- All
- Favorite
- Popular
- Most rated
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB5100-H |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.1 µm – 600 µm |
| Repeatability | ≤0.5% (D50 of NIST-traceable standard reference material) |
| Measurement Time | <10 s per run (excluding dispersion conditioning) |
| Compliance | ISO 13320:2020, GB/T 19077–2016 |
| Laser Source | Fiber-coupled semiconductor laser, λ = 635 nm, output power >10 mW |
| Detector Channels | 70-channel high-density photodiode array |
| Optical Alignment | Motorized auto-centering system (0.2 µm step resolution, full alignment in ≤15 s) |
| Ultrasonic Dispersion | Frequency 40 kHz, power adjustable 0–80 W, dry-run protection integrated |
| Circulation System | Flow rate 0–10 L/min, variable speed pump (100–33950 rpm), sample volume ≥120 mL (optional micro-mode: ≥10 mL) |
| Sample Cell | Boiling-type dispersion cell (190–600 mL capacity), quick-release quartz window, dew-point monitoring sensor, bubble-free optical path design |
| Enclosure | Sealed dust- and shock-resistant chassis |
| Optional Configurations | Chemical-resistant wetted parts (acid/alkali/solvent compatible), GLP-compliant audit trail module |
| Brand | Jiubin Instruments |
|---|---|
| Model | JB-N9 |
| Origin | Shanghai, China |
| Laser Wavelength | 532 nm (LD-pumped, temperature-stabilized) |
| Detection Angle | 90° |
| Detector | Hamamatsu Photomultiplier Tube (PMT) with Single-Mode Polarization-Maintaining Fiber |
| Sample Cell | 10 mm × 10 mm quartz cuvette, 4 mL capacity (temperature-controlled) |
| Measurement Range | 1–10,000 nm (sample-dependent) |
| Concentration Range | 0.1–100 mg/L |
| Accuracy | <1% (vs. NIST-traceable standard reference materials) |
| Repeatability | <1% (RSD of mean diameter) |
| Temperature Control Range | 8–45 °C (±0.1 °C stability) |
| Correlator | Custom ASIC-based high-speed photon correlator |
| Data Analysis | Cumulant method + regularized non-negative least-squares (NNLS) inversion |
| Output | Z-average diameter (d<sub>Z</sub>), polydispersity index (PDI), intensity-weighted size distribution, volume/mass distribution (derived), full exportable distribution tables and plots |
| Measurement Time | <60 s per run (excluding dispersion preparation) |
| Compliance | GB/T 29022–2012, ISO 22412:2008 |
| Dimensions | 390 × 255 × 240 mm |
| Power | AC 100–260 V, 50/60 Hz, max. 80 W |
| Operating Environment | 15–40 °C, 20–70% RH, non-condensing |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB5500-L |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.1 µm – 1000 µm |
| Repeatability | < 0.5% |
| Measurement Time | < 10 s per analysis |
| Compliance | GB, ASTM, ISO, JIS, DIN, CNS |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB6100-B |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range (Wet) | 0.01 µm – 2000 µm |
| Repeatability | ≤ ±0.5% |
| Measurement Time | 10 s |
| Brand | Jiubin Instruments |
|---|---|
| Model | JB6100-A |
| Origin | Shanghai, China |
| Disperser Type | Wet Dispersion System |
| Measurement Range | 0.01 µm – 2000 µm |
| Repeatability | <0.5% RSD (D50 of NIST-traceable standard reference materials) |
| Measurement Time | ≤10 s per analysis (optical acquisition only) |
| Detector Channels | 121 |
| Laser Source | Dual-beam, fiber-coupled, λ = 650 nm, P > 10 mW |
| Optical Path Calibration | Fully automated real-time alignment |
