Empowering Scientific Discovery

Shanghai Jiubin Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (PRC)
ModelJB-16
Price RangeUSD 7,000–14,000
Measurement PrincipleLaser Flash Method (ASTM E1461, ISO 22007-4 compliant)
Dimensions (L×W×H)3000 × 2200 × 1500 mm
Accuracy Class0.5 (per GB/T 7782–2008 & JJG 1044–2008)
Thermal Conductivity Test Range0.03–4.0 W/(m·K)
Repeatability≤ ±2.0% (at 23 °C, RH 50%, standard reference material NIST SRM 1453)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-DSC-800L
Instrument TypeDSC
Temperature RangeAmbient to 800 °C
Temperature Accuracy±0.1 °C
Heating/Cooling Rate0.1–100 °C/min
DSC Heat Flow Range±200 mW
Sample CapacitySingle-sample configuration
Detection Sensitivity0.1 μW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin
OriginShanghai, China
ModelJB-STA-200
Heating Rate1–80 °C/min
Temperature RangeAmbient to 1150 °C (extendable to 1350 °C)
Temperature Stability±0.1 °C
Atmosphere OptionsInert, Oxidizing, Reducing
Sample CapacityDetermined by Crucible Size
Vendor TypeAuthorized Distributor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-DSC-500L
Temperature Range-150 to 500 °C
Temperature Accuracy±0.1 °C
Temperature Resolution0.01 °C
Heating/Cooling Rate0.1–50 K/min (heating), 0.1–10 K/min (cooling)
DSC Sensitivity0.1 µW
DSC Accuracy±1%
DSC Dynamic Range±200 mW
Atmosphere ControlDual-gas mass flow controller with automatic switching
CalibrationIntegrated standard reference materials with one-click temperature calibration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-DSC-800
Sample CapacitySingle
Instrument TypeHeat-Flow DSC
Temperature RangeAmbient to 600 °C
Temperature Accuracy±0.1 °C
Heating/Cooling Rate0.1–80 °C/min
DSC Signal Range0 to ±600 mW
Temperature Resolution0.01 °C
DSC Noise Level0.001 mW
DSC Sensitivity & Resolution0.01 mW
Atmosphere ControlAutomated Gas Switching (N₂, O₂, Air)
Gas Flow Rate0–200 mL/min
Gas Pressure0.2 MPa
Display7-inch 24-bit color LCD touchscreen
Data InterfaceStandard USB
CalibrationIntegrated reference materials with one-click temperature & enthalpy calibration
Power SupplyAC 220 V, 50 Hz
Power Consumption600 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin
OriginShanghai, China
ModelJB-DSC-500B
Instrument TypeHeat-Flow DSC
Temperature RangeAmbient to 500 °C
Temperature Accuracy±0.1 °C
Heating/Cooling Rate0.1–80 K/min
Sample CapacitySingle-sample configuration
ComplianceDesigned for ASTM E794, ISO 11357, and USP <1163> thermal analysis workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin
ModelJB-3500F
OriginShanghai, China
Instrument TypeThermal Gravimetric Analyzer (TGA-based) for Polymer Additive Quantification
ComplianceASTM D1606, ISO 6964, GB/T 13021, USP <467> (residual solvent context), GLP-ready architecture
Sample FormGranules, pellets, powder, film fragments
Temperature RangeAmbient to 950 °C
Heating Rate0.1–100 °C/min
Balance Resolution0.01 mg
Atmosphere ControlDual-gas (N₂/air) switching module
Data OutputCSV, PDF, XML
SoftwareJiubin TGA Pro v3.2 (21 CFR Part 11 compliant audit trail, user role management, electronic signature support)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-DSC-500
Temperature RangeAmbient to 500 °C
Temperature Accuracy±0.1 °C
Heating/Cooling Rate0.1–50 K/min
DSC Heat Flow Range±500 mW
DSC Noise Level0.01 μW
Thermal Resolution0.01 μW
Temperature Resolution0.1 °C
Repeatability (Temperature)±0.1 °C
