Physical Property Testing Instruments
Filter
Showing 9661–9690 of 12279 results
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | DRC |
| Type | Laboratory-scale differential reaction calorimeter with dual-jacketed vessels, isothermal operation mode, and real-time ΔT monitoring via platinum resistance thermometers |
| Measurement Principle | Differential temperature-based heat flow quantification using Joule-effect calibration |
| Key Outputs | Reaction enthalpy (ΔHᵣₓₙ), mixing enthalpy (ΔHₘᵢₓ), adiabatic temperature rise (ΔTₐd), time-to-maximum-rate (tₘₐₓ), heat capacity (Cₚ), kinetic profiling |
| Compliance | Designed for GLP-compliant thermal safety assessment per ISO 11358, ASTM E698, and ICH Q1A(R2) guidelines |
| Software | CALISTO™ v5.0 with 21 CFR Part 11–compliant audit trail, raw data export (CSV, ASCII), and customizable reporting templates |
| Sample Compatibility | Liquid–liquid, liquid–gas, and heterogeneous slurries (max. working volume: 500 mL per vessel) |
| Temperature Control | Dual-circulating bath integration (±0.02 °C stability) |
| Sensor Resolution | ±0.001 °C ΔT detection limit |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | DRC evo |
| Type | Benchtop Differential Reaction Calorimeter |
| Operating Principle | Isothermal Micro-Differential Calorimetry (Based on Dual-Bath Temperature Difference Measurement) |
| Temperature Control | Dual Jacketed Reactor Vessels with External Circulating Bath |
| Detection | High-Precision Pt100 Differential Thermometry |
| Data Output | ΔT vs. t, Q vs. t, dQ/dt vs. t |
| Compliance | Designed for GLP/GMP-aligned thermal safety screening per ASTM E698, ISO 11358, and ICH Q1A(R2) guidance |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | DSC131 Evo |
| Temperature Range | −170 to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.05 °C |
| Enthalpy Accuracy | ±2% |
| Heat Flow Precision | ±0.5% |
| Noise Level (at 200 °C) | 1.5 μW |
| Sensitivity (Indium Fusion) | 3 μV/mW |
| Dynamic Heat Flow Range | ±6000 mW |
| Time Constant | 3 s |
| Gas Control | Dual-gas switching capability |
| Pressure Rating (uncontrolled) | up to 500 bar (7255 psi) at 600 °C |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | DSC131 Evo |
| Temperature Range | −170 to 700 °C (LN₂ mode) / −80 to 500 °C (mechanical cooling) |
| Heating/Cooling Rate | 0–100 K/min |
| Dynamic Heat Flow Range | ±6000 mW |
| Gas Channels | 2 independent, software-controlled carrier gas lines |
| Pressure Rating | up to 500 bar with high-pressure crucibles |
| Sensor Type | removable heat-flux DSC sensor |
| Standard Software | CALISTO v5.x |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Flexi WET200 |
| Instrument Type | Humidity Generator |
| Temperature Range | Ambient to 70 °C |
| Relative Humidity Range | 5–95% RH |
| Gas Flow Rate | 20–50 mL/min |
| Humidity Stability | ±0.3% RH |
| Compatible Gases | He, Air, Ar, N₂, CO₂ |
| Heating Stem Temperature | Ambient to 85 °C |
| Control System | Eurotherm-based PID loop with integrated RH, T, and flow feedback |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | GASPRO |
| Measurement Principle | Sievert-type Volumetric Method |
| Temperature Range | –260 °C to 500 °C (customizable beyond) |
| Pressure Range | Vacuum to 200 bar |
| Ultimate Vacuum | Two-stage vacuum system |
| Pressure Sensing | Dual-sensor architecture — high-pressure sensor (vacuum–200 bar, < 0.025 % FS accuracy), low-pressure sensor (vacuum–15 bar, < 0.12 % RD accuracy) |
| Minimum Detectable Uptake | 3 μmol (with Microdoser option) |
| Sample Mass Capability | Down to < 100 mg (patented US8132476 Microdoser) |
| Calibration Volumes | 5 pre-calibrated buffer volumes (5 mL to 1.2 L) |
| Gas Compatibility | CO₂, CH₄, N₂, Ar, H₂, He, and other non-corrosive gases |
| Safety Systems | Combustible gas detection, emergency pressure relief port |
| Control Modes | Isothermal PCT, adsorption/desorption kinetics, cyclic stability testing |