| Compliance | ISO 13320:2020, GB/T 19077–2016, ASTM D4294–22 (applicable for colloidal & suspension systems) |
| Sample Handling | Self-cleaning fluidic path with zero residual carryover |
| Environmental Design | Dust- and shock-resistant chassis |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | JB-400H |
| Pricing | Available Upon Request |
| Brand | Jiubin Instruments |
|---|---|
| Model | JB-N9 |
| Principle | Dynamic Light Scattering (DLS) / Photon Correlation Spectroscopy (PCS) |
| Measurement Range | 1–10,000 nm |
| Concentration Range | 0.1–100 mg/L |
| Accuracy | <1% (NIST-traceable standard samples) |
| Repeatability | <1% (NIST-traceable standard samples) |
| Laser Source | 532 nm LD-pumped solid-state laser with integrated temperature stabilization |
| Detector | Hamamatsu single-photon-counting photomultiplier tube (PMT) coupled via single-mode polarization-maintaining fiber |
| Scattering Angle | 90° |
| Correlator | Custom ASIC-based high-speed digital photon correlator |
| Sample Cell | 10 mm × 10 mm square quartz cuvette, 4 mL volume, Peltier-controlled (±0.1 °C) |
| Data Analysis | Cumulant method + regularized non-negative least-squares (NNLS) inversion |
| Output | Z-average diameter (d<sub>Z</sub>), polydispersity index (PDI), intensity-weighted size distribution histogram & tabular data |
| Temperature Control Range | 8–45 °C |
| Measurement Time | <60 s per run (excluding dispersion) |
| Dimensions | 390 × 255 × 240 mm |
| Power Supply | AC 100–260 V, 50/60 Hz, max. 80 W |
| Operating Environment | 15–40 °C, 20–70% RH, non-condensing |
| Compliance | GB/T 29022–2012, ISO 22412:2008 |
| Brand | Jiubin |
|---|---|
| Model | JB-400H |
| Origin | Shanghai, China |
| Die Diameter | Φ2.095 ± 0.005 mm |
| Die Length | 8.000 ± 0.025 mm |
| Barrel Diameter | Φ9.550 ± 0.007 mm |
| Barrel Length | 152 ± 0.1 mm |
| Piston Head Diameter | 9.474 ± 0.007 mm |
| Piston Head Length | 6.350 ± 0.100 mm |
| Standard Test Loads (8 levels) | 0.325 kg to 21.600 kg (3.187 N to 211.82 N |
| Temperature Range | Ambient to 450 °C |
| Temperature Stability | ±0.2 °C |
| Control System | PLC-based |
| Human-Machine Interface | 5-inch color touch screen |
| Display | LCD |
| Report Output | Thermal printer support |
| Melt Cutting Modes | Manual / Time-controlled / Automatic |
| Test Method | Gravimetric (MFR) |
| Dimensions (L×W×H) | 250 × 350 × 510 mm |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-6100-B |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01 µm – 2000 µm |
| Repeatability | <1% (D50 of standard reference material) |
| Measurement Time | <10 s typical |
| Compliance | ISO 13320:2009, GB/T 19077–2016 |
| Detector Channels | 87-channel high-density crossed array with area compensation |
| Optical Model | Full-range Mie scattering theory with dynamic multiple-scattering correction |
| Laser Source | Sealed fiber-coupled semiconductor laser, λ = 650 nm, P > 10 mW |
| Data Acquisition | 16-bit, 200 kHz sampling rate |
| Feed System | Motorized stepless-speed feeder with software-controlled oil-free silent air compressor (integrated moisture and particulate filtration) |
| Operating Environment | 0–45 °C, 10–85% RH (non-condensing) |
| Power Supply | 110–240 V AC ±20 V, 50–60 Hz |
| Dimensions | 700 × 495 × 300 mm |
| Weight | 35 kg |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB6100-D |
| Dispersion Method | Dry & Wet |
| Measurement Range | 0.01 µm – 1250 µm |
| Repeatability | <1% |
| Measurement Time | 60 s per test |