Soil Detector
Filter
Showing 241–270 of 499 results
| Brand | Loobo |
|---|---|
| Model | LB-TR008 |
| Material | AISI 304 Stainless Steel |
| Sampling Depths | 1 m, 1.5 m, 2 m |
| Sample Length per Insertion | 15–20 cm |
| Depth Scale | Marked at 100 mm intervals |
| Weight | 5 kg |
| Configuration | Modular threaded assembly (bit, extension tube, handle) |
| Application | Field-based manual soil core sampling |
| Compliance | Designed for ISO 10381-1 (soil sampling principles), ASTM D1586 (standard penetration test reference geometry), and GLP-aligned sample integrity protocols |
| Brand | MAE |
|---|---|
| Origin | Italy |
| Model | C313SEV |
| Output Voltage Range | ±50 V, ±100 V, ±250 V, ±500 V, ±800 V |
| Max Output Current | 5 A |
| Max Output Power | 250 W |
| Current Resolution | ±0.2 µA |
| Potential Measurement Range | ±25 V |
| Input Impedance | 2.5 MΩ |
| Potential Resolution | ±1.5 µV (within ±25 V) |
| Sampling Interval | 0.25 s |
| Noise Reduction | 2–10 sample averaging |
| Built-in Battery | 12 V / 12 Ah |
| Operating Temperature | −20 °C to +80 °C |
| Enclosure Rating | IP42 |
| Display | 7" TFT LCD touchscreen |
| Data Storage | Internal SD card (~3 GB), USB port (included) |
| Data Formats | TSV, CSV, DAT |
| Communication Ports | LAN, USB, VGA |
| Dimensions | 49 × 19 × 26.4 cm |
| Weight | 9.6 kg |
| Operating System | Embedded Windows |
| Language Support | English, Italian |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Manual Environmental Soil Sampling Kit |
| Price | Available Upon Request |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | 10HS |
| Sensor Type | Capacitive (Frequency Domain) |
| Operating Voltage | 3–15 VDC |
| Output Signal | 300–1250 mV (ratiometric, voltage-independent) |
| Measurement Volume | 1320 cm³ |
| Probe Length | 10 cm |
| Dimensions | 16.0 × 3.3 × 0.8 cm |
| Standard Cable Length | 5 m (custom up to 40 m) |
| Connector | 3.5 mm stereo jack or tinned 3-wire lead |
| Operating Temperature | –40 to +50 °C |
| Resolution | 0.0008 m³/m³ (0.08% VWC) in mineral soils (0–50% VWC) |
| Accuracy (mineral soils, standard calibration) | ±0.03 m³/m³ or ±3% VWC (EC < 10 dS/m) |
| Accuracy (soil-specific calibration) | ±0.02 m³/m³ or ±2% VWC |
| Dielectric Range | εₐ = 1–80 |
| Measurement Time | 10 ms |
| Compliance | ISO 9001:2015, CE (2014/30/EU, 2011/65/EU), EN 61326-1:2013, EN 50581:2012 |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | VSA |
| Instrument Type | Water Activity / Matric Potential Analyzer |
| Measurement Principle | Dynamic Dew Point Isotherm (DDI) |
| Temperature Range | 15–50 °C |
| Water Activity Range | 0.03–0.950 aw |
| Matric Potential Range | −10 to −475 MPa |
| Resolution | 0.0001 aw (0.01% RH), ±0.1 °C |
| Accuracy | ±0.005 aw, ±1 MPa or ±1%, ±0.01 °C |
| Repeatability | ±0.003 aw |
| Sample Capacity | 14 mL |
| Dimensions | 38.1 × 26.7 × 30.5 cm |
| Weight | 14.9 kg |
| Power | 110–220 V AC, 50/60 Hz |
| Interface | USB |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | Drain Gauge G3 |
| Instrument Type | Multifunctional Soil Infiltration and Percolation Monitoring System |
