=3) to Cf (Z=98) |
| Window Type | Windowless |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | UltimMax TLE |
| Detector Type | Tilting Insertion Geometry |
| Energy Resolution | 125 eV (Mn Kα) |
| Peak-to-Background Ratio | 200,000:1 |
| Maximum Input Count Rate | 400,000 cps |
| Elemental Detection Range | Be to Cf |
| Active Detector Area | 100 mm² |
| Window Type | Windowless |
| Solid Angle | 0.5–1.1 srad |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | UltimMax TEM |
| Instrument Type | Side-entry (tilt-compatible) |
| Energy Resolution | 125 eV (Mn Kα) |
| Peak-to-Background Ratio | 200,000:1 |
| Maximum Count Rate | 400,000 cps |
| Elemental Detection Range | Be to Cf |
| Detector Active Area | 80 mm² |
| Window Type | Windowless |
| Solid Angle | 0.2–0.6 srad |
| Low-Energy X-ray Sensitivity Gain | Up to 8× vs. conventional windowed detectors |
| In Situ Operation Temperature | Up to 1000 °C |
| Compatible Accelerating Voltages | Up to 200 kV |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ultim Max Infinity ∞ |
| Quotation | Upon Request |
| Detector Mounting | Tilting (Side-Entry) |
| Energy Resolution | C Ka < 46 eV @ 50,000 cps |
| Elemental Detection Range | Be (Z=4) to Cf (Z=98) |
| Detector Active Area Options | 40 mm², 65 mm², 100 mm², 170 mm² |
| Window Type | SuperATW (Atmospheric Thin Window) |