Physical Property Testing Instruments
Filter
Showing 9691–9720 of 12279 results
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | THEMYS DUO (formerly TAG) |
| Temperature Range | Ambient to 1750 °C |
| Temperature Accuracy | ±0.25 K |
| Balance Sensitivity | 0.002 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Maximum Sample Mass | 35 g |
| Baseline Drift | ≤5 µg at 1750 °C |
| Simultaneous Sample Capacity | Multiple |
| Atmosphere Control | 3-channel mass-flow-controlled carrier gas (4–200 mL/min) + 1 auxiliary/reactive gas channel (0.3–16 mL/min) |
| Crucible Options | Al₂O₃, W, graphite, Pt, quartz, Al (55–1500 µL) |
| Sensor Configurations | TGA, DTA, and DSC rods (interchangeable) |
| Dimensions (H×W×D) | 170 × 60 × 55 cm |
| Weight | 145 kg |
| Power Supply | 230 V, 50/60 Hz |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Themys Flash |
| Operating Environment | Ambient Pressure |
| Simultaneous Sample Capacity | Up to 5 |
| Instrument Type | Universal TGA |
| Temperature Range | Room Temperature to 1200 °C |
| Dynamic Weighing Range | ±20 mg, ±200 mg |
| Balance Sensitivity | 0.0023 µg |
| Heating/Cooling Rate | Up to 600 K/min |
| Maximum Sample Mass | 35 g |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | THEMYS H2 |
| Temperature Range | Ambient to 1000/1600/1750 °C |
| Heating Rate | 0.01–100 °C/min |
| Max Sample Mass | 35 g |
| Atmosphere | 3 Gas Lines (including dedicated H₂ line) |
| Safety | Dual H₂/O₂ Sensors, Interlocked Furnace & Balance, Emergency H₂ Shutoff, Vacuum- and High-Temp-Interlocked Access |
| Vacuum Level | < 5×10⁻² mbar |
| Resolution | 0.4 μW (DTA), 1 μW (DSC), 0.002 μg (TGA), 0.02 μg (microbalance), 0.2 nm (TMA) |
| Quantitative Accuracy | ±1.4% (DTA), ±0.9% (DSC), ±0.06% (TGA), ±0.08×10⁻⁶/°C (TMA expansion) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Themys |
| Temperature Range | 0–1750 °C (up to 2400 °C in optional configurations) |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 0.00059 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Maximum Sample Mass | 100 g |
| Baseline Drift | ±3 µg |
| Simultaneous Measurement Capability | TGA, DTA, DSC, STA, TMA, EGA |
| Atmosphere Options | Inert, oxidizing, reducing, corrosive (e.g., H₂, NH₃, SO₂, H₂S), vacuum (primary <5×10⁻² mbar |
| Gas Control | Up to 3 independent mass flow controllers (MFCs), programmable gas switching, heated EGA interfaces (4×, up to 300 °C) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | THEMYS HP |
| Temperature Range | Ambient to 1200 °C |
| Pressure Range | Up to 150 bar |
| Sample Capacity | 35 g |
| Balance Sensitivity | 0.0023 µg |
| Baseline Drift | ±200 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Crucible Volume | 1300 µL |
| Gas Configuration | 3-channel mass flow controlled (2 MFCs standard with auxiliary gas option) |
| Vacuum Capability | <1 mbar (primary), <5×10⁻² mbar (forced) |
| Safety Compliance | EU PED 2014/68/EU, Group 2 gases |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | THEMYS LV |
| Temperature Range | Room Temp to 2000 °C (TGA/DTA/TG-DTA), up to 1600 °C (TG-DSC/DSC/TMA) |
| Sample Capacity | Up to 100 g / 18.1 mL |
| Balance Sensitivity | 0.02 µg |
| Heating/Cooling Rate | 0.01–20 K/min |
| Maximum Crucible Volume | 18.1 mL |
| TMA Resolution | 1.6 nm |
| TMA Measurement Range | ±6 mm |
| Gas Control | 3-channel MFC-controlled gas lines (including optional corrosive gas path) |
| Vacuum Capability | Primary vacuum (< 5×10⁻² mbar), secondary vacuum optional |
