Spectroscopy Instruments
Filter
Showing 1801–1830 of 2557 results
| Brand | SOC/SurfaceOptics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SOC716 |
| Price Range | USD 70,000–140,000 |
| Operating Principle | Filter-Based (Snapshot Multispectral Array) |
| Imaging Method | Snapshot Filter-Array FPA |
| Deployment Mode | Ground-Based |
| Spectral Range | 270–1700 nm (configurable UV/VNIR/SWIR variants) |
| Spectral Bands | 16 discrete channels |
| Spatial Resolution | 400K pixels (e.g., 640×540 for VNIR variant) |
| Field of View (TFOV) | Configurable per optical module |
| Frame Rate | ≥30 Hz (up to 60 Hz in VNIR mode) |
| Sensor Type | Back-Illuminated CMOS (UV/VNIR), Si-CCD (VNIR), InGaAs (SWIR) |
| Bit Depth | 10–12 bit |
| Power Consumption | 2–12 W @ 12 VDC |
| Dimensions | 10.75″×3.9″×3.9″ to 6.78″×4.5″×5.6″ |
| Weight | 1.9–3.55 kg |
| Brand | SOC/SurfaceOptics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SOC720SW |
| Price | Upon Request |
| Spectral Range | 900–1700 nm |
| Spectral Resolution | 6.25 nm |
| Spectral Channels | 128 |
| Spectral Smile Distortion | <1.5 nm |
| Detector Type | High-Sensitivity InGaAs Linear Array (D* = 1.5 × 10¹³ cm·√Hz/W @ 1550 nm) |
| Spatial Resolution | 640 pixels (across-track) × 640 pixels (nominal along-track) |
| Frame Rate | 30 spatial lines/second |
| Data Cube Acquisition Time | 20 seconds/cube |
| Bit Depth | 14-bit |
| Optical f-number | f/2.4 |
| Total Field of View / Instantaneous Field of View (35 mm lens) | 10° / 0.015625° |
| Interface | Camera Link |
| Built-in Scanning Mechanism | Yes |
| Power Supply | AC / 12 V DC |
| Weight | 30 lbs (13.6 kg) |
| Dimensions | 7" × 14" × 22" (178 × 356 × 559 mm) |
| Data Format | Open BIL (Band Interleaved by Line), IEEE 754 floating-point compatible |
| Software Suite | HyperSpect™ (acquisition), HSAnalysis™ (radiometric calibration & spectral analysis), MIDIS™ (real-time multi-channel processing engine) |
| Brand | SOC/SurfaceOptics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | SOC 720 |
| Operating Principle | Push-broom |
| Imaging Method | Interferometric |
| Deployment Mode | Ground-based |
| Spectral Range | 900–1700 nm |
| Spectral Resolution | 6.25 nm |
| Spatial Resolution (IFOV) | 0.79 mrad (configurable) |
| Field of View (TFOV) | 29° (configurable) |
| Spatial Sampling | 640 × 640 pixels |
| Frame Rate | 30 fps |
| Detector | InGaAs linear array, D* = 1.5 × 10¹³ cm·√Hz/W @ 1550 nm |
| Bit Depth | 14-bit |
| Data Format | Open BIL binary |
| Interface | Camera Link |
| Power Supply | AC / 12 V DC |
| Weight | 13.6 kg (30 lbs) |
| Dimensions | 178 × 356 × 559 mm (7″ × 14″ × 22″) |
| Brand | SOC/SurfaceOptics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SOC740 |
| Pricing | Available Upon Request |
| Spectral Range | 1.0–2.35 µm |
| Detector | Cryogenically Cooled InSb (60 K) |
| Cut-off Filter | Integrated 2.35 µm Longpass Filter |
| Spatial Resolution | 640 × >2048 pixels (push-broom configuration) |
| Spectral Sampling Options | 100, 200, or 400 bands |
| Interchangeable Lenses | 28 mm, 50 mm, 200 mm (motorized lens rail for focus/FOV alignment) |
| Integration Time | Programmable |
| Optical Distortion Correction | Sub-pixel smile and keystone correction |
| Data Format | Open binary (BSQ/BIL-compatible) |
| Optional Processing Unit | SOC MIDIS™ Real-Time Onboard Processor |
| Software Compatibility | SOC Spectral Studio, ENVI, MATLAB, Python (GDAL, SciPy) |
| Brand | SOC/SurfaceOptics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | SOC716FMV-SI |
| Price Range | USD 70,000–140,000 |
| Operating Principle | Filter-Based (Tunable Bandpass Filter Array) |
| Imaging Modality | 3D Spatio-Spectral Data Cube Acquisition |
