Physical Property Testing Instruments
Filter
Showing 9601–9630 of 12279 results
| Brand | SBS |
|---|---|
| Origin | USA |
| Instrument Type | Portable |
| Measurement Principle | Falling-Pin Viscometry |
| Viscosity Range | 5–10⁶ cP |
| Sample Volume | 4.5 mL |
| Accuracy | ±3% (PDV-100) |
| Repeatability | ±3% |
| Operating Environment | Ambient Temperature |
| Compliance | ASTM D7483, ISO 12058-1 (for falling-body viscometry), GLP-ready workflow support |
| Brand | SCChengyi |
|---|---|
| Origin | Sichuan, China |
| Model | NXS-11B |
| Viscosity Range | 2.8–1.78×10⁷ mPa·s |
| Shear Stress Range | 27.67–21,970 Pa |
| Shear Rate Range | 1.23–996 s⁻¹ |
| Speed Range | 5.6–360 rpm |
| Repeatability | ±1% FS (Newtonian fluids) |
| Construction | Stainless steel coaxial cylinder system |
| Instrument Type | Coaxial Cylinder Rotational Viscometer |
| Portability | Benchtop and handheld operation capable |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LF-TD 150 |
| Instrument Type | Thermo-Hygrometer |
| Measurement Range | RH 0–100 %, Temp −20 to +150 °C |
| Accuracy | ±2.0 % RH (10–90 % RH), ±0.3 °C (10–60 °C) |
| Output | Dual 4–20 mA (RH and Temp, separately scaled) |
| Supply Voltage | 12–29 VDC (nominal 24 VDC) |
| Sensor Probe | Ø12 mm × 750 mm, Stainless Steel |
| Electronics Housing | Anodized Aluminum, IP65 |
| Operating Temp | Sensor Head −20 to +150 °C, Electronics −20 to +85 °C |
| Electrical Interface | 5-pole sensor connector with 5 m integrated cable |
| Optional Interfaces | LCD Display, Relay Output (humidity alarm), RS232, USB, Bluetooth (requires USB), PROFINET, Ethernet, Modbus RTU/TCP |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | VariDens |
| Instrument Type | Benchtop Laboratory Digital Density Meter |
| Measurement Principle | Oscillating U-tube (vibrating tube) densitometry |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0005 g/cm³ (VariDens C), ±0.00005 g/cm³ (VariDens B) |
| Density Repeatability | ±0.0002 g/cm³ (VariDens C), ±0.00002 g/cm³ (VariDens B) |
| Density Resolution | 0.0001 g/cm³ (VariDens C), 0.00001 g/cm³ (VariDens B) |
| Temperature Control Range | 10–95 °C (Peltier-based electronic thermostating) |
| Temperature Accuracy | ±0.05 °C (VariDens C), ±0.03 °C (VariDens B) |
| Temperature Repeatability | ±0.02 °C (VariDens C), ±0.01 °C (VariDens B) |
| Temperature Resolution | 0.01 °C (VariDens C), 0.001 °C (VariDens B) |
| Pressure Rating | 0–10 bar (0–145 psi) |
| Measurement Time | <30 s per sample |
| Bubble Detection | Automatic dual-mode (optical + electronic) |
| Display | 7" color TFT touchscreen |
| Interfaces | SuH-Connector, RS232 serial, 2× USB, Ethernet, optional WLAN |
| Brand | Schmidt+Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | EDM-ρ |
| Measurement Range | 0–3 g/cm³ |
| Density Repeatability | ±1 × 10⁻⁵ g/cm³ |
| Temperature Range | 0–90 °C |
| Temperature Repeatability | ±0.003 °C |
| Density Sensitivity | ±5 × 10⁻⁵ g/cm³ |
| Temperature Sensitivity | ±0.02 °C |
| Measurement Time | ~30 s |
| Minimum Sample Volume | 1 mL |
| Integrated Bubble Detection | Yes |
| Automatic Viscosity Compensation | Yes |
| Integrated Pressure & Humidity Sensors | Yes |
| Display | 5.7" color touchscreen |
| Interfaces | RS232, RS422, 1× USB, memory card slot |
| Power Supply | 90–132 V / 190–264 V AC, 50/60 Hz |
| Dimensions (L×H×W) | 374 × 236 × 454 mm |
| Weight | ~20 kg |
| Compliance | USP <841>, Ph. Eur. 2.2.5, ASTM D1298, ASTM D4052, ISO 12185, DIN 51757, FDA 21 CFR Part 11 (with optional Aquisys®2008 software), GLP/GMP-ready |
| Brand | NYX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HY-628B1 |
| Price Range | USD 1,400 – 7,000 |
| Instrument Type | Oscillating/Reciprocating Tribological Tester |
| Max Friction Force | 0.5–25 N |
| Force Resolution | Not Specified |
