| Brand | SEARCHING |
|---|---|
| Origin | Shandong, China |
| Model | CHY-G |
| Measurement Range | 0–12.7 mm |
| Resolution | 0.001 mm |
| Sample Diameter | 5–300 mm (customizable) |
| Sample Height | 5–330 mm (customizable) |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions | 400 × 360 × 700 mm (L×W×H) |
| Display | 7-inch color touchscreen LCD |
| Data Output | Built-in thermal printer, USB interface, PC software support (Excel export, curve plotting, audit-trail-capable user permission management) |
| Brand | SEARCHING |
|---|---|
| Origin | Shandong, China |
| Model | ZRD-T1 |
| Measurement Range | 10–1000 mN |
| Resolution | 0.01 mN |
| Indication Error | ±1% (±1 mN for values <20% of full scale) |
| Repeatability Error | <3% (±1 mN for values <20% of full scale) |
| Probe Total Travel | 12 ±0.5 mm |
| Probe Penetration Depth | 8 ±0.5 mm |
| Slit Width Options | 5 mm, 6.35 mm, 10 mm, 20 mm |
| Slit Width Tolerance | ±0.05 mm |
| Slit Parallelism Error | ≤0.05 mm |
| Probe Alignment Error | ≤0.05 mm |
| Motor | Permanent-magnet low-speed synchronous motor (4 r/min, 220 V) |
| Dimensions | 240 × 300 × 280 mm (L×W×H) |
| Net Weight | ~15 kg |
| Compliance | GB/T 8942–2016, QB/T 1016, JIS Z 0237 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | -65°C to +180°C |
| Thermal Transition Time | ≤15 s (typical between chambers) |
| Control System | TEMI880 Color Touchscreen Controller (English/Chinese Switchable) or TEMI300 Membrane Keypad Controller (English Only) |
| Refrigeration | Twin-Stage or Single-Stage Hermetic Compressor (Original Tecumseh or Copeland) |
| Insulation | Rigid Polyurethane Foam (≥100 mm) + Ultra-Fine Glass Fiber |
| Interior Material | SUS304 Stainless Steel |
| Exterior Finish | Electrostatic Powder-Coated Cold-Rolled Steel or Optional Brushed SUS304 |
| Air Circulation | Wide-Band Forced Convection with Centrifugal Blower |
| Compliance | ASTM D5229, MIL-STD-883 Method 1010, JESD22-A104, IEC 60068-2-14 |
| Brand | Semrock |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Semrock |
| Pricing | Upon Request |
| Brand | Semrock |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | VersaChrome® TBP01 Series |
| Pricing | Available Upon Request |
| Brand | Senbe |
|---|---|
| Model | A650 |
| Type | Benchtop Energy-Dispersive X-ray Fluorescence (EDXRF) Spectrometer |
| Detector | Silicon Drift Detector (SDD), Resolution: 129 ± 5 eV |
| X-ray Tube | 50 W, 5–50 kV / 0–1000 µA |
| Measurable Elements | Na (11) to U (92) |
| Detection Limit | ppm-level |
| Quantification Range | 0.0001% – 99.99% (matrix-dependent) |
| Sample Form | Solid, Powder, Liquid |
| Vacuum Capability | Integrated Vacuum System for Light Element Enhancement (Mg, Al, Si, P, S) |
| Cooling | Peltier-based Electric Refrigeration |
| Safety | Triple-layer Radiation Shielding, Interlocked Sample Chamber, Real-time Beam Monitoring |
| Software | Proprietary EDXRF Analysis Suite with Fundamental Parameters (FP), Empirical Coefficient, and Matrix Correction Algorithms |
| Compliance | Designed to meet IEC 61000-6-3 (EMC), IEC 61000-6-4, and GB/T 18806–2002 (Chinese EDXRF Standard) |
| Brand | Senbe |
|---|---|
| Model | T300S |
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Detector | Si-Pin Semiconductor |
| Measurable Elements | S (16) to U (92) |
| X-ray Tube Voltage | 0–50 kV (intelligent programmable HV system) |
| Collimator | Standard Φ0.5 mm |
| Optical Magnification | 30× (industrial CCD camera) |
| Energy Resolution | ≤129 eV ±5 eV |
| Analysis Layers | Up to 5 simultaneous layers |
| Analyzable Elements per Measurement | Up to 24 |
| Algorithm | Fundamental Parameters (FP) method |
| Signal Processing | Digital Multi-Channel Analyzer (MCA) technology |
| Chamber Dimensions | 268 × 307 × 97 mm |
| Overall Dimensions | 414 × 416 × 362 mm |
| Safety Systems | Multi-dimensional thermal dissipation + dual interlock radiation shielding + real-time hardware status monitoring |
| Brand | Auniontech (Hao Liang Optoelectronics) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model Designation | Gaussmeter / Teslameter |
| Pricing | Available Upon Request |
| Brand | SEPHA |
|---|---|
| Origin | United Kingdom |
