Empowering Scientific Discovery

Shanghai Jiubin Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelJB-150-BK-S
QuotationUpon Request
Test MediumMunicipal Tap Water
Max Test Pressure0–1500 bar (150 MPa)
Drive Air Pressure6.9 bar
Pressure Ramp Rate100–6000 bar/min (adjustable)
Pressure Measurement AccuracyClass 0.5 (high-precision transducer)
Power Supply220 V, 50 Hz, 0.15 kW
Drive MethodPneumatically Actuated Dual-Pump System
Air Supply Requirement3–6.9 bar, 2 m³/min
High-Pressure Outlet1 × G1/4″ internal thread (600 series)
Control Cabinet Dimensions800 × 700 × 1500 mm
Test Chamber Dimensions2000 × 900 × 1200 mm (304 stainless steel, with integrated water recovery sump and stainless mesh tray)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin
ModelJB
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelJB-B
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-400H
ComplianceGB/T 3682.1–2018, ISO 1133–1:2011, ASTM D1238
Temperature Control RangeAmbient to 400 °C (±0.2 °C stability)
Load Options0.325–21.6 kg (standard weights per ISO/ASTM)
Extrudate CuttingAutomatic timer-based or manual
Piston Travel Resolution0.01 mm
Data OutputMFR (g/10 min), MVR (cm³/10 min), flow rate curve
Power SupplyAC 220 V ±10%, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin
OriginShanghai, China
ModelJB-150-BK
Test MediumMunicipal tap water or customer-specified fluid
Max Test Pressure0–1500 bar (150 MPa)
Drive Air Pressure6.9 bar
Pressure Ramp Rate100–6000 bar/min (adjustable)
Pressure Measurement Accuracy±0.5% FS (high-precision strain-gauge transducer)
Power Supply220 V, 50 Hz, 0.15 kW
Drive MethodPneumatically actuated dual-pump system (low- and high-pressure stages)
Air Supply Requirement3–6.9 bar, ≥2 m³/min
High-Pressure Outlet1 × G1/4" internal thread (600 psi rated)
Control Cabinet Dimensions800 × 700 × 1500 mm
Test Chamber Dimensions2000 × 900 × 1200 mm (2 mm steel + energy-absorbing buffer layer)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-JM8
Test MediumHydraulic Oil or Ethylene Glycol Mixture
Max Test Pressure0–5 MPa (adjustable)
Pressure Control Accuracy±0.01 MPa (full scale dependent)
Pulse Frequency5–120 cycles/min (adjustable)
Pulse WaveformSquare or Trapezoidal (pulse width configurable per user requirement)
Test Medium Temperature RangeAmbient to 160 °C
Environmental Temperature Range–30 °C to 250 °C (adjustable)
Maximum Continuous Cycles≥1,000,000
Control MethodPC-based Automated Control with Servo/Proportional Actuation
Data InterfaceUSB for data export and report printing
ComplianceDesigned for ISO 6803, ISO 7241-2, SAE J1401, ASTM D3078, and GB/T 5563 testing protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin
OriginShanghai, China
ModelJB-600-5
Sinusoidal Force Range9800–49000 N
Rated Frequency Range5–3000 Hz
Peak Velocity1020 m/s
Zero-Load Acceleration1.5 m/s²
Peak-to-Peak Displacement51 mm
Payload Capacity140–1000 kg
Power Consumption22–76 kVA
Supply VoltageAC 380 V ±10%, 50 Hz
Moving Coil Mass3–50 kg
Power Amplifier Weight250–800 kg
Cooling MethodForced Air
ComplianceGB/T 13310-91, Q/320502SN001-2003
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
ModelJB-JM8
TypeHydraulic Pressure Test System
Max Test Pressure0–400 MPa
Pressure Control Accuracy±1% F.S.
Measurement Accuracy±0.075% F.S.