| Max Operating Temperature | Ambient Only (No Heating Capability) |
| Cone Apex Angle | 166° |
| Oscillation Frequency | 75 cycles/min |
| Sample Holder Tilt Angle | 7° |
| Contact Load Range | 0.5–25 N (Adjustable) |
| Sample Area | 100 cm² |
| Effective Abrasion Area | 50 cm² |
| Dimensions (L×W×H) | 34 × 60 × 63 cm |
| Net Weight | 50 kg |
| Brand | SCHOTT |
|---|---|
| Origin | Germany |
| Model | AVS370 |
| Measurement Principle | Capillary Flow (Ubbelohde & Ostwald-type) |
| Time Range | 0.01–9999.99 s (resolution: 0.01 s) |
| Kinematic Viscosity Range | 0.35–1800 mm²/s (positive pressure mode) / 0.35–5000 mm²/s (vacuum mode) |
| Timer Accuracy | ±0.01% |
| Temperature Equilibration Time Setting | 0–20 min (in 1-min increments) |
| Replicate Runs | 1–10 per sample |
| Interface | RS-232C |
| Power Supply | 115/230 VAC, 50/60 Hz, 30 W |
| Housing | Anodized aluminum |
| Dimensions (W×H×D) | 225 × 205 × 320 mm |
| Weight | 5.4 kg |
| Compatible Viscometers | DIN Ubbelohde, ASTM Ubbelohde, DIN Micro Ubbelohde, Micro Ostwald, Cannon-Fenske Routine, TC-Ubbelohde, TC-Micro Ubbelohde |
| Brand | SCHOTT |
|---|---|
| Origin | Germany |
| Model | AVS370 |
| Measurement Principle | Capillary efflux time (kinematic viscosity) via photometric and thermal-conductivity detection |
| Pressure Modes | Positive pressure & vacuum aspiration |
| Timer Resolution | 0.01 s |
| Time Range | 0.01–9999.99 s |
| Kinematic Viscosity Range | 0.35–1800 mm²/s (cSt) under positive pressure |
| Timer Accuracy | ±0.01% |
| Pump Control | Microprocessor-regulated ViscoPump II (up to 4 units per chassis) |
| Temperature Equilibration Delay | 0–20 min (user-configurable) |
| Replicates per Sample | 1–10 |
| Interface | RS-232C |
| Power | 115/230 VAC, 50/60 Hz, 30 W |
| Enclosure | Powder-coated aluminum |
| Dimensions (W×H×D) | 225 × 205 × 320 mm |
| Weight | 5.4 kg |
| Compatible Viscometers | DIN Ubbelohde, ASTM Ubbelohde, DIN Micro Ubbelohde, Micro Ostwald, Cannon-Fenske Routine, TC-Ubbelohde, TC-Micro Ubbelohde |
| Brand | SCHOTT |
|---|---|
| Origin | Germany |
| Model | AVSPro |
| Measurement Principle | Capillary Flow (ASTM D445, ISO 3104, IP 71) |
| Kinematic Viscosity Range | 0.35–1200 mm²/s at ambient temperature |
| Accuracy | ±0.01% of reading + ±1 digit |
| Replicate Runs | 1–99 per sample |
| Temperature Equilibration Time | 0–99 min |
| Detection Methods | Dual-mode — Opto-electronic (for transparent/clear liquids) and Thermal Conductivity (TC) sensing (for opaque, dark, or highly viscous samples) |
| Sample Handling | Fully automated liquid handling with programmable injection sequence |
| Interface | RS-232/USB for PC integration |
| Compliance | Designed to meet ASTM D445, ISO 3104, ISO 17025 requirements for accredited viscosity testing laboratories |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | SCI-016 |
| Surface Tension Range | 0–150 mN/m |
| Resolution | < 0.05 mN/m |
| Measurement Method | Wilhelmy Plate (Du Noüy–Wilhelmy) |
| Trough Dimensions | 700 mm × 140 mm |
| Barrier Speed | 10–100 mm/min (infinitely variable) |
| Temperature Control | Dual independent water jackets (30 L pure water tank + 10 L trough jacket), both settable to 35 ± 0.5 °C |
| Power Supply | AC 220 V ± 10 V, 50 Hz, < 150 W |
| Compliance | ASTM D971, ISO 6295, ISO 1409, USP <721>, GLP-ready data logging |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SCI-100E |
| Price | USD 12,000 (FOB Beijing) |
| Measurement Range | 0–1999.999 mN/m |
| Resolution & Sensitivity | 0.001 mN/m |
| Detection Methods | Du Noüy Ring Method, Wilhelmy Plate Method |
| Sampling Interval | 0.1 Hz (standard), 0.02 Hz (optional) |
| Vertical Travel | 0–50 mm (standard), up to 110 mm (optional) |
| Positioning Accuracy | 0.1 µm |
| Force Sensor | High-precision 0.1 mg electromagnetic balance (Mettler Toledo OEM) |