| Model | Multi-Q HD |
| Detection Principle | Vacuum Decay Method (ASTM F2338-09) |
| Compliance | USP <1207>, FDA-recognized CCIT method |
| Minimum Detectable Leak | ≥1 µm |
| Sensor Type | High-resolution absolute pressure transducer with localized in-chamber placement |
| Test Cycle Time | Optimized for high-throughput QC environments |
| Intended Use | Sterile parenteral packaging (vials, syringes, cartridges, blow-fill-seal containers) |
| Regulatory Context | Supports 21 CFR Part 11-compliant data integrity requirements when integrated with validated software |
| Brand | SEPHA |
|---|---|
| Country of Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VisionScan 3D |
| Pricing | Upon Request |
| Brand | SINOTEST |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | SZL |
| Instrument Category | Electromechanical Fatigue Testing System |
| Pricing | Available Upon Request |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | SA1800-2 |
| Instrument Type | Optical Particle Counter |
| Compliant Standards | ASTM D975, ASTM D6786, ASTM D7619, IP 565, IP 630, NB/SH/T 0868, JIS B 9932:2012, JIS B 9933:2021, JIS B 9934:2012, GB/T 5930 |
| Measurement Principle | Light Obscuration (LO) |
| Sample Throughput | ≤3 min per test |
| Display | Integrated graphical interface with trend visualization |
| Data Interface | USB port for export |
| Onboard Functions | Built-in thermal printer, three pre-programmed test methods, PC-configurable via Partikel software |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | SA1900-0 |
| Instrument Type | Optical Particle Counter |
| Compliance Standards | IP 565, NB/SH/T 0868, ASTM D7647, ISO 4406, ISO 60970, ASTM D6786, NAS 1638, AS 4059F, ISO 11171, ISO 11500, SAE J183, SAE J749D, GOST 17216, GB/T 5930, GJB 420A–1996, GJB 420B–2006, JIS B 9932:2012, JIS B 9933:2021, JIS B 9934:2012 |
| Sample Viscosity Range | Up to 400 cSt (tested with in-service lubricants, hydraulic fluids, and insulating oils) |
| Sealing Material | FFKM (perfluoroelastomer) |
| Integrated Pressure Pump | Yes |
| Analysis Time | ≤ 3 minutes per sample |
| Control Modes | Standalone operation or PC-controlled via ProTrend software |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | SA1100-0 |
| Instrument Type | Optical Particle Counter |
| Particle Size Range (ISO 11171) | 4 µm to >70 µm |
| Particle Size Range (ISO 4402) | 2 µm to >100 µm |
| Number of Sizing Channels | 16 |
| Maximum Particle Count per Test | 60,000 particles/mL |
| Sample Viscosity Range | up to 68 mm²/s (direct from bottle), up to 500 mm²/s at 10 bar |
| Sample Temperature Range | 0–70 °C |
| Flow Rate | 30 mL/min |
| Total Sample Volume per Test | 80 mL (including rinse) for IP 565 |
| Maximum Inlet Pressure | 10 bar (310 bar optional) |
| Output Units | particles/mL or particles/10 mL |
| Cleanliness Codes | Cumulative & Differential per ISO 4406, NAS 1638, SAE AS4059, JIS B 9932:2012, JIS B 9933:2021, JIS B 9934:2012, GOST 17216, Defence Standards 91-091 & 91-86, ASTM D975, D6299, D7619, D7647, IP 565, IP 630 |
| Calibration Standard | ISO 11171 |
| Data Interfaces | Ethernet, USB |
| Display | Integrated touchscreen interface |
| Onboard SQC Software | Compliant with ASTM D6299 statistical quality control requirements |
| User Authentication | Password-protected access levels |
| Embedded Test Methods | 14 preconfigured methods |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | 96 Line |
| Temperature Range | RT to 1750 °C (upgradable to 2100 °C) |
| Heating Rate | 0–100 K/min |
| TG Sample Capacity | 100 g |
| Max. TG Sample Dimensions | Ø20 mm × H80 mm |
| TG Resolution | 0.3 µg |
| Calorimetric Sample Volume | 5700 µL (Ø14.5 mm × H35 mm) |
| Specific Heat Accuracy | ±1% (relative) |
| TMA Stroke Range | ±6 mm |
| TMA Resolution | 1.6 nm |
| TMA Max. Sample Dimensions | Ø18 mm × H50 mm |
| Sensor Architecture | 3D microcalorimetric sensor with Drop method implementation |
| Modular Configurations | TG, TG-DSC, TG-DTA, TMA, 3D calorimetry |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | 96line High-Temperature Specific Heat Analyzer |
| Temperature Range | Ambient to 2000 °C |