| Balance Load Capacity | ±200 mg (low-load mode), ±2000 mg (high-load mode) |
| DSC/DTA Accuracy | ±2% (heat flow), ±1 °C (temperature, calibrated vs. metal standards) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Themys One |
| Temperature Range | RT–1150°C / RT–1600°C |
| Heating Rate | 0.01–100 °C/min |
| Atmosphere | Inert or reactive gas |
| Compliance | ASTM E1131, ISO 11358, USP <1227>, ISO 17972 (Cp), GLP/GMP-ready software architecture |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | THEMYS TMA |
| Instrument Type | Thermomechanical Analyzer (TMA) |
| Temperature Range | –150 to 2400 °C (configurable up to 2400 °C with high-temp furnace option) |
| Heating/Cooling Rate | 0–100 °C/min |
| Displacement Resolution | 0.2 nm |
| Displacement Noise | 5 nm |
| Force Range | 0–3.5 N (bidirectional, programmable) |
| Sample Length | 0–20 mm |
| Sample Diameter | ≤10 mm |
| Maximum Displacement Range | ±2 mm |
| Load Capacity | –150 to +350 g (equivalent force range) |
| Probe Options | Compression, Penetration, 3-Point Bending, Tensile, Dilatometric, and Volumetric probes |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | uSC |
| Temperature Range | -40 °C to 200 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.001–1.2 K/min |
| Calorimetric Channels | 4 (2 sample + 2 reference) |
| Sample Cell Volume | 850 µL |
| Baseline Noise | 0.2 µW RMS |
| Sensitivity (Joule effect at 30 °C) | 100 µV/mW |
| Enthalpy Accuracy | ±1% |
| Calorimetric Precision | ±0.1% RMS |
| DSC Resolution | 0.02 µW / 0.002 µW |
| Pressure Range (measurable & controllable) | 400 bar (5800 psi) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Manufacturer | AlyXan (co-developed with SETARAM) |
| Model | VistoMS |
| Detection Principle | Fourier Transform Ion Cyclotron Resonance Mass Spectrometry |
| Mass Range | up to 300 u |
| Mass Accuracy | ≤ 0.01 u |
| Detection Limit | sub-ppm (parts per million) |
| Ionization Mode | Soft chemical ionization (e.g., H₃O⁺ reagent ions) |
| Vacuum Architecture | Dual-stage differential vacuum system (atmospheric pressure interface → primary vacuum → secondary high vacuum measurement region) |
| Sample Introduction | Direct coupling to thermal analyzer (TGA, DSC, or TGA-MS compatible platforms) |
| Measurement Duration per Scan | ~2 seconds |
| Environmental Control | Humidity-regulated gas atmosphere capability |
| Quantification | Calibration-free relative quantitation across full mass range |
| Compatibility | Real-time evolved gas analysis (EGA) for organic and polymeric materials |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Setchkin |
| Pricing | Available Upon Request |
| Brand | SETH |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IPX9K |
| Temperature Range | 80 °C ±5 °C |
| Rainfall Intensity | 10–20 cm/h |
| Droplet Diameter | 0.5–4.5 mm |
| Air Velocity Range | 5–18 m/s |
| Test Duration | 0–999 min |
| Flow Rate | 14–16 L/min |
| Water Pressure | 8,000–10,000 kPa |
| Water Temperature | Ambient to 80 °C ±5 °C |
| Turntable Speed | 5 ±1 r/min |
| Turntable Diameter | Φ400 mm |
| Turntable Load Capacity | ≤20 kg |
| Nozzle Positions | 0°, 30°, 60°, 90° (adjustable distance: 100–150 mm) |
| Chamber Interior | SUS304L stainless steel |
| Exterior | Powder-coated galvanized steel or optional 304 stainless steel |
| Control System | Programmable touchscreen controller with real-time flow/pressure/temperature display |
| Compliance | ISO 16750-1:2006, ISO 20653, IEC 60529, GMW 3172 (2007), VW 80106:2008, QC/T 417.1–2001, GB 4208 |