| Temperature Control Support | External thermostatic bath interface (−20 °C to +95 °C, optional) |
| Data Output | Real-time tension curve logging, CSV export, on-device LCD display + thermal printer (integrated) |
| Compliance | SY/T 5370–1999 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SCI-1100 |
| Price Range | USD 14,000–28,000 |
| Instrument Class | High-Temperature Vacuum Contact Angle Measurement System |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Range | 0° < θ < 180° |
| Contact Angle Accuracy | ±1° (θ/2 method), ±0.1° (Circle Fitting Method) |
| Sample Stage Dimensions | Ø14 mm × 10 mm |
| Optical Magnification | 0.7–4.5× |
| Surface/Interfacial Tension Range | 0.01–1000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SCI-1700 |
| Price Range | USD 14,000 – 28,500 |
| Instrument Class | High-Temperature Vacuum Contact Angle Analyzer |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±1° (θ/2 method), ±0.1° (automated circle fitting) |
| Sample Stage Dimensions | 100 × 100 mm |
| Image Magnification | 55–320 pixels/mm |
| Surface/Interfacial Tension Range | 0.01–1000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Maximum Operating Temperature | 1600 °C (in inert atmosphere) |
| Vacuum Limit | ≤5×10⁻⁵ Pa (with turbo-molecular + backing pump configuration) |
| Heating Control | 40-segment programmable PID via B-type thermocouples (Pt/Rh) |
| Temperature Resolution | ±0.1 °C (<1000 °C), ±1 °C (≥1000 °C) |
| Cooling System | Closed-loop water chiller (5–35 °C, 10–20 L/min flow, 1.0–1.3 bar pressure, 1200 W cooling capacity) |
| Optical System | 300-mm working distance telecentric lens, 0.7–4.5× continuous zoom, industrial-grade low-light color CCD (1.3 MP) |
| Software Capabilities | Multi-method contact angle calculation (θ/2, tangent, circle/ellipse/curve fitting), time- and temperature-triggered image capture (min. interval: 0.1 s), left/right asymmetry analysis, automated averaging, GLP-compliant data logging with timestamped image–value pairing and Excel export |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SCI-2000A |
| Price Range | USD 2,800–7,200 |
| Instrument Class | Dynamic Contact Angle Analyzer |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Range | 0° < θ < 180° |
| Contact Angle Accuracy | ±1° (θ/2 method), ±0.1° (circle fitting) |
| Sample Stage Dimensions | 120 × 80 mm |
| Optical Magnification | 0.7×–5× continuous zoom |
| Surface/Interfacial Tension Range | 0.001–1000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SCI300C2 |
| Price Range | USD 14,000 – 28,500 |
| Surface Tension Range | 0–150 mN/m |
| Resolution | 0.05 mN/m |
| Measurement Method | Wilhelmy Plate (ISO 6295, ASTM D971) |
| Trough Material | PTFE (fully fluorinated) |
| Trough Dimensions | 300 mm × 100 mm |
| Compression Ratio | Up to 90% |
| Barrier Speed | 0.48–97 mm/min |
| Deposition Speed | 0.22–45 mm/min |
| Deposition Modes | Upstroke & Downstroke |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | 150 W |
| Operating Temp. | Ambient (compatible with external thermostatic bath) |
| RH Range | 30–85% |
| Optional Configurations | Dual-trough, multi-trough, or custom-area troughs |
| Brand | ScienceEdge |
|---|---|
| Origin | Japan |
| Model | InFocus κ FDTR |
| Dimensions (W×D×H) | 505 × 560 × 480 mm |
| Pump Laser | 445 nm, ~2 μm spot (@20×, NA=0.45) |
| Probe Laser | 514 nm, ~1 μm spot (@20×, NA=0.45) |
| Transducer | Au |
| Modulation Frequency Range | 10 kHz – 50 MHz |
| Sample Types | Thin films, microstructures, particles (e.g., 18 μm single-crystal Al₂O₃), bulk materials |
| Weight | 70 kg |
| Brand | Scienova |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Scienova XDB |
| Dye Method | Colorimetric |
| Removal Method | Solvent-Removable |