| Compliance | ISO 9001:2015, EM ISO/IEC 17050:2010 (CE Marked) |
| Power Supply | 3.6–15.0 VDC |
| Communication | DDI Serial or SDI-12 |
| Weight | 14 kg (PVC DCT), 20 kg (Stainless Steel DCT) |
| Standard Cable Length | 10.0 m (optional: 20.0 m or 40.0 m) |
| Operating Temperature | 0–60 °C |
| Storage Tube Dimensions | 81.3 cm L × 11.5 cm OD |
| Drain Collection Tube (DCT) Dimensions | 62.5 cm L × 25.4 cm ID × 26.4 cm OD |
| Inlet Pipe | 180.0 cm standard (custom lengths available), 6 cm OD, Schedule 40 PVC |
| Sample Extraction Tube | 5.0 m standard (customizable), 6 mm OD, Polyethylene |
| Sensor Dimensions | 3.4 cm Ø × 9 cm L |
| Cable Diameter | 4.20 mm |
| Connector | Stereo jack or 3-pin tinned bare wire |
| Wire Gauge | 22 AWG / 24 AWG twisted pair |
| Drain Depth Resolution | 0.2 mm (lower section), 1 mm (upper section) |
| Drain Depth Range | 0–100 mm (lower: 0–61 mm |
| upper | 61–100 mm) |
| Conductivity Range | 0–120 dS/m |
| Conductivity Resolution | 0.001 dS/m |
| Conductivity Accuracy | ±0.01 dS/m or ±10% (whichever is greater) |
| Temperature Range | –40 to +60 °C |
| Temperature Accuracy | ±1 °C |
| Temperature Resolution | 0.1 °C |
| Drain Depth Accuracy | ±1.4 mm |
| Digital Input Voltage (High) | 2.8–5.0 V |
| Digital Input Voltage (Low) | –0.3–0.8 V |
| Digital Output (High) | ~3.6 V |
| Slew Rate | ≥1 V/ms |
| Current Draw | 0.5–8.0 mA (active), ~0.3 mA (standby) |
| Startup Time | DDI ≤200 ms |
| Measurement Time | ~150 ms |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer | METER Group, Inc. (formerly Decagon Devices) |
| Model | EC-5 |
| Measurement Principle | High-Frequency Capacitance (5 MHz) |
| Volumetric Water Content (VWC) Range | 0–100% |
| Accuracy (Mineral Soils, EC < 8 dS/m) | ±3% VWC (±2% with soil-specific calibration) |
| Resolution | 0.1% VWC (mineral soils), 0.25% VWC (growing media) |
| Measurement Time | 10 ms |
| Excitation Voltage | 2.5–3.6 V DC @ 10 mA |
| Output Signal | 10–50% of excitation voltage (250–1,250 mV at 2.5 V excitation) |
| Operating Temperature | −40 to +60 °C |
| Probe Length | 5 cm |
| Dimensions | 8.9 × 1.8 × 0.7 cm |
| Cable Length | Standard 5 m (customizable up to 40 m) |
| Connector | 3.5 mm stereo jack or 3-conductor tinned lead wires |
| Compatibility | METER ZL6, EM50/EM60 data loggers |
| Compliance | ISO 9001:2015, ISO/IEC 17050:2010 (CE Mark), EU Directive 2014/30/EU (EMC), 2011/65/EU (RoHS), EN 61326-1:2013, EN 50581:2012 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1500F2 |
| Instrument Type | Soil Water Potential & Moisture Analyzer |
| Operating Voltage | 110–120 V AC, 60 Hz / 220–230 V AC, 50 Hz |
| Water Potential Range | 0 to −15 bar (0 to −1.5 MPa) |
| Accuracy | ±0.1 kPa (±0.001 bar) |
| Relative Humidity Range | 0–90% RH, non-condensing |
| 15-bar Chamber Dimensions | Depth 10 cm, Diameter 30 cm, Capacity: 4 ceramic plates, up to 48 soil cores (5.7 cm diameter) |
| 15-bar Chamber Weight | 36.1 kg |
| 5-bar Chamber Dimensions | Depth 22 cm, Diameter 30 cm, Capacity: 4 ceramic plates, up to 48 soil cores (5.7 cm diameter) |
