| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | Smartchem 600 |
| Product Type | Discrete Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Cup | 300 µL |
| Sample Capacity | 126 positions |
| Reagent Positions | 600 |
| Cuvette Path Length | 10 mm |
| Light Source | LED and Halogen Lamp |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | PROXIMAs |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Volume | 0.5 mL |
| Reagent Positions | 104 |
| Flow Cell Path Length | 5–50 mm |
| Light Source | Halogen Lamp |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | PROXIMA |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 104-position turntable autosampler (optional 360-position XYZ autosampler) |
| Reagent Positions | 36 |
| Flow Cell Path Length | 50 mm |
| Light Source | Tungsten-Halogen Lamp |
| Detection Limit | Sub-ppb level |
| Throughput | Up to 120 samples/hour |
| Pump Tubing | 52 channels (2 × 26) |
| Flow Rate Range | 50–3000 µL/min |
| A/D Resolution | 24-bit (1.68 × 10⁷) |
| Dimensions (Main Unit) | 75 × 50 × 42 cm |
| Weight (Main Unit) | 45 kg |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | SmartChem 200 |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Test | 300 µL |
| Sample Positions | 126 |
| Reagent Positions | 200 (including refrigerated slots) |
| Cuvette Path Length | 10 mm |
| Light Source | LED and Halogen Tungsten Lamp (6 V / 10 W, 2000 h lifetime) |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | FUTURA |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 200 positions / 5 racks |
| Reagent Positions | 104 or 360 |
| Flow Cell Path Length | 50 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Niton XLt 797RWY |
| Instrument Type | Portable |
| X-ray Tube Power | 400 W |
| Detectable Elements | Boron (B, Z=5) to Uranium (U, Z=92) |
| Detector Linearity Range | kCPS |
| Beryllium Window Thickness | µm |
| Detector | Peltier-cooled Si-PIN |
| Energy Resolution | <250 eV (FWHM at Mn Kα, 2σ confidence) |
| Weight | 1.4 kg |
| Dimensions | 248 × 273 × 95 mm |
| Battery Life | 6–12 h |
| Operating Voltage | 40 kV / 50 µA max |
| Filter System | Dual-filter configuration (Filter 2 optimized for Cl and Cr in halogen-free screening) |