| Software Compliance | Audit-trail enabled, 21 CFR Part 11 ready (optional), GLP/GMP-supporting data integrity framework |
| Key | Origin: France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | HT1000 |
| Pricing | Available Upon Request |
| Temperature Range | Ambient to 1000 °C |
| Sample Crucible Volume | 8.5 mL |
| Heat Flow Resolution | 4 µW |
| Baseline Noise | 8 µW |
| Crucible Types | Standard Crucible, Solid Specific Heat Crucible, Joule Calibration Crucible |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Labsys Evo Cp |
| Temperature Range | Ambient to 1600 °C (single furnace) |
| Heating/Cooling Rate | 0.01–100 K/min |
| Balance Max Load | 20 g |
| Balance Range | ±1000 mg |
| Balance Resolution | 0.02 µg |
| DSC Sensitivity | 0.4 µW (sensor-dependent) |
| Cp Measurement Uncertainty | <2% |
| Atmosphere Options | Inert, Oxidizing, Reducing, Static, Dynamic, Vacuum |
| Gas Control | 3 Mass-Flow-Controlled Carrier Gases + 1 Auxiliary/Reaction Gas |
| Optional Autosampler (ASC) | Up to 25 Positions |
| EGA Compatibility | Direct Coupling to MS, FT-IR, GC |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Labsys Evo STA |
| Heating Rate | 0–100 K/min |
| Temperature Range | Ambient to 1600 °C |
| Temperature Stability | ±0.05 °C |
| Maximum Sample Mass | 1000 mg |
| Atmosphere Compatibility | Inert, Oxidizing, Reducing, Steam, Corrosive Gases |
| Balance Resolution | 0.02 µg |
| DSC Sensitivity | 0.4 µW (sensor-dependent) |
| Cp Accuracy | <2% error |
| Gas Control | 3 mass-flow-controlled carrier gases + 1 auxiliary/reactive gas |
| EGA Interface | Standard MS/FT-IR/GC coupling ports |
| Optional Autosampler | 25-position ASC |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Labsys Evo-DSC |
| Temperature Range | Ambient to 1600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.01–100 K/min |
| Balance Max Capacity | 20 g |
| Balance Range | ±1000 mg |
| Balance Resolution | 0.02 µg |
| DSC Sensitivity | 0.4 µW (sensor-dependent) |
| Cp Measurement Uncertainty | <2% |
| Atmosphere Options | Inert, Oxidizing, Reducing, Static, Dynamic, Vacuum |
| Gas Control | 3 Mass-Flow-Controlled Carrier Gases + 1 Auxiliary/Reaction Gas |
| EGA Compatibility | MS, FT-IR, GC |
| Optional Autosampler | 25-position ASC |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | Labsys Evo-TGA |
| Temperature Range | RT–1600 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 0.02 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | MICRO DSC7 |
| Temperature Range | −45 °C to 120 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.001–2 K/min |
| Sample Cell Volume | 450 µL (intermittent mode) |
| Baseline Noise (RMS) | 0.4 µW |
| Minimum Detectable Heat Flow | 0.002 µW |
| Maximum Controllable Pressure | 1000 bar |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Microcalvet |
| Instrument Type | Reaction Calorimeter |
| Measurement Principle | 3D Calorimetric Sensor with Joule Calibration |
| Temperature Range | −45 °C to 120 °C |
| Accuracy | ±0.15% |
| Sample Capacity | Variable (micro-to-milligram scale) |
| Pressure Capability | Up to 1000 bar (with optional high-pressure cells) |
| Compatibility | Vacuum, inert atmosphere, reactive gas environments |
| Thermal Control | Peltier-based 3-axis symmetric heating/cooling |
| Interface | Modular coupling with BET analyzers, gas sorption systems, humidity generators, and high-pressure gas controllers |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Microcalvet Ultra |
| Instrument Type | Reaction Calorimeter |
| Measurement Mode | Isothermal & Scanning Calorimetry |
| Temperature Range | –20 °C to 170 °C |
| Sensitivity | Sub-microwatt (µW) thermal power resolution |
| Sample Environment | Compatible with high-pressure (up to 400 bar), vacuum, gas-controlled, and stirred/mixed configurations |