| Temperature Accuracy | ±0.5 °C (typical for high-temperature DSC-grade calibration) |
| Heating/Cooling Rate | 0.001–99 K/min |
| Sample Capacity (Calorimetry) | 5.7 mL (Ø14.5 mm × H35 mm) |
| Specific Heat Measurement Uncertainty | ≤1% (per ASTM E1269 & ISO 11357-4) |
| TGA Max Load | 100 g |
| TGA Resolution | 0.3 µg |
| TMA Range | ±6 mm |
| TMA Resolution | 1.6 nm |
| Modular Configurations | Simultaneous TG-DSC, TG-DTA, TMA, 3D Heat-Flow Calorimetry |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | 96line TMA |
| Instrument Type | Thermomechanical Analyzer |
| Temperature Range | Ambient to 2100 °C |
| Displacement Range | ±2 mm |
| Maximum Force | 1.5 N (electromagnetically controlled) |
| Sample Dimensions | L = 50 mm, Ø = 18 mm (recommended Ø = 15 mm) |
| Displacement Resolution | 1.6 nm RMS |
| Displacement Noise | 10 nm RMS |
| Specific Noise | 0.2 × 10⁻⁶ |
| Probe Types | Al₂O₃ (up to 1750 °C), Graphite (≥1750 °C) |
| Probe Geometry | Spherical-tip compression probe |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Alexsys 800 / Alexsys 1000 |
| Calorimetry Principle | Isothermal Heat-Flow Calvet |
| Temperature Range | 500–800 °C (Alexsys 800) / 800–1000 °C (Alexsys 1000) |
| Sample Crucible Count | 2 |
| Crucible Volume | 28 mL / 20 mL (dual configuration) |
| Temperature Accuracy | ±0.1% of reading |
| Calorimetric Accuracy | ±1% |
| Heat Flow Resolution | 12.5 µW |
| Dimensions (W × H) | 800 mm × 880 mm |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | BT2.15 |
| Temperature Range | –196 to +200 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.01–1 K/min |
| Detection Principle | 3D Calvet-type Heat Flow Calorimetry |
| Operating Modes | Isothermal & Non-Isothermal |
| Sample Environment | Open or Controlled-Atmosphere (including pressurized & mixing cells) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | C600 |
| Temperature Range | Ambient to 600 °C |
| Heating Rate | 0.01–2.000 °C/min |
| Calorimetric Resolution | 0.1 µW |
| Isothermal Stability (40 °C) | ±0.001 °C |
| Temperature Accuracy | ±0.1 °C |
| Calorimetric Accuracy | ±0.1% |
| Enthalpy Accuracy | ±1% |
| Reaction Cell Volume | 8.5–12.5 mL |
| RMS Noise | 1 µW |
| Sensitivity (Joule Effect at 30 °C) | 30 µW/mW |
| Dynamic Range | ±660 mW / ±2000 mW |
| Pressure Capability | Up to 1000 bar (14,500 psi) |
| Sample Form | Solid, Liquid, Powder, Thin Film, or Fiber |
| Dimensions (H×W×D) | 60×25×31 cm |
| Weight | 30 kg |
| Power Supply | 230 V, 50/60 Hz |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | C80 |
| Temperature Range | Ambient to 300 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.05 °C |
| Heating/Cooling Rate | 0.001–2 K/min |
| Enthalpy Accuracy | ±1% |
| Calorimetric Precision | ±0.1% |
| Heat Flow Resolution | 0.10 µW |
| Maximum Sample Volume | 12.5 mL |
| Pressure Rating | Up to 1000 bar |
| Sensor Type | 3D Calvet Thermopile Array |
| Sample Cell Materials | Stainless Steel, Hastelloy C, or Custom Alloys |
| Cell Types | Ampoule, Flip-Mix, Membrane-Mix, Fluid Circulation, Liquid Heat Capacity, Vacuum, Adsorption, High-Pressure Pressure-Monitoring, and Safety Cells |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | C80 |
| Operating Modes | Isothermal & Scanning |
| Temperature Range | Ambient to 300 °C |
| Heating Rate | 0.001–2 °C/min |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.05 °C |
| Enthalpy Accuracy | ±1% |
| Calorimetric Precision | ±0.1% |
| Heat Flow Resolution | 0.10 µW |
| Maximum Sample Volume | 12.5 mL |
| Cell Materials | Stainless Steel or Hastelloy C |
| Maximum Pressure Rating | 1000 bar |
| Cell Types | Ampoule, Flip-Mix, Membrane-Mix, Fluid Circulation, Liquid Heat Capacity, Vacuum, Adsorption, High-Pressure Manometric, Safety Cells |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | C80 Microcalorimeter |
| Temperature Range | Ambient to 300 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.001–2 K/min |
| Calorimetric Resolution | 0.10 µW |
| Maximum Sample Volume | 12.5 mL |
| Maximum Pressure Rating | 1000 bar |
| Sensor Principle | Calvet-type 3D-sensor |
| Thermal Enthalpy Accuracy | ±1% |
| Calorimetric Accuracy | ±0.1% |
| Temperature Precision | ±0.05 °C |