| Brand | SETH |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SD-225 |
| Temperature Range | -70 °C to +150 °C |
| Temperature Fluctuation & Uniformity | ≤ ±2 °C |
| Cooling Rate | 0.7–1 °C/min |
| Heating Rate | 1–3 °C/min |
| Temperature Control Accuracy | ±0.1 °C |
| Brand | SETH |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | SD-225CS |
| Temperature Range | −70 °C to +150 °C |
| Temperature Fluctuation/Uniformity | ±0.5 °C / ≤2 °C |
| Cooling Rate | 0.7–1 °C/min |
| Heating Rate | 1–3 °C/min |
| Set/Indication Accuracy | ±0.1 °C |
| Brand | SETH |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | SE-FB033 |
| Temperature Range | −40 °C to +80 °C |
| Temperature Uniformity & Stability | ≤ ±2 °C |
| Cooling Rate | 1 °C/min |
| Heating Rate | 3 °C/min |
| Temperature Resolution | 0.1 °C |
| Brand | SETH |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SE-GW-100 |
| Max Temperature | 150–200 °C |
| Type | Air Thermal Aging Chamber |
| Temperature Range | RT+10 °C to 200 °C |
| Temperature Uniformity | ±0.5 °C to ±2.0 °C |
| Temperature Fluctuation | ±0.5 °C to ±1.0 °C |
| Temperature Deviation | ±1.5 °C to ±3.0 °C |
| Heating Rate | ≤40 min (from ambient +20 °C to 200 °C) / ≤60 min (alternative specification) |
| Cooling Rate | 0.7–1.0 °C/min |
| Air Exchange Rate | configurable (cycles/hour) |
| Interior Dimensions (W×H×D) | 450×450×500 mm |
| Construction | Interior – SUS304 stainless steel |
| Heating System | PID + SSR controlled resistive heating |
| Air Circulation | Forced horizontal airflow via multi-blade turbine fan with SETH-optimized duct design |
| Sealing | High-temperature silicone gasket |
| Safety Protections | Over-temperature cut-off, over-current auto-shutdown |
| Controller | PID microprocessor-based digital controller with dual PV/SV display and built-in timer |
| Optional | Tempered glass observation window |
| Brand | SETH |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SE-IPX9K |
| Temperature Range | +80 °C (operating water up to 90 °C) |
| Rain Intensity | 10–20 cm/h |
| Droplet Diameter | 0.5–4.5 mm |
| Air Velocity | 5–18 m/s |
| Test Duration | 0–999 min |
| Water Flow Rate | 14–16 L/min |
| Water Pressure | 8,000–10,000 kPa |
| Water Temperature | Ambient to 80 °C ±5 °C |
| Turntable Speed | 5 ±1 r/min |
| Turntable Diameter | Φ400 mm |
| Turntable Load Capacity | ≤20 kg |
| Nozzle Positions | 0°, 30°, 60°, 90° (adjustable distance: 100–150 mm) |
| Chamber Internal Dimensions | W800 × D800 × H800 mm (customizable) |
| Compliance | ISO 16750-1:2006, ISO 20653, IEC 60529 (IPX9K), GMW 3172 (2007), VW 80106:2008, QC/T 417.1–2001, GB 4208 |
| Brand | SETH |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SE-LX50F |
| Temperature Range | (RT + 10°C) to 55°C |
| Rainfall Intensity | 10–20 cm/h |
| Droplet Diameter | 0.5–4.5 mm |
| Wind Speed Range | 5–18 m/s |
| Test Duration | 0–999 min |
| Power Supply | 220 V / 50 Hz or 110 V / 60 Hz |
| Control System | PLC with Touchscreen Interface |
| Swivel Arm Angle Adjustment | ±20° to ±180° |
| Nozzle Orifice | 0.4 mm (optional 0.8 mm) |
| Water Pressure | 80–100 kPa |
| Turntable Diameter | 700 mm |
| Turntable Height Adjustment | 855–1300 mm |
| Max Load Capacity | 100 kg |
| Timer Range | 1–999 min |
| Weight | 150 kg |
| Compliance | IEC 60529, IEC 60598-1, IEC 60335-1, EN 60335-1, IEC 60950-1, GB 4208, GB 7000.1 |
| Brand | SETH |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SE-SC800B |