| Interfacing Capability | Integrated coupling with BET surface analyzers, physicochemical adsorption systems, humidity generators, and high-pressure/vacuum gas controllers |
| Calibration Method | Joule calibration with 3D Calvet sensor architecture |
| Sample Cell Options | Interchangeable, chemically resistant, easy-clean crucibles for solids, powders, gels, liquids, and slurries |
| Compliance | Designed for GLP/GMP environments |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MS80 |
| Pricing | Upon Request |
| Temperature Range | Ambient to 200 °C |
| Sample Cell Volume | 12.5 mL |
| Heat Flow Resolution | 0.08 µW |
| Baseline Noise | 0.1 µW |
| Configurations | 2-cell or 4-cell dual-isothermal design |
| Compatible Cell Types | Standard, Vacuum, Gas-Circulation, Liquid Heat Capacity, Solid Heat Capacity, Joule Calibration, and Mixing Cells |
| Brand | SETARAM |
|---|---|
| Origin | USA |
| Model | PCT Pro E&E |
| Instrument Type | Physical & Chemical Sorption Analyzer |
| Temperature Range | –269 °C to 500 °C |
| Pressure Range | Vacuum to 200 bar |
| Pressure Accuracy | ±1% FS |
| Detection Limit | 3 µg (equivalent to 0.3 wt% gas uptake on 1 mg sample) |
| Integrated Pressure Sensors | 4 (auto-switching dual-range) |
| Gas Compatibility | H₂, CO₂, CH₄, NH₃ |
| Sample Cell Options | 6 types (standard, high-temp, liquid, thin-film, cryogenic, micro-dosing) |
| Safety Systems | Combustible gas detection, multi-point T/P monitoring, inert-gas purged transfer pathway |
| Software Platform | LabVIEW-based with real-time data acquisition, automated sequence execution, and audit-trail-capable operation |
| Brand | Setaram |
|---|---|
| Origin | USA |
| Model | PCTPro-Evo |
| Temperature Range | –269 °C to 500 °C |
| Pressure Range | Vacuum to 200 bar |
| Pressure Accuracy | ±1% |
| Detection Limit | 3 µg (equivalent to 0.3 wt% gas uptake on 1 mg sample) |
| Gas Compatibility | H₂ only |
| Sensor Configuration | Four auto-switching pressure transducers with dual-range capability |
| Sample Cell Options | Six interchangeable cells (standard, high-temperature, liquid, thin-film, cryogenic, micro-dosing) |
| Safety Systems | Integrated combustible gas detection, multi-point temperature/pressure monitoring, inert-gas purged transfer pathway |
| Software Platform | LabVIEW-based real-time control and analysis suite |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Sensys DSC High-Pressure Calvet Microcalorimeter |
| Temperature Range | −120 to +830 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.01–30 K/min |
| Maximum Pressure | 500 bar at 600 °C |
| Pressure Monitoring Limit | 400 bar at 600 °C |
| DSC Sample Volume | up to 320 μL |
| DSC Detection Limit | 5 μW |
| DSC Resolution | 0.4 μW |
| TGA Max Sample Mass | 35 g |
| TGA Resolution | 0.03 μg |
| Gas Lines | 3 carrier + 1 reactive/auxiliary |
| Atmosphere Compatibility | Oxidizing, reducing (H₂, CO), corrosive (H₂S, NH₃), steam |
| Auto-sampler Capacity | 48 positions |
| Software | Calisto v5.x with Cp measurement module |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | Sensys Evo TG-DSC |
| Temperature Range | –120 to 830 °C |
| Heating/Cooling Rate | 0.01–30 °C/min |
| Temperature Stability | ±0.02 °C |
| Max Sample Mass | 3 g |
| Pressure Range (HP-DSC) | up to 500 bar (controlled up to 400 bar) |
| Atmosphere Compatibility | inert, oxidizing, reducing, corrosive (e.g., H₂S, NH₃), humidified, vacuum, steam |
| Balance Resolution | 0.002 µg |
| DSC Sensitivity | < 0.035 µW |
| TG Baseline Drift | < 10 µg (full-scale scan) |
| TG Baseline Repeatability | ±1 µg |
| Gas Control | integrated mass flow controllers, 3 carrier + 1 reactive gas channels |
| Sample Holder Options | TG-DSC and TG-DTA dual-mode crucibles |
| Optional Features | ASC auto-sampler (48 positions), humidity control module, FT-IR/MS/GC coupling interfaces |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | Sensys Evolution |