| Deployment Mode | Ground-Based |
| Spectral Range | 270–1700 nm |
| Spectral Resolution | Configurable (Typical FWHM: 5–20 nm per band) |
| Spatial Resolution | 1280 × 1024 pixels |
| Total Field of View (TFOV) | Selectable (e.g., 11.0°–12.3° depending on lens module) |
| Instantaneous Field of View (IFOV) | Configurable via focal length and pixel pitch |
| Frame Rate | Up to 30 fps (full-frame) |
| Brand | PV Measurements |
|---|---|
| Model | IV16 |
| Light Source Class | ABA-Class Solar Simulator (Standard) |
| Illuminated Area | 16 cm × 16 cm |
| Voltage Range | ±2.0 V |
| Current Range | 0–10 A |
| Spectral Match Compliance | ASTM E927-23, IEC 60904-9 Ed. 3 |
| Temporal Stability | < ±1% (A-class), < ±3% (B-class), < ±10% (C-class) |
| Irradiance Uniformity | < ±2% (A-class), < ±3% (B-class), < ±10% (C-class) |
| Standard Test Conditions (STC) | 1000 W/m², AM1.5G spectrum, 25 °C ± 2 °C |
| Software | IV Analysis Suite with GLP-compliant data logging, report generation (PDF/text), and audit-trail-enabled parameter calculation (Voc, Isc, Jsc, Pmax, Vmax, Imax, FF, η) |
| Sample Interface | 4-wire Kelvin connection |
| Optional Upgrades | AAA-class simulator, temperature-controlled vacuum chuck, Rs extraction via attenuated-light sweep, automated database export, reverse-bias leakage testing, conveyor integration |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | SPF-290AS |
| Wavelength Range | 290–400 nm |
| Scan Resolution Options | 1 nm, 2 nm, or 5 nm |
| Compliance | ISO 23698:2024, ISO 23675:2024, ISO 24443, FDA Guidance, COLIPA, Boots Star Rating Methodology |
| Sample Types | Lotions, creams, sprays, gels, powders, emulsions, textiles |
| Data Output | Monochromatic Protection Factor (MPF), SPF, UV transmittance spectra |
| Software Features | Pre-loaded erythemal action spectrum & solar irradiance reference data (CIE 1987 / ISO 17166), user-modifiable weighting functions, audit-trail-enabled calculation logs |
| Brand | SOPOTOP |
|---|---|
| Origin | Shanghai, China |
| Model Series | 721, 722, 7230G, 723PC |
| Optical System | Dual-beam |
| Detector Type | Photodiode Array |
| Wavelength Range | 325–1100 nm (model-dependent) |
| Spectral Bandwidth | 2–5 nm |
| Wavelength Accuracy | ±1.0 nm (7230G & 723PC), ±2.0 nm (721 & 722) |
| Wavelength Repeatability | 0.5–1.0 nm |
| Stray Light | ≤0.2%T at 360 nm (723PC) to ≤0.5%T at 360 nm (721) |
| Photometric Accuracy | ±0.5%T (722/7230G/723PC), ±1.0%T (721) |
| Photometric Repeatability | ±0.2%T (722/7230G/723PC), ±0.5%T (721) |
| Baseline Linearity | ±0.004A (723PC only) |
| Stability | ±0.003A/h (7230G & 723PC), ±0.5%T/5min (721 & 722) |
| Display | 128×64 LCD |
| Dimensions | 456 × 375 × 220 mm |
| Brand | SOPOTOP |
|---|---|
| Origin | Shanghai, China |
| Model | 723PC |
| Optical System | Single-beam |
| Detector | Silicon Photocell |
| Wavelength Range | 325–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ±0.5 nm |
| Spectral Bandwidth | 2 nm |
| Display | 4.3-inch color TFT touchscreen (480 × 272 pixels) |
| Data Interface | USB 2.0 |
| Software | UV-Solution PC workstation (optional) |
| Power Supply | 220 V ±10%, 50 Hz / 110 V ±10%, 60 Hz, 75 W |
| Net Weight | 10.0 kg |
| Dimensions (W × D × H) | 470 × 380 × 225 mm |
| Brand | SOPOTOP |
|---|---|
| Origin | Shanghai, China |
| Model | 752 |
| Optical System | Single-beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 200–1000 nm (0.1 nm step resolution) |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ±0.5 nm |
| Photometric Accuracy | ±0.5% T (at 0–100% T) |
| Photometric Repeatability | ±0.3% T |
| Stray Light | ≤0.3% T at 220 nm and 360 nm |
| Display | 4.3-inch color TFT touchscreen (480 × 272 pixels) |
| Data Interface | USB 2.0 |
