| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vanta RoHS Series |
| Application | Handheld / Portable |
| Industry-Specific Use | Electronics |
| Elemental Range | Mg–U |
| Detection Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vanta |
| Application | Handheld / Portable |
| Industry Type | General Purpose |
| Elemental Range | Mg to U |
| Detection Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DPO4050 |
| Detector | 25 mm² Silicon Drift Detector (SDD) |
| Excitation Source | High-Power Micro-Focus X-ray Tube (15–50 kV) |
| Cooling System | Peltier Thermoelectric Cooler (operable down to −35 °C) |
| Filter Set | 8-position Automatic Filter Wheel |
| Weight | <1.5 kg |
| Dimensions | 245 × 250 × 88 mm |
| Operating Temperature | −10 °C to +50 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Battery | Dual Hot-Swappable Li-ion Batteries |
| Display | High-Resolution Transflective Color Touchscreen |
| Data Storage | MicroSD card (≥100,000 spectra) |
| Connectivity | USB 2.0, Bluetooth 4.0 (Microsoft Mobile Device Center compatible) |
| Operating System | Windows CE 6.0 |
| Analysis Modes | Up to 25 User-Configurable Calibration Modes |
| Light Element Compensation | Integrated Barometric Pressure Sensor & Accelerometer for Atmospheric Correction |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DELTA DE2000 |
| Application | Handheld / Portable |
| Industry Focus | Non-Ferrous Metals & Precious Metals |
| Elemental Detection Range | Mg to U |
| Quantification Range | 1 ppm – 100 wt% |
| Energy Resolution | <139 eV (at Mn Kα) |
| Repeatability | ≤0.1% RSD |
| Detector Type | Si-Pin Semiconductor Detector |
| Excitation Source | Ta/Au Target X-ray Tube, 4 W Max Power |
| Operating Voltage | Up to 35 kV |
| Cooling System | Peltier Thermoelectric Cooler (Operable down to −35 °C) |
| Battery | Dual Hot-Swappable Li-ion Batteries |
| Display | High-Resolution Blanview Transflective Color Touchscreen |
| Data Storage | Removable SD Card |
| Compliance | ISO 9001 Certified, NATO AQAPI Qualified |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | DP6050 |
| Application | Handheld / Portable |
| Industry-Specific Use | Electronics |
| Elemental Range | Na (11) to U (92) |
| Quantification Range | 1 ppm to 99.9% |
| Energy Resolution | <130 eV |
| Repeatability | 0.1% |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | FASP-05B |
| Price | Upon Request |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DPO4000 |
| Element Range | Na (11) to U (92) |
| Detection Range | 1 ppm – 100% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Dimensions | 245 × 250 × 88 mm |
| Weight | <1.5 kg |
| Operating Temperature | −10 °C to 50 °C |
| Relative Humidity | 0–95% RH |
| Excitation Source | High-power micro-focus X-ray tube (15–40 kV) |
| Detector | 25 mm² Silicon Drift Detector (SDD) |
| Cooling | Peltier thermoelectric cooling (down to −35 °C) |
| Filters | 8-position automatic filter wheel |
| Battery | Dual hot-swappable Li-ion batteries |
| Display | High-resolution transflective color touchscreen |
| OS | Windows CE 6.0 |
| Data Storage | MicroSD card (≥100,000 spectra) |
| Connectivity | USB 2.0, Bluetooth 2.1 + EDR |
| Analytical Modes | Up to 25 user-configurable modes |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DCC2000 |
| Application | Handheld/Portable |
| Elemental Range | Mg (12) to U (92) |
| Concentration Range | 1 ppm – 100% |
| Energy Resolution | <150 eV |
| Repeatability | 0.1% |
| Dimensions | 245 × 250 × 88 mm |
| Weight | <1.5 kg |
| Operating Temperature | −10 °C to +50 °C |
| Humidity | 0–95% RH (non-condensing) |
| Excitation Source | High-power micro-focus X-ray tube (8–40 kV) |
| Detector | Si-PIN semiconductor detector with Peltier cooling (down to −35 °C) |
| Filter System | 8-position automatic filter changer |
| Power Supply | Dual hot-swappable Li-ion batteries |
| Display | High-resolution transflective color touchscreen |
| Data Storage | SD card (≥100,000 spectra) |
| Connectivity | USB 2.0, Bluetooth 2.1 (Microsoft-compatible stack) |
| OS | Windows CE 6.0 |
| Software | Delta PC Suite for remote control, report generation, and spectral library management |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DPO200 |
| Detector | 25 mm² SDD Silicon Drift Detector |
| Excitation Source | Micro-focus X-ray Tube (8–40 kV) |
| Cooling System | Peltier Thermoelectric Cooling (operable down to −35 °C) |
| Filter Set | 8-position automatic filter changer |
| Display | High-resolution transflective color touchscreen |
| Weight | <1.5 kg |
| Dimensions | 245 × 250 × 88 mm |
| Operating Temperature | −10 °C to 50 °C |
| Relative Humidity | 0–95% non-condensing |
| Battery | Dual hot-swappable Li-ion batteries |
| Data Storage | SD card (≥100,000 spectra) |
| Connectivity | USB 2.0, Bluetooth v2.1 + EDR |
| OS | Windows CE 6.0 |
| Software | Olympus Delta PC Suite (remote control, report generation, spectral review) |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vanta GX |
| Form Factor | Benchtop |
| Industry Application | Non-Ferrous Metals |
| Elemental Range | Mg (12) – U (92) |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV (Mn Kα) |
| Detector | Silicon Drift Detector (SDD) |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DE2000 |
| Application | Handheld / Portable |
| Industry-Specific Use | Non-Ferrous & Ferrous Metals |