| Developer Type | Dry |
| Appearance | Colorless |
| Density | 0.44 g/cm³ |
| Membrane Material | Low-Binding Regenerated Cellulose (Bio-Xell®) |
| MWCO Options | 2, 3.5, 6–8, 12–14, 20, 140 kDa |
| Operating Temperature Range | 1–60 °C |
| pH Stability Range | 5–8 |
| Sterilization | Autoclavable (121 °C, 20 min) |
| Format Compatibility | 96-well microplates, deep-well plates, robotic liquid handlers |
| Brand | SCINCO |
|---|---|
| Origin | USA |
| Model | DSC N-650 |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −150 °C to 725 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Thermocouple Type | Type K |
| Heating/Cooling Rate | 0.1–200 °C/min |
| Baseline Stability | High |
| Heat Flow Sensor Noise Level | Low |
| Cooling Method | Optional Water Cooling |
| Sample Pan Enclosure | Sealed |
| Temperature Control | Dual-PID |
| Brand | Scinco |
|---|---|
| Origin | USA |
| Model | STA N-650/1000/1200/1500 |
| Temperature Range | –125 to 650 °C, RT to 1000/1200/1500 °C |
| Heating/Cooling Rate | 0.1–100 °C/min (N-650), 0.1–40 °C/min (N-1000/N-1200/N-1500) |
| Maximum Sample Mass | 400 mg |
| Temperature Accuracy | ±0.1 °C |
| Mass Accuracy | ±0.1 µg |
| Gas Purge | Integrated automatic gas switching (optional) |
| Furnace Design | Vertical micro-balance architecture with water-cooled furnace |
| Compatibility | FT-IR, Q-MS, and other evolved gas analysis (EGA) systems |
| Brand | Scinco |
|---|---|
| Origin | USA |
| Model | TGA N-1000 / TGA N-1250 / TGA N-1500 |
| Temperature Range | Ambient to 1000°C / 1250°C / 1500°C |
| Balance Sensitivity | 0.1 µg |
| Maximum Sample Mass | 400 mg |
| Heating Rate | 0.1–300 °C/min (N-1000/N-1250) or 0.1–60 °C/min (N-1500) |
| Cooling Method | Water-cooled furnace housing |
| Gas Control | 4-channel automated gas switching valve |
| Simultaneous Analysis Compatibility | FT-IR and Quadrupole Mass Spectrometry (EGA-ready) |
| Sample Capacity | Single-sample vertical configuration |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software |
| Brand | Sciteq |
|---|---|
| Origin | Denmark |
| Model | Sciteq 2000-2 |
| Controller | S40 with 5.7" color touchscreen |
| Cabinet footprint | 800 mm × 800 mm (24″ rack-compatible) |
| Pressure control system | DPCS (Dynamic Pressure Control System) |
| Test modes | Static hydrostatic pressure, burst pressure, cyclic pressure (up to 1 Hz “sawtooth” profile) |
| Remote support capability | Secure Ethernet-based firmware update, diagnostics, and remote desktop access |
| Modular architecture | Supports up to 5 independent pressure stations in base configuration |
| Pressure source | High-pressure axial piston pump + 4 L accumulator |
| Brand | Sciteq |
|---|---|
| Origin | Denmark |
| Instrument Type | Falling Weight Impact Tester |
| Model | B50 |
| Hammer Mass Range | 0.250–16 kg |
| Impact Heights | 2 m, 3 m, 4 m (model-dependent) |
| Compliance | ISO 3127, EN 744, EN 1411, EN 1452, ASTM D2444 |
| Impact Velocity Accuracy | >95% of theoretical free-fall velocity |
| Sample Diameter Range | Ø32 mm to Ø630 mm (customizable beyond) |
| Dimensions (H×W×D) | 4050 × 1800 × 600 mm |
| Weight | ~600 kg |
| Operating Temperature | 5–70 °C |
| Relative Humidity | ≤70% |
| Power Supply | 3 × 400 V AC |
| Compressed Air Requirement | 4–8 bar |
| Hammer Mass Tolerance | ±0.005 kg (per ISO/EN standards) |
| Max. Test Frequency | 15 impacts/min |
| Safety Features | Vacuum-based hammer retention with fail-safe slow descent, interlocked safety door, dual-hand release control, integrated impact velocity monitoring |
| Brand | Sciteq |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sciteq HCP |
| Pricing | Upon Request |
| Brand | Sciteq |
|---|---|
| Origin | Denmark |
| Model | RCP |
| Standard Compliance | ISO 13477 |