| Power Supply | 220 V ±10%, 50 Hz / 110 V ±10%, 60 Hz, 90 W |
| Dimensions (W × D × H) | 470 × 380 × 225 mm |
| Net Weight | 10.5 kg |
| Compliance | CE, ISO/IEC 17025 compatible operation environment |
| Brand | SOPOTOP |
|---|---|
| Origin | Shanghai, China |
| Model | 754 |
| Optical System | Single-beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Scanning Step | 0.1 nm |
| Display | 4.3-inch color touchscreen (480×272) |
| Data Interface | USB |
| Software | UV-Solution workstation (optional) |
| Power Supply | 220 V ±10%, 50 Hz / 110 V ±10%, 60 Hz, 90 W |
| Net Weight | 10.5 kg |
| Dimensions (W×D×H) | 470×380×225 mm |
| Brand | SOPTOP |
|---|---|
| Origin | Shanghai, China |
| Model | 752 |
| Optical System | Single-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 200–1000 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±2.0 nm |
| Wavelength Repeatability | 1 nm |
| Stray Light | ≤0.5% T (at 220 nm and 360 nm) |
| Transmittance Accuracy | ±0.5% T |
| Transmittance Repeatability | ±0.2% T |
| Baseline Drift | ±0.003 A/h |
| Display | 128×64 LCD |
| Dimensions | 455 × 430 × 220 mm |
| Data Interface | USB |
| Wavelength Setting | Manual (keyboard-input with 6 preset wavelengths) |
| Brand | SOPTOP |
|---|---|
| Origin | Shanghai, China |
| Model | UV2800PC |
| Optical System | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.05%T at 220 nm and 360 nm |
| Display | 320×240 LCD (6-inch) |
| Software | UV-Solution 3.0 |
| Compliance | ASTM E275, ISO 6223, USP <857>, GLP-ready audit trail support |
| Brand | SP (Spectral Products) |
|---|---|
| Origin | USA |
| Detector Type | CCD |
| Spectral Range | 200–1050 nm |
| Optical Resolution | 0.15–10 nm (FWHM, configuration-dependent) |
| Stray Light | <0.05% at 632 nm (<0.1% across full range) |
| Sensitivity | High quantum efficiency (QE >60% typical in 350–800 nm) |
| Signal-to-Noise Ratio | ≥300:1 (full well, 1 s integration) |
| Dynamic Range | >10,000:1 (with 16-bit digitization and on-board baseline correction) |
| Brand | SP/Spectral Products |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | SM301 |
| Spectral Range | 1.0–5.0 µm |
| Detector Type | Thermoelectrically Cooled PbS/PbSe Linear Array |
| Resolution | 30 nm |
| Sensitivity | High |
| Signal-to-Noise Ratio | High |
| Dynamic Range | High |
| Stray Light | < 0.1% |
| Pixel Count | 256 elements |
| Readout Rate | Up to 2 MHz |
| Cooling | Peltier-cooled to –4 °C |
| Software | SM32Pro (Windows-based) |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-1920 |
| Optical Design | Dual-beam, spatially separated, asymmetric vertical optical path |
| Detector Type | Digital dual high-performance photodiodes |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1.8 nm (typical) |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | ≤0.05% T at 220 nm (NaI) and 340 nm (NaNO₂) |
| Display | 8-inch color capacitive touchscreen |
| Light Sources | 6V/10W halogen lamp (2000 h lifetime), deuterium lamp (1000 h lifetime) |
| Sample Compartment | Fixed 100 mm pathlength cuvette holder |
| Power Supply | 110/220 VAC, 50/60 Hz, ±10% |
| Dimensions (W×D×H) | 655 × 420 × 265 mm |
| Compliance | Meets ISO 9001 manufacturing standards |
| [Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-3882AAS |
| Instrument Type | Flame and Graphite Furnace Atomic Absorption Spectrometer |
| Optical System | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp, Self-absorption, and Transverse Zeeman Effect |
| Atomizer Configuration | Integrated Flame-GF Platform (No Mechanical Switching Required) |
| Burner Head | Titanium Alloy |
| Nebulizer | High-efficiency Glass Nebulizer with Optional Ceramic Upgrade |
| Graphite Furnace | Longitudinally Heated with Transverse Magnetic Field |