| 5-bar Chamber Weight | 20.4 kg |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | GS1 |
| Instrument Type | Volumetric Water Content (VWC) Sensor |
| Measurement Principle | 70 MHz Capacitance-Based Dielectric Permittivity Sensing |
| Operating Temperature | -40 to 50 °C |
| Measurement Range | 0–57% VWC |
| Accuracy | ±0.03 m³/m³ (±3%) for typical soils (EC < 8 dS/m) |
| Resolution | 0.001 m³/m³ (0.1%) |
| Measurement Time | 10 ms |
| Power Supply | 3.0–15 VDC @ ≤15 mA |
| Output Signal | 1000–2500 mV (analog, linear voltage-to-VWC) |
| Sensor Dimensions | 5.1 × 2.4 × 2.1 cm |
| Connector | 3.5 mm stereo jack or tinned 3-wire lead |
| Compatible Data Loggers | METER Em50 series, ProCheck, Campbell Scientific (CSI) loggers |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | HYPROP 3 |
| Instrument Type | Multifunctional Soil Hydraulic Property Analyzer |
| Measurement Principle | Dual-sensor tensiometric gravimetric method |
| Sample Volume | 250 cm³ (standard) / 100 cm³ (optional) |
| Pressure Range | +0.3 to –100 kPa (cavitation-delayed up to –400 kPa) |
| Temperature Range | –20 to +60 °C |
| Pressure Accuracy | ±0.1 kPa (0.3 to –100 kPa, zero-calibrated) |
| Temperature Accuracy | ±0.4 K (–10 to +30 °C) |
| Pressure Resolution | 0.001 kPa |
| Temperature Resolution | 0.01 °C |
| Measurement Interval (default) | 10 min |
| Max Concurrent Samples | 20 (multi-balance mode) |
| Power Supply | 6–18 V DC, typical 15 mA (<200 mA peak) |
| Communication | USB (HYPROP USB Adapter or USB Hub with HYPROP-VARIOS-CONNECTOR) |
| Operating System | Windows 10 or later |
| Sensor Housing Material | POM reinforced with glass fiber |
| Tensiometer Ceramic Cup | Sintered Al₂O₃, 5 mm diameter |
| Tensiometer Stem | Acrylic glass, 5 mm OD, 24 mm (short) / 49 mm (long) |
| PU Tubing | 6 mm OD / 4 mm ID / 0.3 m length |
| IP Rating | IP65 (electrical connectors) |
| Chemical Resistance | pH 3–10 |
| Operating Ambient | 10–30 °C |
| Balance Compatibility | LABROS high-precision balance (2200 g capacity, 0.01 g readability/repeatability/linearity) |
| Software | METER SoilView-Analysis (integrated HYPROP 3 + WP4C data fusion) |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | KSAT |
| Instrument Type | Soil Water Potential & Moisture Analyzer |
| Measurement Range | 0.01–5,000 cm/d |
| Porous Plate Hydraulic Conductivity (Ks) | 14,000 cm/d |
| Pressure Sensor Accuracy | ±1 Pa (0.01 cm H₂O) |
| Temperature Sensor Accuracy | ±0.2 °C |
| Sample Ring Volume | 250 mL (Ø80 mm × H50 mm), with optional 100 mL adapter |
| Typical Statistical Error under Constant Head/Constant Flow Conditions | ~2% |
| Software Requirements | Windows 7 or later, Microsoft .NET Framework 3.5 |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model(s) | KSAT, HYPROP 2, WP4C, TEROS 31, AQUALAB VSA, PARIO |
| Instrument Type | Soil Water Content & Water Potential Analyzer |
| Measurement Range (Combined) | +20 hPa to –475 MPa (water potential), 0.01–5,000 cm/d (saturated hydraulic conductivity), 63–2 µm (particle size distribution) |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Mini Disk |