Baseline Stability<0.05 μW over 30 min
Gas Flow ControlDigital Mass Flow Controller
Interface7-inch 24-bit LCD Touchscreen + USB Data Export
Calibration StandardCertified Tin Reference Material (Sn, mp = 231.928 °C)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJUZEN
ModelJB-STA-200
OriginShanghai, China
TypeBenchtop Simultaneous Thermogravimetric Analyzer with Differential Scanning Calorimetry
Temperature RangeAmbient to 1100 °C
Heating Rate0.1–100 °C/min
Mass Resolution0.1 µg
DSC Sensitivity<0.1 µW
Atmosphere ControlDual-gas (N₂/air) with mass flow controller
Sample CapacityUp to 200 mg
ComplianceASTM E1131, ISO 11358, ISO 17516, USP <41>, GLP-ready data logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-DSC-500B
Sample Capacity1
Instrument TypeDifferential Scanning Calorimeter
Temperature RangeAmbient to 500 °C
Temperature Accuracy±0.01 °C
Heating/Cooling Rate0.1–100 K/min
DSC Heat Flow Range±600 mW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin
OriginShanghai, China
ModelJB-DSC-500B
Sample Capacity1
Instrument TypeDSC
Temperature RangeAmbient to 500 °C
Temperature Accuracy±0.1 °C
Heating/Cooling Rate0.1–100 K/min
DSC Heat Flow Range±600 mW
ComplianceGB/T 19466.2–2004, GB/T 19466.3–2004, GB/T 19466.6–2009, ISO 11357-2:1999, ISO 11357-3:1999
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
ModelJB-P
Measurement PrincipleGuarded Hot Plate Method (ASTM C177, ISO 8302)
Thermal Conductivity Range0.010–5.000 W/(m·K)
Accuracy±3%
Repeatability±3%
Dimensions (L×W×H)552 × 550 × 760 mm
OriginShanghai, China
Instrument TypeGuarded Hot Plate Thermal Conductivity Analyzer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-PL
Measurement PrincipleGuarded Hot Plate (Steady-State Heat Flow Method)
Test Standard ComplianceASTM C177, ISO 8302, GB/T 10294
Thermal Conductivity Range0.010–5.000 W/(m·K)
Accuracy±3%
Repeatability±3%
Dimensions (L×W×H)552 × 550 × 760 mm
Power Supply220 V AC, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-P
Measurement PrincipleGuarded Hot Plate Method (ASTM C177, ISO 8302)
Temperature Range-40 °C to +150 °C (with optional cryo/heating modules)
Thermal Conductivity Range0.010–5.000 W/(m·K)
Accuracy±3% of reading
Repeatability±3%
Dimensions (L×W×H)552 × 550 × 760 mm
ComplianceASTM C177, ISO 8302, GB/T 10294
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-DSC-800
Sample CapacitySingle
Instrument TypeDSC
Temperature RangeAmbient to 1050 °C
Temperature Accuracy±0.1 °C
Heating/Cooling Rate0.1–100 °C/min
DSC Sensitivity0.001 mW
DSC Resolution0.01 mW
Temperature Repeatability±0.1 °C
Temperature Stability±0.01 °C
Temperature Resolution0.01 °C
Atmosphere ControlDual-gas (N₂/O₂) with digital mass flow meters (0–200 mL/min)
Power Supply220 V, 50 Hz
Operating Environment20–25 °C, 55–75% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-DSC-800
Temperature RangeAmbient to 800 °C (air-cooled)
Temperature Accuracy±0.1 °C
Heating/Cooling Rate1–80 K/min
Heat Flow Resolution0.1 μW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
ModelJB-PL
Measurement PrincipleSteady-State Guarded Hot Plate (ASTM C177, ISO 8302)
Thermal Conductivity Range0.010–5.000 W/(m·K)
Accuracy±3%
Repeatability±3%
Overall Dimensions (L×W×H)552 × 550 × 760 mm
OriginShanghai, China
Instrument TypeGuarded Hot Plate Analyzer
ComplianceASTM C177, ISO 8302, GB/T 10294
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin
OriginShanghai, China
ModelJB-DSC-600
Sample Capacity1
