BrandOnline Instrument
OriginShanghai, China
ModelOL1120N
Instrument TypeLaboratory-Based
Measurement PrincipleInfrared Spectrophotometry (ASTM D7066, ISO 9377-2, HJ 637–2018)
Sample Capacity24-position carousel (expandable)
Extraction SolventTetrachloroethylene (C₂Cl₄)
Oil ClassificationPetroleum Hydrocarbons & Animal/Vegetable Oils
Separation MethodTriple-phase separation via extraction tube, aqueous barrier membrane, and phase separation column
Calibration OptionsCertified reference standards, multi-point calibration curve, single-point rapid calibration
Reagent RecoveryAutomated solvent–water immiscible phase separation
Remote AccessWeb-based GUI + mobile-responsive interface with real-time status monitoring and audit-trail-enabled command logging
Sealing MechanismAdaptive elastic dynamic pressure seal (no rotary lid wear)
Fluid HandlingHigh-precision 3-axis robotic arm + solenoid-driven micro-pumps (MTBF ≥ 4×10⁶ cycles)
MixingTurbulent vortex injection + active flow agitation
Cleaning ProtocolContinuous “live-water” rinse between samples
Detection RangeCompliant with HJ 637–2018 quantification limits (0.01–100 mg/L for petroleum hydrocarbons
Data Compliance21 CFR Part 11–ready electronic records with user-level access control, timestamped audit trail, and GLP/GMP-aligned metadata tagging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
OriginShanghai, China
ManufacturerYes
TypeLaboratory BOD Analyzer
ModelOL 4054 / OL 4108
Measurement PrincipleMicrobial Electrode Method
Measurement Range0–6000 mg/L
Detection Limit0.5 mg/L
Accuracy±0.3 mg/L (≤6 mg/L)
Incubation Duration5-day standard BOD₅ protocol
Sample Capacity54 or 108 positions (customizable)
Compliance StandardHJ 505–2009 (China Environmental Protection Standard)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
OriginShanghai, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelOL1031
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
OriginShanghai, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelOL1040
Instrument TypeLaboratory-Based
Measurement PrincipleUltraviolet Spectrophotometry
Measurement Range0–16 mg/L (with automatic dilution beyond range)
Detection Limit0.005 mg/L
Accuracy±2%
Resolution0.001 mg/L
Analysis Time<6 minutes per sample
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelOL1043
Instrument CategoryLaboratory-Based
Measurement PrincipleFluorescence Spectrophotometry
Measurement Range0–5 mg/L (with automatic dilution beyond range)
Detection Limit0.0010 mg/L
Accuracy±2%
Resolution0.001 mg/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelOL1011EX
Instrument TypeOnline Analyzer
Measurement PrincipleInfrared Spectrophotometry (C–H Stretch Absorption at 2930 cm⁻¹, 2960 cm⁻¹, 2870 cm⁻¹)
Measurement Range0–50,000 mg/L
Detection Limit0.06 mg/L
Accuracy±2% of reading
Resolution0.001 mg/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
OriginShanghai, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelOL1025
Instrument TypePortable
Measurement PrincipleInfrared Spectrophotometry
Measurement Range0–50,000 mg/L (with automatic high-concentration dilution)
Detection Limit0.06 mg/L
Accuracy±2%
Resolution0.001 mg/L
Analysis Time10 min per sample
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelOL 2030N
Instrument TypeLaboratory-Grade Volatile Phenol & Anionic Surfactant Analyzer
Sample CapacityAnionic Surfactant – up to 55 positions
Sample IntroductionRotary Disk Autosampler
Fluid HandlingPrecision Syringe + Peristaltic Pump Hybrid Delivery
Extraction ProtocolProgrammable Multi-Stage Chloroform Extraction & Back-Extraction (compliant with GB 7494-1987, HJ 503-2009, GB/T 39302-2020, etc.)