| Temperature Range | –120 to 830 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.01–30 °C/min |
| Mass Range | 3000 mg |
| Vacuum Level | <10⁻¹ mbar |
| TG Resolution | 0.002 µg |
| Atmosphere Options | Inert, Oxidizing, Reducing, Static/Dynamic, Vacuum, Corrosive (e.g., H₂S, NH₃), Humidified Steam |
| Gas Control | Integrated 3-channel mass flow controller (2 carrier + 1 reactive gas), programmable mixing ratio (1:99 to 50:50) |
| TG Baseline Drift | <10 µg over full scan |
| TG Baseline Repeatability | ±1 µg |
| Evolved Gas Analysis Compatibility | MS, FT-IR, GC |
| Optional Autosampler | 48-position ASC |
| Thermal Stability | ±0.001 to ±0.00001 °C (isothermal) |
| Sample Chamber Volume | 320 µL |
| Sensor Architecture | Calvet-type 3D thermopile sensor |
| Software | Calisto v6.x (21 CFR Part 11 compliant, GLP/GMP audit trail enabled) |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | Sensys Evolution |
| Temperature Range | -120 to +830 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.01–30 K/min |
| Maximum Sample Cell Pressure | 500 bar (at 600 °C) |
| Pressure Monitoring Range | Up to 400 bar (at 600 °C) |
| DSC Detection Limit | 5 µW |
| DSC Resolution | 0.4 µW |
| Sample Volume Capacity | 250 µL (up to 320 µL with extended cell) |
| TG Compatibility | Yes (up to 35 g sample, 0.03 µg resolution) |
| Atmosphere Options | Oxidizing, reducing (H₂, CO), corrosive (H₂S, NH₃), steam, mixed gases (1–99% ratio) |
| Autosampler | 48-position |
| Software | Calisto v5.x (GLP-compliant, audit trail enabled) |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | Sensys-evo |
| Instrument Type | High-Pressure Chemisorption Calorimeter |
| Temperature Range | −120 to +830 °C |
| Temperature Repeatability | ±0.1% |
| Programmable Scan Rate | 0.01–30 °C/min |
| Heat Flow Resolution | 0.4 μW |
| Detection Limit | 5 μW |
| Maximum Sample Cell Pressure | 500 bar at 600 °C |
| Controlled/Measured Pressure Range | up to 400 bar at 600 °C |
| Sample Chamber Volume | 250 μL |
| Gas Channels | 3 carrier + 1 reactive/auxiliary |
| Atmosphere Compatibility | oxidizing, reducing (H₂, CO), corrosive (H₂S, NH₃), steam |
| Automated Sampler Capacity | 48 positions |
| Optional Coupling | TGA (35 g max, 0.03 μg resolution), FT-IR, MS, GC, humidity controller |
| Brand | Setaram |
|---|---|
| Origin | Beijing, China (jointly developed by Chinese, French & Swiss teams) |
| Model | Setline DSC |
| Temperature Range | −170 to 700 °C |
| Programmable Heating/Cooling Rate | 0.01–100 °C/min |
| Temperature Accuracy | ±0.1 °C (vs. standard metals) |
| Temperature Precision | ±0.05 °C |
| DSC Signal Range | ±6000 mW |
| Heat Flow Resolution | 0.1 µW |
| Temperature Stability | ±0.1 °C (standard metal) |
| Sample Capacity | Single-position |
| Cooling Options | Manual/auto liquid nitrogen (−170 to 400 °C), He/Ar/dry air gas-cooling (−70 to 400 °C) |
| Gas Control | Dual-channel programmable gas switching |
| Software | Calisto 2.0 (data acquisition & processing with audit trail, user permissions, macro automation, Cp calculation) |
| Brand | SETARAM |
|---|---|
| Origin | Beijing, China (Manufactured under French R&D supervision) |
| Model | Setline DSC+ |
| Temperature Range | −170 °C to 700 °C |
| Temperature Accuracy | ±0.1 °C (vs. certified standards) |
| Heating/Cooling Rate | 0.01–100 K/min |
| Heat Flow Resolution | 0.1 µW |
| Heat Flow Range | ±6000 mW |
| Calorimetric Accuracy | ±0.8% (vs. standard metals) |
| Calorimetric Precision | ±0.1% |
| Atmosphere Control | Dual independent gas flow channels with software-programmed auto-switching |
| Sensor Type | Flat-plate NiCr–Constantan thermopile |
| Cooling Options | Manual/automated LN₂ (−170 °C to 400 °C), He gas cryo-cooling (−70 °C to 200 °C), dry air/N₂/Ar (−50 °C to 400 °C) |
| Crucible Options | Al₂O₃, Al (30 & 100 µL), Incoloy high-pressure (30 µL, up to 500 bar at 600 °C), 316L stainless steel (optional) |
| Brand | SETARAM |
|---|---|
