| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vanta RoHS Series |
| Application | Handheld / Portable |
| Industry-Specific Use | Electronics |
| Elemental Range | Mg–U |
| Detection Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vanta |
| Application | Handheld / Portable |
| Industry Type | General Purpose |
| Elemental Range | Mg to U |
| Detection Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DPO4050 |
| Detector | 25 mm² Silicon Drift Detector (SDD) |
| Excitation Source | High-Power Micro-Focus X-ray Tube (15–50 kV) |
| Cooling System | Peltier Thermoelectric Cooler (operable down to −35 °C) |
| Filter Set | 8-position Automatic Filter Wheel |
| Weight | <1.5 kg |
| Dimensions | 245 × 250 × 88 mm |
| Operating Temperature | −10 °C to +50 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Battery | Dual Hot-Swappable Li-ion Batteries |
| Display | High-Resolution Transflective Color Touchscreen |
| Data Storage | MicroSD card (≥100,000 spectra) |
| Connectivity | USB 2.0, Bluetooth 4.0 (Microsoft Mobile Device Center compatible) |
| Operating System | Windows CE 6.0 |
| Analysis Modes | Up to 25 User-Configurable Calibration Modes |
| Light Element Compensation | Integrated Barometric Pressure Sensor & Accelerometer for Atmospheric Correction |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ZP15UV |
| Price Range | USD 700–1,400 |
| Pure Water Grade | ASTM Type I |
| Resistivity | 18.2 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <3 ppb |
| Microbial Count / Endotoxin | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Flow Rate | 15 L/h (25°C) |
| UV Wavelengths | 185 nm + 254 nm |
| Integrated Final Filtration | 0.22 µm hydrophilic membrane |
| System Architecture | Dual-Outlet (RO Water + Ultrapure Water) |
| Control Interface | Backlit LCD touchscreen with real-time monitoring and alarm logic |
| In-line Recirculation | Yes, with programmable frequency |
| Sanitization | Manual or automated chemical disinfection protocol |
| Compliance | Meets ASTM D1193-20, ISO 3696:1987, CLSI EP22-A, and supports GLP/GMP audit trails when paired with optional data logging module |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ZP15DI |
| Output Flow Rate | 15 L/h at 25°C |
| Resistivity | ≥18.2 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <3 ppb |
| Microbial Count | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Brand | Ion Science |
|---|---|
| Origin | United Kingdom |
| Model | Tiger |
| Instrument Type | Portable VOC Detector |
| Detection Principle | Photoionization Detection (PID) |
| Detection Range | 1 ppb – 20,000 ppm |
| Resolution | 1 ppb |
| Accuracy | ±5% of reading |
| Response Time | <2 seconds |
| Sensor Technology | Patented ultra-low-power PID lamp with humidity-resistant electrode design |
| Operating Humidity Range | Up to 99% RH (non-condensing) |
| Battery Life | Up to 24 hours continuous operation |
| Data Interface | USB-C for real-time streaming and batch download |
| Compliance | CE, UKCA, ATEX II 2G Ex ia IIC T4 Ga, IECEx ia IIC T4 Ga, UL Listed Class I, Division 1, Groups A–D |
| Origin | Fujian, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | Auto GDA-72 |
| Pricing | Available Upon Request |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DELTA DE2000 |
| Application | Handheld / Portable |
| Industry Focus | Non-Ferrous Metals & Precious Metals |
| Elemental Detection Range | Mg to U |
| Quantification Range | 1 ppm – 100 wt% |
| Energy Resolution | <139 eV (at Mn Kα) |
| Repeatability | ≤0.1% RSD |
| Detector Type | Si-Pin Semiconductor Detector |
| Excitation Source | Ta/Au Target X-ray Tube, 4 W Max Power |
| Operating Voltage | Up to 35 kV |