| Sand Composition | 97–99% SiO₂ (silicon dioxide) |
| Sand Blasting Concentration | 1.1 g/m³ ±0.25 g/m³ to 2.2 g/m³ ±0.5 g/m³ |
| Sand Blasting Air Velocity | 0–29 m/s |
| Dust Concentration | 0.1–10.6 g/m³ ±7 g/m³ |
| Dust Air Velocity | 8.9 m/s ±1.2 m/s |
| Brand | SETH |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | SE-SCGJB500B |
| Sand Composition | 97–99% SiO₂ (quartz sand) |
| Sand Blasting Concentration | 1.1 g/m³ ±0.25 g/m³ to 2.2 g/m³ ±0.5 g/m³ |
| Sand Blasting Velocity | 0–29 m/s |
| Dust Blowing Concentration | 0.1–10.6 g/m³ ±7% |
| Dust Blowing Velocity | 8.9 m/s ±1.2 m/s |
| Temperature Range | 20–80 °C |
| Humidity Control | ≤30% RH |
| Sand Particle Size (blasting) | 150–850 µm |
| Dust Particle Size (blowing) | ≤149 µm |
| Airflow Regulation | Variable-frequency centrifugal fan |
| Test Standards | GJB 150.12A–2009, GJB 150.12–1986, GJB 360B–2009 Method 110 |
| Brand | SETH |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SED-408CS |
| Temperature Range | −40 °C to +150 °C |
| Temperature Uniformity & Stability | ≤ ±2 °C |
| Cooling Rate | 1 °C/min |
| Heating Rate | 3 °C/min |
| Temperature Control Resolution | 0.1 °C |
| Brand | SETH |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SET-B31 |
| High-Temperature Range | +150 °C |
| Low-Temperature Range | −65 °C |
| Thermal Shock Range | −65 °C to +150 °C |
| Temperature Stability | ±2 °C |
| Heating Rate | 30 °C/min |
| Cooling Rate | 30 °C/min |
| Brand | SETH |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SET-K |
| Price | Upon Request |
| High-Temperature Range | +60 °C to +200 °C |
| Low-Temperature Range | +20 °C to −80 °C |
| Thermal Shock Range | +60 °C to +150 °C |
| Temperature Stability | ±2 °C |
| Heating Rate | 3.5 °C/min |
| Cooling Rate | 1.5 °C/min |
| Brand | SETARAM |
|---|---|
| Model | Setline STA / Setline STA+ |
| Temperature Range | Ambient to 1100 °C |
| Heating Rate | 0.01–50 °C/min |
| Temperature Stability | ±0.05 °C |
| Max Sample Mass | 20 g |
| Atmosphere Options | Air, O₂, Inert (N₂, Ar) |
| Balance Resolution | 0.02 µg |
| TG Dynamic Range | ±200 mg / ±1000 mg |
| DSC Sensitivity | 1 µW |
| DSC Enthalpy Accuracy | ±1% |
| Optional Autosampler | 49-position |
| Cooling Method | Water-cooled furnace liner |
| Software | Calisto 2.0 (Data Acquisition & Processing) |
| Brand | SETARAM |
|---|---|
| Origin | Beijing, China (assembled with French-imported core components) |
| Model | Setline-dsc |
| Temperature Range | –170 to 700 °C |
| Temperature Accuracy | ±0.1 °C (vs. certified metal standards) |
| Heating/Cooling Rate | 0.01–100 K/min |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SFT-D1 |
| Pricing | Upon Request |
| Measurement Range | 0–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Data Acquisition Rate | Up to 23 readings/sec |
| Zeroing Method | One-Touch Auto-Zero |
| Stage Vertical Travel | 0–50 mm |
| Stage Repeatability | ±0.5 µm |
| Stage Speed Control | Programmable, Variable-Speed During Measurement |
| Interface | USB (for stage & software control), RS-232 (for legacy instrument communication) |
| Temperature Sensing Accuracy | ±0.01 °C |
| Temperature Readout | Software-Integrated, Independent Display |
| Dimensions (L×W×H) | 330 × 350 × 580 mm |
| Weight | 20 kg |
| Power Supply | 220 V AC, 3 A |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Salt Solution Temperature | 35 °C ±1 °C (NSS/ACSS) or 50 °C ±1 °C (CASS) |
| Salt Concentration | 5% NaCl (w/v) or 5% NaCl + 0.26 g/L CuCl₂·2H₂O (CASS) |
| Compressed Air Pressure | 1.00 ±0.01 kgf/cm² |