CalibrationFully Automated Standard Preparation, Multi-Point Curve Generation, and Auto-Dilution for High-Concentration Samples
Waste ManagementClosed-Loop Waste Collection, Activated Carbon Exhaust Scrubbing
ComplianceDesigned for GLP-aligned laboratory workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelOL1012
Instrument TypePortable
Measurement PrincipleInfrared Spectrophotometry (C–H Stretch Absorption at ~2960 cm⁻¹, ~2930 cm⁻¹, and ~2850 cm⁻¹)
Measurement Range0–50,000 mg/L
Detection Limit0.06 mg/L
Accuracy±2% of reading
Resolution0.001 mg/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
OriginShanghai, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelOL 3120
Instrument TypeLaboratory-Grade
Measurement Principle2-Hour Closed-Vessel Digestion Followed by Potentiometric/Colorimetric Titration
Measurement Range0–70,000 mg/L COD (with automatic dilution for over-range samples)
Accuracy≤2% RSD (vs. certified reference materials)
Repeatability≤2% RSD
Detection Limit4 mg/L COD
Sample Processing Time<3 min per sample (post-digestion titration)
Sample Capacity30–100 positions (user-configurable)
Digestion Stations20 parallel positions
Cooling MethodPoint-to-point forced-air condensation system
Endpoint DetectionDual-mode (colorimetric + algorithm-assisted hue transition recognition per ISO 6060 and EPA 410.4)
Digestion ControlIntelligent micro-boiling temperature regulation (150–165 °C, ±0.5 °C stability)
Data OutputExcel/PDF export, LIMS integration (HL7/ASTM E1384 compliant), automated report generation with audit trail
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelOL1010
Instrument TypeLaboratory Benchtop Analyzer
Measurement PrincipleInfrared Spectrophotometry (C–H Stretch Absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 2850 cm⁻¹)
Measurement Range0–50,000 mg/L
Detection Limit0.06 mg/L
Accuracy±2% of reading
Resolution0.001 mg/L
Analysis Time per Sample<60 s
Light SourceSwitching Power Supply–Driven IR Emitter
Wavelength Selection MethodMotorized Precision Grating Drive
Zero CalibrationReal-time Dual-Signal Auto-Zero (Illuminated & Dark Current Compensation)
Extraction SolventPerchloroethylene (C₂Cl₄)
Calibration ModesCertified Reference Standards, Multi-point Calibration Curve, Single-point Rapid Calibration
ComplianceMeets HJ 637–2018 (China), ASTM D7066–22 (Standard Test Method for Determination of Oil and Grease in Water by Infrared Spectrophotometry), ISO 9377-2:2000 (Water Quality — Determination of Hydrocarbon Oil Index)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelOL1046
Instrument TypePortable
Measurement PrincipleFluorescence Spectrophotometry
Measurement Range0–5 mg/L
Detection Limit0.0010 mg/L
Accuracy±2%
Resolution0.001 mg/L
Analysis Cycle Time9 minutes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory-Based
ModelOL3236
Measurement PrincipleRapid Digestion Spectrophotometry
Wavelengths600 nm ± 20 nm and 440 nm ± 20 nm
Measurement Range15–1000 mg/L COD
Accuracy±5% of reading
RepeatabilityRSD ≤ 2%
Limit of Detection4 mg/L
Cycle Time40 minutes per batch of 36 samples
Batch Capacity108 sample positions
Digestion Capacity36 simultaneous digestion units
Photometric Measurement Channels6 parallel optical cells
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelOL1020
Instrument CategoryLaboratory-Based
Measurement PrincipleInfrared Spectrophotometry (C–H Stretch Absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 2850 cm⁻¹)
Measurement Range0–50,000 mg/L
Detection Limit0.03 mg/L
Accuracy±2% of reading
Resolution0.001 mg/L
Analysis Time per Sample<5 minutes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelOL1032
Instrument TypePortable
Measurement PrincipleUltraviolet (UV) Spectrophotometry
Measurement Range0–50 mg/L
Detection Limit0.005 mg/L
Accuracy±2%
Resolution0.001 mg/L
Measurement FrequencyNot Applicable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
OriginShanghai, China
Manufacturer TypeManufacturer
Product OriginDomestic (China)
ModelOL5.0 Smart Laboratory System
Design Experience10+ Years
Price RangeUSD 140 – 14,000,000 (based on configuration and scope)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelOL1050
Detection PrincipleInfrared Absorption (FTIR-compatible broadband IR photometry)
Instrument ClassLaboratory-Based Fixed-Position Analyzer
Primary Application SectorPetrochemical Industry
Compliance BasisDesigned to support EPA Method 27 / ISO 12103-1 alignment for airborne oil aerosol quantification
Measurement RangeConfigurable via auto-dilution (standard range: 0.1–100 mg/m³, extendable to 500 mg/m³ with intelligent over-range dilution)
Sample IntroductionFilter Cartridge (glass fiber or quartz) or Sleeve-Type Sampling Probe
Extraction SolventTetrachloroethylene (C₂Cl₄)
Extraction MethodHigh-Efficiency Ultrasonic Assisted Extraction