| Instrument Type | Soil Water Potential & Hydraulic Conductivity Analyzer |
| Height | 32.7 cm |
| Diameter (body) | 3.1 cm |
| Sintered Stainless Steel Disc Diameter | 4.5 cm |
| Disc Thickness | 3 mm |
| Upper Chamber Volume | 40.0 mL |
| Lower Chamber Volume | 95.0 mL |
| Adjustable Suction Range | 0.5–7 cm |
| Compliance | ASTM D3385, ISO 28580, USP <1058> (for method validation in environmental hydrology) |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | PARIO Plus |
| Instrument Type | Multi-Function Soil Analyzer |
| Particle Size Range | 2–63 µm |
| Measurement Principle | Extended Integrated Suspension Pressure Method (ISP+) based on Stokes’ Law |
| Accuracy (Mass Fraction) | ±1.0% |
| Pressure Sensor Accuracy | ±1.0 Pa, Resolution: ±0.1 Pa |
| Measurement Interval | 10 s |
| Typical Sample Mass | 25–50 g per 1 L suspension |
| Measurement Duration | ~2.5 h |
| Operating Temperature | 15–35 °C (optimal at 20 °C), max ΔT during measurement: ±1.5 °C |
| Suspension Volume | 1000 mL |
| Glass Column Dimensions | H 450 mm, ID 59 mm, OD 67.5 mm, borosilicate glass 3.3 |
| Device Dimensions | H 293 mm, Ø 80 mm, housing material: POM + stainless steel |
| Power Supply | USB 5 V / 100 mA |
| PC Compatibility | Windows 10 |
| Compliance | ISO 9001:2015, ISO/IEC 17050:2010 (CE Mark) |
| Required Ancillary Measurements | Dry mass of subsample, sand content (wet sieving), mass of dispersing salt in suspension |
| Brand | METER |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PARIO Plus |
| Price | USD 8,400 (FOB) |
| Particle Size Range | 2–63 µm |
| Estimated Mass Fraction Error | ±1.0% |
| Pressure Measurement Accuracy | ±1.0 Pa |
| Resolution | ±0.1 Pa |
| Measurement Interval | 10 s |
| Typical Suspension Volume | 1,000 mL |
| Temperature Operating Range | 15–35 °C (Optimal: 20 °C |
| Max ΔT During Measurement | ±1.5 °C) |
| Sample Mass | 25–50 g per 1 L suspension |
| Instrument Height | 293 mm |
| Diameter | 80 mm |
| Material | POM polymer & stainless steel |
| Glass Cylinder Dimensions | H 450 mm, ID 59 mm, OD 67.5 mm, Volume 1,000 cm³ |
| Material | Borosilicate Glass 3.3 |
| Power Supply | USB 5 V / 100 mA |
| Interface | USB 2.0 |
| Compliance | EM Directive 2014/30/EU, EN ISO/IEC 17050:2010 (CE Mark) |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | SATURO |
| Instrument Type | Automated Dual-Head Infiltration Analyzer for Saturated Hydraulic Conductivity (Kfs) Measurement |
| Infiltration Rate Range | 0.0038–115 cm/hr |
| Resolution | 0.0038 cm/hr |
| Accuracy | ±5% of reading |
| Pressure Head Range | 0–40 cm |
| Water Level Control | Maintained at 5 cm |
| Operating Temperature | 0–50 °C |
| Power Input | 18 V DC, 2.2 A (18–24 V DC supported) |
| Output Interface | USB |
| Standard Head Dimensions | Total Height 18.3 cm, Internal Diameter 17.2 cm |
| Borehole Head Dimensions | Total Height 28.78 cm, Internal Diameter 8.26 cm |
| Embedded Ring ID | 14.4 cm, Insertion Depth: 5 or 10 cm |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | TEMPOS |