| Lamp System | 8-position Automatic Lamp Carousel |
| Lamp Control | Gap-controlled Hollow Cathode Lamp Power Supply |
| Safety Features | Graphite Tube Purge Gas Flow Monitoring with Auto-alarm and Interlock] |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SPEC Pro 6000 |
| Instrument Type | Full-Spectrum Simultaneous Readout |
| Safety Integration | Integrated Glovebox System |
| RF Generator Architecture | Separated Solid-State RF Source |
| Optical System | Echelle Grating with Thermally Stabilized Optics |
| Detector | Back-Illuminated High-Speed CCD with Anti-Blooming Design |
| RF Power Range | 700–1600 W (Continuously Adjustable) |
| RF Cooling | Water-Cooled |
| Power Stability | <0.1% |
| Gas Control | Multi-Channel Digital Mass Flow Controllers (Accuracy: ±0.01 L/min) |
| Nebulization System | 12-Rotor, 4-Channel Peristaltic Pump with Optional Internal Standard/Standard Addition Capability |
| Torch Design | Modular, Self-Aligning, Center-Tube-Replaceable Echelle Torch |
| Software Platform | Element V (Fully Localized Chinese Interface with GLP-Compliant Audit Trail) |
| Brand | Specac |
|---|---|
| Origin | United Kingdom |
| Model | Atlas |
| Max Operating Temperature | 300 °C or 400 °C |
| Adjustable Film Thickness | 15, 25, 50, 100, 250, 500 µm |
| Sample Diameter | 29 mm |
| Configuration Options | Standalone press unit (15631/15800) or integrated press + manual 15-ton hydraulic press (15633/15810) |
| Compliance | Designed for ASTM E1252, ISO 18381, and USP <1118> FTIR sample preparation |
| Brand | Specim (Finland) |
|---|---|
| Origin | Finland |
| Model | AFX10 / AFX17 |
| Spectral Range | AFX10 — 400–1000 nm (Vis-NIR), AFX17 — 900–1700 nm (NIR) |
| Spatial Resolution | Up to 1280 pixels across track |
| Frame Rate | Up to 300 fps (configurable) |
| Integration | GNSS/IMU-aided georeferencing |
| Platform Compatibility | UAVs (multirotor, fixed-wing), light aircraft |
| Onboard Processing | Embedded real-time data acquisition & preprocessing unit |
| Data Output Format | ENVI-compatible raw and radiometrically calibrated cubes (.bil/.hdr) |
| Weight | < 2.5 kg (full integrated system) |
| Brand | Specim (a Konica Minolta company) |
|---|---|
| Origin | Japan |
| Model | Specim AFX Series |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 5.5 nm |
| Platform Compatibility | UAV-mounted (multirotor & fixed-wing) and ground-based operation |
| Integration | Integrated GNSS/IMU, onboard computing unit, FX-series hyperspectral camera |
| Software Compatibility | Specim CaliGeo PRO, ENVI, PCI Geomatica, QGIS (with appropriate plugins) |
| Data Output Format | Radiometrically calibrated, georeferenced ENVI-compatible .hdr/.raw files |
| Brand | Specim |
|---|---|
| Origin | Finland |
| Model | AISA |
| Imaging Principle | Push-broom |
| Imaging Method | Dispersive |
| Platform Compatibility | Ground-based and airborne (fixed-wing, rotary-wing, manned & unmanned aircraft) |
| Spectral Range | 400–1000 nm (VNIR), 600–1600 nm (VNIR-SWIR overlap), 400–2500 nm (full VNIR-SWIR), 7.7–12.3 µm (LWIR) |
| Spectral Resolution | 1.75 nm / 3.5 nm / 7 nm (VNIR), 10 nm / 15 nm (SWIR), 100 nm (LWIR) |
| Spatial Pixels | 2048 (VNIR), 384–1024 (SWIR variants), 616 (LWIR) |
| Field of View (TFOV) | 32° |
| Instantaneous Field of View (IFOV) | Height-dependent |
| Frame Rate | ≥100 fps |
| Brand | SPECIM |
|---|---|
| Origin | Finland |
| Model | ArtScanner |
| Spectral Ranges | VNIR (400–1000 nm), NIR (900–1700 nm), SWIR (1000–2500 nm) |
| Maximum Scan Length | 190 cm |
| Illumination Source | Broadband Halogen Lamp (400–2500 nm) |
| Camera Mounting | Easy-Lock Modular Interface |
