- All
- Favorite
- Popular
- Most rated
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | JB-16 |
| Price Range | USD 7,000–14,000 |
| Measurement Principle | Laser Flash Method (ASTM E1461, ISO 22007-4 compliant) |
| Dimensions (L×W×H) | 3000 × 2200 × 1500 mm |
| Accuracy Class | 0.5 (per GB/T 7782–2008 & JJG 1044–2008) |
| Thermal Conductivity Test Range | 0.03–4.0 W/(m·K) |
| Repeatability | ≤ ±2.0% (at 23 °C, RH 50%, standard reference material NIST SRM 1453) |
| Brand | Jiubin Instruments |
|---|---|
| Model | JB-P |
| Measurement Principle | Guarded Hot Plate Method (ASTM C177, ISO 8302) |
| Thermal Conductivity Range | 0.010–5.000 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ±3% |
| Dimensions (L×W×H) | 552 × 550 × 760 mm |
| Origin | Shanghai, China |
| Instrument Type | Guarded Hot Plate Thermal Conductivity Analyzer |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-PL |
| Measurement Principle | Guarded Hot Plate (Steady-State Heat Flow Method) |
| Test Standard Compliance | ASTM C177, ISO 8302, GB/T 10294 |
| Thermal Conductivity Range | 0.010–5.000 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ±3% |
| Dimensions (L×W×H) | 552 × 550 × 760 mm |
| Power Supply | 220 V AC, 50 Hz |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-P |
| Measurement Principle | Guarded Hot Plate Method (ASTM C177, ISO 8302) |
| Temperature Range | -40 °C to +150 °C (with optional cryo/heating modules) |
| Thermal Conductivity Range | 0.010–5.000 W/(m·K) |
| Accuracy | ±3% of reading |
| Repeatability | ±3% |
| Dimensions (L×W×H) | 552 × 550 × 760 mm |
| Compliance | ASTM C177, ISO 8302, GB/T 10294 |
| Brand | Jiubin Instruments |
|---|---|
| Model | JB-PL |
| Measurement Principle | Steady-State Guarded Hot Plate (ASTM C177, ISO 8302) |
| Thermal Conductivity Range | 0.010–5.000 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ±3% |
| Overall Dimensions (L×W×H) | 552 × 550 × 760 mm |
| Origin | Shanghai, China |
| Instrument Type | Guarded Hot Plate Analyzer |
| Compliance | ASTM C177, ISO 8302, GB/T 10294 |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | JB-S |
| Instrument Principle | Transient Plane Source (TPS) Method |
| Dimensions (L×W×H) | 500 × 800 × 1200 mm |
| Accuracy | ±3% |
| Thermal Conductivity Range | 0.005–300 W/(m·K) |
| Repeatability | ±3% |
| Brand | JuBen |
|---|---|
| Origin | Shanghai, China |
| Model | JB-S |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Dimensions (L×W×H) | 500 × 800 × 1200 mm |
| Accuracy | ±3% |
| Thermal Conductivity Range | 0.005–300 W/(m·K) |
| Repeatability | ±3% |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-S |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Dimensions (L×W×H) | 500 × 800 × 1200 mm |
| Accuracy | ±3% |
| Thermal Conductivity Range | 0.005–300 W/(m·K) |
| Repeatability | ±3% |
| Instrument Type | Benchtop Thermal Conductivity Analyzer |
Show next