| Origin | Beijing, China (Manufactured under France-China joint development) |
| Model | Setline TGA |
| Temperature Range | Ambient to 1100 °C |
| Temperature Accuracy | ±0.3 K |
| Temperature Precision | ±0.1 °C |
| Heating/Cooling Rate | 0.01–50 K/min |
| Dynamic Mass Range | ±20 mg / ±200 mg |
| Balance Sensitivity | 0.0023 µg |
| Mass Accuracy | 0.01% |
| Mass Precision | 0.005% |
| Maximum Sample Mass | 0.3 g |
| Baseline Drift | 25 µg |
| Baseline Repeatability | ±5 µg |
| Atmosphere Options | Inert (N₂, Ar, He) or Oxidizing (air, O₂) |
| Gas Flow Rate | 10–100 mL/min |
| Crucible Materials | Al, Al₂O₃, Pt, Quartz (130–250 µL volume) |
| Cooling | Integrated water-cooled furnace |
| Software | CALISTO 2.0 Thermal Analysis Suite |
| Power Supply | 230 V, 50/60 Hz |
| Dimensions (H×W×D) | 650(850)×400×500 mm |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Setsys EVO |
| Temperature Range | −150 °C to 1750 °C (upgradable to 2400 °C) |
| Heating Rate | 0–100 K/min (full range) |
| Max. TG Sample Capacity | 35 g / 100 g |
| TG Resolution | 0.002 µg / 0.02 µg |
| TG Baseline Repeatability | <10 µg (RT to 1750 °C) |
| DSC Resolution | 1 µW |
| DTA Resolution | 0.4 µW |
| Gas Lines | 3 carrier + 1 auxiliary/reactive gas, controlled via MFCs and solenoid valves |
| Atmosphere Options | inert, oxidative, reductive, steam, corrosive gases |
| Vacuum System | up to 10⁻⁴ mbar (10⁻² torr) |
| EGA Compatibility | MS, FT-IR, GC |
| Optional Modules | Wetsys humidity control, H₂-safe operation kit, corrosive gas kits (SO₂, NH₃, H₂S) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Setsys Evo TMA |
| Temperature Range | −150 °C to 2400 °C |
| Heating/Cooling Rate | 0–100 °C/min |
| Displacement Resolution | 0.2 nm |
| Displacement Noise | 5 nm |
| Force Range | 0–3.5 N (controllable) |
| Sample Length | 0–20 mm |
| Sample Diameter | ≤10 mm |
| Maximum Displacement Range | ±2 mm |
| Load Capacity | −150 g to +350 g |
| Measurement Modes | Compression, Penetration, 3-Point Bending, Tensile, Dilatometric, Volumetric Expansion |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Setsys Evo16 / Evo18 / Evo24 |
| Temperature Range | –150 °C to 1750 °C (upgradable to 2400 °C) |
| Heating Rate | 0–100 K/min (full range) |
| Max. TG Sample Capacity | 35 g / 100 g |
| TG Resolution | 0.002 µg / 0.02 µg |
| TG Baseline Repeatability | <10 µg (RT to 1750 °C) |
| DSC Resolution | 1 µW |
| DTA Resolution | 0.4 µW |
| Gas Channels | 3 carrier + 1 auxiliary/reactive gas, all MFC-controlled |
| Atmosphere Options | Inert, oxidative, reductive, steam, corrosive gases |
| Vacuum Level | ≤1×10⁻⁴ mbar |
| EGA Compatibility | MS, FT-IR, GC interfaces standard |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Setsys Evolution |
| Temperature Range | RT to 2400 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 0.03–0.3 µg |
| Heating/Cooling Rate | 0–100 K/min |
| Atmosphere Options | Inert, Oxidizing, Reducing, Steam, Corrosive Gases |
| Vacuum Capability | Down to 10⁻⁴ mbar |
| Modular Compatibility | DTA, DSC, TMA |
| Gas Mixing | Dual purge + protective gas with mass flow control (50/50 to 1/99 ratio) |
| Humidity Integration | Optional RH-controlled module |
| Evolved Gas Analysis (EGA) | Heated capillary transfer up to 200 °C for FTIR/MS/GC-MS coupling |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Setsys STA 2400°C |
| Temperature Range | –150 to 2400 °C |
| Heating Rate | 0.01–100 K/min |
| Max. Sample Mass | 35 g (standard), 100 g (high-capacity option) |
| TG Resolution | 0.002 µg / 0.02 µg |
| TG Baseline Repeatability | <10 µg (RT to 1750 °C) |
| DSC Resolution | 1 µW |
| DTA Resolution | 0.4 µW |
| Atmosphere Control | Inert, oxidizing, reducing, steam, corrosive gases (static/dynamic) |
| Gas Configuration | 3 carrier + 1 auxiliary/reactive gas lines with MFCs and solenoid valves |
| Vacuum Level | ≤10⁻⁴ mbar |
| EGA Compatibility | Direct coupling ports for MS, FT-IR, GC |