| Elemental Range | Mg to U |
| Quantification Range | 1 ppm – 99.9 wt% |
| Energy Resolution | <140 eV (at Mn Kα) |
| Repeatability | ≤0.1% RSD (for major alloying elements under controlled conditions) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Niton XL2 700 |
| Portability | Handheld / Portable |
| Elemental Analysis Range | Na (Z=11) to U (Z=92) |
| Detection Limit | Sub-ppm to low-ppm (matrix-dependent, 300 s measurement) |
| Energy Resolution | <140 eV at Mn Kα |
| Repeatability | ≤0.1% RSD (for major elements in homogeneous standards) |
| Detector | Peltier-cooled Si-PIN |
| X-ray Tube | Au-anode, 40 kV / 50 µA |
| Measurement Spot Size | ≥4 mm × 4 mm |
| Data Storage | 4,000+ spectra + quantitative results |
| Battery Life | 6–12 h (dual rechargeable Li-ion) |
| Dimensions | 248 × 273 × 95 mm |
| Weight | 1.4 kg |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DCC-4000 |
| Portability | Handheld |
| Application Domain | Soil & Atmospheric Environmental Monitoring |
| Elemental Range | K (19) to U (92) |
| Detection Limit | 1 ppm |
| Quantification Range | 1 ppm – 100% |
| Energy Resolution | <140 eV (at Mn Kα) |
| Repeatability | ±0.1% RSD |
| Dimensions | 245 × 250 × 88 mm |
| Weight | <1.5 kg |
| Operating Temperature | −10 °C to +50 °C |
| Relative Humidity | 0–95% non-condensing |
| Excitation Source | High-power micro-focus X-ray tube (15–40 kV) |
| Detector | Si-PIN semiconductor detector with Peltier cooling to −35 °C |
| Filter System | 8-position automatic filter changer |
| Data Storage | MicroSD card (≥100,000 spectra) |
| Connectivity | USB 2.0, Bluetooth v2.1 + EDR |
| Operating System | Windows CE 6.0 |
| Battery | Dual hot-swappable Li-ion packs |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DP2000 |
| Application | Handheld/Portable |
| Industry Type | Non-Ferrous Metals |
| Elemental Range | Na (11) – U (92) |
| Concentration Range | 1 ppm – 100% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | RLTD-05 / RLTD-10 |
| Pricing | Available Upon Request |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DPO2000 |
| Application | Handheld/Portable |
| Industry Type | Non-Ferrous Metals |
| Elemental Range | Mg (12) – U (92) |
| Detection Range | 1 ppm – 100% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vanta Series |
| Application | Handheld/Portable |
| Industry-Specific Use | Soil & Environmental Monitoring |
| Elemental Range | Mg–U |
| Detection Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Brand | Belec |
|---|---|
| Origin | Germany |
| Model | Belec Compact-Port |
| Instrument Type | Portable / Mobile |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 750 mm |
| Grating Grooves | 3600 lines/mm |
| Wavelength Range | 120–780 nm |
| Number of Channels | 18 |
| Weight | 17 kg |
| Optional Spark Probes | Argon “Special” Probe, Argon “Dedicated” Probe, Air Probe |
| Multi-Matrix Capability | Up to 6 base materials with 36 total elemental channels |
| Software | Belec proprietary analysis software (10+ language options, including full Chinese UI) |
| Hybrid Configuration | Compatible with external spark stand for benchtop operation |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | FASP-01 |
| Pricing | Available Upon Request |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FASP-ECO |
| Pricing | Available Upon Request |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | XRD-Terra |
| Instrument Type | Powder X-ray Diffractometer |
| Power Stability | < 0.0001 (unitless relative stability) |
| Dimensions | 485 × 392 × 192 mm |
| Weight | 14.5 kg (including integrated battery pack) |
| Sample Mass Requirement | ~15 mg |
| Measurement Time | ≤ 3 minutes per sample |
| Detector | 2D CCD-based area detector |
| Geometry | Transmission-mode XRD |
| Integrated Capability | Simultaneous XRD and XRF analysis |
| Cooling | Peltier electronic cooling |
| Environmental Rating | IP54-equivalent (dust- and splash-resistant), shock-damped chassis |
| Compliance | NASA Patent US7113265B2 |
| Software Interface | WiFi-enabled remote acquisition and real-time data streaming |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | X-5000a |
| Application | Field-portable soil and sediment analysis |
| Elemental Range | Na to U |
| Detection Range | 1 ppm to 100% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Detector Type | Silicon Drift Detector (SDD) |
| Compliance | EPA Method 6200, ISO/DIS 13196, TCLP, RCRA 8 Metals, ASTM D6729, OSHA/NIOSH/NIH/HUD guidelines |
| Certifications | ISO 9001, NATO AQAPI-110 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Niton XL3T700 |
| Form Factor | Handheld / Portable |
| Elemental Range | Na (Z=11) to U (Z=92) |
| Detection Limit | 1 ppm (typical for heavy metals in homogeneous matrices) |
| Energy Resolution | <140 eV at Mn Kα |
| Repeatability | ≤0.1% RSD (for major elements under controlled conditions) |
| X-ray Tube | Rh anode, 50 kV, 2 W |
| Detector | High-performance Si-PIN |
| Operating Temperature | –10 °C to 50 °C |
| Weight | <1.3 kg |
| Dimensions | 244 × 230 × 95.5 mm |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | DP4050 |
| Application | Handheld/Portable |
| Industry-Specific Use | Soil & Environmental Monitoring |
| Elemental Range | Na (11) to U (92) |
| Detection Range | 1 ppm to 100% |
| Energy Resolution | <130 eV |
| Repeatability | ±0.1% |
Show next