Temperature RangeAmbient to 600 °C
Heating/Cooling Rate0.1–100 K/min
DSC Heat Flow Range±500 mW
Sensitivity0.01 mW
Noise Level0.001 mW
Thermal Resolution0.001 mW
Temperature Repeatability±0.1 °C
Temperature Resolution0.1 °C
Gas Flow Control0–200 mL/min (0.2 MPa max)
InterfaceUSB
Display7-inch 24-bit color touchscreen LCD
Power SupplyAC 220 V, 50 Hz, 600 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-TGA-101
Temperature RangeAmbient to 1150 °C (optional upgrade to 1450 °C)
Temperature Accuracy±0.1 K
Balance Sensitivity0.01 mg
Heating/Cooling Rate1–80 °C/min
Balance Capacity1 mg–2 g (expandable to 30 g)
Isothermal Hold Time0–300 min
Atmosphere ControlDual-gas inlet with mass flow regulation (inert, oxidizing, reducing, static, dynamic)
Data InterfaceUSB
ComplianceASTM E1131, ISO 11358, USP <41>, GLP-ready software audit trail
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
ModelJB-3500S
OriginShanghai, China
Temperature RangeAmbient to 1100 °C
Heating Zone Length220 mm
Quartz Tube Dimensions440 mm (L) × 32 mm (ID)
Quartz Boat Options50 mm or 75 mm
Temperature Resolution0.01 °C
Temperature Stability±0.2 °C
Heating Rate0.1–40 °C/min
Gas Flow ControlDigital Mass Flow Controller (0–300 mL/min or 0–2000 mL/min)
Gas Pressure Rating0.2 MPa
Display7-inch 24-bit color LCD touchscreen
Communication InterfaceUSB
Sample CapacityUp to 3 specimens simultaneously
Exhaust Port Diameter12 mm
ComplianceGB/T 3515–2005, GB/T 13021–1991, GB/T 2951.41–2008, IEC 60811-4-1:2004
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJB Instruments
OriginShanghai, China
ModelTGA-1350
Temperature RangeAmbient to 1350 °C
Temperature Accuracy±0.1 K
Balance Sensitivity0.01 mg
Heating/Cooling Rate1–80 °C/min
Atmosphere ControlDual-gas inlet with mass flow regulation (inert, oxidizing, reducing, static, dynamic)
Balance Capacity1 mg–2 g (extendable to 30 g)
Isothermal Hold Time0–300 min
Cooling Time≤15 min (1000 °C → 100 °C)
InterfaceUSB 2.0
Power SupplyAC 220 V, 50 Hz
Dimensions (L×W×H)489 × 400 × 343 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin
ModelJB-DSC-500B
OriginShanghai, China
Temperature RangeAmbient to 500 °C
Temperature Accuracy±0.1 °C
Heating/Cooling Rate0.1–50 °C/min (heating), 0.1–10 °C/min (cooling)
DSC Sensitivity0.1 µW
DSC Range±500 mW
Temperature Resolution0.01 °C
DSC Accuracy±1%
Atmosphere ControlDual-gas (N₂/O₂) mass flow control with automatic switching
InterfaceUSB 2.0
Display7-inch 24-bit LED touch screen
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
OriginShanghai, China
ModelJB-DSC-800
Temperature RangeAmbient to 800 °C
Temperature Accuracy±0.1 °C
Heating/Cooling Rate1–80 K/min
Heat Flow Resolution0.1 μW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiubin Instruments
ModelDSC-300L
TypeHeat-Flux DSC
Temperature RangeAmbient to 600 °C (extended capability to 1050 °C per specification)
Heating/Cooling Rate0.1–100 K/min
Temperature Resolution0.01 °C
Temperature Repeatability±0.1 °C
DSC Sensitivity0.001 mW
DSC Resolution0.01 µW
DSC Dynamic Range±800 mW
Atmosphere ControlDual-gas auto-switching (N₂/O₂), plus dedicated purge gas line
Gas Flow Range0–300 mL/min
Gas Pressure Limit≤1 MPa
Display7-inch industrial-grade capacitive touchscreen
InterfaceStandard USB 2.0 with auto-reconnect protocol
ComplianceGB/T 19466.2–2004, GB/T 19466.3–2004, GB/T 19466.6–2009, ISO 11357-2:1999, ISO 11357-3:1999
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0