Timing Range0–999 h
Test MediaWater, Hydraulic Oil, or Custom Fluids
Media Temperature RangeAmbient to 150 °C ±3 °C
Drive Air Supply3–8 bar
Power SupplyAC 220 V
Control OptionsManual / PLC / Computer-Controlled (SCADA-Compatible)
Test StationsSingle or Multi-Station (Customizable)
Sealing ArchitectureNon-Welded, Modular Tubing Connections
Safety ResponseAutomatic Pressure Dump & Pump Shutdown upon Burst Detection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelJB-JM8
PricingAvailable Upon Request
Test MediumOil, Water, or Ethylene Glycol Mixture
Medium Temperature RangeAmbient to 130 °C
Maximum Pulse Pressure0–70 MPa
Pressure Control Accuracy±0.01 MPa
Pulse WaveformSquare or Stepped Profile
Pulse Frequency5–60 cycles/min
Maximum Continuous Test Cycles>100,000 (single run)
Continuous Operation Duration≥240 hours (10 days)
ComplianceDesigned for ISO 6803, SAE J1401, GB/T 5563, ISO 6802, and FMVSS 106 test protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic
ModelJB
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-JM8
Test Pressure Range0–100 MPa (customizable)
Pulse Frequency0–2 Hz (customizable)
Test MediaWater, Brake Fluid, Hydraulic Oil
Media Temperature Range−40 °C to +150 °C (customizable)
Cycle Count Capacity>10⁷ cycles (user-definable)
Channel Configuration1 channel (expandable)
Waveform OptionsSquare, T-shaped, Triangular, Sine
Control ArchitectureDual-level PC-based electro-hydraulic servo control with independent modular controllers
Pressure Regulation MethodAccumulator-assisted passive pressure maintenance
Safety FeaturesOverpressure cutoff, overload protection, automatic depressurization upon rupture, auto-degassing at startup, post-test fluid containment
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelJB-JM8
PricingAvailable Upon Request
Test Pressure Range0–100 MPa
Pressure Control Accuracy±0.1 MPa
Test MediaCompressed Air, Nitrogen, Oxygen, or Other Inert Gases
Number of Test Ports1 (Configurable)
Control SystemServo-Driven Pressure Regulation with PC Interface
Data OutputReal-Time Pressure Curve Display, USB Storage, Printable Test Reports
Structural DesignFully Enclosed Frame with Castor-Mounted Mobility
ComplianceDesigned for ISO 5208, ASTM E493, and EN 1759-2 Prequalification Requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJB-Bin
OriginShanghai, China
ModelJM8
Test MediumOil, Water, or Ethylene Glycol Mixture
Max Pulse Pressure0–70 MPa (adjustable, optional higher range)
Pressure Control Accuracy±0.01 bar
Pulse Frequency0–2 Hz (dependent on specimen volume and compliance)
Waveform OptionsSquare, T-wave, Triangular, Sine
Test Temperature Range–40 °C to +150 °C (±3 °C)
Cycle Capacity≥100,000 cycles per continuous test run
Continuous Operation Duration≥720 hours (30 days)
Specimen Capacity2–8 units (configurable per system setup)
Mounting Angles90° or 180° per ISO 6803 / SAE J1401 / GB/T 14904 compliance
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin
OriginShanghai, China
ModelJB-C5
Wind Pressure Range–8000 to +8000 Pa (for wind load resistance)
Air Flow Rate0–540 m³/h
Water Spray Rate2–3 L/m²·min
Displacement Measurement Range0–50 mm
Specimen Size Capacity0.8 × 0.8 m to 3.0 × 3.0 m
Power SupplyAC 380 V, 50 Hz, 20 kW
Required Installation Space6 m × 5 m × 3.6 m
Accuracy Class0.25 (pressure), 3 (air flow), 2.5 (spray), 0.2 (displacement)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelJB-WD2D
Table Diameter800 mm
Tilting Range0–30° ±1°
Max Load Capacity120 kg
Actuation ModeManual
Rotation Speed1 rpm
ComplianceGB 4706-1:20.1, IEC 60335-1:20.1
Optional UL-Compliant Range0–42° (custom order)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin
ModelJB-UV
OriginShanghai, China
TypeUV Germicidal Conveyor Tunnel
UV Lamp Configuration16 × 20 W low-pressure mercury lamps (254 nm peak)
Effective UV Irradiation Zone1000 mm
Conveyor Length2000 mm
Inlet/Outlet Height200 mm (adjustable)
Inlet/Outlet Width500 mm
Conveyor Height from Floor750 ± 50 mm
Lamp Tube Length600 mm
Safety ProtectionsOvervoltage/overcurrent protection, fault alarm indicator, motor overload protection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
ModelJB-150-BK-S
Max Test Pressure0–1500 bar (150 MPa)
Test MediumMunicipal Tap Water
Drive Air Pressure3–6.9 bar
Air Flow Rate2 m³/min
Pressure Control Accuracy±10 bar (hold), ±0.5% FS (sensor)
Pressure Ramp Rate100–6000 bar/min (adjustable)