| Type | Multiparameter Soil Thermal Property Analyzer |
| Compliance | ASTM D5334, IEEE Std 442, ISO 9001:2015, EN 61326-1:2013, CISPR 22 |
| Operating Temperature (Controller) | 0–50 °C |
| Sensor Operating Range | −50–150 °C |
| Power Supply | 5 × AA batteries (alkaline or rechargeable) |
| Battery Life | >250 high-power measurements |
| Data Storage | Flash memory, 2,048 full measurement records (raw + processed) |
| Display | Color LCD, 5.5 cm × 4.0 cm |
| Controller Dimensions | 18.5 × 10 × 3.5 cm |
| Carry Case | Ergonomic molded polymer, 37 × 30 × 10.5 cm |
| Interface | DB-15 sensor port |
| Connectivity | Mini-USB for data export |
| Temperature Resolution | ±0.001 °C |
| Measurement Cycle | Equilibration → Heating → Cooling, completed in ≤60 s |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | TEROS 12 |
| Measurement Principle | Frequency Domain Reflectometry (FDR) at 70 MHz |
| Output Options | SDI-12 or DDI Serial Interface |
| Volumetric Water Content Range | 0.00–0.70 m³/m³ (mineral soils), 0.0–1.0 m³/m³ (non-soil media) |
| EC Range | 0–20 dS/m |
| Temperature Range | −40 to +60 °C |
| Accuracy (VWC) | ±0.03 m³/m³ (±3% VWC) with generic mineral soil calibration |
| Resolution (VWC) | 0.001 m³/m³ |
| Resolution (EC) | 0.001 dS/m |
| Resolution (Temp) | 0.1 °C |
| Probe Length | 5.5 cm |
| Sensor Dimensions | 9.4 × 2.4 × 7.5 cm |
| Measurement Volume | 1010 cm³ |
| Typical Power Consumption | 3.6 mA during measurement, 0.03 mA in standby |
| Cable Length | Standard 5 m (custom up to 75 m) |
| Compliance | ISO 9001:2015, CE (2014/30/EU & 2011/65/EU), EN 61326-1:2013, EN 55022/CISPR 22 |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | TEROS 54 |
| Sensor Type | Volumetric Water Content (VWC) & Temperature Profiler |
| Measurement Depths | 15, 30, 45, and 60 cm |
| Output Protocols | SDI-12 (3-wire & 4-wire), DDI Serial, RS-485 Modbus RTU, tensioLINK |
| Power Supply | 4.0–24.0 VDC |
| Accuracy (VWC) | ±0.05 m³/m³ (mineral soils, EC < 8 dS/m) |
| Resolution (VWC) | 0.001 m³/m³ |
| Temperature Range | –20 to +60 °C |
| Temp. Accuracy | ±0.35 °C (–20 to 0 °C), ±0.25 °C (0 to 60 °C) |
| Frequency | 70 MHz |
| Compliance | CE-marked per EM ISO/IEC 17050:2010 |
| Brand | METER |
|---|---|
| Origin | Italy |
| Model | TEROS 54 |
| Measurement Depths | 15, 30, 45, and 60 cm |
| Volumetric Water Content Range (mineral soils) | 0.00–0.70 m³/m³ |
| Temperature Range | −20 to +60 °C |
| Accuracy (VWC, mineral soils, EC < 8 dS/m) | ±0.05 m³/m³ |
| Accuracy (Temperature) | ±0.25 °C (0–60 °C) |
| Operating Frequency | 70 MHz |
| Output Protocols | SDI-12 (3- and 4-wire), DDI serial, RS-485 Modbus RTU, tensioLINK |
| Power Supply | 4.0–24.0 VDC |
| Cable Length | Standard 5 m (custom up to 75 m) |
| Enclosure | IP68-rated ruggedized profile probe |
| Compliance | CE-marked per EM ISO/IEC 17050:2010 |
| Brand | METER |
|---|---|
| Origin | Germany |
| Model | VARIOS |
| Instrument Type | Multifunctional Soil Analyzer |
| Measurement Principle | Transient Line Heat Source (TLHS) |