Phase SeparationAutomatic Density-Based Liquid-Liquid Separation (C₂Cl₄/H₂O)
Calibration ModesCertified Reference Material (CRM)-based calibration, Multi-Point Standard Curve, Single-Point Rapid Calibration
Reagent HandlingFully Automated Dispensing, Recovery, and Activated Carbon–Filtered Exhaust Management
Data InterfaceEmbedded Touchscreen PC + Remote Web API & Mobile App (iOS/Android)
Software ComplianceAudit-trail enabled, 21 CFR Part 11–ready data logging (user authentication, electronic signature, change history)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
OriginShanghai, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelOL3015
Instrument TypeLaboratory-Grade
Measurement Principle2-Hour Closed-Vessel Digestion Followed by Potentiometric/Titrmetric Endpoint Detection
WavelengthNot Applicable (Titration-Based)
Accuracy≤5%
RepeatabilityRSD ≤3%
LOD4 mg/L COD
Sample Capacity15-position digestion + 15-position sample rack (expandable to 50-position autosampler)
Digestion Positions15
Titration Channels2
Chloride CorrectionIntegrated Automatic Chloride Compensation Module
Temperature ControlProgrammable Heating (15–350 °C) with Air/Water Cooling
Cleaning ProtocolFully Automated Rinse Cycles for Digestion Vessels, Titration Cells, and Fluidic Lines
Data ExportExcel/PDF Reports
LIMS IntegrationSupported (Standard ASTM D1252 & ISO 6060 Compliant Workflow)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
ModelOL1061
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypePortable
Measurement PrincipleInfrared Absorption (C–H Stretching Band at ~2930 cm⁻¹)
Measurement Range0–1000 mg/L
Detection Limit0.06 mg/L
Accuracy±2% of reading
Resolution0.001 mg/L
Extraction SolventPerchloroethylene (C₂Cl₄)
Extraction RatioAdjustable from 1:1 to 1:50 (solvent:sample)
Sampling DepthUp to 0.5 m submersible
Power SupplyIntegrated rechargeable battery (4 h continuous operation)
Data IntervalProgrammable from 1–999 s
InterfaceTouchscreen industrial PC
ComplianceDesigned to support EPA Method 1664A, ISO 9377-2, and GB/T 16488–1996 equivalency
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Region CategoryDomestic (China)
ModelOL1010D
Instrument TypeLaboratory Benchtop Analyzer
Measurement PrincipleInfrared Spectrophotometry (C–H Stretch Absorption at 2960, 2930, and 2870 cm⁻¹)
Measurement Range0–50,000 mg/L
Detection Limit0.06 mg/L
Accuracy±2% of reading
Resolution0.001 mg/L
Analysis Time per Sample<60 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
OriginShanghai, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelOL2060
Instrument TypeLaboratory Analyzer
Measurement PrincipleColorimetric Method (Nesslerization)
Measurement Range0.1–2.0 mg/L (auto-dilution available beyond range)
Accuracy<2% RSD
Detection Limit0.025 mg/L per HJ 535–2009
Analysis Time10 min (Direct Method), 50 min (Distillation Method)
Sample Capacity25-position or 50-position carousel
Measurement ModesDirect, Coagulation-Precipitation, Distillation
CalibrationMulti-point Standard Curve
Remote MonitoringWeb-based & mobile-compatible control and data retrieval
ComplianceFully aligned with HJ 535–2009, GB/T 5750.1–2023, and ISO 7150-1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
ModelOL2900N
OriginShanghai, China
Application StandardGB/T 5750.5–2023 (Diazotization-Coupling Spectrophotometry for Nitrite as N)
Automation LevelFully Automated Sample Processing, Reagent Dispensing, Calibration Curve Generation, Dilution, Measurement, and System Cleaning
ComplianceDesigned for drinking water and raw water testing per Chinese national standard methodology
Remote OperationWeb-based and mobile-compatible interface with real-time status monitoring and voice/text-assisted technical support
Sample ThroughputContinuous unattended operation with priority-sample insertion capability
Waste ManagementClosed-loop waste collection with integrated reagent-level monitoring and low-reagent alert
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
OriginShanghai, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelOL2090 Fully Automated Nitrite Analyzer
Instrument TypeLaboratory Water Quality Analyzer
AnalyteNitrite (NO₂⁻)
Linearity Coefficient≥0.999
Automation LevelFull Workflow Automation (Sample Transfer, Reagent Dispensing, Standard Preparation, Mixing, Dilution, Measurement, Cleaning, Waste Collection, Report Generation)
Compliance ContextDesigned for compliance with ISO 10304-1, ASTM D3869, and GB/T 5750.5–2023 (Standard Methods for Examination of Drinking Water – Nitrite)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnline Instrument
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelOL1045
Instrument TypePortable
Measurement PrincipleUV Spectrophotometry
Measurement Range0–60 mg/L (auto-dilution for over-range samples)
Detection Limit0.005 mg/L
Accuracy±2%
Resolution0.001 mg/L
Analysis Time<8 min per water sample