| Cooling System | Peltier Thermoelectric Cooler (Operable down to −35 °C) |
| Battery | Dual Hot-Swappable Li-ion Batteries |
| Display | High-Resolution Blanview Transflective Color Touchscreen |
| Data Storage | Removable SD Card |
| Compliance | ISO 9001 Certified, NATO AQAPI Qualified |
| Origin | Fujian, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | M36 |
| Pricing | Available Upon Request |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | DP6050 |
| Application | Handheld / Portable |
| Industry-Specific Use | Electronics |
| Elemental Range | Na (11) to U (92) |
| Quantification Range | 1 ppm to 99.9% |
| Energy Resolution | <130 eV |
| Repeatability | 0.1% |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | WL30D |
| Price Range | USD 14,000 – 70,000 |
| Product Type | Pressure-Based Water Level Sensor |
| Probe Interchangeability | Water Level / Casing Length / Well Depth Probes |
| Operating Modes | Static Level, Drawdown Monitoring, Full-Depth Measurement, Casing Length Verification, Auto-Triggered Sampling Integration |
| Brand | VWR |
|---|---|
| Origin | United Kingdom |
| Model | 256-026 |
| Flow Rate Range | 0.5 mL to 9999.9 mL per dispense |
| Dispensing Speed | 2.1–22.0 mL/s (adjustable) |
| Accuracy | ±1.5% (5 mL), ±1.0% (10 mL), ±0.7% (25 mL) |
| Repeatability | ±1.75% (5 mL), ±1.0% (10 mL), ±0.5% (25 mL) |
| Tubing ID Options | 3 mm, 8 mm |
| Dimensions (L×W×H) | 290 × 250 × 150 mm |
| Weight | 7 kg |
| Control Interface | LCD display with touch-sensitive buttons |
| Operating Modes | Manual, foot-pedal, time-interval auto-dispense, ramped (slow-fast-slow) sequence |
| Memory | Calibration and volume presets retained after power-off |
| Compatible Tubing | GP silicone tubing (Cat. No. 256-027: 3×7 mm |
| 256-028 | 5×9 mm |
| 256-029 | 8×12 mm) |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | FASP-05B |
| Price | Upon Request |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DPO4000 |
| Element Range | Na (11) to U (92) |
| Detection Range | 1 ppm – 100% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Dimensions | 245 × 250 × 88 mm |
| Weight | <1.5 kg |
| Operating Temperature | −10 °C to 50 °C |
| Relative Humidity | 0–95% RH |
| Excitation Source | High-power micro-focus X-ray tube (15–40 kV) |
| Detector | 25 mm² Silicon Drift Detector (SDD) |
| Cooling | Peltier thermoelectric cooling (down to −35 °C) |
| Filters | 8-position automatic filter wheel |
| Battery | Dual hot-swappable Li-ion batteries |
| Display | High-resolution transflective color touchscreen |
| OS | Windows CE 6.0 |
| Data Storage | MicroSD card (≥100,000 spectra) |
| Connectivity | USB 2.0, Bluetooth 2.1 + EDR |
| Analytical Modes | Up to 25 user-configurable modes |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DCC2000 |
| Application | Handheld/Portable |
| Elemental Range | Mg (12) to U (92) |
| Concentration Range | 1 ppm – 100% |
| Energy Resolution | <150 eV |
| Repeatability | 0.1% |
| Dimensions | 245 × 250 × 88 mm |
| Weight | <1.5 kg |
| Operating Temperature | −10 °C to +50 °C |
| Humidity | 0–95% RH (non-condensing) |
| Excitation Source | High-power micro-focus X-ray tube (8–40 kV) |
| Detector | Si-PIN semiconductor detector with Peltier cooling (down to −35 °C) |
| Filter System | 8-position automatic filter changer |
| Power Supply | Dual hot-swappable Li-ion batteries |
| Display | High-resolution transflective color touchscreen |
| Data Storage | SD card (≥100,000 spectra) |
| Connectivity | USB 2.0, Bluetooth 2.1 (Microsoft-compatible stack) |
| OS | Windows CE 6.0 |
| Software | Delta PC Suite for remote control, report generation, and spectral library management |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DPO200 |