| Compatible Platform | Fully Interoperable with SisuCHEMA Hyperspectral Data Acquisition Suite |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CNT-NIR Series |
| Price | Upon Request |
| Brand | SPECIM |
|---|---|
| Origin | Finland |
| Camera Type | Push-broom imaging spectrometer |
| Optical Design | Dispersive (transmissive prism-grating) |
| Mounting Flexibility | Ground-based & airborne deployment |
| Spectral Ranges | 400–1000 nm (FX10), 900–1700 nm (FX17), 960–2500 nm (SX25), 2.7–5.3 µm (FX50), 7.7–12.3 µm (FX120) |
| Spectral Resolution | 5.5 nm (FX10), 8 nm (FX17, SX25), 35 nm (FX10 – alternate specification) |
| Spatial Pixel Count | 1024 (FX10), 640 (FX17, FX50, SX25), 616 (FX120) |
| Pixel Size | 8 × 8 µm (FX10), 15 × 15 µm (FX17) |
| Field of View (TFOV) | 38° |
| Instantaneous Field of View (IFOV) | Configurable per lens |
| Frame Rate | 330 Hz (FX10 full spectrum), 670 Hz (FX17 full spectrum), 380 Hz (FX50), 162 Hz (SX25), 240 Hz (FX120) |
| Interface | GigE Vision & Camera Link |
| Calibration | Factory-applied spectral and radiometric calibration traceable to NIST standards |
| Operating Temperature | Thermally stabilized optics with internal non-uniformity correction |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Specim FX Series |
| Pricing | Upon Request |
| Operating Principle | Push-broom Scanning |
| Deployment Mode | Ground-based & Airborne Compatible |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 5.5 nm |
| Spatial Resolution | 1024 pixels |
| Brand | Specim |
|---|---|
| Origin | Finland |
| Model | FX10/FX17 |
| Operating Principle | Push-broom |
| Imaging Optics | Binary optical element |
| Deployment Mode | Ground-based & airborne compatible |
| Spectral Range | 400–1000 nm (FX10), 950–1700 nm (FX17) |
| Spectral Resolution | 5.5 nm (FX10), 8 nm (FX17) |
| Spatial Resolution | 1024 × 1024 pixels (FX10), 640 × 1024 pixels (FX17) |
| Field of View (TFOV) | 38° |
| Instantaneous Field of View (IFOV) | 640 px / 1024 px (FX17 / FX10) |
| Frame Rate | 330 fps (FX10 GigE), 670 fps (FX17 CameraLink) |
| Brand | SPECIM |
|---|---|
| Origin | Finland |
| Model | FX50 |
| Operating Principle | Push-broom |
| Imaging Optics | Binary optical elements |
| Deployment | Ground-based |
| Spectral Range | 2.7–5.3 µm |
| Spectral Resolution | 35 nm |
| Field of View (TFOV) | 24°, 45°, or 60° |
| Frame Rate | 380 fps |
| Interface | GigE Vision |
| Calibration | Factory-performed spectral and radiometric calibration |
| Thermal Stability | Actively temperature-stabilized optics |
| Spatial Resolution | Not specified (system-dependent on lens and working distance) |
| Compliance | Designed for industrial automation environments |
| Brand | SPECIM |
|---|---|
| Country of Origin | Finland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Range | Multiple Models (IQ, FX10/FX17/SX25/FX50/FX120, SWIR) |
| Price Range | USD 42,000 – 70,000 (approx.) |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive (prism/grating-based) |
| Deployment Modes | Ground-based & Airborne |
| Spectral Coverage | UV to LWIR (200 nm – 12.3 µm) |
| Spectral Resolution | 5.5 nm – 100 nm |
| Spatial Pixels | 384 – 1024 px |
| Frame Rate | 162 Hz – 670 Hz |
| FOV | Model-dependent |
| IFOV | Configurable via lens selection |
| Cooling | Thermoelectric (SWIR, MWIR, LWIR models) |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | Specim |
|---|---|
| Origin | Finland |
| Model | ImSpector |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Platform Compatibility | Ground-based & Airborne |
| Spectral Range | 380–1700 nm |
| Spectral Resolution | 6 nm |
| Spatial Resolution (IFOV) | 30 µm |
| Field of View (TFOV) | 8°–56° |
| Frame Rate | 100 Hz |
| Imaging Format | 6.6 mm (spectral) × 8.8 mm (spatial) |