| Sample Cell Materials | Stainless Steel or Hastelloy C |
| Operating Modes | Isothermal and Scanning |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | CALVET C80 |
| Measurement Principle | 3D Heat-Flow Calorimetry (Calvet-type) |
| Temperature Range | Ambient to 300 °C |
| Temperature Precision | ±0.15 °C |
| Sample Capacity | Microscale (µg–mg range) |
| Operating Modes | Isothermal & Temperature-Scanning |
| Pressure Capability | Up to 1000 bar (with custom cells) |
| Vacuum Compatibility | Yes |
| Gas/Liquid Flow Integration | Yes |
| Compliance | ASTM E698, ISO 11357-4, USP <1031>, GLP/GMP-ready data audit trail (via C80 software) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Calvet CRYO |
| Instrument Type | Reaction Calorimeter |
| Measurement Mode | Heat Flow (3D Calvet Principle) |
| Temperature Range | –196 °C to 200 °C |
| Temperature Resolution | 0.1 μW (heat flow resolution) |
| Sample Environment | Vacuum-jacketed, configurable for high pressure (up to 1000 bar), vacuum, inert gas, or reactive atmospheres |
| Sensor Architecture | Dual cylindrical thermopile arrays (480 thermocouples per array), fully surrounding sample and reference zones |
| Compliance | Designed for GLP/GMP environments |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | CALVET HT |
| Temperature Range | RT to 600 °C |
| Temperature Precision | ±0.5 °C |
| Measurement Principle | 3D Symmetrical Heat-Flow Calorimetry |
| Maximum Operating Pressure | 400 bar |
| Sample Configuration | Customizable high-pressure, vacuum-compatible, stirred, or gas-flow-integrated cells |
| Cooling | External recirculating water bath |
| Compliance | Designed for GLP/GMP-aligned workflows and ASTM E698, ISO 11358, and UN Test Series 3 compatibility |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Calvet HT (formerly C600) |
| Instrument Type | Reaction Calorimeter |
| Measurement Mode | 3D Calvet Calorimetry |
| Temperature Range | Ambient to 600 °C |
| Temperature Resolution | 0.5 μW (heat flow resolution) |
| Pressure Capability | Up to 400 bar |
| Sample Configuration | Dual-zone 3D thermopile sensor array |
| Compliance | Designed for GLP/GMP environments, compatible with ASTM E698, ISO 11357-4, and USP <1031> thermal stability protocols |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Calvet LV |
| Instrument Type | Reaction Calorimeter |
| Measurement Mode | Isothermal |
| Temperature Range | Ambient to 200 °C |
| Sample Capacity | Up to 100 mL (e.g., two D-cell batteries) |
| Sensor Architecture | 2- or 4-channel 3D Calvet thermopile (up to 1,316 thermocouples per stack) |
| Pressure Capability | Up to 350 bar |
| Vacuum Compatibility | High vacuum |
| Optional Functions | In-situ stirring, gas flow control, electrochemical cycling (battery charge/discharge), pressure regulation & monitoring |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Calvet Pro |
| Instrument Type | Reaction Calorimeter |
| Measurement Principle | 3D Calvet-type Heat-Flow Calorimetry |
| Sample Mass Range | mg-scale |
| Temperature Range | –120 °C to 830 °C |
| Pressure Capability | Up to 500 bar (with optional high-pressure module) |
| Vacuum Compatibility | Yes |
| Cp Accuracy | High-precision absolute heat capacity measurement |
| Operating Modes | Isothermal, Dynamic Scanning, and Stepwise Temperature Programs |
| Sensor Architecture | Symmetric 3D thermopile array surrounding the sample and reference positions |
| Calibration Method | Joule-effect electrical calibration |
| Sample Environment Control | Integrated pressure regulation, monitoring, and control |
| Brand | SETARAM |
|---|---|
| Origin | USA |
| Model | CryoPro-2009 |
| Operating Temperature Range | –269 °C to 100 °C |
| Pressure Range | Vacuum to 200 bar (3000 psi / 100 psi dual-range transducers) |
| Cooling Medium | Liquid Helium or Liquid Nitrogen |
| Construction Material | 316 Stainless Steel |
| Sealing Method | Metal-Gasketed Arc-Welded Joints |
| Control System | LabVIEW-Based Automated Platform |
| Safety Features | Integrated Hydrogen Leak Detection and Flame Suppression System |
| Compliance | Designed for GLP/GMP-aligned workflows with full audit trail capability |