Empowering Scientific Discovery

Shanghai Jiubin Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-60L
Measurement PrinciplePhotometric Method (based on acetylacetone derivatization)
Chamber Volume1 m³
Internal DimensionsApprox. 1000 mm × 1000 mm × 1000 mm
Temperature Control Range15–30 °C (±0.5 °C uniformity)
Relative Humidity Control Range30–70 %RH (±3 %RH stability)
Air Exchange RateAdjustable from 0.5 to 1.5 h⁻¹ (±5 % accuracy)
Chamber Wall MaterialStainless Steel 304 with electropolished interior
Seal Integrity≤ 0.5 % volume loss per hour
Power Supply220 V AC, 50 Hz
ComplianceGB/T 17657–2013, GB 18580–2017, ISO 12460-1:2007, ASTM D6007–21
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
ModelJB-Series
Price RangeUSD 14,000 – 21,000 (FOB Shanghai)
Measurement PrinciplePhotometric Method (Acetylacetone Derivatization + Visible Light Absorption at 412 nm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-220E
Measurement PrinciplePhotometric Method (Based on Hantzsch Reaction)
Temperature Control Range15–30 °C (±0.5 °C stability)
Humidity Control Range40–70 % RH (±3 % RH uniformity)
Internal Volume220 L
Chamber ConstructionStainless Steel 304 inner chamber with double-wall insulation and PID-controlled heating/cooling + humidification/dehumidification system
ComplianceDesigned to meet ISO 16000-9, GB/T 18204.2–2014, JIS A 1912, and ASTM D6007 requirements for formaldehyde emission testing preconditioning
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-220E
Measurement PrinciplePhotometric Method (based on acetylacetone derivatization)
Chamber Volume1 m³
Temperature Control Range15–30 °C (±0.5 °C uniformity)
Relative Humidity Control Range30–70 % RH (±3 % RH stability)
Air Exchange Rate0.5–1.5 h⁻¹ (adjustable, calibrated per ISO 12460-1)
Internal Surface MaterialStainless Steel 316L with electropolished finish
Sample CapacityUp to 1.0 m² test specimen (standardized board or furniture panel)
ComplianceISO 12460-1, GB/T 17657–2013, ASTM D6007–22, JIS A 1460
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelJB-220E
Price RangeUSD 14,000 – 42,500 (FOB Shanghai)
Detection PrincipleDynamic Chamber Method with Integrated PID/EC Sensor Array
Instrument TypeContinuous Online Monitoring System
Standard ConfigurationIntegrated TVOC + Formaldehyde Dual-Channel Analysis Module
Humidity Control Range30–70% RH
Humidity Control Accuracy±3.0% RH
Humidity Resolution±2% RH
Airflow Velocity in Chamber0.1–0.3 m/s
Chamber Volume1 m³ (standard), configurable to 0.5–5 m³
Temperature Control Range15–35°C (±0.5°C stability)
MaterialElectropolished 316L Stainless Steel Interior with Silicone-Free Sealing
ComplianceMeets ASTM D6007–22, ISO 16000-9:2022, GB/T 18883–2022, and JIS A 1912:2020 requirements for chamber-based emission testing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-60L
Measurement PrinciplePhotometric Method (Formaldehyde-Specific Chromogenic Reaction)
Chamber Volume60 L
Applicable StandardsGB 18585–2023, GB/T 27630–2011, ISO 16000-9, VDA 278, DIN 53165, ASTM D5116
Temperature Control Range15–30 °C (±0.5 °C uniformity)
Relative Humidity Control Range30–70 % RH (±3 % RH stability)
Air Exchange RateAdjustable 0.5–2.0 h⁻¹ (certified flow meter calibrated per ISO 5167)
Internal ConstructionElectropolished 316L stainless steel
Sampling PortDual 6-mm Swagelok®-compatible ports with inert PFA tubing interface
Power Supply220 VAC ±10 %, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-60L
Measurement PrinciplePhotometric Method (Based on Acetylacetone Reaction)
Chamber Volume60 L
Internal Dimensions400 × 400 × 375 mm (W × D × H)
Temperature Control Range15–40 °C (±0.5 °C stability)
Relative Humidity Control Range30–80 % RH (±3 % RH uniformity)
Air Exchange Rate0.5–2.0 h⁻¹ (adjustable, calibrated per ISO 12460-1 & ASTM D6007)
ConstructionStainless Steel 304 inner chamber, double-wall insulated design with tempered glass observation window
Touch Interface7-inch capacitive touchscreen with embedded control firmware
Data LoggingInternal SD card storage + USB export
ComplianceDesigned to meet ISO 12460-1, ISO 16000-9, ASTM D6007, JIS A 1460, GB/T 17657–2013 Annex D
Show next