| Compliance | IEEE Std 442-2017, ASTM D5334, ISO 9001:2015, EM ISO/IEC 17050:2010 (CE) |
| Thermal Conductivity Range (TC-S70) | 1.3–10.3 W/m·K |
| Thermal Conductivity Range (TC-S100) | 0.8–6 W/m·K |
| Temperature Range (Storage/Drying) | −50 to 120 °C |
| Operating Temperature Range | −40 to 85 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating Current Range | 20–200 mA |
| Heating Current Resolution | 10 µA |
| Heating Current Accuracy | ±0.05% |
| Linear Power Output Range | 0.5–20 W/m |
| Power Resolution | 20 mW/m |
| Power Accuracy | ±0.1% |
| Balance Capacity | 2200 g |
| Balance Readability | 0.01 g |
| Balance Repeatability & Linearity | 0.01 g |
| Probe Dimensions (TC-S70) | 114.0 × 19.4 × 13.25 mm |
| Probe Dimensions (TC-S100) | 144.0 × 19.4 × 13.25 mm |
| Balance Dimensions | 162 × 185 × 30 mm |
| Power Supply | 12 V / 1 A |
| Interface | USB |
| OS Compatibility | Windows 10 or later |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | WP4C |
| Instrument Type | Water Potential Meter |
| Measurement Principle | Dew Point Hygrometry |
| Range | 0 to –300 MPa |
| Accuracy | ±0.05 MPa (0 to –5 MPa), ±1% (–5 to –300 MPa) |
| Temperature Range | 15–40 °C |
| Resolution | 0.1 °C |
| Temp. Accuracy | ±0.2 °C |
| Measurement Time | 10–20 min (Precision Mode), <5 min (Rapid Mode) |
| Sample Chamber Volume | 7 mL (recommended), 15 mL (max) |
| Dimensions | 24.1 × 22.9 × 8.9 cm |
| Weight | 3.2 kg |
| Display | 20×2 LCD with backlight |
| Sensors | Chilled-mirror dew point sensor + infrared temperature sensor |
| Power | 110–220 V AC, 50/60 Hz |
| Interface | RS-232A (ASCII, 9600 baud, 8N1), USB adapter included |
| Compliance | ISO 9001:2015, CE (EN ISO/IEC 17050:2010), ASTM D6836-07 |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | ZL6 Soil Water Content and Water Potential Monitoring System |
| Instrument Type | Soil Moisture and Water Potential Analyzer |
| Channel Capacity | 6-channel data logger |
| Communication | GPRS-enabled, cloud-connected via Zentra Cloud |
| Power Supply | Solar-rechargeable NiMH battery |
| Enclosure Dimensions | 14.9 × 25 × 6.3 cm |
| Compliance | Designed for long-term field deployment in compliance with ISO 11274 (soil water retention), ASTM D5859 (in-situ soil moisture measurement), and GLP-aligned data traceability per FDA 21 CFR Part 11 requirements when configured with audit-trail-enabled Zentra Cloud subscription |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SDCY-6000D |
| Automation Level | Semi-Automatic |
| Sampling Depth | 1200 mm |
| Sampling Capacity | 0–5 kg per cycle |
| Max Particle Size | 60 mm |
| Motor Power | 1.2 kW |
| Operating Voltage | 220 V AC |
| Sampler Weight | 20 kg |
| Auger Tube Diameter | Φ133 mm |
| Overall Dimensions | 1660 × 500 × 300 mm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MSP3 |
| Instrument Type | Multi-parameter In-situ Soil Analyzer |
| Optical Sensors | VIS (660 nm) & NIR (940 nm) LED-based Spectral Reflectance Sensors |
| EC Measurement | Dual-depth galvanic contact conductivity profiling (0–45 cm & 0–91 cm) |
| pH Sensing | Antimony-based ion-selective electrode (6–12 cm adjustable depth) |
