Empowering Scientific Discovery

Shanghai Jiubin Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (PRC)
ModelJB-16
Price RangeUSD 7,000–14,000
Measurement PrincipleLaser Flash Method (ASTM E1461, ISO 22007-4 compliant)
Dimensions (L×W×H)3000 × 2200 × 1500 mm
Accuracy Class0.5 (per GB/T 7782–2008 & JJG 1044–2008)
Thermal Conductivity Test Range0.03–4.0 W/(m·K)
Repeatability≤ ±2.0% (at 23 °C, RH 50%, standard reference material NIST SRM 1453)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
ModelJB-P
Measurement PrincipleGuarded Hot Plate Method (ASTM C177, ISO 8302)
Thermal Conductivity Range0.010–5.000 W/(m·K)
Accuracy±3%
Repeatability±3%
Dimensions (L×W×H)552 × 550 × 760 mm
OriginShanghai, China
Instrument TypeGuarded Hot Plate Thermal Conductivity Analyzer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-PL
Measurement PrincipleGuarded Hot Plate (Steady-State Heat Flow Method)
Test Standard ComplianceASTM C177, ISO 8302, GB/T 10294
Thermal Conductivity Range0.010–5.000 W/(m·K)
Accuracy±3%
Repeatability±3%
Dimensions (L×W×H)552 × 550 × 760 mm
Power Supply220 V AC, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-P
Measurement PrincipleGuarded Hot Plate Method (ASTM C177, ISO 8302)
Temperature Range-40 °C to +150 °C (with optional cryo/heating modules)
Thermal Conductivity Range0.010–5.000 W/(m·K)
Accuracy±3% of reading
Repeatability±3%
Dimensions (L×W×H)552 × 550 × 760 mm
ComplianceASTM C177, ISO 8302, GB/T 10294
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
ModelJB-PL
Measurement PrincipleSteady-State Guarded Hot Plate (ASTM C177, ISO 8302)
Thermal Conductivity Range0.010–5.000 W/(m·K)
Accuracy±3%
Repeatability±3%
Overall Dimensions (L×W×H)552 × 550 × 760 mm
OriginShanghai, China
Instrument TypeGuarded Hot Plate Analyzer
ComplianceASTM C177, ISO 8302, GB/T 10294
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Region of ManufactureDomestic (China)
ModelJB-S
Instrument PrincipleTransient Plane Source (TPS) Method
Dimensions (L×W×H)500 × 800 × 1200 mm
Accuracy±3%
Thermal Conductivity Range0.005–300 W/(m·K)
Repeatability±3%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJuBen
OriginShanghai, China
ModelJB-S
Measurement PrincipleTransient Plane Source (TPS) Method
Dimensions (L×W×H)500 × 800 × 1200 mm
Accuracy±3%
Thermal Conductivity Range0.005–300 W/(m·K)
Repeatability±3%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-S
Measurement PrincipleTransient Plane Source (TPS) Method
Dimensions (L×W×H)500 × 800 × 1200 mm
Accuracy±3%
Thermal Conductivity Range0.005–300 W/(m·K)
Repeatability±3%
Instrument TypeBenchtop Thermal Conductivity Analyzer