| Fog Collection Rate | 1.0–2.0 mL/80 cm²/h (measured over ≥16 h, arithmetic mean) |
| pH of Salt Solution | 6.5–7.2 (NSS) or 3.0–3.2 (CASS) |
| Internal Chamber Dimensions (W×D×H) | 90 × 60 × 50 cm |
| External Dimensions (W×D×H) | 141 × 88 × 128 cm |
| Temperature Range | −20 °C to 80 °C |
| Humidity Range | 20–98% RH |
| Temp. Resolution/Uniformity | ±0.1 °C / ±1.0 °C |
| RH Resolution/Uniformity | ±0.1% RH / ±3.0% RH |
| Temp. Control Accuracy/Stability | ±1.0 °C / ±0.5 °C |
| RH Control Accuracy/Stability | ±2.0% RH / ±2.0% RH |
| Pressure Tank Temp. | 47 °C ±1 °C (NSS/ACSS) or 63 °C ±1 °C (CASS) |
| Controller | Full-color LCD touch interface with real-time curve logging |
| Programmable Profiles | 140 patterns, 1400 steps, up to 99 repeats per pattern |
| Step Duration Range | 0–999 h 59 min |
| Brand | Shanda |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SD-L2 |
| Sample Capacity | Multi-sample simultaneous measurement |
| Instrument Type | Heat-Flow DSC |
| Temperature Range | −100 °C to 600 °C |
| Programmable Temperature Control | Heating, Isothermal, Cooling |
| Heating/Cooling Rate | 0.1–100 K/min |
| Scan Modes | Dynamic heating, dynamic cooling, isothermal hold |
| Temperature Accuracy | ±0.01 °C (typical, calibrated per ASTM E794 & ISO 11357-1) |
| Baseline Stability | <0.5 µW over 30 min at 50 °C |
| Sensor Resolution | 0.01 µW |
| Temperature Sensing | Dual independent platinum RTD sensors (furnace + sample) |
| Control Algorithm | Adaptive dynamic PID with FTC/STC dual-mode selection |
| Data Acquisition | 1–10 Hz user-selectable sampling rate |
| Communication Interface | USB 2.0 with auto-reconnect protocol |
| Atmosphere Control | Dual independent gas channels (N₂, O₂, Ar, air), software-switched via solenoid valves |
| Calibration Standards | Indium, Zinc, Tin, and Sapphire (per ISO 11357-2) |
| Brand | SHANG ZHUN |
|---|---|
| Origin | Guangdong, China |
| Model | DM49-60 |
| Measurement Range | 0–2.5 mm / 0–6 mm / 0–12 mm (selectable single range per unit) |
| Resolution | 0.1 µm |
| Accuracy | ±1 µm or ±0.1% of reading (whichever is greater) |
| Parallelism Between Measuring Surfaces | ±0.1 µm |
| Test Speed | 10 tests/min (adjustable) |
| Contact Pressure | 17.5 ± 1 kPa (for films, 0.875 N force) or 100 ± 5 kPa (for paper) |
| Contact Area | 50 mm² (Φ8 mm for films) or 200 mm² (for paper) |
| Power Supply | AC 220 V, 50 Hz, 80 W |
| Dimensions | 461 × 334 × 357 mm (L×W×H) |
| Net Weight | ~32 kg |
| Interface | Color touchscreen, bilingual (Chinese/English), unit switching (mm/mil/µm/inch) |
| Data Output | USB/RS232, PC connectivity, remote control, real-time data transfer |
| Software | Optional SHANG ZHUN Thickness Analysis Suite v49-60-1 |
| Brand | SHANG ZHUN |
|---|---|
| Origin | Guangdong, China |
| Model | SZCX-100 |
| Lamp Type | Air-cooled long-arc xenon lamp (1 × 1800 W) |
| Spectral Range | 290–800 nm |
| Irradiance Options | 340 nm, 420 nm, 300–400 nm, 280–800 nm (0–1200 W/m²) |
| Black Panel Temperature Range | 30–100 °C ±3 °C |
| Chamber Temperature Range | 0–80 °C ±2 °C (dark condition) |
| Humidity Range | 20–98 %RH ±2.5 %RH (≥75 %RH) / ±3 %RH (<75 %RH) |
| Light Exposure Duration | 0–999 h (programmable) |
| Rain Cycle | 1–9999 min (adjustable on/off intervals) |
| Internal Dimensions (W×D×H) | 500 × 600 × 500 mm |
| External Dimensions (W×D×H) | ~1150 × 1150 × 1950 mm |
| Cooling Method | Forced-air mechanical refrigeration |
| Total Power | ~4 kW |
| Supply | 220 V ±10%, 50 Hz |