| OM Depth Range | 38–76 mm |
| GPS | Garmin GPS 19X (NMEA 0183 compliant) |
| Data Acquisition | 1 Hz PIC microcontroller (80-pin), SD card logging, backlit display |
| Environmental Rating | NMEA 4X sealed electronics, MIL-spec waterproof connectors |
| Operating Temperature | −20 °C to +70 °C |
| Vehicle Requirements | ≥30 hp tractor or light utility vehicle |
| Transport Configuration | Towed chassis (229 cm W × 396 cm L × 152 cm H |
| Max Survey Speed | 20 km/h |
| Software | SoilViewer v4.x (real-time georeferenced visualization, 2D spatial interpolation, export to GIS formats) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MSP3 OM-EC-pH |
| Price | USD 70,000 |
| Instrument Type | Multifunctional In-Situ Soil Analyzer |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Regional Origin | Domestic (China) |
| Model | OASIS GMK-770S |
| Pricing | Upon Request |
| Instrument Category | Soil Moisture / Water Potential Analyzer |
| Measurement Principle | Capacitance-based Dielectric Sensing |
| Soil Types Supported | Sandy Loam, Loam, Clay Loam |
| Absolute Moisture Range | 7.0–35.0% w/w |
| Resolution | 1% |
| Accuracy | ±3% |
| Measurement Time | ~10 s |
| Temperature Compensation | Automatic |
| Display | Large LCD with Dual-Parameter Readout |
| Power Supply | 9 V alkaline battery (IEC 6LR61) |
| Dimensions (W×L×H) | 85 × 170 × 36 mm |
| Sensor Probe Length | 480 mm |
| Net Weight | ~2.0 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Oxytemp |
| Instrument Type | Multifunctional Soil Analyzer |
| Oxygen Range | 0–100% vol |
| Oxygen Accuracy | ±2% FS |
| Temperature Range | 0–90°C (32–200°F) |
| Temperature Accuracy | ±1°C (±1.8°F) |
| Probe Insertion Depths | 60, 90, 120, 150, 180 cm (selectable) |
| Dimensions (with 90 cm probe) | 137 H × 43 W × 8.9 D cm |
| Weight | ~5.5 kg |
| Probe Material | Stainless Steel (316 SS) |
| Sensor Design | Integrated dual-parameter electrochemical O₂ + thermistor probe |
| Display | Dual-line digital LCD |
| Brand | EcoTech |
|---|---|
| Origin | USA |
| Model | P3500 |
| Sensor Types | EC, VisNIR, Capacitance, Penetrometer |
| Max. Profiling Depth (Auto) | 60 cm |
| Max. Profiling Depth (Manual) | 90 cm |
| Sampling Resolution | 240 data points per insertion |
| Data Acquisition Rate | 1 Hz |
| GPS Integration | Yes |
| Sampling Tube Included | Yes |
| Compliance | ASTM D698/D1557 (soil compaction), ISO 11277 (soil texture), ISO 13879 (EC measurement), USP <1058> (analytical instrument qualification framework) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PARIO |
| Pricing | Available Upon Request |
| Particle Size Range | 1–63 µm |
| Measurement Accuracy | ±1.5% mass error |
| Sample Mass Concentration | 25–40 g/L suspension |
| Total Measurement Duration | 6 hours |
| Data Acquisition Interval | 10 s |
| Operating Temperature Range | 15–35 °C |
| Max Allowable Temperature Drift During Measurement | 3 °C |
| Suspension Volume | 1000 cm³ |
| Sedimentation Column Height | 35 cm |
| Power Consumption | 1 mW |
| Warranty | 12 months |