| Test Principle | Static Pressurized Impact Initiation of Brittle Fracture in Thermoplastic Pipes |
| Application Scope | Critical Temperature (T<sub>c</sub>) Determination for Rapid Crack Propagation in PE, PP, and Other Pressure Pipes |
| Brand | Sciteq |
|---|---|
| Origin | Denmark |
| Model | TC-micro |
| Configuration Options | TC50 (2ר50 mm or 4ר32 mm) / TC63 (2ר63 mm or 4ר32 mm) |
| Pressure Control | Constant-pressure hydraulic circuit |
| Thermal Range | 5–95 °C (adjustable setpoints) |
| Water Reservoirs | Dual 500 L pressurized tanks (hot & cold) |
| Flow Monitoring | Integrated inline flow sensors per test channel |
| Minimum Flow Velocity | ≥0.5 m/s (automatically maintained) |
| Test Chamber Architecture | Four independent, sealed micro-chambers with individual leak detection |
| Control Interface | 15-inch industrial touchscreen HMI with PLC-based logic |
| Safety Compliance | EN 61000-6-2/6-4, EN ISO 13857, integrated emergency stop circuits |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SCJ-70 |
| Pricing | Available Upon Request |
| Temperature Range | −70 °C to 0 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Display Resolution | 0.1 °C |
| Hammer Blade Radius | 1.6 ± 0.1 mm |
| Impact Velocity | 200 ± 20 cm/s |
| Specimen Dimensions | 20 × 2.5 × 2.5 mm |
| Lower Jaw Arc Radius | 4.0 ± 0.1 mm |
| Clearance Between Blade Outer Edge and Clamp | 2.0 ± 0.1 mm |
| Distance from Impact Point to Clamp Centerline | 3.6 ± 0.1 mm |
| Brand | LANScientific |
|---|---|
| Model | ScopeX PC7 |
| Origin | Jiangsu, China |
| Manufacturer | LANScientific |
| Type | Benchtop ED-XRF Coating Thickness Analyzer |
| Measurement Principle | Energy-Dispersive X-Ray Fluorescence (ED-XRF) |
| Geometry | Bottom-illumination (upward irradiation) |
| Sample Handling | Manual X-Y stage with 25 µm resolution |
| Detection Depth Range | Up to 30 mm in recessed features |
| Optional Configurations | Micro-focus X-ray source, interchangeable collimators (φ0.1 mm to φ2.0 mm), automatic filter wheel (Al, Cu, Ti, Ni, Mo, Sn, Pb) |
| Compliance | Designed for ISO 3497, ASTM B568, ASTM F136, EN 14571, and GB/T 1764–2022 conformance |
| Software | Multi-FP fundamental parameters quantification engine with matrix correction, spectral deconvolution, and GLP-compliant audit trail |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HY-726 |
| Price Range | USD 14,000 – 43,000 |
| Instrument Type | Specialty Flex-Abrasion Fatigue Tester |
| Maximum Test Load | 2000 g |
| Oscillation Frequency | 120 cycles per minute (cpm) |
| Net Weight | 60 kg |
| Specimen Mounting | Single specimen |
| Clamp Width | 45 mm |
| Max Clamp Spacing | 35 mm |
| Stroke Length | Adjustable up to 50 mm |
| Applied Load Range | 0.2–2.0 kg (via calibrated weights) |
| Load Application | Dead-weight loading with incremental mass sets |
| Display | 6-digit LCD digital counter |
| Power Supply | AC 220 V, 50 Hz |
| Brand | SDL Atlas |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | M233G |
| Price Range | USD 14,000 – 28,000 |
| Application Field | Textiles & Home Furnishings |
| Test Angle | 45° |
| Flame Exposure Duration Options | 1 s, 5 s, 20 s |
| Timing Resolution | 0.1 s |
| Construction | Stainless Steel Chamber with Tempered Glass Viewing Window |
| Optional Accessory | Nylon Brush Kit |
| Brand | SDL Atlas |
|---|---|
| Model | M233M |
| Test Orientation | Vertical |
| Construction | Stainless Steel Combustion Chamber with Tempered Glass Viewing Window |
| Burner Type | Standard ASTM/ISO-Compliant Bunsen Burner |
| Gas Control | Manual or Optional Electromagnetic Solenoid Valve with Auto-Ignition and Timer Control |
| Sample Holder | Interchangeable Fixtures per Standard (e.g., ASTM D6413, ISO 6941, GB/T 5455, NFPA 701) |
| Compliance | Designed for Textile and Home Furnishing Flammability Testing |