Power Supply220 V, 50 Hz, 0.15 kW
Control InterfaceIntegrated Touchscreen PC with A4 Report Export
Dimensions (Control Cabinet)800 × 700 × 1500 mm
Dimensions (Test Chamber)2000 × 900 × 1200 mm
Construction304 Stainless Steel Chamber + Dual-Pump Air-Driven Hydraulic System
Safety FeaturesExplosion-Resistant Tempered Glass Lid, Automatic Depressurization, Dual-Stage Filtration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin
OriginShanghai, China
ModelJB-JM8
Test MediumHydraulic Oil or Ethylene Glycol Mixture
Max Test Pressure0–5 MPa (adjustable)
Pressure Control Accuracy±0.01 MPa (full scale dependent)
Pulse Frequency5–120 cycles/min (adjustable)
Pulse WaveformSquare or Trapezoidal (pulse width configurable per user specification)
Test Medium Temperature RangeAmbient to 160 °C
Environmental Temperature Control Range−30 °C to 250 °C
Maximum Continuous Cycles>1,000,000
Control MethodPC-based Automated Control with Servo/Proportional Actuation
ComplianceDesigned for ISO 6803, SAE J1402, GB/T 5563, and ASTM D380-conforming validation protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
ModelJB-JM8
TypeDual-Pulse Hydraulic Fatigue Testing System
OriginShanghai, China
ApplicationPressure cycling fatigue testing of pressurized components
ControlComputer-controlled servo/proportional hydraulic system
Max. Test Cycles≥1,000,000 cycles (continuous)
Test MediumHydraulic oil or ethylene glycol–water mixture
Pressure Range0–5 MPa (adjustable)
Pressure Control Accuracy±0.01 MPa (full-scale dependent)
Pulse Frequency5–120 cycles/min (programmable)
Pulse WaveformSquare or trapezoidal (pulse width configurable per user specification)
Fluid Temperature RangeAmbient to 160 °C (user-defined setpoint)
Environmental Chamber Temp. Range–30 °C to +250 °C (optional integrated thermal enclosure)
Data AcquisitionReal-time pressure vs. time curve logging, USB export, automated report generation
Compliance SupportDesigned to support ASTM D3078, ISO 6803, SAE J1402, GB/T 10544, and internal OEM validation protocols
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: JB Instruments
ModelJB-150-BK-S
OriginShanghai, China
Drive MediumCompressed Air (3–6.9 bar)
Test MediumMunicipal Tap Water
Max Test Pressure0–1500 bar (150 MPa)
Pressure Control Accuracy±10 bar (hold), ±0.5% FS (sensor)
Pressure Ramp Rate100–6000 bar/min (adjustable)
Power Supply220 V, 50 Hz, 0.15 kW
High-Pressure Outlet1 × G1/4 internal thread (600 series)
Cabinet Dimensions800 × 700 × 1500 mm
Test Chamber Dimensions2000 × 900 × 1200 mm (304 stainless steel, dual-zone with integrated water recovery tank)
Safety FeaturesBlast-resistant tempered glass lid, automatic pressure relief, real-time curve logging, audit-ready data export
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin
OriginShanghai, China
ModelJB-400H
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-400H
ComplianceGB/T 3682.1–2018, ASTM D1238, ISO 1133–1
Temperature Control Range100–400 °C (±0.2 °C)
Load Options0.325 kg, 1.2 kg, 2.16 kg, 5.0 kg, 10.0 kg, 21.6 kg
Piston Travel DetectionHigh-resolution optical encoder (0.01 mm resolution)
Extrudate CuttingAutomatic timed or manual mode
Sample Preheating TimeProgrammable (0–999 s)
Data OutputUSB and RS232 interfaces
Display7-inch TFT touchscreen with real-time melt flow curve visualization
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelJB-B
Price RangeUSD 11,200 – 21,000
Sensor Dimensions460 mm × 620 mm
Active Sensing Area400 mm × 400 mm
Sensor Resolution2,288 discrete pressure points
Thickness0.2 mm
Maximum Load Capacity100 kg (≈981 N)
Accuracy±10% FS (as-received), ±5% FS (post-calibration)
Operating Temperature−9 °C to +60 °C
InterfaceUSB 2.0
Power SupplyBus-powered via USB
Sampling Rate0–100 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelJB-201E
PriceUpon Request
Measurement PrincipleUV-Vis Spectrophotometry (Acetylacetone Colorimetric Method)
Wavelength Range325–1000 nm
Spectral Bandwidth5 nm
Wavelength Accuracy±2 nm
Wavelength Repeatability1 nm
Photometric RangeTransmittance 0–100%, Absorbance 0–2.0 A
Formaldehyde Quantification Range5.00–500.00 mg/kg
Photometric Accuracy±2% FS
Light SourceImported Long-Life Tungsten-Halogen Lamp
Optical SystemSelf-Aligning Optical Path with 1200 lines/mm Diffraction Grating Monochromator
Power SupplyAC 220 V ±10%, 50 Hz, 50 W
Dimensions (W×D×H)400 × 300 × 200 mm
Weight10 kg
Show next