| Detector | 25 mm² SDD Silicon Drift Detector |
| Excitation Source | Micro-focus X-ray Tube (8–40 kV) |
| Cooling System | Peltier Thermoelectric Cooling (operable down to −35 °C) |
| Filter Set | 8-position automatic filter changer |
| Display | High-resolution transflective color touchscreen |
| Weight | <1.5 kg |
| Dimensions | 245 × 250 × 88 mm |
| Operating Temperature | −10 °C to 50 °C |
| Relative Humidity | 0–95% non-condensing |
| Battery | Dual hot-swappable Li-ion batteries |
| Data Storage | SD card (≥100,000 spectra) |
| Connectivity | USB 2.0, Bluetooth v2.1 + EDR |
| OS | Windows CE 6.0 |
| Software | Olympus Delta PC Suite (remote control, report generation, spectral review) |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vanta GX |
| Form Factor | Benchtop |
| Industry Application | Non-Ferrous Metals |
| Elemental Range | Mg (12) – U (92) |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV (Mn Kα) |
| Detector | Silicon Drift Detector (SDD) |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DE2000 |
| Application | Handheld / Portable |
| Industry-Specific Use | Non-Ferrous & Ferrous Metals |
| Elemental Range | Mg to U |
| Quantification Range | 1 ppm – 99.9 wt% |
| Energy Resolution | <140 eV (at Mn Kα) |
| Repeatability | ≤0.1% RSD (for major alloying elements under controlled conditions) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Niton XL2 700 |
| Portability | Handheld / Portable |
| Elemental Analysis Range | Na (Z=11) to U (Z=92) |
| Detection Limit | Sub-ppm to low-ppm (matrix-dependent, 300 s measurement) |
| Energy Resolution | <140 eV at Mn Kα |
| Repeatability | ≤0.1% RSD (for major elements in homogeneous standards) |
| Detector | Peltier-cooled Si-PIN |
| X-ray Tube | Au-anode, 40 kV / 50 µA |
| Measurement Spot Size | ≥4 mm × 4 mm |
| Data Storage | 4,000+ spectra + quantitative results |
| Battery Life | 6–12 h (dual rechargeable Li-ion) |
| Dimensions | 248 × 273 × 95 mm |
| Weight | 1.4 kg |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DCC-4000 |
| Portability | Handheld |
| Application Domain | Soil & Atmospheric Environmental Monitoring |
| Elemental Range | K (19) to U (92) |
| Detection Limit | 1 ppm |
| Quantification Range | 1 ppm – 100% |
| Energy Resolution | <140 eV (at Mn Kα) |
| Repeatability | ±0.1% RSD |
| Dimensions | 245 × 250 × 88 mm |
| Weight | <1.5 kg |
| Operating Temperature | −10 °C to +50 °C |
| Relative Humidity | 0–95% non-condensing |
| Excitation Source | High-power micro-focus X-ray tube (15–40 kV) |
| Detector | Si-PIN semiconductor detector with Peltier cooling to −35 °C |
| Filter System | 8-position automatic filter changer |
| Data Storage | MicroSD card (≥100,000 spectra) |
| Connectivity | USB 2.0, Bluetooth v2.1 + EDR |
| Operating System | Windows CE 6.0 |
| Battery | Dual hot-swappable Li-ion packs |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DP2000 |
| Application | Handheld/Portable |
| Industry Type | Non-Ferrous Metals |
| Elemental Range | Na (11) – U (92) |
| Concentration Range | 1 ppm – 100% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | RLTD-05 / RLTD-10 |
| Pricing | Available Upon Request |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DPO2000 |
| Application | Handheld/Portable |
| Industry Type | Non-Ferrous Metals |
| Elemental Range | Mg (12) – U (92) |
| Detection Range | 1 ppm – 100% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vanta Series |
| Application | Handheld/Portable |
| Industry-Specific Use | Soil & Environmental Monitoring |
| Elemental Range | Mg–U |
| Detection Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |